1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. Routine Job.

Chief Officer / Belo Oleksandr

ED:

1. PWO 601053: M/E TC All fixing screws, casing screws and pipe connections checked for tight fit. Gas side
dry cleaning performed on regular basis.

2. PWO 651053: AE#1,2 TC compressor was cleaned.

3. PWO 651067:AE#1 Thermometer and pressure gauge checked. Found in good condition.

4. Cleaning engine-room.

C/E Zhylenko S

02.01.2021

DD:

1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. PWO 151004 - Deck Department Routines – Weekly

4. PWO 151005 - Gas Detection Equipment, Checks – Monthly

5. Chipping, Brushing and First coat of primer applied Grab No 3.

6. Greased Quick-acting Cleats on Hatch Covers

7. Brushing and First coat of primer applied Grab’s plates.

Chief Officer / Belo Oleksandr

ED:

1. PWO 151003: Engine Department Weekly Routines, all equipment tested, checked, and found in good
condition.
2. Cleaning engine-room.

3. PWO 651041: LO Priming pump was checked for heating, vibration and excessive noise. The pump in good
working condition.

4. PWO 653001: Provision crane level of gear unit was checked, no remarks.

C/E Zhylenko S

04.01.2021

DD:

1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. PWO 564001 - Pilot and Accommodation Ladders from PORT and STBD sides checked. All steps and
handrails of accommodation ladder are in good condition without any defects. Safety net in satisfactory
condition. Ladders greased via greasing points.

4. PWO 564005 – Accommodation Ladder & Winch from PORT and STBD sides checked. Ladders greased via
greasing points.

5. PWO 564018 - Pilot and Accommodation Ladders from PORT and STBD sides checked.

6. Cleaned inside of Deck cranes.

7. Chipping and brushing Grab’s plates.

8. Segregation of Garbage.

9. Greased Mast house’s doors.

Chief Officer / Belo Oleksandr

ED:

1. PWO 701026: Marine Diesel Oil Transfer pump, El. motor was checked, no abnormal noise, no
overheating & vibration.

2. PWO 721002: Main Sea Water Cooling Pump, El. motor No.3 was checked, no abnormal noise, no
overheating & vibration.

3. PWO 722004: M/E Jacket Cooling Fresh Water Pump, El. motor No.2 was checked, no abnormal noise, no
overheating & vibration.

4. PWO 897031: Officers Mess Room Exhaust Fan El. motor was checked, without any foreign noise &
vibration. Megger test was done.
5. PWO 651024: AE#2 fuel oil system, swing arms and rollers, bush were inspected. Carried out all
measurements all is range.

6. PWO 762001: Technical Water Pump #1, was checked for abnormal noise, vibration, and heating.
Foundation bolts were checked for tightening.

C/E Zhylenko S

05.01.2021

DD:

1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. Chipping, brushing and First coat of primer applied for Grab’s plates.

4. Chipping and First coat of primer applied for Suez Light Motor.

5. Chipping Grab No 3. Job in progress.

6. Commenced greasing crane's wire ropes. Inside the cranes – job completed. Outside wire ropes will be
greasing as soon as possible. Vessel rolling and pitching due to bad weather.

Chief Officer / Belo Oleksandr

ED:

1. PWO 813032: Emergency Fire Pump, El. motor No.2 was checked, no abnormal noise, no overheating &
vibration.

2. PWO 891003: Emergency lights was checked, no remarks.

3. PWO 515050: Window wipers was checked, all in working condition.

4. PWO 445001: Incinerator fan belts and tensions, diesel oil and sludge burner, thermocouple for
combustion chamber were checked.

5. UWO 226065: A/E Storage & Settling Lub. Oil tanks was open, visual inspection and cleaning carried out.
No remarks.

6. Cleaning engine-room.

C/E Zhylenko S
06.01.2021

DD:
1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. Finish paint applied of Grab’s plates.

4. Second coat of primer applied for Suez Light Motor.

5. Chipping and First coat of primer applied of Grab No 3.

6. Chipping Grab No 2. Job in progress.

Chief Officer / Belo Oleksandr

ED:

1. PWO 444029: M/E Air Cooler Chemical Cleaning Pump, El. motor was checked. No abnormal noise, no
vibration and overheating.

2. PWO 581003: FW hydrophore pump #1, El. motor was checked, no abnormal noise, no overheating &
vibration.

3. PWO 713022: S/T lub oil pump #1, El. motor was checked, no abnormal noise, no overheating & vibration.

4. UWO 226060: ME Storage Lub. Oil tanks was open, visual inspection and cleaning carried out. No remarks.

5. PWO 734014: Control air dryer, inspected and cleaned, condenser surface blown by air.

C/E Zhylenko S

07.01.2021

DD:
1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. PWO 502005 - Life raft Maintenance – Monthly.

4. PWO 504015 - Visual inspection of Fire Blanket carried out. Fire Blanket found in good condition, properly
stored at assigned position.
5. Cleaning inside of accommodation.

