Moment capacity calculations for ULS of 200 mm thick slab Top and Botom Mesh with 40mm cover
Moment capacity of main top and bottom reinforcement of 200 mm thick Slab --

Thickness of Slab, D = 200 mm


Width of Slab, b = 1000 mm
Diametre of reinforcement, = 10 mm
Clear cover to reinforcement, dc = 40 mm
Effective depth, d = 155 mm
2
Yield Stress of reinforcement, fyk = 500 N/mm
2
Grade of Concrete, fck = 28 N/mm
2
fctm = 2.77 N/mm

Moment Capacity= 33 kN.m


2
K = Mu / (b.d .fck) = 0.049
K' = 0.167 (Assuming no distribution of moment)
K < K' Compression reinforcement not required

Leverarm, z = d [0.5+(0.25 - K/1.134)1/2] = 147.98 mm


0.95 d = 147.25 mm
Leverarm considered for design, z = 147.25 mm

Minimum area of steel As,min = 0.26(fctm/fyk).bt.d > 0.13%bd


= 223.26 mm
Area of steel required, Asr= [ Mu / (0.87 . fyk .z) ] =
2
515.19 mm
Reinforcement Provided =

Diameter of reinforcement, = 10 0 0
Spacing of reinforcement, s = 150 200 200 -
Area of steel provided, Asp = 523.60 0.00 0.00 -
Total Area of steel provided 523.60 SAFE

71
132/11kV WADI ABA SALEEL-1 S/S Date : 11.12.22
Part : Main Building Prepared By : SAR
Job No : GTC/735A/2015 Checked By : MIM
Title : Super Structure Approved By: VRP

Moment capacity of Secondary top and bottom secondary reinforcement of 200 mm thick Slab --

Thickness of Slab, D = 200 mm


Width of Slab, b = 1000 mm
Diametre of reinforcement, = 10 mm
Clear cover to reinforcement, dc = 50 mm
Effective depth, d = 145 mm
2
Yield Stress of reinforcement, fyk = 500 N/mm
2
Grade of Concrete, fck = 28 N/mm
2
fctm = 2.77 N/mm

Moment Capacity= 26 kN.m


2
K = Mu / (b.d .fck) = 0.044
K' = 0.167 (Assuming no distribution of moment)
K < K' Compression reinforcement not required

Leverarm, z = d [0.5+(0.25 - K/1.134)1/2] = 139.11 mm


0.95 d = 137.75 mm
Leverarm considered for design, z = 137.75 mm

Minimum area of steel As,min = 0.26(fctm/fyk).bt.d > 0.13%bd


= 208.86 mm
Area of steel required, Asr= [ Mu / (0.87 . fyk .z) ] =
2
433.90 mm
Reinforcement Provided =

Diameter of reinforcement, = 10 0 0
Spacing of reinforcement, s = 175 200 200 -
Area of steel provided, Asp = 448.80 0.00 0.00 -
Total Area of steel provided 448.80 SAFE

72
132/11kV WADI ABA SALEEL-1 S/S Date : 11.01.23
Part : Main Building Prepared By : SAR
Job No : GTC/735A/2015 Checked By : MIM
Title : Super Structure Approved By: VRP

Moment capacity calculations for ULS of 200 mm thick slab Top and Botom Mesh with 40mm cover
Moment capacity of main top and bottom reinforcement of 200 mm thick Slab --

Thickness of Slab, D = 200 mm


Width of Slab, b = 1000 mm
Diametre of reinforcement, = 10 mm
Clear cover to reinforcement, dc = 40 mm
Effective depth, d = 155 mm
Yield Stress of reinforcement, fyk = 500 N/mm2
Grade of Concrete, fck = 28 N/mm2
fctm = 2.77 N/mm2

Moment Capacity= 62 kN.m


K = Mu / (b.d2.fck) = 0.092
K' = 0.167 (Assuming no distribution of moment)
K < K' Compression reinforcement not required

Leverarm, z = d [0.5+(0.25 - K/1.134)1/2] = 141.17 mm


0.95 d = 147.25 mm
Leverarm considered for design, z = 141.17 mm

Minimum area of steel As,min = 0.26(fctm/fyk).bt.d > 0.13%bd


= 223.26 mm
Area of steel required, Asr= [ Mu / (0.87 . fyk .z) ] =
1009.64 mm2
Reinforcement Provided =

Diameter of reinforcement, = 10 10 0
Spacing of reinforcement, s = 150 150 200 10@150 Extra
Area of steel provided, Asp = 523.60 523.60 0.00 -
Total Area of steel provided 1047.20 SAFE

73
132/11kV WADI ABA SALEEL-1 S/S Date : 11.01.23
Part : Main Building Prepared By : SAR
Job No : GTC/735A/2015 Checked By : MIM
Title : Super Structure Approved By: VRP

Moment capacity of secondary top and bottom secondary reinforcement of 200 mm thick Slab --

Thickness of Slab, D = 200 mm


Width of Slab, b = 1000 mm
Diametre of reinforcement, = 10 mm
Clear cover to reinforcement, dc = 50 mm
Effective depth, d = 145 mm
Yield Stress of reinforcement, fyk = 500 N/mm2
Grade of Concrete, fck = 28 N/mm2
fctm = 2.77 N/mm2

Moment Capacity= 50 kN.m


K = Mu / (b.d2.fck) = 0.085
K' = 0.167 (Assuming no distribution of moment)
K < K' Compression reinforcement not required

