Power Meter & Energy Meter


Motor Protection Controller
Mu
Multi-Channel Power Meter
System Solution
Current Transformer

DFUN (ZHUHAI) CO., LTD.


600

25
0 Single Phase DC Energy Meter

10
12
14
80H Quality Analyzer 18

Motor Protection Controller


PMAC801A Motor Protection Controller 22

SPM20 AC Multi-Channel Energy Meter 30 25


SPM20-D DC Multi-Channel Energy Meter
PMAC211 AC Multi-Channel Energy Meter 30

System Solution

xGate6-Lite Smart Gateway 3


5

Current Transformer

CTSB Split Core Current Transformers 0


BH - 0.66 SeriesⅠSolid Core Current Transformers
SPM90 (DC) SPM91 SPM93 SPM32 SPM33 PMAC770 PMAC780H SPM20 PMAC211

30 Channel 12 Channel

(NO “F”)

IEC61850 Protocol
Charter 1

Power Meter
Energy Meter
Motor Protection Controller
0 C Energy Meter

Basic Function
Real-time measure one circuit DC voltage, current, power , kWh
High accuracy: Class 0.5s
One LED indicate pulse output
RS485 port, MODBUS-RTU or DL/T645 protocol (optional)
35mm DIN rail installing, standard DIN ED5002
Shunt: 100A, 200A, 300A, 400A

Power supply 9~36VDC Dimension (L*W*H) 100*36*65mm (2 moudule)


Rated Voltage DC 0~1000VDC Power frequency
3000VAC
Rated Current DC 100A, 200A, 300A, 400A withstand voltage

Rated voltage: 75mV Insulation resistance ≧


Shunt
Accuracy: Class 0.2 Impulse voltage 6000V

Starting Current 0.001Ib Operating temperature: -20℃~ +55 ℃


Pulse output 1 channel, pulse constant: 1000imp/kWh Limit Temperature: -25℃~ +75 ℃
Environment
Storage temperature: -30℃~ +80 ℃
Power loss 
Humidity: < 95%
RS485 port
Electrostatic Discharge Immunity Test IEC61000-4-2:2001
MODBUS-RTU or DL/T645-2007 (Settable) RF Electromagnetic Field Immunity testing IEC61000-4-3:2002
Communication Electrical fast transient immunity test IEC61000-4-4:2004
Address: 1~247
EMC Standard Surge immunity test IEC61000-4-5:2005
Baud rate: 2400, 4800, 9600, 19200bps Injected Current Immunity Test IEC61000-4-6:2006
Electromagnetic emission limit Passed
IP index IP20 Voltage sag and short-time interruption Immunity testing Passed

Parameter Measurement Range Accuracy


Voltage 0-1000VDC 0.2%
Current 1% ~ 120% of rated 0.2%
Power 0~300kW 0.5%
Energy 0~999999.999kWh Class 0.5s

90
1 100A Shunt
2 200A Shunt
3 300A Shunt
4 400A Shunt

P Pulse Output

Example: Model No. SPM90-1, which indicate the device provides with basic function and pulse output,100A shunt, MODBUS-RTU
communication protocol.

Note: Default Pulse output function, MODBUS-RTU protocol, baudrate 9600bps, settable for DL/T645-2007 protocol
<2W



91
5(6)A 5(63)A
load

Direct: 5(63)A 3P/4W


Or 5(6)A via CT

AC voltage tests 4kV

Power
consumption
400imp/kWh for 5(63)A
6400imp/kWh for 5(6)A
VAC VAC
VAC VAC

Direct: 5(63)A

var Mvar

MVA
93 3

VAC ph-N)
VAC ph-N)
RS 2 relay outputs + 2 status inputs

3P/3W, 3P/4W

250VAC/5A or 30VDC/5A

85~265VAC or 100~300VDC
Power <4W
consumption
(Wet contact)
RS 2 relay outputs + 2 status inputs
3P/3W, 3P/4W 85~265VAC or 100~300VDC
Power <5W
consumption
3 status inputs ( wet contact ) + 2 relay outputs