6. Routine job.

Chief Officer / Belo Oleksandr

ED:

1. PWO 417071: Transmitting Heading Device. Terminals for securing and re-tight, condition of cables
entrances, securing of sensors and devices, waterproof condition of protected units and connection boxes
were checked, no remarks.

2. PWO 571001: ECR AIRCON. Fan/motor operation, vibration, holding down bolts, support brackets and
terminal box were checked. Suction filter was renewed, bearings were greased.

3. PWO 722008: Low Temperature Cooling Fresh Water Pump, El. Motor No.1 was checked, no abnormal
noise, no overheating & vibration.

4. PWO 801003: Ballast Pump, El. Motor No.1 was checked, no abnormal noise, no overheating & vibration.

5. PWO 403001: Steering gear checked visually. Filter indicator is color green.

6. Cleaning engine-room.

C/E Zhylenko S

08.01.2021

DD:
1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. PWO 383251 - Fuel Oil Hose Davit inspection from PORT and STBD sides.

Were checked as follows:

- connect surface has a good lubrication state.

- checked for any obstruction around the crane.


- connection bolts in position no remarks.

4. PWO 433001 - Windlass & Mooring Winches checked. Satisfactory condition.

5. Chipping and First coat of primer applied of Grab No 2.

6. Second coat of primer applied and finish pints of Grab No. 3

7. The steel material on the Pilot and Accommodation ladders de-rusting and paining with stainless steel
paint. Job in progress.

Chief Officer / Belo Oleksandr

ED:

1. PWO 651075: A/E No.2 & No.3: Alternators was checked, blowing with compressed air performed,
tightening of all bolts, nuts and wire connections checked. Air filters renewed. Bearing was greased.

2. PWO 651069: A/E No.3 Governor. Brush of governor was checked. Normal size, good condition.

3. PWO 722012: M/E Jacket Fresh Water Pre-Pump, El. motor was checked. No abnormal noise, no vibration
and overheating.

4. PWO 722003: M/E Jacket Cooling Fresh Water Pump #2, was checked for abnormal noise, vibration, and
heating. Foundation bolts, coupling bolt & coupling were checked for tightening.

5. PWO 722013: Temperature Control Valve, operating condition checked.

6. Cleaning engine-room.

C/E Zhylenko S

09.01.2021

DD:
1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. Chipping and First coat of primer applied of Grab No 2.

4. Finish paint applied of Grab No. 3.

5. The steel material on the Pilot and Accommodation ladders de-rusting and paining with stainless steel
paint. Job in progress.

8. PWO 151004 - Deck Department Routines – Weekly

6. Greasing Rubber Pads of Ventilations and Doors around the Accommodation.


7. Chipping, brushing and First coat of primer applied for Grab’s plates.

Chief Officer / Belo Oleksandr

ED:

1. Early PWO 581002: Fresh Water hydrophore pump #1, disassembled, replace mechanical seal with new
spare one due to leakage. Use 1 pc. ROB - 1 pc

2. PWO 722008: Low Temperature Cooling Fresh Water Pump, El. Motors No.2 & No.3 was checked, no
abnormal noise, no overheating & vibration.

3. PWO 762002: Technical Water Pump, El. Motor No.1 was checked, no abnormal noise, no overheating &
vibration.

4. PWO 897032: Crews Mess Room Exhaust Fan. El. motor checked. No abnormal noise, vibration or
overheating. Megger test was done.

5. PWO 151003: Engine Department Weekly Routines, all equipment tested, checked, and found in good
condition.

6. PWO 301047: Main Hydraulic Pump #2, the tightening screws of the valves and service hatch, condition of
oil, regulating valves and hoses were checked.

7. PWO 762001: Technical Water Pump, was checked for abnormal noise, vibration and heating. Foundation
bolts were checked for tightening.

C/E Zhylenko S

10.01.2021

DD:

Chief Officer / Belo Oleksandr

ED:

1. PWO 733001: Working Air compressor, direction of rotation, v-belts, safety valves were checked. Drain the
condensation water.

2. PWO 651053: AE#1 TC compressor was cleaned.

3. PWO 571002: A/C plant, system checked for coolant leakages, no leakages observed. Condenser
disassembling and cleaning was not performed due to using of fresh water as cooling medium and enough
cooling capacity.
4. PWO 441023: Welding Equipment was checked. It is good condition.

5. Cleaning engine-room.

C/E Zhylenko S

11.01.2021

DD:
1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. Second coat of primer applied and finish paint of Grab No 2.

4. Chipping, brushing and First coat of primer applied for Grab’s plates.

5. Chipping and First coat of primer applied of Grab No 1.

Chief Officer / Belo Oleksandr

ED:

1. PWO 441003: Drilling Machine, all cables, plugs and connections are secured. Grinding Wheels were
inspected for wear and damage. The equipment bearings and lathe surfaces were lubricated.