Leverarm, z = d [0.5+(0.25 - K/1.134)1/2] = 133.18 mm


0.95 d = 137.75 mm
Leverarm considered for design, z = 133.18 mm

Minimum area of steel As,min = 0.26(fctm/fyk).bt.d > 0.13%bd


= 208.86 mm
Area of steel required, Asr= [ Mu / (0.87 . fyk .z) ] =
863.09 mm2
Reinforcement Provided =

Diameter of reinforcement, = 10 10 0
Spacing of reinforcement, s = 175 175 200 10@175 Extra
Area of steel provided, Asp = 448.80 448.80 0.00 -
Total Area of steel provided 897.60 SAFE

74
ETABS 17.0.1 1/11/2023

200thk Slab Bottom Main Direction


1 2 3 4 5 6 7 8 9

A X

-20.0 -15.9 -11.8 -7.8 -3.7 0.4 4.5 8.5 12.6 16.7 20.8 24.8 28.9 33.0
Wadi 10.01.23.EDB Plan View - Lower Roof - Z = 7.23 (m) Resultant M22 Diagram (ULS) [kN-m/m]

75
ETABS 17.0.1 1/11/2023

200thk Slab Bottom Main Direction


1 2 3 4 5 6 7 8 9

Bottom Main reinforcement 10@150 capacity 33 kN-m Beyond 33 kN-m moments are not developing. So further extra reinforcement not
Y
required.

A X

33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0 33.0
Wadi 10.01.23.EDB Plan View - Lower Roof - Z = 7.23 (m) Resultant M22 Diagram (ULS) [kN-m/m]

76
ETABS 17.0.1 1/11/2023

200thk Slab Bottom Secondary Direction


1 2 3 4 5 6 7 8 9

A X

-50.0 -44.2 -38.3 -32.5 -26.6 -20.8 -14.9 -9.1 -3.2 2.6 8.5 14.3 20.2 26.0
Wadi 10.01.23.EDB Plan View - Lower Roof - Z = 7.23 (m) Resultant M11 Diagram (ULS) [kN-m/m]

77
ETABS 17.0.1 1/11/2023

200thk Slab Bottom Secondary Direction


1 2 3 4 5 6 7 8 9

Bottom Secondary reinforcement 10@175 capacity 26 kN-m Beyond 26 kN-m moments are not developing. So further extra reinforcement not
Y
required.

A X

26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0
Wadi 10.01.23.EDB Plan View - Lower Roof - Z = 7.23 (m) Resultant M11 Diagram (ULS) [kN-m/m]

78
ETABS 17.0.1 1/11/2023

200thk Slab Top Main Direction


1 2 3 4 5 6 7 8 9

A X

-33.0 -28.2 -23.3 -18.5 -13.6 -8.8 -3.9 0.9 5.8 10.6 15.5 20.3 25.2 30.0
Wadi 10.01.23.EDB Plan View - Lower Roof - Z = 7.23 (m) Resultant M22 Diagram (ULS) [kN-m/m]

79
ETABS 17.0.1 1/11/2023

200thk Slab Top Main Direction


1 2 3 4 5 6 7 8 9

Top Main reinforcement 10@150


Y capacity 33 kN-m Beyond 33 kN-m moments are not developing. So further extra reinforcement not required.

A X

-33.0 -33.0 -33.0 -33.0 -33.0 -33.0 -33.0 -33.0 -33.0 -33.0 -33.0 -33.0 -33.0 -33.0
Wadi 10.01.23.EDB Plan View - Lower Roof - Z = 7.23 (m) Resultant M22 Diagram (ULS) [kN-m/m]

80
ETABS 17.0.1 1/11/2023

200thk Slab Top Secondary Direction


1 2 3 4 5 6 7 8 9

A X

-50.0 -44.6 -39.2 -33.8 -28.5 -23.1 -17.7 -12.3 -6.9 -1.5 3.8 9.2 14.6 20.0
Wadi 10.01.23.EDB Plan View - Lower Roof - Z = 7.23 (m) Resultant M11 Diagram (ULS) [kN-m/m]

81
ETABS 17.0.1 1/11/2023

200thk Slab Top Secondary Direction


1 2 3 4 5 6 7 8 9

Top Secondary reinforcement 10@175 capacity 26 kN-m Beyond 26 kN-m moments are developing. So extra reinforcement provided
in highlighlited portions Y

A X

-50.0 -48.2 -46.3 -44.5 -42.6 -40.8 -38.9 -37.1 -35.2 -33.4 -31.5 -29.7 -27.8 -26.0
Wadi 10.01.23.EDB Plan View - Lower Roof - Z = 7.23 (m) Resultant M11 Diagram (ULS) [kN-m/m]

82
ETABS 17.0.1 1/11/2023

200thk Slab Top Secondary Direction


1 2 3 4 5 6 7 8 9

Top Secondary reinforcementY 10@175+10@175 capacity 50 kN-m Beyond 50 kN-m no moments are developing. So further extra reinforcement not
required.

A X

-50.0 -50.0 -50.0 -50.0 -50.0 -50.0 -50.0 -50.0 -50.0 -50.0 -50.0 -50.0 -50.0 -50.0
Wadi 10.01.23.EDB Plan View - Lower Roof - Z = 7.23 (m) Resultant M11 Diagram (ULS) [kN-m/m]