15
3P/3W, 3P/4W, 1P/2W

120V, 220V, 240V, 277V, 398Vph-N (optional)

Power
consumption 5W

16
3 4

85 ~ 265VAC, or 85 ~ 265 VDC, 45 ~ 65Hz


100 ~ 420VAC, or 100 ~ 400VDC, 45 ~ 60Hz

85 ~ 265VAC, or 85 ~ 265 VDC, 45 ~ 65Hz


100 ~ 420VAC, or 100 ~ 400VDC, 45 ~ 60Hz
17
780H Power Quality Analyzer

Description
Power Quality Management System
Harmonic Analysis
Energy Supply failure analysis
Voltage Sag Source Location
Transient disturbances location

Main Function
Class A Power Quality Measurement : Harmonic and inter-harmonic, voltage deviation, frequency deviation, unbalance, fluctuation
and flicker, transient disturbances, EN50160 statistics
Class 0.2s Accuracy : Harmonic, ,fundamental harmonic, sub-harmonics energy
High Resolution Failure Record : support 1024 point/cycle, Min.tansient disturbance record for 20us
Failure Diagnose Location : support voltage sag source, harmonic source, flicker source, asymmetric source location and power
supply failure type diagnose
Full Real-time Data Measurement

Feature
With all multifunction power meter function

Class 0.2s high accuracy energy mesurement

Power quality analysis: harmonic analysis,


recod analysis and flicker analysis

Failure record : bulk memory for data record


and setpoint alarm

Failure diagnose location, 20us for transient


disturbance record

Measurment Parameters
Wave Sampling 1024 points/cycle wave
2~63rd Harmonic, harmonic ratio, phase angle, total harmonic distortion (THD),
Harmonic
Power Quality total odd / even harmonic distortion
Analysis and Inter-Harmonics 2~63rd Inter-harmonic, harmonic ratio, Total inter-harmonic distortion
location Waveform record, DO alarm, timing record, record voltage sag/ swell's start time,
Voltage Sag / Swell / Stop
stop time, duration time and their Max. and Min. value and voltage variation depth
Capture 20us circle wave transient, trigger/ DO port, waveform record, record
Transient Capture
voltage transient happen time, amplitude and durantion time etc.

18
780H Power Quality Analyzer

Unbalance Voltage, current unbalance and zero sequence unbalance

Power Quality Voltage / Frequency Deviation Setpoint alarm and record


Analysis and Repid Voltage Alteration Trigger DO point, waveform record
location Voltage Fluctuation and Flick Analysis Calculate long time flicker Plt and Short time Pst
Sag Source Location Can locate power supply side or load side abnormal and fault

Measurement Voltage 4 Channels


Channel Current 4 Channels
Voltage Phase / line / average voltage, phase angle, refresh time : 1s, 0.5s circle waveform
Current Phase / average current, phase angle, refresh time: 1s, 1 circle waveform
Active power, Reactive power,
Real-time Data Phase & total power, refresh time: 1s, 1 circle waveform
Apperant Power
Power Factor Phase & total power factor, refresh time: 1s, 1 circle waveform
Frequency 50/60Hz, refresh time: 1s, 1 circle waveform
Positive / Negative active, reactive, apparant energy ; Positive / Negative base
Energy
wave active, reactive energy
2~31st positive active, reactive harmonic energy, Negative active, reactive
Energy Harmonic Energy
harmonic energy
History Energy Storage latest 30 days and latest 12 months history energy data
Multi-tariff energy 4 tariff, 8 time period, 2 time zone
Has fixed window and slid window record volue including: three phase current,
total active power, total reactive power, total apparant power, support real-time
Real-time Demand
demand and predict demand, Max. demand and happend time, support DI
Demand demand synchronization