2. PWO 441007: Grinding Machines, all cables, plugs and connections are secure. Grinding wheels were
inspected for wear and damage. The equipment bearings and lathe surfaces were lubricated.

3. PWO 651075: A/E No.1 Alternator wires & cables connections tightness checked. Air filters renewed.

4. PWO 278010: Impressed Current Cathodic Protection (ICCP). Contacts and connections were checked.
Good condition.

5. PWO 581024: Hot Water Circulating Pump, El. motor was checked, no abnormal noise, no overheating &
vibration.

6. PWO 762002: Technical Water Pump, El. motor No.2 was checked, no abnormal noise, no overheating &
vibration.

7. PWO 571002: A/C Plant , checked for coolant leakages - no leakages detected. Fastenings and screw
connections checked. AHU fan checked, bearings greased, v-belts tension checked and belt dressing
applied; air filters replaced; internals of evaporator and fan compartments cleaned; operation of dampers
checked and lubricant applied.
C/E Zhylenko S

12.01.2021

DD:

1. Navigational watch and lookout duties.


2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. Finish paint of Grab No 2.

4. Second coat of primer applied and Finished paints Grab’s plates.

5. Chipping and First coat of primer applied of Grab No 1.

6. PWO 431002 - Anchor, shackles, swivel and fastening device in chain locker found satisfactory Anchor
stowed properly, shackle and pin locked. Condition of anchor & chain found satisfactory.

7. PWO 431003 - Anchor chain inspection. Anchor chain stowed properly. Lock shackle and pin checked.

Chief Officer / Belo Oleksandr

ED:

1. Early PWO 871001: Main Switchboard No.1 & No.2. Inspect, check grounding, clean dust by brush.

2. PWO 713022: Stern Tube Lube Oil Pump No.2, El. motor was checked, no abnormal noise, no overheating
& vibration.

3. PWO 651075: A/E No.1 Alternator bearing was greased.

4. PWO 897015: Hydraulic Pump Room Exhaust Fan El. motor checked. No abnormal noise, vibration, or
overheating. Megger test was done.

5. Early PWO 866001: Emergency Batteries. Replaced Weather Facsimile Receiver battery with new one.

6. PWO 403001: Steering Gear, hydraulic system checked, LO coolers blown with compressed air, oil is clean.
Hyd. filters checked.

C/E Zhylenko S

13.01.2021

DD:
1. Navigational watch and lookout duties.
2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. Chipping, brushing and First coat of primer applied of Grab No 1.

4. PWO 433001 - Windlass & Mooring Winch Inspect – Yearly.

5. PWO 434001 - Mooring Winch Inspect – Yearly.

6. PWO 327001 - Grabs 2, 3, 4 Greased – Monthly.

7. PWO 501004 - Rescue Boat Check – Monthly. Equipment checked and found in good order. Drain plug
checked. Propeller in good condition. Fuel in enough quantity for 4-hour maneuvering. Navigation light
and searchlight are operational.

8. PWO 501011 - Life/Rescue Boat Davit Check – Monthly. Automatic release hook - found in good order.
Wire rope visually inspected - no damages, grease applied. Slewing ring in good condition. Oil level
checked. No remarks.

Chief Officer / Belo Oleksandr

ED:

1. PWO 651060: AE No.1 crankshaft deflection measurement carried out.

2. UWO 651040: Sump tank was cleaned, and inspection carried out. Refill with fresh oil. Use 720 liters. ROB -
1980 ltrs

3. PWO 43001: Steering gear checked visually. Filter indicator is color green, replaced does not performed.

4. PWO 897004: Emergency Fire Pump Room Exhaust Fan, El. motor checked. No abnormal noise, vibration, or
overheating. Megger test was done.

5. PWO 897016: Fire Control Room Exhaust Fan, El. motor checked. No abnormal noise, vibration, or
overheating. Megger test was done.

6. PWO 713003: M/E Main Lube Oil Pump, El. Motor No.1 & No.2 was checked, no abnormal noise, no
overheating & vibration.

7. Early PWO 813007: Fire, Bilge and General Service Pump, El. Motor No.1 & No.2 was checked, no abnormal
noise, no overheating & vibration.

8. Early PWO 711004: Lube Oil Transfer Pump, El. Motor was checked, no abnormal noise, no overheating &
vibration.

C/E Zhylenko S

14.01.2021
DD:
1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. Second coat of primer applied and Finish paints of Grab No 1.

4. PWO 275001 - Structural Fire Protection – Monthly

5. PWO 503004 - Bridge Pyrotechnics Checks – Monthly. 12 Parachute Red Rockets in WT container available,
Line Throwing Apparatus available, Man-Overboard light/smoke available. All expiry dates checked. Daylight
Signaling Lamp & source of power tested. Three Black Ball shapes, One Black Diamond shape, Cylindrical
Shape, Forecastle Bell, Gong, Ship's Whistle checked.

