You are on page 1of 1

PT.

COLUMBIA CHROME INDONESIA


BALIKPAPAN - INDONESIA

REPORT NO B- 6592/TI/CCI.QC/BPP/ VI / 14
REPORT DATE 27-Jun-14
TECHNICAL INSPECTION REPORT PAGE 01 of 01

CUSTOMER PT.KTC COAL MINING&ENERGY PRO / SR NO N/A COMPONENT NAME ROD BUCKET CYL
UNIT MODEL HYD EXA ZX 330 STATUS UNIT N/A HYD EXA ZX 330
DELIVERY NOTE (SJ) N/A STATUS JOB WAITING APPROVE COMPONENT P/N N/A
WO NO. CCI B-6592 SUPPORT PT. CCI BALIKPAPAN COMPONENT HOURS N/A
KELUHAN:
1. OD Rod Cyl Scratch dan Bending ± 2 mm
URAIAN KERUSAKAN :
1. OD Rod Cyl terdapat Scratch dan Bending ± 2 mm
PHOTO & SIZE INSPECTION
HASIL PENGAMATAN :
1. OD Rod Cyl di temukan Scratch dan Bending ± 2 mm

B 6592

HASIL PENGUKURAN ID TUBE (MM)


1 2 3 4 5
X 0 0 0 0 0
Y 0 0 0 0 0
Standard OD : ……. mm
Standard Toleransi : ……... mm
Panjang Chrome : ……. mm
Panjang Total : ……….. mm
HASIL PENGUKURAN OD ROD 02 (MM)
1 2 3 4 5
X 94,85 94,87 94,88 94,85 94,88
Permukaan Rod Y 94,85 94,85 94,88 94,85 94,88
Scratch dan Standard OD : 95 mm
Bending Standard Toleransi : 94,92 - 94,98 mm
Panjang Chrome : 1385 mm
Panjang Total : 1742 mm
TEST BENDING
1 2 3 4 5
X 0 0 1 0 0
Repair eye rod,ganti
Y 0 0 1 0 0
bushing eye rod
Total 0 0 2 0 0
THICKNESS / KETEBALAN CHROME / MICRON
1 2 3 4 5
X 63 58 56 51 53
Y 60 60 51 49 53
HARDNESS TESTER / KEKERASAN CHROME / HRC
X 0 0 0 0 0
Y 0 0 0 0 0
KESIMPULAN :
1. OD Rod Cyl terdapat Scratch dan Bending ± 2 mm
DETAIL PERBAIKAN :
PT Columbia Chrome Indonesia merekomendasikan perbaikan :
1. Re - Rod
2. Repair eye rod
3. Ganti bushing eye rod
WAKTU / LEAD TIME : .......... Days

Balikpapan, 27 Juni 2014


Sincerely Yours, Acknowledge

FIRDAUS YULIANSYAH HERWINDO


QC COORDINATOR BRANCH MANAGER