Demand Prediction Predict next demand circle value according to present real-time active power
value. Interval demand fixed circle: 15min.
Memory 8G
Max. / Min Record This month and last month Max./Min. value and happen time
SOE Record 1024 records, time resolution: 1ms
PQ Record 1024 records, time resolution: 1ms
Circle wave before failure is settable, Waveforme record mode as below: 1: 1024
points / circle wave @ 50 circle wave: 2: 512 points/circle wave @ 100 circle wave;
Data and Waveform Record 3: 256 points/circle wave @ 200 circle wave; 4: 128 points/circle wave @ 400
circle wave;5: 64 points/circle wave @ 800 circle wave; 6: 32 points/circle wave @
Evern Record
1600 circle wave;7: 16 points/circle wave @ 3200 circle wave

Transit Wave Record 256 piece


ITIC/SEMIF47 Curve 1 Groups
In accordance with EN 50160 power quality standard, Statistics voltage, frequency,
EN50160 Statistics Function harmonic, flicker, deviation, unbalance and voltage disturbance passed rate and
other power quality index
Mark Function Mark voltage sag/ swell/ stop etc. transit even data, statistics by customer
Digital Input (DI) 8 Channels
DI/ DO
Relay Output (DO) 4 Channels
Optocoupler Output 2 Channels
Display LCD colorful interface, display measurment value, harmonic bar chat, vetorgram,
Display
time record, I/O status, ITIC waveform etc. resolution: 640 * 480
Voltage / Frequency Deviation 2, baud rate:1200~38400bps, MODBUS-RTU protocol
Communication
Repid Voltage Alteration 1, Modbus TCP/ IEC61850 (optional), support Ethernet Gateway
Voltage Fluctuation and Flick Analysis SNTP, Modbus
Time calibration
Sag Source Location GPS pulse, IRIG-B signal

19
780H Power Quality Analyzer

Advantage
Function

PMAC780H

Normal Power Meter

Relay Protection Device

Fault Recorder Device

Note : Area means function relation

voltage
380V 10kV 35kV 110kV UP
Specially for 380V~35kV voltage level's industry and commercial building
High-density sampling frequency, can record instantaneous, transient voltage disturbance
Bulk memory function, can dynamic record each even
Class A harmonica content function, harmonic measure times with high accuracy
Powerful function, combine multifunction power meter + energy meter + power quanlity analyzer + failure recorder into one

Interface

Home Page Real-time Monitoring Evaluation Report

Real-time Waveform Vector Analysis 63rd Real-time Harmonic Analysis

SmartPQM Power Quality Management System

Overview Unbalance Transient

0
780H Power Quality Analyzer

Dimensions

Technical specification
Power Supply Communication

Rated Voltage 85~275VAC, 100~300VDC,45~65Hz RS485 port 2 Port, 2400-38400bps, Modbus-RTU protocol
Power loss <10W 1 port, Modbus TCP / IEC61850 (optional)
Ethernet Port
support Ethernet gateway
AC Input
Electrical insulation performance
Rated voltage 0~400V (400V L/N / 690V L/L)
Input Dielectric strength 2kV voltage, 1 minute (GB/T 14598)
Overload 1.2 Un, Continuous; 4Un, accept 1s
Voltage Insulation resistance 





