You are on page 1of 4

»ÎÊÊ»ÆƘ

»ÎÊ »Ä»È·Ê¿ÅÄƘ
MultiBloc® MBE
MultiBloc® MBE
Generation “E”
Construction kit: ValveDrive + ValveBody = MBE

ValveDrive ValveDrive Pressure sensor* ValveBody MultiBloc®


VD-V VD-R PS- ... VB-... MBE-...

*only with VD-R

MultiBloc® ValveDrive VD
Pressure Sensor ĻȽÏ»ů¹¿»ÄʷĺżÊÉÊ·ÈÊƭ ·ÉÊɾËÊƖÅŮ̐ʸÉ

PS … Range ·Â̻ȿ̻ƖƔƔƔ
PS-50/200 ʹƯʼʷÁ· Ɩ ·¼»ÊÏɾËÊƖÅŮƑÍÅÈÁÉͿʾ»Ì»ÈϸËÈÄ»È
20 – 500 mbar control.
8 – 200" w.c.
PS-10/40 ʷƑʻƯʸʷÁ·
4 – 100 mbar
1.5 – 40" w.c.
PS-0 ʷ̌ʹÁ· Ɩ ·¼»ÊÏɾËÊƖÅŮͿʾ¿ÄÊ»½È·Ê»ºÆÈ»ÉÉËÈ»
zero governor 0 ± 20 mbar È»½Ë·ÊÅÈƑÍÅÈÁÉͿʾ»Ì»ÈϸËÈĻȹÅÄÊÈÅÂƔ
0 ± 8" w.c. Pressure sensor PS mandatory.

MultiBloc®
Generation E
ValveDrive VD
ƖƔƔƔ Thread p÷ÎƔ
Flange Features
ʽʷÁ·
Rp 2 ·Â̻ȿ̻ƖƔƔƔ
VB-050/2 600 mbar
NPT 2
8 PSI Status LED Blue LED indicates the energized actuator.

DN 65
VB-065/2.5 Visual Indicator »ºŲ·½ƑÌ¿É¿¸Â»;»ÄÅƻĿĽƭÈ»½Ë·ʿĽ
NPS 2 ½

DN 80 Proof of closure All VDs are available with and without


VB-080/3
NPS 3 (POC) switch POC function.
ʾʷÁ·
DN 100 Electrical EN 175301-803 plug-connector. Space
VB-100/4 700 mbar
NPS 4 connection requirements of oversized connectors are
10 PSI
considered.
DN 125
VB-125/5
NPS 5 ÎÎ IP 54/NEMA 13
ÎÎ IP 65/NEMA 4 under investigation
DN 150
VB-150/6
NPS 6

8 Dungs
¿Î»ºÅƻĿĽʿû
• No temperature impact to regulation
• electronic controlled opening and closing
behaviour

Wide operating
Standard M12, temperature range
5 pin connector • Applicable at very low
ambient temperatures
• No impact to functional behaviour (e.g.
pressure control)

Works at low
temperatures

-20 °C / -4
4 °F to +60 °C / -140 °F

-4 °F +32 °F +140 °F
-20 °C 0 °C + 60 °C
ValveDrive VD Robust Design
Universal power supply • No regulator spring
ʸʷʷƯʹʻʷʤʼʷƭʽʷ Ð • No membrane
• No nozzles
• No oil

Fits everywhere …

red = 115 –120 VAC @ 60 Hz


blue = 220 – 240 VAC @ 50/60 Hz
green = 100 VAC / 50 Hz
yellow = 200 VAC / 50 Hz
Pressure setting
Intelligent pressure control with adjustment dial,
ɷûÊÅÅ·ÉÊÅŰÎ
Getting things done … the actuators

Flexible
“electric”
impulse
line

As awarded by
The Chicago Athenaeum:
Museum of Architecture
and Design.

MBE Pressure Control Pressure Sensor PS


• Temperature compensated • Variable pressure sensing point • VD-R and PS according to EN
electronic pressure sensing to adapt to application 88-1
• Adaptive digital control algorithm • Smooth pressure ramp-up • Outlet presure is limited by max./
• ÅÊ·Ů»¹Ê»º¸ÏÊ»ÃƻȷÊËÈ» during startup min. pressure switches in the
• ÅÊ·Ů»¹Ê»º¸Ï·½»¿Ä½ • No internal nozzles, greater application in accordance to
• Excellent repeatability tolerance to contamination EN 676 (Forced draught burner
standard)

Flanged
Threaded connection
connection DN, NPS, JIS ¿½¾Ų»Î¿¸¿Â¿ÊÏʾÈÅ˽¾
NPT or Rp easy commissioning
by customer
Universal AC
power supply
100 – 240 VAC High capacity

Worldwide approvals:
CE, UL, CSA,
One world Energy
»ů¹¿»ÄÊ
FM, AUS, EAC
(pending) One valve Lightweight
design

Modular platform
»ο¸Â»»Â»¹ÊÈ¿¹
Printed in Germany • 2017-03 • 275 589

Karl Dungs GmbH & Co. KG “impulse line”


Siemensstraße 6 – 10 Regulator
with pressure Mechatronic
73660 Urbach, Germany
sensor design
Telefon +49 7181 804-0
Telefax +49 7181 804-166
info@dungs.com