You are on page 1of 14

SIMATIC Elevator\SIMATIC 300(1)\CPU 312\...

\OB1 - <offline> 09/16/2018 12:40:15 PM

OB1 - <offline>
""
Name: Family:
Author: Version: 0.1
Block version: 2
Time stamp Code: 09/14/2018 10:30:21 PM
Interface: 02/15/1996 04:51:12 PM
Lengths (block/logic/data): 01266 01056 00020

Name Data Type Address Comment


TEMP 0.0
OB1_EV_CLASS Byte 0.0 Bits 0-3 = 1 (Coming event), Bits 4-7 = 1 (Event class 1)
OB1_SCAN_1 Byte 1.0 1 (Cold restart scan 1 of OB 1), 3 (Scan 2-n of OB 1)
OB1_PRIORITY Byte 2.0 Priority of OB Execution
OB1_OB_NUMBR Byte 3.0 1 (Organization block 1, OB1)
OB1_RESERVED_1 Byte 4.0 Reserved for system
OB1_RESERVED_2 Byte 5.0 Reserved for system
OB1_PREV_CYCLE Int 6.0 Cycle time of previous OB1 scan (milliseconds)
OB1_MIN_CYCLE Int 8.0 Minimum cycle time of OB1 (milliseconds)
OB1_MAX_CYCLE Int 10.0 Maximum cycle time of OB1 (milliseconds)
OB1_DATE_TIME Date_And_Time 12.0 Date and time OB1 started

Block: OB1 "Main Program Sweep (Cycle)"

Network: 1

start to ground floor

M0.0 I0.0 Q0.1

Q0.1

Network: 2

C1
I0.1 Q0.0 S_CUD
CU Q
I0.1 Q0.1 CV MW10
CD
CV_BCD
S

PV

I0.0 R

Page 1 of 14
SIMATIC Elevator\SIMATIC 300(1)\CPU 312\...\OB1 - <offline> 09/16/2018 12:40:15 PM

Network: 3

G floor sensor

CMP ==I M0.1


S

MW10 IN1 M0.2


R
0 IN2
M0.3
R
M0.4
R
M0.5
R
M0.6
R
M0.7
R

Network: 4

1 floor sensor

CMP ==I M0.2


S

MW10 IN1 M0.1


R
1 IN2
M0.3
R
M0.4
R
M0.5
R
M0.6
R
M0.7
R

Network: 5

2 floor sensor

CMP ==I M0.3


S

MW10 IN1 M0.1


R
2 IN2
M0.2
R
M0.4
R
M0.5
R
M0.6
R
M0.7
R

Page 2 of 14
SIMATIC Elevator\SIMATIC 300(1)\CPU 312\...\OB1 - <offline> 09/16/2018 12:40:15 PM

Network: 6

3 floor sensor

CMP ==I M0.4


S

MW10 IN1 M0.1


R
3 IN2
M0.2
R
M0.3
R
M0.5
R
M0.6
R
M0.7
R

Network: 7

4 floor sensor

CMP ==I M0.5


S

MW10 IN1 M0.1


R
4 IN2
M0.2
R
M0.3
R
M0.4
R
M0.6
R
M0.7
R

Network: 8

5 floor sensor

CMP ==I M0.6


S

MW10 IN1 M0.1


R
5 IN2
M0.2
R
M0.3
R
M0.4
R
M0.5
R
M0.7
R

Page 3 of 14
SIMATIC Elevator\SIMATIC 300(1)\CPU 312\...\OB1 - <offline> 09/16/2018 12:40:15 PM

Network: 9

6 floor sensor

CMP ==I M0.7


S

MW10 IN1 M0.1


R
6 IN2
M0.2
R
M0.3
R
M0.4
R
M0.5
R
M0.6
R

Network: 10

maintenance(1)

M1.0 M1.1

Network: 11

maintenance(2)

M1.2 M1.3

Network: 12

G Floor Call

M3.0 M1.1 M5.0


S
M4.0 M1.1

Network: 13

M0.1 M5.0 M13.7 M5.0


R

Page 4 of 14
SIMATIC Elevator\SIMATIC 300(1)\CPU 312\...\OB1 - <offline> 09/16/2018 12:40:15 PM

Network: 14

1 Floor Call

M3.1 M1.1 M5.1


S
M4.1 M1.1

Network: 15

M0.2 M5.1 M13.7 M5.1


R

Network: 16

2 Floor Call

M3.2 M1.1 M5.2


S
M4.2 M1.1

Network: 17

M0.3 M5.2 M13.7 M5.2


R

Network: 18

3 Floor Call

M3.3 M1.1 M5.3


S
M4.3 M1.1

Network: 19

M0.4 M5.3 M13.7 M5.3


R

Page 5 of 14
SIMATIC Elevator\SIMATIC 300(1)\CPU 312\...\OB1 - <offline> 09/16/2018 12:40:15 PM

Network: 20

4 Floor Call

M3.4 M1.1 M5.4


S
M4.4 M1.1

Network: 21

M0.5 M5.4 M13.7 M5.4


R

Network: 22

5 Floor Call

M3.5 M1.1 M5.5


S
M4.5 M1.1

Network: 23

M0.6 M5.5 M13.7 M5.5


R

Network: 24

6 Floor Call

M3.6 M1.1 M5.6


S
M4.6 M1.1

Network: 25

M0.7 M5.6 M13.7 M5.6


R

Page 6 of 14
SIMATIC Elevator\SIMATIC 300(1)\CPU 312\...\OB1 - <offline> 09/16/2018 12:40:16 PM

