150

2R16

225

R16
R16
2R20
R10

750
6R1601

75 kicker
4-R2001 R10@200c/c
+ 2-R1601

400
R16

R16
B.R.C MESH No.A142 2R16

150
600
450

10-R1001-200 C/C

10-R1000-200 C/C
2R20
150
A A
850
1500

2R16 SECT. C - C
C1a R16
2R16 R16 C3 R16
SECT. B - B
600

225
50

R20 R20 R20


2R20 R20@125

700

700
8R1601 4-R2001 + 2R1601
R16

22- R1604-150c/c TB
R16

R10
650

26- R2003-125c/c BB

75

75
BRC Mesh A142 BRC Mesh A142
400

2R16

450 150

450 150
R10 3400

600

600
2R20 NOTE 1 :
2R16 Concrete to frames
2
SECT. A - A must be fcu -25N/mm
10-R1002-200 10-R1001-200

950

950
Reinforcement TO BEAMS

1500

1500
B B C C 2
Fy - 250N/mm - Mild Steel bars
1800

C5 C1a
Cover to reinforcement

500

500
Foundations -50mm
Columns -40mm
F4 1450 12- R1600-150c/c TB 50mm blinding
50mm blinding
15- R2000-125c/c BB slab - 25mm
Staircase - 25mm
3400
Beams -25mm

650
150

12- R2003-150c/c BB
Client :

C3 LOIS BOATENG
2250

12- R2003-150c/c BB
C1a

2250
3400

1450

Project :
650

C3
1800

400

4- STOREY RESIDENTIAL FACILITY


Location :

225 BORTIANOR-ACCRA
225

150
C1a Description :
R.C FOOTINGS
400
F4 1450 15- R2002-150c/c BB
15- R2002-150c/c BB AD-CONSULT
F4 1800
Structural engineer :

1800 FREDERICK OWUSU-ADDO (ING.)

Drawn by :
1800 Sheet No.

F5;C5(1no) F5;C1a (1no) Scale :

Date :
1:100 5
MARCH, 2023