6. PWO 505005 - Fire Station and Equipment checks – Monthly. Fire Station equipment checked/tested.
Inventory list posted in the store and is correct.

7. PWO 505035 - Test of Breathing Apparatus Sets – Monthly.

8. PWO 505045 - Fireman outfit Inspection – Monthly. Fireman's Outfits inspected, contains their full
inventory, found in good order, properly stored.

9. PWO 529001 - Escape Routes Checks – Monthly.

10. PWO 813012 - Fire Pumps, Main Piping’s, Fittings, Fire Boxes, Hoses and Nozzles Check-Monthly. Inspected,
in operational condition and well-marked. No remarks.

11. Chipping, brushing, first coat of primer applied of AFT Hatch to Rope Store.

12. Chipping, brushing, first coat of primer applied of FWD Hatch to Bosun Store.

13. Finished paints Grab’s plates.

14. Chipping, brushing, first coat of primer applied of Port Side Fuel hatch.

15. Chipping, brushing, first coat of primer applied of Sounding Pipes.

Chief Officer / Belo Oleksandr

ED:

1. PWO 866001: Emergency Batteries. All batteries were inspected & cleaned, disconnect the terminals,
clean, coat with Vaseline and retighten.

2. PWO 897027: Galley Exhaust Fan, El. motor checked. No abnormal noise, vibration, or overheating.
Megger test was done.

3. PWO 897028: Galley Supply Fan, El. motor checked. No abnormal noise, vibration, or overheating.
Megger test was done.

4. PWO 651001: AE #1 complete, all flexible mountings, buffers were visually inspected - found in good
condition.

5. PWO 651046: AE #1 LO and centrifugal filters were inspected and cleaned.


6. PWO 755001: Atmospheric Condenser, visually inspected. Disassembling and cleaning was not
performed due to using fresh water as cooling medium and absence of leaks or reduced capacity.

7. PWO 734014: Control Air Dryer checked: evaporator blown with compressed air, check for coolant
leakages performed.

8. PWO 897030: Hospital and Lavatory Exhaust Fan, El. motor checked. No abnormal noise, vibration, or
overheating. Megger test was done.

9. PWO 897033: Crews Pantry Exhaust Fan, El. motor checked. No abnormal noise, vibration, or
overheating. Megger test was done.

C/E Zhylenko S

15.01.2021

DD:
1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. Finish paints of Grab No 1. Job Completed. Deficiency closed DR 06.

4. Second coat of primer applied / finish paints of AFT Hatch to Rope Store.

5. Second coat of primer applied / finish paints of FWD Hatch to Bosun Store.

6. Finished paints Grab’s plates. Job Completed.

7. Second coat of primer applied / finish paints of Port Side Fuel hatch.

8. Second coat of primer applied / finish paints of Sounding Pipes.

9. PWO 128014 - Security Training: Internationally Established Security Levels.

10. PWO 331001 - Deck Crane Inspect – Monthly. During inspection were checked condition of the rope. Found
without damages. Greasing wire ropes 15.01.2021. Air condition units in order. Greased as per monthly
Lubricating Chart.

11. PWO 327001 - Grab Greasing - 1 Monthly.

Chief Officer / Belo Oleksandr

ED:

1. PWO 897014: Steering Gear Room Supply Fan, El. motor was checked, without any foreign noise &
vibration. Megger test was done.

2. PWO 897039: Fire Control Room Exhaust Fan, El. motor was checked, without any foreign noise &
vibration. Megger test was done.
3. PWO 897029: Lavatory Exhaust Fan, El. motor was checked, without any foreign noise & vibration.
Megger test was done.

4. PWO 897034: Officers Pantry Exhaust Fan, El. motor was checked, without any foreign noise &
vibration. Megger test was done.

5. Early PWO 897037: Engine Change Exhaust Fan, El. motor was checked, without any foreign noise &
vibration. Megger test was done.

6. Early PWO 897038: Deck Change Exhaust Fan, El. motor was checked, without any foreign noise &
vibration. Megger test was done.

7. Cleaning engine-room.

8. M/E TC compressor were cleaned.

9. PWO 582001: Sewage macerating ang discharge pumps were checked for abnormal noise, vibration
and heating. Foundation bolts were checked for tightening. Pumps in good working condition.

10. PWO 582025: The sewage treatment plant was inspected. Pumps were checked for excessive noise,
leakage, suction and delivery pressures and abnormal heating. Air blower filter was thoroughly cleaned
with brush and cleaned out by blowing. All in good condition.

11. PWO 403006: Steering Gear Hydraulic Pump #1 & #2, all fixing elements of axial piston unit were
checked for tight seating. foundation bolts and piping also checked for tightness. No abnormalities or
leaks were detected.

C/E Zhylenko S

16.01.2021

DD:
1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. Segregation garbage.