Power loss < 0.1VA/Phase
Impulse voltage 6kV, 


Rated voltage 5A, 1A
Input Environment
Current Overload 4In, Continuous; 10In, accept 1s
Temperature - 10℃~+55℃ Humidity 5%~95%
Power loss < 0.5VA/Phase@5A, < 0.1VA/@1A
Storage - 40℃~+85℃ Pressure 70kPa~110kPa
DI / DO
Front: IP52 Measure 3 phase 4 wire
DI 8 Channels, time resolution 1ms IP Index mode
Side & Back: IP30 3 phase 3 wire
RO1-RO4 Relay, action / return time: <10ms Electromagnetic compatibility
Breaking Capacity:250VA/30VDC,0.2A,
L/R=20ms Max. voltage 30VDC Electrostatic discharge immunity IEC6100-4-2 Class IV
DO1-DO2
Max. current 50mA Radio frequency electromagnetic radiation immunity IEC6100-4-3 Class IV
Accuracy Power loss IEC6100-4-4 Class IV
Volage/ Current ±0.1% Harmonic Class A Rated voltage IEC6100-4-5 Class IV
Active / Reactive / Overload IEC6100-4-8 Class IV
±0.2% Voltage Unbalance Rate ±0.1%
Apparant power
Mechanical Character
Power loss Class 0.2s Current Unbalance Rate ±0.5%
Vibration response Class I (GB/T 11287)
Rated voltage Class 2 Voltage Deviation ±0.1%
Vibration durable Class I (GB/T 11287)
Overload ±0.5% Frequency Deviation ±0.005Hz
Impact response Class I (GB/T 14537)
Power loss ±0.005Hz Fliker ±5%
Collision response Class I (GB/T 14537)

Order Information
PMAC780H

V1 3*220/380V (direct), 5A
V2 3*220/380V (direct), 1A
V3 3*57.7/100V (via PT),5A
V4 3*57.7/100V (via PT),1A
V5 3*400/690V (direct), 5A
V6 3*400/690V (direct), 1A

SW External power supply (Wet Contact) digital input


SD No external power supply (Dry contact) digital input

CP IEC61850 Protocol

Note : PMAC780H default with Ethernet port, if select CP function, then support IEC61850 protocol, otherwise it won't support.
1
801A Motor Protection Controller Relay

Application
Lower Voltage MCC
Integrated process and electrical control

Features
Suit for motors rated voltage 380V AC or 660V AC
Small Size compact design with LCD display
Integrated measurement, protection and control functions
Main module provide 9 DIs (digital input) and 5 DOs (digital output)
Optional 1 analog (4~20mA) input or 1 leakage current protection
Small size and configuration.
Easy installation. Proper for 35mm DIN rail.
35mm DIN rail mounting
Safety, Excellent quality and multifunction

Function
Full Protection Function Full Protection Function
Pre-start: Wiring checking, fault treatment and confirmation Starting Control: 32 event record support protection mode, direct
Starting Process: Monitor the starting time period and current start mode, star/delta start mode, autotransformer start mode

Running Process: 18 protections, like Overload protection, TE Re-star Control: Anti sway electric , under-voltage re-start,
time protection, Over-current protection, Phase failure protection... auto re-start etc. function

Motor Life Cycle Management Operation Control: Support locan control, DCS control,
communication control
Running Management
Other Function
Event Record: 32 event record with timescale, full range record
for motor operation, fault record and so on Multiple Control: Modbus-RTU / Profibus-DP
Time management and authority management
Function Configuration
Start Overtime Yes I, In, I_avg., I_unbal. Yes
Measure
Start Over-current Yes U, P, Q, PF, F, kwh, I△n Yes
Overcurrent Yes Starting Control Yes
Current unbalance Yes Control Re-start Control Yes
Overload Yes Self-start control Yes
Underload Yes DI 9 DI in main module Standard
Underload Yes DO 5 DO in main module Standard

Short circuit Yes MODBUS-RTU Standard


Earth Fault Yes COM Profibus – DP
Optional
Eex e overload (tE) Yes or another MODBUS-RTU
Protection
External fault Yes AO One 4~20mA DC analog output Standard
Overvoltage Yes AI One 4~20mA DC analog input Standard
Under voltage Yes SOE Latest 32 event records Standard
Under power Yes Total running time period Standard
Phase Sequence error Yes Present running time Standard
TV open circuit Yes Total stop operation time Standard

Wiring Checking Yes Present stop operation time Standard


SOE
Overflow fault Yes Total stop operation time Standard
Temperature (PTC/NTC) Optional Total trip times Standard
Leakage current Optional Longest starting time Standard
Analog Input Optional Max. starting current Standard