Network: 26

motor up

M0.1 M5.1 Q0.0


S
M5.2 Q0.1
R
M5.3

M5.4

M5.5

M5.6

Network: 27

motor up

M0.2 M5.2 M5.0 Q0.0


S
M5.3 M5.0 M13.0 Q0.1
R
M5.4

M5.5

M5.6

Network: 28

motor up

M0.3 M5.3 M5.0 M5.1 Q0.0


S
M5.4 M5.0 M13.0 Q0.1
R
M5.5 M5.1 M13.1

M5.6

Page 7 of 14
SIMATIC Elevator\SIMATIC 300(1)\CPU 312\...\OB1 - <offline> 09/16/2018 12:40:16 PM

Network: 29

motor up

M0.4 M5.4 M5.0 M5.1 M5.2 Q0.0


S
M5.5 M5.0 M13.0 Q0.1
R
M5.6 M5.1 M13.1

M5.2 M13.2

Network: 30

motor up

M0.5 M5.5 M5.0 M5.1 M5.2 M5.3 Q0.0


S
M5.6 M5.0 M13.0 Q0.1
R
M5.1 M13.1

M5.2 M13.2

M5.3 M13.3

Network: 31

motor up

M0.6 M5.6 M5.0 M5.1 M5.2 M5.3 M5.4 Q0.0


S
M5.0 M13.0 Q0.1
R
M5.1 M13.1

M5.2 M13.2

M5.3 M13.3

M5.4 M13.4

Page 8 of 14
SIMATIC Elevator\SIMATIC 300(1)\CPU 312\...\OB1 - <offline> 09/16/2018 12:40:16 PM

Network: 32

motor down

M0.7 M5.0 Q0.1


S
M5.1 Q0.0
R
M5.2

M5.3

M5.4

M5.5

Network: 33

motor down

M0.6 M5.0 M5.6 Q0.1


S
M5.1 M5.6 M13.6 Q0.0
R
M5.2

M5.3

M5.4

Network: 34

motor down

M0.5 M5.0 M5.5 M5.6 Q0.1


S
M5.1 M5.5 M13.5 Q0.0
R
M5.2 M5.6 M13.6

M5.3

Page 9 of 14
SIMATIC Elevator\SIMATIC 300(1)\CPU 312\...\OB1 - <offline> 09/16/2018 12:40:16 PM

Network: 35

motor down

M0.4 M5.0 M5.4 M5.5 M5.6 Q0.1


S
M5.1 M5.4 M13.4 Q0.0
R
M5.2 M5.5 M13.5

M5.6 M13.6

Network: 36

motor down

M0.3 M5.0 M5.3 M5.4 M5.5 M5.6 Q0.1


S
M5.1 M5.3 M13.3 Q0.0
R
M5.4 M13.4

M5.5 M13.5

M5.6 M13.6

Network: 37

motor down

M0.2 M5.0 M5.2 M5.3 M5.4 M5.5 M5.6 Q0.1


S
M5.2 M13.2 Q0.0
R
M5.3 M13.3

M5.4 M13.4

M5.5 M13.5

M5.6 M13.6

Page 10 of 14
SIMATIC Elevator\SIMATIC 300(1)\CPU 312\...\OB1 - <offline> 09/16/2018 12:40:16 PM

Network: 38

M0.1 M13.7 M13.0


S
M13.1
R
M13.2
R
M13.3
R
M13.4
R
M13.5
R
M13.6
R

Network: 39

M0.2 M13.7 M13.1


S
M13.0
R
M13.2
R
M13.3
R
M13.4
R
M13.5
R
M13.6
R

Network: 40

M0.3 M13.7 M13.2


S
M13.0
R
M13.1
R
M13.3
R
M13.4
R
M13.5
R
M13.6
R

Page 11 of 14
SIMATIC Elevator\SIMATIC 300(1)\CPU 312\...\OB1 - <offline> 09/16/2018 12:40:16 PM

Network: 41

M0.4 M13.7 M13.3


S
M13.0
R
M13.1
R
M13.2
R
M13.4
R
M13.5
R
M13.6
R

Network: 42

M0.5 M13.7 M13.4


S
M13.0
R
M13.1
R
M13.2
R
M13.3
R
M13.5
R
M13.6
R

Network: 43

M0.6 M13.7 M13.5


S
M13.0
R
M13.1
R
M13.2
R
M13.3
R
M13.4
R
M13.6
R

Page 12 of 14
SIMATIC Elevator\SIMATIC 300(1)\CPU 312\...\OB1 - <offline> 09/16/2018 12:40:16 PM

Network: 44

M0.7 M13.7 M13.6


S
M13.0
R
M13.1
R
M13.2
R
M13.3
R
M13.4
R
M13.5
R

Network: 45

M0.1 M5.0 M13.7


S
M0.2 M5.1

M0.3 M5.2

M0.4 M5.3

M0.5 M5.4

M0.6 M5.5

M0.7 M5.6

Network: 46

M13.7 Q0.0
R
Q0.1
R
Q0.7
S

Page 13 of 14
SIMATIC Elevator\SIMATIC 300(1)\CPU 312\...\OB1 - <offline> 09/16/2018 12:40:16 PM

Network: 47

T2
M13.7 S_ODT Q0.7
S Q R

S5T#5S TV BI

R BCD

Network: 48

T3
M13.7 S_ODT M13.7
S Q R

S5T#10S TV BI

R BCD

Network: 49

Network: 50

Page 14 of 14

You might also like