4. Cleaning of accommodation.

5. Routine job.

6. PWO 151004 - Deck Department Routines – Weekly. Internal communication system - Tested no remarks.
Watertight doors / access - checked no remarks. LB&RB -visually checked /tested no remarks. Fire doors -
checked no remarks. Fixed fire alarm checked -in working order no remarks. Water mist, Water spray and
sprinkler system - visually inspected no remarks, control panel indicators and alarms are functional.
GMDSS and Navigation equipment - without remarks.

Chief Officer / Belo Oleksandr


ED:

1. PWO 581003: Fresh Water Hydrophore Pump, El. motor No.2 was checked, no abnormal noise, no
overheating & vibration.

2. PWO 897035: Crews Laundry and Drying Exhaust Fan, El. motor was checked, without any foreign noise &
vibration. Megger test was done.

3. PWO 897036: Officers Laundry and Drying Exhaust Fan, El. motor was checked, without any foreign noise
& vibration. Megger test was done.

4. PWO 897009: Paint Room Exhaust Fan, El. motor was checked, without any foreign noise & vibration.
Megger test was done.

5. Early PWO 646006: Boiler Control Panel. Terminals for corrosion, damage & security were checked; internal
wiring for cut, cracked & frayed insulation checked; switches & internal connectors for loose connections &
corrosion checked; dust & dirt removed by low pressure air. Automatics, alarms, stopping devises & signal
lamps, connection wire, contactors, relay of boiler and control panel were checked.

6. PWO 151003: Engine Department Routines – Weekly, equipment tested, checked, and found in good
condition. OWS is malfunction.

7. PWO 601026: Fuel valve test pump was checked.

8. PWO 631021: Stern tube seal system inspected, and function checked. No leakages or other abnormalities
detected. Level in AFT & FWD seal Tk checked.

C/E Zhylenko S

18.01.2021

DD:
1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. Chipping, brushing, first coat of primer applied of AFT Hatch to Rope Store.

4. Maneuvering mode. Passing Singapore Strait.

5. Greased the hinges of Hatch covers natural ventilations.

6. Washing and cleaning Funnel.

7. Routine job.

Chief Officer / Belo Oleksandr

ED:
1. ME monthly performance carried out. Cylinder oil drain samples took for analysis.

2. PWO 801003: Ballast Pump, El. Motor No.2 was checked, no abnormal noise, no overheating & vibration.

3. PWO 803004: Daily Bilge Pump, El. Motor was checked, no abnormal noise, no overheating & vibration.

4. PWO 898006: Engine Room Supply Fans No.2 & No.3, El. Motors was checked, greased bearing, without
any foreign noise & vibration. Megger test was done.

5. Early PWO 898006: Engine Room Supply Fans No.1 & No.4, El. Motors was checked, greased bearing,
without any foreign noise & vibration. Megger test was done.

6. Early PWO 897006: Engine Room Supply Fans No.1, 2, 3 & 4, El. Motors was checked, greased bearing,
without any foreign noise & vibration. Megger test was done.

7. PWO 601081: Hydraulic top bracing, inspection performed according to Instructions. No abnormalities
observed. Oil pressure in all units is 7 bar.

8. PWO 812001: Quick Closing Valves functioning test performed.

9. Emergency fire pump, was checked no leaks, no abnormal noise or heating detected.

10. Cleaning engine-room.

C/E Zhylenko S

19.01.2021

DD:
1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. Second coat of primer applied, finish paint applied of AFT Hatch to Rope Store.

4. Maneuvering mode. Proceeding to Kemaman anchorage.

5. ISPS watch at Kemaman anchorage.

6. Greasing Rubber Pads of Ventilations and Doors around the Accommodation, Mast Houses.
Chief Officer / Belo Oleksandr

ED:

1. PWO 721002: Main Sea Water Cooling Pump, El. motor No.1 was checked. No abnormal noise, no vibration
and overheating.

2. PWO 898024: Pipe Tunnel Supply Fan, El. motor was checked, without any foreign noise & vibration.
Megger test was done.

3. PWO 646005: Composite boiler was inspected according to all steps in PMS and maker manual instruction.
The Boiler in good working condition. No abnormalities were observed during inspection.

4. PWO 651053: AE#1 TC compressor was cleaned.


5. PWO 898023: Workshop Room Exhaust Fan, El. motor was checked, without any foreign noise & vibration.
Megger test was done.

6. PWO 898025: Rudder Cabin Supply Fan, El. motor was checked, without any foreign noise & vibration.
Megger test was done.

7. PWO 898040: Steering Gear Supply Fan, El. motor was checked, without any foreign noise & vibration.
Megger test was done.

8. M/E TC compressor were cleaned.

9. Cleaning engine-room.

10. Maneuvering mode.

C/E Zhylenko S

20.01.2021

DD:
1. Anchor and ISPS watch at Kemaman anchorage.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. Routine Job.

4. Segregation garbage.

5. Cleaning inside accommodation.

6. PWO 501002 - Lifeboat Inspection/Maintenance - carried out according to Company Form DR 12. Condition
and expire dates of all Lifeboat equipment - checked. Locker and contents checked according to Inventory
List. Internal and external lights and searchlight are operational.

