You are on page 1of 18
ALLIANCE SUGAR MILLS (PVT) LIMITED. natin HEAVY MECHANICAL COMPLEX. vo Texte Ain: Muhammad tyes (Manager Marketing) Subj: FIRM ORDER FOR THE SUPPLY OF SUGAR MILLS MACHINERY & FOLIPMENT © "ese refero your Quon # SAM 11S 21381114053 dated 63.01.2014, ne ae pled wo (CF piascurtirm ener fr he sep of loving tem the rts nemoned sans eck Description 10 TongHow Stem Baier 297 Bar (with al” acon. ‘enc Speifeion and scope of mpy ae Aen A | : { “ou Anat Enns ORT i Dele Ex Wonks HMC Tarmsand Confiton 4.15% (Rs.2497500 Advance longi ism reve chee. ._a08¢pmyment vie rs Cheues fl Be mab on ee td presen of pot docunent and on progersve tec peseusio’ of inores 6) HM of ‘memednt tne nied fr manic © ©. 30% via cross cheques at the time of delivery of equipnent. 4 Tohepnment be made cn 1° Dee 201 (Cos ewe infor of HMC woke provide mab) Bune 15% payment wil be made on Feb 1 2018 (Cos chee ia vor of HIM tobe provide insane). . wo Delver-Time aickedldoe acy L« |Last item to be delivered up to. Ave 26h You are requested 0 kinly confirm your detailed detivery schedule in writing within «pri of {wo weeks fom the dt ofthis order ‘500-4, Tul Rd, Lore Cant-Paitan, Ta 2-42 048005152 Fax: 142429000088 Ea ntganseins om (OPERATION: Raahondnbe,Uoauo, Ott hob Resale fALalcbNNGE SUGAR MILLS (PVT) LIMITED evaly @ 2% pet wee of tie vale of th undlivee ts wll imposed and ducted fom the invoice ofthe HMC, However, the maximum pealy wil be Sto theundelwered sons Inspetion lnspection of equipment shall ecard out by our autborzed rep at HMC wark before delivery, ‘All expenses in tis connection sl be bome bys Supervision Services HMC wll ove the sipervson services for erection and instaltion of machinery items provided spied yi, Dawe /Taxes adertaking hal provide a undertaking in wring hat the Boiler ving supplied wl produce seam a8 Per dsian specifi of amex tached SGencral Un case HMC fl to deliver th Scope Equipment or part ofits pe is cbligton, Aline Sop Mils Limited wil beat iter to procure sepe equipment shee Shing ses HMC, fom anywhere on HMC's ik and cos © Be pertinent Pe ur onc iy cepted ase oe Wa) Thanking you, - te ae ee ——s -Tsriciwa ‘ei Chief Executive Officer for Heavy Meshaulesl Complex SA Tent ater Ca Us Fx 2.2 St gun con ‘OPERATIONS: Ratondiod bao Dat ag ANNEXURE - A TECHNICAL SPECIFICATION FOR 01 X 80 TON/ HR BOILER FOR ALLIANCE SUGAR MILLS \ HEAVY MECHANICAL COMPLEX LIMITED TAXILA ~~ BOILER SPECIFICATION | 1 BIDRUM, SUPPORTED TYPE, WATER TUBE.NATURAL CIRCULATION, i BAGASSE FIRED BOILER (@ DESIGN SPECIFICATIONS | Seam evaporation capociyat MCR Tons/Ii 80 ‘Steam pressure at SH outlet Kgfen. co Design presse Kelen! 29 ‘Steam temperature at SH! oulet. % 360410 ‘Feed water temperature *e 105. Air temperature(Air heater inlet) “C. 30. (approx) ‘Flue gas temperature(At stack) °c. 200 (approx) Dram Balanced df sytem Priary fet Bags with 32% mosure ‘Secondary el Teavy frnace ol (FO) lect source Power 50, 415 Vols, 3 phase hament 50 220 ols, Sig, phase Boiler ficiency Basase Oil Bm 85% © ~— wamswzes Heating Surface (approximate) : Bote bank 7860. ‘Furnace 520 me. | | Siper heater 220 | Airheater 2100. Economizer wos » a Ewrnace € Furnace volume 410 we Grate area Ye © Combustion Equipment Fuel Firing rate Pagan {for 1006 MCR HEF Oil Burners) {for 10096 MCR |

You might also like