2
801A Motor Protection Controller Relay

PMAC801A Included



Start Run Alarm Trip Com PMAC801A
Run



Com


PMAC801A
Fault

External port
Profibus-DP Start A Start B Stop Reset

PMAC801A Main Moudle Display Module (LCD )

Optional Leakage CT

Ø4
5

76
4

67
76

Current Transformer Current Transformer Current Transformer Leakage Current Transformer


(for <100A) (for 250A, 400A) (for 500A, 820A) (for 100A~800A)

PMAC801A Includes
PMAC801A 3 4 2 2A (For motor: 0.1 – 1.1 kW)
6.3 6.3A (For motor: 1.1 – 3.1 kW)
10 10A (For motor: 3.1 – 5.3 kW)
25 25A (For motor: 5.3 – 11 kW)
50 50A (For motor: 11 – 22 kW)
100 100A (For motor: 22 – 45 kW)
250 250A (For motor: 45 – 132 kW)
400 400A (For motor: 132 – 211 kW)
500 500A (For motor: 211 – 264 kW)
820 820A (For motor: > 264kW)

P Profibus-DP
F Dual Modbus_RTU

C Leakage current protection


A One 4~20mA Analog Input
C & A can't not select at the same time

T 1 Temperature input
Can not select together with F (dual Modbus-RTU)

Notes:
1. Standard PMAC801A including main module, display module, current transformer, 1 RS485, 1 Analog output
2. If customer need leakage current protection, please select leakage current transformer
3. Standard wire for current transfomer is 1.5m
4. Main module and display module connect with a standard wire (1m), please mention before place the order if you need longer wire (3.5m),
5. Standard main module has protection functions: start overtime, start overcurrent, overload, overcurrent, Eex e overload (tE), phase failure,
current unbalance, short circuit, earth fault, underload, undervoltage, underpower, external fault, phase sequence error, TV open circuit,
overflow fault

3
Charter 2 Multi-Channel Power Meter
SPM20 AC Multi-Channel Energy Meter

High Accuracy - Voltage & Current class 0.5s, kWh class 1.0

5
SPM20 AC Multi-Channel Energy Meter

1P/2W, 3P/4W

1P/2W

3P/4W

45 ~ 65Hz

Power Consumption

SPM20-C: Solid Core Sensor SPM20-O: Split Core Sensor

(C)

(O)

(C)

(O)

(C)

(O)

6
SPM20 AC Multi-Channel Energy Meter

SPM20-O

SPM20-C

SPM121 LoRa

SPM20 -M 1P/2W & 3P/4W

-C
SPM20
-O

For example: 1pcs SPM20-M + 20pcs SPM20-C indicate 1pcs SPM20 main module and 20pcs SPM20-C solid core sensor.

7
SPM20 D DC Multi-Channel Energy Meter

Description
SPM20-D is specially design for telecommunication base station application to calculating power consumption, measuring DC device electricity.

It is the smallest DC multi-channel Energy Meter with compact design, consists of main module and measure module. Very user friendly installation
for simplize the installation at size.

Application
Telecommunication BTS Billing System

DC Load Management

Feature
Small Size - Can be install at the closest point, integrate in existing space
Easy Installation - Consist of main module and measur module, connected by PLbus Daisy chain bus topology and RJ12 port,
measure module straight insert into the circuit breaker
High Accuracy - Voltage & Current class 0.5s, kWh class 1.0
- 48VDC Power Supply - Special design for Telecom BTS application

Wide Measurement Range - Max. support 63A direct connect, no need for extra Hall Sensor or Shunt
Multi Circuit - Support 12 single phase circuit

Function
Measure -- Voltage, Current, Power, Energy (input / output / total)
Alarm - Voltage limit alarm (high limit/ low limit), Current limit alarm (high limit), Communication failure alarm
Communication - Modbus-RTU protocol, RS485 port