Chief Officer / Belo Oleksandr

ED:

1. PWO 651004: AE #1 connecting Rod of Cyl#1-5 was checked for tightening and wire securing. All in good
condition.

2. PWO 651046: AE#2 , LO general filter and centrifugal were cleaned.

3. Early PWO 722004: M/E Jacket Cooling Fresh Water Pump, El. Motor No.1 was checked, no abnormal noise,
no overheating & vibration.

4. Early PWO 898005: CO2 Room Exhaust Fan, El. motor was checked, without any foreign noise & vibration.
Megger test was done.

5. Early PWO 713042: M/E Cylinder Lube Oil Transfer Pump, El. motor was checked, no abnormal noise, no
overheating & vibration.

6. Early PWO 651075: A/E No.1 Alternator was checked: blowing with compressed air performed, tightening
of all bolts, nuts and wire connections checked. New air filter installed.
7. PWO 713007: ME hydraulic lub oil filter, boll & kirch super-fine filter was installed according service letter
Service Letter SL2018-662/JOF.

8. PWO 601029: ME Accumulators were checked, abnormalities were not found, working condition.

Unit 1 – 34 C – 144.2 bar; Unit 2 – 34 C – 144.6 bar; Unit 3 – 34 C – 144.5 bar; Unit 4 – 34 C – 144.1 bar

Unit 5 – 34 C – 144.0 bar

HPS 1 – 38 C – 148.7 bar; HPS 2 – 38 C – 148.5 bar; HPS 3 – 38 C – 148.6 bar

C/E Zhylenko S

21.01.2021
DD:

1. Arrival at Kemaman. Mooring Operation.


2. Initial Draft Survey.
3. Cargo and ISPS watch at Kemaman, Malaysia.
4. PWO 501010 - Lifeboat Davit inspected, grease applied, all grease points lubricated.
5. PWO 501023 - Movable parts of Lifeboat hook device checked and moved for several times. Condition
good.
6. Routine Job.
7. Cleaning and Disinfection Upper Deck inside accommodation.

Chief Officer / Belo Oleksandr

ED:

1. PWO 582002: Sewage Pump, El. motor was checked, no abnormal noise, no overheating & vibration.

2. PWO 701007: Heavy Fuel Oil Transfer Pump, El. motor was checked, no abnormal noise, no overheating &
vibration.

3. PWO 897004: Emergency Generator Room Supply Fan, El. motor was checked, no abnormal noise,
overheating and vibration. Megger test was done.

4. Cleaning engine-room.

C/E Zhylenko S

22.01.2021
DD:
1. Cargo and ISPS watch at Kemaman, Malaysia.
2. Routine Job.
3. Cleaning and Disinfection Upper Deck inside accommodation.

Chief Officer / Belo Oleksandr

ED:

1. PWO 897024: Pipe Tunnel Supply Fan, El. motor fan was checked, no abnormal noise, overheating and
vibration. Megger test was done.

2. PWO 897025: Rudder Cabin Supply Fan, El. motor fan was checked, no abnormal noise, overheating and
vibration. Megger test was done.

3. Cleaning engine-room.

4. PWO 646009: Boiler Burner, grease cam strip, igniter, dirt trap, flame scanners were cleaned. Cables,
sockets, tension and condition of V-belt were checked. All in good working condition.

5. ME cyl # 4 replace fuel injectors with spare recondition FWD & AFT.

C/E Zhylenko S

23.01.2021
DD:

1. Cargo and ISPS watch at Kemaman, Malaysia.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. PWO 151004 - Deck Department Routines – Weekly. Internal communication system - Tested no remarks.
Watertight doors / access - checked no remarks. LB&RB -visually checked /tested no remarks. Fire doors -
checked no remarks. Fixed fire alarm checked -in working order no remarks. Water mist, Water spray and
sprinkler system - visually inspected no remarks, control panel indicators and alarms are functional.
GMDSS and Navigation equipment - without remarks.

4. Routine Job.

5. Cleaning and Disinfection Upper Deck inside the accommodation.

Chief Officer / Belo Oleksandr

ED:
1. Early PWO 665005: Emergency Generator, Alternator all coils in good condition, normal color and clear.

2. Early PWO 721002: Main Sea Water Cooling Pump, El. motor No.2 was checked, no abnormal noise, no
overheating & vibration.

3. Early PWO 651069: A/E No.1 Governor brush of governor was checked. Normal size, good condition.

4. Early PWO 601002: M/E Cylinder Covers with Valves No.1, cylinder cover of Unit #1 replaced with spare
one due to AFT fuel injectors stuck in cylinder cover. Exhaust valve, starting air valve fitted with old one.
FWD & AFT fuel injectors install spare recondition. ME RH 25275

5. PWO 151003: Engine Department Routines – Weekly, equipment tested, checked, and found in good
condition. OWS is malfunction.

