XLSEMI Datasheet

2.1A 100KHz 90V Buck DC to DC Converter XL7056

Features General Description


„ Operation Voltage from 8V to 80V The XL7056 is a 100KHz fixed frequency
„ Maximum Duty Cycle up to 85% PWM buck (step-down) DC/DC converter,
„ Minimum Drop Out 2.0V capable of driving a 2.1A load with high
„ Adjust VOUT from 1.25V to 20V efficiency, low ripple and excellent line and
„ Max. IOUT=2.1A at VOUT=5V load regulation. Requiring a minimum
„ Max. IOUT=1.2A at VOUT=15V number of external components, the regulator
„ Fixed 100KHz Switching Frequency is simple to use and include internal
„ Max. Output power less than 20W frequency compensation and a
„ Internal Optimize HV Power MOSFET fixed-frequency oscillator.
„ High efficiency up to 93%
„ Excellent line and load regulation The PWM control circuit is able to adjust the
„ Built in current limit function duty ratio linearly from 0 to 85%.
„ Built in output short Protection Function
„ TO263-7L package

Applications
„ Ebike Controller Power Supply
„ Telecom / Networking Equipment

Figure1. Package Type of XL7056

Rev 1.2 www.xlsemi.com


1
XLSEMI Datasheet

2.1A 100KHz 90V Buck DC to DC Converter XL7056

Pin Configurations

Figure2. Pin Configuration of XL7056 (Top View)

Table 1 Pin Description

Pin Number Pin Name Description


Ground Pin. Care must be taken in layout. This pin should be
placed outside of the Schottky Diode to output capacitor ground
1 GND
path to prevent switching current spikes from inducing voltage
noise into XL7056.
Feedback Pin (FB). Through an external resistor divider
2 FB network, Feedback senses the output voltage and regulates it.
The feedback threshold voltage is 1.25V.
3 CSN Current Sense Negative Terminal.
Power Switch Output Pin (SW). Output is the switch node that
4 SW
supplies power to the output. The Metal is SW.
5 CSP Current Sense Positive Terminal.
Internal Voltage Regulator Bypass Capacity. In typical system
6 VC
application, The VC pin connect a 1uF capacitor to VIN.
Supply Voltage Input Pin. XL7056 operates from 8V to 80V DC
7 VIN voltage. Bypass Vin to GND with a suitably large capacitor to
eliminate noise on the input.

Rev 1.2 www.xlsemi.com


2
XLSEMI Datasheet

2.1A 100KHz 90V Buck DC to DC Converter XL7056

Function Block

Figure3. Function Block Diagram of XL7056


Typical Application Circuit

CSN CSP R3
3 5 L1 100uH/3A 0.035Ω 1%
VIN SW
7 4

R2
CC XL7056 D1
CFF
C2 COUT 10K 10nF
105 FSV10150 1%
CIN C1 105 220uF
VC
100uF 104 6 /16V
VIN FB VOUT
2
10V~80V /100V 1 5V/0~2.1A
GND
R1
3.3K
1%

INPUT 10V~80V
OUTPUT 5V/0~2.1A
VOUT=1.25*(1+R2/R1)

R3 for limit maximum output current, R3 choose 0.035ohm in VOUT≤5V application; R3


choose 0.055ohm in VOUT>5V application.
Figure4. XL7056 Typical Application Circuit

Rev 1.2 www.xlsemi.com


3
XLSEMI Datasheet

2.1A 100KHz 90V Buck DC to DC Converter XL7056

Ordering Information
Order Information Marking ID Package Type Packing Type Supplied As
XL7056E1 XL7056E1 TO263-7L 800 Units on Tape & Reel
XLSEMI Pb-free products, as designated with “E1” suffix in the par number, are RoHS compliant.

Absolute Maximum Ratings(Note1)


Parameter Symbol Value Unit
VIN Pin Voltage VIN -0.3 to 90 V
FB Pin Voltage VFB -0.3 to 5 V
SW Pin Voltage VSW -0.3 to VIN V
Power Dissipation PD Internally limited mW
Thermal Resistance (TO263-7L)
RJA 30 ºC/W
(Junction to Ambient, No Heatsink, Free Air)
Maximum Junction Temperature TJ -40 to 150 ºC
Operating Junction Temperature TJ -40 to 125 ºC
Storage Temperature TSTG -65 to 150 ºC
Lead Temperature (Soldering, 10 sec) TLEAD 260 ºC
ESD (HBM) >3000 V

Note1: Stresses greater than those listed under Maximum Ratings may cause permanent damage
to the device. This is a stress rating only and functional operation of the device at these or any
other conditions above those indicated in the operation is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect reliability.