Technical Specification
SPM20-D-M: Main Module

1P/2W

6W

8
SPM20 D DC Multi-Channel Energy Meter

CDS: Measure Module

Accuracy Environment & Temperature

Typical Connection

Order Information

SPM20 - D -M
SPM20 - D -S

For example: 1pcs SPM20-D-M + 12pcs SPM20-D-S indicate 1pcs SPM20-D main module and 12pcs SPM20-D-S solid core sensor for
12 DC Circuit measuring, -48VDC power supply

9
PMAC211 AC Multi-Channel Energy Meter

,12x1 phase AC measuring

3P/4W

Power
Consumption

30
PMAC211 AC Multi-Channel Energy Meter

4 12 Channels,

PMAC211 Multi-Channel Energy Meter

31
Charter 3 System Solution
xGate6-Lite Smart Gateway

Feature
Powerful Data Collecting & Forwarding Function
Automation collection and multi transmit mode, support Modbus_TCP,
JSON, XML, HTTP(s), can connect to various cloud software and system.

Effective and Reliable Data Storage and Management


Build-in SQL, Two-way communication and packet verification, support
JSON & XML data packet continue transferring from breakpoint.

Convenient Batch Configuration, Debugging & Update


To suit distributed deployment &Ethernet management in IoT system,
especially large scale system with cloud management.

Support Modbus_RTU, Modbus_TCP, DLT645, IEC103, Build-in SQL data base


CJT188 device Max. 12 months Historical data & alarm records storage (hh:mm:ss)
Max. 1,000 data points, Max. 64 devices SMS Message Record
Max.2 RS485 ports, each port support ≦32 slave devices Standard 8GB TF card (Max 32GB Micro -SD TF card)

Alarm Funtion
1 GPRS for 4G data transmit SMS Alarm
Max. 1,000 data points, Max. 64 devices Multiple alarm setting for each device
Support HTTP(s) XML and JSON forwarding format Real-time alarm data transmit

xGate6-Lite External Network System

xGate6-Lite

3
xGate6-Lite Smart Gateway

Item Parameter Description


Port No. / Port Type R2 RS485 Port, Support Modbus_RTU, Modbus_TCP, DLT645, IEC103, CJT188 protocol

Baud rate 1200bps ~ 115200bps (Optional)


COM Port
Data Transmit Mode Master Mode

Support Connect IED Quantity !"#


$
?KZ
$
[
K \
] \^# 

TF Port (Standard) Port No. / Port Type 1 Port, Standard 8G (Max. 32GB Micro-SD TF card)

Ethernet Port
Port No. / Port Type 1 Ports, 10/100M
(Standard)

Port No. / Port Type 1 Port, 4G SIM card (Dimension 15mmX25mm)


SIM Port • LTE FDD Band 1,3,5,8 • LTE TDD Band 34,38,39,40
GPRS for xGate6-Lite-2CL • WCDMA Band 1,8 • GSM 900/1800MHZ
• 1 SIM Port, SIM card (Dimension 15mmX25mm)

CPU: Mipsel 580MHz Color: Black

Memory: DDR 128MB 4 Indicate Light: indicate Run, COM1, COM2,


Hardware Structure
Flash: Nor flash 32MB Installation: DIN Rail Mounting

MTBF: >=50,000 hours Size(L*W*H): 98.2*63*68mm

Input: AC85-265V or DC80-300V Working Temperature -15℃ ~ +55℃


Power supply Environment
Consumption: < 5W Storage -25℃ ~+ 70℃, 5~95%@non-condensing

Oscillatory waves immunity test


Electrostatic discharge immunity test
Radiated radio-frequency electromagnetic field immunity (RFEMS)
Testing and measurement techniques - Electrical fast transient/burst immunity test
Surge immunity test
Radio frequency interference immunity
Power frequency magnetic field immunity test
Electromagnetic emission limits
Power frequency immunity