C/E Zhylenko S

25.01.2021

DD:

1. Final draft Survey.

2. Departure from Kemaman, Malaysia. Unmooring Operation.


3. Navigational watch and lookout duties.

4. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

5. Maneuvering mode. Passing Singapore straight.

6. Cleaning inside the accommodation.

7. Washing Main Deck by sea water.

8. Routine job.

Chief Officer / Belo Oleksandr

ED:

1. PWO 897005: CO2 Room Exhaust Fan, El. motor fan was checked, no abnormal noise, overheating and
vibration. Megger test was done.

2. PWO 897012: Engine Room Toilet Exhaust Fan, El. motor fan was checked, no abnormal noise, overheating
and vibration. Megger test was done.

3. PWO 811011: Fire Detection System. Test a sample of detectors and manual call points was done.

4. Maneuvering mode.
5. PWO 713004: ME main lub oil pumps #1,2 checked: no leaks, abnormal noise or heating detected.
Bearings greased.

6. PWO 301047: Hatch Cover, Main Hydraulic Pump No.1, 2 piping, pump during run and system checked, no
leaks and abnormality observed.

C/E Zhylenko S

26.01.2021

DD:

1. Arrival/ Departure Singapore Anchorage C.

2. Maneuvering mode. Passing Singapore straight.


3. Navigational watch and lookout duties.

4. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

5. Cleaning inside the accommodation.


6. Routine Job.

7. Segregation garbage.

8. PWO 503012 - Thermal Protective Aids and Immersion Suits - inspected. All in good condition. Lifebuoys
well marked and in good order. Lifejackets / Immersion Suits self-igniting lights checked. Immersion Suits
zippers well lubricated with petroleum jelly. All expiration dates checked.

Chief Officer / Belo Oleksandr

ED:

1. PWO 792003: E/R Group Alarm Light Column main power circuit regular contact, screws for loose were
checked, dust of the electrical control box was removed.

2. PWP 897022: Windlass Control Room Exhaust Fan, El. motor fan was checked, no abnormal noise,
overheating and vibration. Megger test was done.

3. PWO 897023: Workshop Room Exhaust Fan, El. motor fan was checked, no abnormal noise, overheating
and vibration. Megger test was done.

4. Installed new hour meters on the Incinerator and Fresh Water Generator.

5. Installed on A/E #1 new Exhaust gas sensor No.5 and F.O. Inlet pressure transmitter.

C/E Zhylenko S
27.01.2021

DD:
1. Navigational watch and lookout duties.

2. Daily soundings of ballast tanks and bilges, check temperature in Cargo Holds.

3. Replace STBD Side wire rope on Pilot Gangway. Find Attached Pictures.

4. PWO 301001 - Cargo Hatch Cover Check – Monthly. Inspection of underneath parts of H/Covers was carried
found as follows: all seals in good condition. Hydraulic Pump Unit and Starter in working order. Hydraulic
Hoses and Piping without leakages.

5. PWO 505005 - Safety Gear Checks – Monthly.

6. PWO 505030 - EEBD checks – Monthly.

7. Maneuvering to Prai, Malaysia Outer Anchorage.

Chief Officer / Belo Oleksandr

ED:

1. Marked RH (hour meter) from previous month on Incinerator and Fresh Water Generator.

2. PWO 898004: Emergency Generator Room Supply Fan, El. Motor fan was checked, no abnormal noise,
overheating and vibration. Megger test was done.

3. PWO 898022: Windlass Control Room Exhaust Fan, El. Motor fan was checked, no abnormal noise,
overheating and vibration. Megger test was done.

4. Early PWO 651069: A/E No.2 Governor brush of governor was checked. Normal size, good condition.

5. Changed new one control button of E/R crane.

6. PWO 651046: A/E#2 LO centrifugal filters were cleaned.

7. PWO 572023: Package Air Conditioning Unit for Galley was inspected. Replacement V-belt.

8. PWO 701006: Heavy fuel oil transfer pump was checked for abnormal heating, noise and leakage. All bolts
and nuts were checked for tightening. The pump in good working condition.

9. PWO 7010025: Marine diesel oil transfer pump was checked for abnormal heating, noise and leakage. All
bolts and nuts were checked for tightening. The pump in good working condition.

10. PWO 573001: Package Air Conditioner (ECR) was inspected, tightening V-belt.

11. Maneuvering Mode.

C/E Zhylenko S
28.01.2021

DD:

1. Arrival to inner anchorage of Prai, Malaysia.

2. Cargo /ISPS and anchor watch.

3. Initial Draft Survey.

4. Prepare ship’s equipment for cargo operation.

5. Cleaning inside the accommodation.

Chief Officer / Belo Oleksandr

ED:

1. PWO 866001: Emergency Batteries. M/E MPC battery replacement: EICU-A, EICU-B, ECU-A, ECU-B, ACU-1,
ACU-2, ACU-3. Type of the battery: CR2032; Lion; 225mAh; 20x32mm - 7 pcs. ROB - 7 pcs. M/E RH - 25332

2. PWO 803028: Sludge Pump, El. Motor was lubricated ball bearing, no abnormal noise, overheating and
vibration.

3. PWO 278010: Impressed Current Cathodic Protection (ICCP). Switch off the power, contact Master & Slave
electrical connection boxes (IN ENG.ROOM & FORWARD) checked.