Rev 1.2 www.xlsemi.com


4
XLSEMI Datasheet

2.1A 100KHz 90V Buck DC to DC Converter XL7056

XL7056 Electrical Characteristics


Ta = 25℃;unless otherwise specified.
Symbol Parameter Test Condition Min. Typ. Max. Unit
System parameters test circuit figure4
Vin =20V to 80V,Vout=15V
VFB FB Voltage 1.225 1.25 1.275 V
Iload=0.5A
Vin=24V, Vout=15V
ŋ Efficiency - 95 - %
Iout=1.2A
Vin=36V, Vout=15V
ŋ Efficiency - 94 - %
Iout=1.2A
Vin=48V, Vout=15V
ŋ Efficiency - 93 - %
Iout=1.2A
Vin=60V, Vout=15V
ŋ Efficiency - 92 - %
Iout=1.2A
Vin=72V, Vout=15V
ŋ Efficiency - 91 - %
Iout=1.2A
Electrical Characteristics (DC Parameters)
Vin = 48V, GND=0V, Vin & GND parallel connect a 47uf/100V capacitor; Iout=0.2A, Ta =
25℃; the others floating unless otherwise specified.
Parameters Symbol Test Condition Min. Typ. Max. Unit
Input operation voltage Vin 80 V
VIN UVLO Vin_uvlo 6 V

Quiescent Supply Current Iq VFB =2V 2.1 5 mA

Oscillator Frequency Fosc 75 100 135 KHz


VFB=0,
Switch Current Limit IL 2.3 A
R3=0.035Ω
VIN=48V,
Output Power PMOS Rdson 260 mohm
ISW=1.0A

Rev 1.2 www.xlsemi.com


5
XLSEMI Datasheet

2.1A 100KHz 90V Buck DC to DC Converter XL7056

Typical Performance Characteristics

Quiescent Supply Current VS Temperature


5
Quiescent Supply Current(mA)

4 VIN=48V

0
-50 -25 0 25 50 75 100 125

Temperature(℃)

Figure5. Quiescent Current Curve

Feedback Voltage Change VS Temperature


3.0

2.5

2.0
VIN=48V,VOUT=5V,IOUT=0.1A
Feedback Voltage Change(%)

1.5 Normalized at TA=25℃


1.0

0.5

0.0

-0.5

-1.0

-1.5

-2.0

-2.5

-3.0
-50 -25 0 25 50 75 100 125

Temperature(℃)

Figure6. Feedback Voltage Curve

Rev 1.2 www.xlsemi.com


6
XLSEMI Datasheet

2.1A 100KHz 90V Buck DC to DC Converter XL7056

Typical System Application (VOUT=15V, IOUT=0~1.2A)

CSN CSP R3
3 5 L1 100uH/2A 0.055Ω 1%
VIN SW
7 4

R2
CC XL7056 D1
CFF
C2 COUT 30K 10nF
105 FSV10150 1%
CIN C1 105 100uF
VC
100uF 104 6 /35V
VIN FB VOUT
2
20V~80V /100V 1 15V/0~1.2A
GND
R1
2.7K
1%

INPUT 20V~80V
OUTPUT 15V/0~1.2A
VOUT=1.25*(1+R2/R1)

Figure7. XL7056 System Application (VIN=20V~80V, VOUT=15V, IOUT=0~1.2A)

Efficiency VS Output current


100
95
90
85
80
75
70
Efficiency(%)

65
60
55 VIN=24V,VOUT=15V,IOUT=0.1A~1.2A
50 VIN=36V,VOUT=15V,IOUT=0.1A~1.2A
45 VIN=48V,VOUT=15V,IOUT=0.1A~1.2A
40 VIN=60V,VOUT=15V,IOUT=0.1A~1.2A
35 VIN=72V,VOUT=15V,IOUT=0.1A~1.2A
30
25
20
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2
Output current(A)

Figure8. XL7056 System Application (Efficiency VS Output Current)

Rev 1.2 www.xlsemi.com


7
XLSEMI Datasheet

2.1A 100KHz 90V Buck DC to DC Converter XL7056

Typical System Application (VOUT=5V, IOUT=0~2.1A)

CSN CSP R3
3 5 L1 100uH/3A 0.035Ω 1%
VIN SW
7 4

R2
CC XL7056 D1
CFF
C2 COUT 10K 10nF
105 FSV10150 1%
CIN C1 105 220uF
VC
100uF 104 6 /16V
VIN FB VOUT
2
10V~80V /100V 1 5V/0~2.1A
GND
R1
3.3K
1%