68.00
63.00 63.00

RUN COM1 COM2


94.00

98.20

DIN Rail 35mm

Lite

2CL 2 RS485,Cellular Network (Support 4G), 1 Ethernet Port

Customer order xGate6-Lite-2CL, it means the device has standard 1 8GB TF port, 1 10/100M Ethernet port,
Cellular Network (Support 4G) and other basic function.
4
32

SMS alarm notice

xGate6-Lite External Network System

5
6
32

()$&)*++,+'+'-
  (.$&)*+++
    !"#
$ %& ()$/0+'+,
Port !"#
$'& (10)/4/54/56++
("/0"57/*"*,048
(/905 #:/90  ; < 

9 / Type 5 #  '$ 


9 / Type '5 #   ? # #

DO / Type 5 #     



    

* Notice : Customer need to double check with local operator to see if the GPRS frequency selection is support or not.

7
2ZL 2 RS485, 4 DI, 2 AI, 1 DO, Cellular Network (Support 4G)
4CL 4 RS485, Cellular Network (Support 4G)

P1 AC 85 ~265V or DC 100~300V
P2 DC18~36V

Customer order xGate6-2ZL-P2, it means the device has standard 1 USB 2.0 port, 1 8GB TF port, 2 10/100M Ethernet ports,
with optional function 2 RS485 ports, 4 DI (Dry contact), 2 AI (4~20mA), 1 DO and Cellular Network (Support 4G), power
supply DC18~36V.

38
Charter 4 Current Transformer
CTSB Split Core Current Transformers

Description
The CTSB series of split core style current transformers are
designed for fast and easy installation. The split core design
permits non-contact current measurements through magnetic
field induction without disconnecting cables or busbar circuits
for CT installation. This method permits a safer, easier and
portable current measurement.

Application
Current, power, energy, monitoring devices

Power Factor Correction devices


Active Power Filter Ro H S

Feature
Low cost

5 standard sizes
Split core design, safer, easier installation, and portable

Technical specification
Rated Primary current AC 100-5000A
Rated Secondary current AC 5A & 1A (Optional)
Rated load 1, 2.5, 5.0, 10, 30VA
Accuracy 0.5, 1.0, 3.0 Class
Rated security coefficient FS<5
Case Material UL flame retardant rating 94-V0
Frequency Range 50~400Hz
Operating Temperature -15 ć to 50ć
Standard IEC 60044-1
Accessories Supplied with feet for base mounting if required
Highest Voltage for Equipment Um (rms) AC 720 V
Rated Power-Frequency Withstand Voltage (rms) AC 3000V

Order Information
CTSB / 5A
0203 20*30mm
0508 50*80mm
0512 50*120mm
0812 80*120mm
0816 80*160mm

Rated input current

40
CTSB Split Core Current Transformers

Outline Dimension And Performances

Burden(VA) Weight
Model A B C D E F G H I Ratio
Class0.5 Class1.0 Class3.0 (kg)

100 : 5 -- -- 1.5
150 : 5 -- -- 3.0
200 : 5 -- 1.5 2.5
CTSB0203 21 31 51 89 105 34 42 40 32 0.78
250 : 5 -- 1.5 3.75
300 : 5 1.5 3.75 5.0
400 : 5 2.5 5.0 10.0
250 : 5 -- -- 3.75
300 : 5 -- 2.5 5.0
400 : 5 2.5 3.75 7.5
CTSB0508 50 80 78 114 145 32 32 32 33 500 : 5 2.5 5.0 10.0 0.9
600 : 5 2.5 5.0 15.0
750 : 5 3.75 7.5 15.0
1000 : 5 5.0 10.0 20.0
600 : 5 -- 2.5 3.75
750 : 5 2.5 3.75 7.5
1000 : 5 5.0 7.5 10.0
1250 : 5 5.0 7.5 12.5
CTSB0512 55 125 108 143 191 44 36 49 30 2.2
1500 : 5 7.5 10.0 15.0
2000 : 5 10.0 10.0 20.0
2500 : 5 15.0 20.0 25.0
3000 : 5 15.0 20.0 30.0
500 : 5 2.5 5.0 10.0
600 : 5 2.5 5.0 15.0
750 : 5 3.75 7.5 15.0
CTSB0812 80 120 108 144 185 32 32 32 33 1.25
1000 : 5 5.0 10.0 20.0
1250 : 5 7.5 12.5 20.0
1500 : 5 7.5 15.0 25.0
500 : 5 2.5 5.0 10.0
600 : 5 3.75 5.0 15.0
750 : 5 5.0 10.0 15.0
1000 : 5 10.0 15.0 20.0
1250 : 5 12.5 15.0 25.0
CTSB0816 80 160 120 176 247 48 48 52 38 1500 : 5 15.0 20.0 25.0 4.4
2000 : 5 15.0 20.0 30.0
2500 : 5 15.0 20.0 30.0
3000 : 5 20.0 25.0 30.0
4000 : 5 20.0 25.0 30.0
5000 : 5 20.0 30.0 40.0

