You are on page 1of 2

V1.0(2022.

01)

LFP 51.2-100 Datasheet

Features
Cost Longer
Effectiveness Service Life

Lithium
≥ 6000
cycles

Guaranteed Fast Charge Drop-in


Safety Replacement

BMS

Technical Characteristics
NORMINAL CHARACTERISTICS MECHANICAL CHARACTERISTICS
Nominal Voltage 51.2 V Case Material SPCC
Nominal Capacity 100Ah(1P16S) Dimension(L*W*H) 450mm*442mm*133mm
Energy 5120 Wh Weight About 45 Kg
IR ≤30mΩ@100%SOC Terminal Type M6
Efficiency ≥99.5% IP Grade 54
Maximum Modules in Series 16 BCI Group NO. /
Cell Type-Chemistry LiFePO4
BMS CHARACTERISTICS
Primary Charging Protection Current: 80 A
CHARGE & DISCHARGE CHARACTERISTICS
Delaytime:1000ms
Voltage Window 44.8-57.6V
Secondary Charging Protection Current: 100A
Max. Continuous Charge Current 50 A
Delaytime:500ms
Max. Continuous Discharge Current 100 A
Primary Discharging Protection Current: 110A
Peak Discharge Current 120A(5 s±2s)
Delaytime: 5 s±2s
Secondary Discharging Protection Current: 120A
Delaytime: 5 s±2s
OPERATING CONDITIONS Over-charge Voltage Protection Voltage:57.6~58.4V
Cycle Life ≥6000 times Delaytime:500ms
Operating Temperature Charge: 0℃~60℃ Over-discharge voltage protection Voltage: 43.2 V
Discharge:-20℃~60℃ Delaytime:500ms
Storage Temperature -20℃ ~ 30℃ Temperature Protection PCB temperature≥95℃
Storage Duration 12 months at 25℃ Recover≤85℃
Heating Function / Communicating Function RS485 CAN
LFP 51.2-100 Datasheet

Constant Current Discharge Data(Amperes@25℃)


1h 2h 3h 4h 5h

Cut-off Voltage (44.8V) 100A 50 A 33.4 A 25 A 20 A

Constant Power Discharge Data(Watt@25℃)


1h 2h 3h 5h 10h

Cut-off Voltage (44.8V) 5120W 2560W 1707W 1024 W 512 W

Cycle No.Vs DOD


Number of Cycles Vs. DOD Discharge Performance at R.T. Cycle Life in Relation to Temperature
Cycle Life with DOD at 25℃,0.5C
1 10 1C 3000
57.6
0 .5C
1 00 54.4 0.2C 2500

51.2
90 2000
48.0
80 44.8 1500
1 00% DOD 80% DOD 50% DOD 30% DOD

70 41.6 1000
36.0
60 500
33.0

50 30.0 0
0 2000 4000 6000 7000 9000 12000 0 20 40 60 80 100 120 0 20 30 40 50 60 70

Number of Cycle (cycles) Capacity (%) Temperture( ℃ )

Battery Capacity (C) Vs. Open Circuit Voltage (OCV) Battery Capacity Vs. Charging Time Temperature Effects on Capacity
SOC Vs OCV Charging Capacity(%) VS Time at
different rate at 25℃
56.0 110 110
1C 0. 5C 0. 2C 0. 1C
1 00
1 05
90
52.8 100
80
95
70
49.6 90
60
85
50
46.4 80
40
30 75
43.2 20 70
10 65
40.0 0 60
0 1 2 3 4 5 6 7 8 9 10 11 12 -30 -20 -10 0 10 20 30 40 50 60 70
1 00.00% 80.00% 60.00% 40.00% 20.00% 0.00%

Capacity Retention Ratio Charging Time (hours) Temperature( ℃)

You might also like