INPUT 10V~80V
OUTPUT 5V/0~2.1A
VOUT=1.25*(1+R2/R1)

Figure9. XL7056 System Application (VIN=10V~80V, VOUT=5V, IOUT=0~2.1A)

Efficiency VS Output current


95
90
85
80
75
70
65
Efficiency(%)

60
55 VIN=12V,VOUT=5V,IOUT=0.1A~2.1A
50 VIN=24V,VOUT=5V,IOUT=0.1A~2.1A
45 VIN=36V,VOUT=5V,IOUT=0.1A~2.1A
40 VIN=48V,VOUT=5V,IOUT=0.1A~2.1A
35 VIN=60V,VOUT=5V,IOUT=0.1A~2.1A
30
VIN=72V,VOUT=5V,IOUT=0.1A~2.1A
25
20
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1
Output current(A)

Figure10. XL7056 System Application (Efficiency VS Output Current)

Rev 1.2 www.xlsemi.com


8
XLSEMI Datasheet

2.1A 100KHz 90V Buck DC to DC Converter XL7056

Typical System Application (VOUT=3.3V, IOUT=0~2.1A)

CSN CSP R3
3 5 L1 100uH/3A 0.035Ω 1%
VIN SW
7 4

R2
CC XL7056 D1
CFF
C2 COUT 13.7K 10nF
105 FSV10150 1%
CIN C1 105 220uF
VC
100uF 104 6 /16V
VIN FB VOUT
2
8V~80V /100V 1 3.3V/0~2.1A
GND
R1
8.2K
1%

INPUT 8V~80V
OUTPUT 3.3V/0~2.1A
VOUT=1.25*(1+R2/R1)

Figure11. XL7056 System Application (VIN=8V~80V, VOUT=3.3V, IOUT=0~2.1A)

Efficiency VS Output current


90
85
80
75
70
65
60
Efficiency(%)

55
50 VIN=12V,VOUT=3.3V,IOUT=0.1A~2.1A
45 VIN=24V,VOUT=3.3V,IOUT=0.1A~2.1A
40 VIN=36V,VOUT=3.3V,IOUT=0.1A~2.1A
35 VIN=48V,VOUT=3.3V,IOUT=0.1A~2.1A
30 VIN=60V,VOUT=3.3V,IOUT=0.1A~2.1A
25
VIN=72V,VOUT=3.3V,IOUT=0.1A~2.1A
20
15
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1
Output current(A)

Figure12. XL7056 System Application (Efficiency VS Output Current)

Rev 1.2 www.xlsemi.com


9
XLSEMI Datasheet

2.1A 100KHz 90V Buck DC to DC Converter XL7056

Package Information
Package Information (TO263-7L)
H1

Dimensions In Millimeters Dimensions In Inches


字符
Min Max Min Max
A 4.25 4.55 0.167 0.179
A1 1.20 1.40 0.047 0.055
B 0.50 0.70 0.020 0.028
B1 0.58 0.84 0.023 0.033
C 0.40 0.60 0.016 0.024
D 9.05 9.45 0.356 0.372
E 9.80 10.20 0.386 0.402
e 1.27(BSC) 0.050(BSC)
H 14.65 15.35 0.577 0.604
H1 0.80 1.20 0.031 0.047

Rev 1.2 www.xlsemi.com


10
XLSEMI Datasheet

2.1A 100KHz 90V Buck DC to DC Converter XL7056

Important Notice
XLSEMI reserve the right to make modifications, enhancements, improvements, corrections or
other changes without notice at any time. XLSEMI does not assume any liability arising out of
the application or use of any product described herein; neither does it convey any license under
its patent rights, nor the rights of others. XLSEMI assumes no liability for applications assistance
or the design of Buyers’ products. Buyers are responsible for their products and applications
using XLSEMI components. To minimize the risks associated with Buyers’ products and
applications, Buyers should provide adequate design and operating safeguards. XLSEMI
warrants performance of its products to the specifications applicable at the time of sale, in
accordance with the warranty in XLSEMI’s terms and conditions of sale of semiconductor
products. Testing and other quality control techniques are used to the extent XLSEMI deems
necessary to support this warranty. Except where mandated by applicable law, testing of all
parameters of each component is not necessarily performed.
For the latest product information, go to www.xlsemi.com.

Rev 1.2 www.xlsemi.com


11

You might also like