41
BH-0.66 Series ĉ Current Transformers

Feature
Rectangular shape with stepped window to fit bus bar as well
as single or multi-cables.Main applications are metering and
instrumentation.
Full complete ratio range with six sizes for more application
choices.With its enhanced burden feature,30*30I's rated
burden is able to reach 5 to 10VA with the primary current
lower than 100A,when the turns of the cable going through the
core are 20 to 3.

Order Information

BH 0.66 Ⅰ
0.66 Insulation Level(kV)

30
40
60 Size
80
100

Ⅰ Model Series Type

Dimension

Outline Window Installational Installational


Dimension Dimension Dimension Method
Model A B
W H D a e d {
M N M N

30Ⅰ 60 78 34 31 11 12 23 32 58 40 57 ABCE
H
e

40Ⅰ 75 98 43.5 42 11 13 30.5 45 58 52 66 ABCE


a
60Ⅰ 102 125 46 62 21 23 45 42 58 56 69 ABCE

M 80Ⅰ 118 138 45 81.5 10.5 30 52 60 58 A B E


D
W N
100Ⅰ 146 154 45 101 10.5 31.5 62 80 58 A B E

42
BH-0.66 Series ĉ Current Transformers

Technical Parameters

Model 30ĉ 40ĉ 60ĉ 80ĉ 100ĉ


MaxCable Size 23 30.5 45 52 62
60*10/1 80*10/1 100*10/1
Max busbar Size / QTY 30*10/1 30*10/1 60*6/1-2 60*10/1-2 80*10/1-2
Accuracy Class 0.5 1.0 0.5 1.0 0.2 0.5 0.2 0.5 0.2 0.5

Primary Current / Secondary Current (A) Rated Burden(VA)

15 5 2.5(5) 2.5(5)

20 5 2.5(4) 2.5(4)

25 5 2.5(3) 2.5(3)

30 5 2.5(3) 2.5(3)

40 5 2.5(2) 2.5(2)

50 5 2.5(2) 2.5(2)

60 5 2.5(2) 2.5(2)

75 5 2.5 2.5

100 5 2.5 2.5

150 5 2.5 2.5 5

200 5 5 5

250 5 5 5

300 5 5 5 5 5

400 5 5 5 5 5

500 5 10 5 10 10

600 5 10 5 10 5 10 5 10

750 (800) 5 10 5 10 5 10 5 10

1000 5 15 20 15 20 10 20

1200 (1250) 5 20 20 20

1500 5 20 20 20

2000 5 20 20 20

2500 5 30 30

3000 5 30

Ordering Instruction
1.Please specify the model name,transformation ratio,accuracy class,rated burden,and required installation method,when placing a purchase
order.
2.If there is any special requirements,please contact us,so we can custom make upon request.
3.Unless specified in the order,data in black is standrd,data in red is customized.
4.The numbers in the brackets indicate the times of the cable going through the core.