4. PWO 713021: Stern Tube Lube Oil Pump #1 was checked no leaks, no abnormal noise or overheating
observed.

5. PWO 801005: Ballast Pump was checked, Pump checked: no leaks, no abnormal noise or heating detected.

6. PWO 452001: Engine room crane was inspected, lubricated, oil levels checked. Cleaning engine-room.

7. Cleaning engine-room.

C/E Zhylenko S

29.01.2021
DD:

1. Cargo /ISPS and anchor watch.

2. PWO 501023 - Hooks, Release Mechanisms for Rescue Boat, Replace 5 Years. Steel wire ropes renewed
29.01.2021.

3. PWO 501011 - Rescue Boat Davit Check - 5 Yearly. Checked according to the Tasks list. Steel wire ropes
renewed 29.01.2021.
4. PWO 301001 - Cargo Hatch Cover Check - 2 Monthly. Inspection of underneath parts of H/Covers was
carried found as follows: all seals in good condition. Hydraulic Pump Unit and Starter in working order.
Hydraulic Hoses and Piping without leakages.

5. Cleaning and Disinfection inside of accommodation.

6. Ballast Operation.

Chief Officer / Belo Oleksandr

ED:

1. PWO 601003: M/E Cylinder Liner No.1-5, condition of the cylinder liner and lubricating points were
checked. No remarks. On cyl unit #1,2,3 visible light corrosion. Machining marks on the liner surface are
still visible.

2. PWO 601004: M/E Pistons, Piston Rods No.1-5, pistons undersides were checked, cylinder liner inspected
from scav. manifold side and found in good condition: initial honing is still visible, without excessive
deposits, lubrication - optimal, all rings are intact and movable, wear rate appreciated as minimal.

3. Installed new one food waste disposer on the galley.

4. Installed new BNWAS reset units on bridge on Port/Stbd side.

5. PWO 707007: Low Sulphur Marine Gas Oil Transfer Pump, El. motor was checked, no abnormal noise, no
overheating & vibration.

6. PWO 815032: Cargo Hold Smoke Detection System. Checked condition of bottle, pipeline, control panel -
no leakages found. Stop valves are in proper position. Instructions for releasing available & valves in
correct position.

7. Spare cylinder cover overhauling in progress.

8. Spare exhaust valve overhauling in progress. Exhaust valve spindle and seat grinding in progress.

C/E Zhylenko S

30.01.2021
DD:

1. Cargo /ISPS and anchor watch.

2. Cleaning and Disinfection inside of accommodation.

3. Ballast Operation.
4. PWO 151004 - Deck Department Routines – Weekly. Internal communication system - Tested no remarks.
Watertight doors / access - checked no remarks. LB&RB -visually checked /tested no remarks. Fire doors -
checked no remarks. Fixed fire alarm checked -in working order no remarks. Water mist, Water spray and
sprinkler system - visually inspected no remarks, control panel indicators and alarms are functional.
GMDSS and Navigation equipment - without remarks.

5. Routine Job.

Chief Officer / Belo Oleksandr

ED:

1. PWO 288020: Antifouling anodes were inspected and found in good working condition.

2. PWO 331001: Deck crane No.1, 2, 3 & 4 error and warning logs was downloaded.

3. PWO 601060: M/E Crankshaft condition of bearings were checked, oil pan and filters were visually
inspected for bearing metal fragments, any abnormalities were not found.

4. PWO 601069: M/E Control system general inspection for loose bolts and screws was done. Lube oil pipes
for damage, and check jet nozzles for possible stoppages or deformations inspected. The teeth of the chain
wheels checked. The chains for cracks on possibly defective rollers and side plates checked. The chain
wheels, spray nozzles and guide bars checked. Condition of Gear Drive was checked.

5. PWO 722003: Jacket cooling fresh water pump #1 checked: no leaks, abnormal noise or heating detected.

6. PWO 722001: Jacket fresh water pre-pump checked: no leaks, abnormal noise or heating detected.

7. Cleaning engine-room.

8. PWO 151003: Engine Department Routines – Weekly, equipment tested, checked, and found in good
condition. OWS is malfunction.

C/E Zhylenko S

31.01.2021
DD:

Chief Officer / Belo Oleksandr

ED:
1. PWO 601009: ME exhaust valve #4, replaced with spare recondition. ER 18 form created and close.
ME RH 25332.

2. Spare exhaust valve overhauling in progress. Exhaust valve spindle and seat grinding in progress.

3. On board lub oil test carried out.

C/E Zhylenko S