You are on page 1of 4

5 Years is the Golden Warranty of EGETRONIC Against any Manufacturing Defects

1. DESCRIPTION AND FUNCTION


EGETROINC’s Earth Fault Indicator type FDP 020 -220 is specially designed to be used with
the SCADA system
 The FDP Indicators are equipped with built in test
circuit using a face – mounted box.
 Test button allow self-testing the indicator operation
without need external current injection
 Front mounted Led indicates wrong connection of the
equipment.
 No need for a special treatment in handling,
transportation, installation, or storage of the FDP
indicator,it is a special rugged design.

2. CONTENTS
EGETROINC’s Earth Fault Indicator FD0 consists of:
 Indicator Box with a Fluorescent coated red flag.
 Epoxy molded detachable current transducer.
.

3. OPERATION MECHANISM
 The Flag Changes to Red Color (Set Condition)
in case of the earth fault current increases the
rated pre- set value (e.g.25 amp ) and auxiliary
supply switched off
 The indicator flag turns to the black site
(Automatically reset) by the healthy return of the
auxiliary supply
 As an option the indicator may be equipped with
a relay with 2 normally open contacts. The relay
energies in case the earth current increases the
rated pre-set value and de-energized when the
current dropped or if the auxiliary supply switched off.

El Asher for electronic industries, 409-412 Green land Complex - 10th of Ramadan city – Egypt
002 055 4 410 943 - 002 055 4 410 943 - 002 010 18 48 80 6
WWW.Egertronic.com
5 Years is the Golden Warranty of EGETRONIC Against any Manufacturing Defects
4. TECHNICAL SPECIFICATION
[ANY CUSTOM SPECIFICATIONS ARE BE AVAILABLE UPON REQUIST ]
Subject Value
 Trip Current 10 , 20 , 25 , 50 , 100 A (other values upon request)
(Phase to Ground ) (Tested by Accredited laboratory).
 Indication unit Dimension Suitable for panel installation ( built in 92x92x50 mm)
Indication Mechanism One Electro-Magnet Flag.
Reset of the Indicator Self setting at 220±20 % V AC
 Reset time Less than 30 sec (Tested by Accredited laboratory).
Better than ±10 % ( Optional to customers request )
Accuracy
(Tested by Accredited laboratory).
Response time < 100 msec ( 0.1 sec ) (Tested by Accredited laboratory).
 Allowed Earth fault (surge
20 KA r.m.s for 1.0 sec (Tested by Accredited laboratory).
current)
On Site Function Test One Bush Button one for set only.
 Dimensions Indication Unit 94 mm * 94 mm* 54 mm (W *H*D)
Indication Unit – IP65 (According to IEC 60529:2019)
 Protection Class Sensors – IP 67 (According to IEC 60529:2019)
(Tested by Accredited laboratory).
Verification and test Standard IEEE 495-2007
Operation Temperature Range - 25 ˚C to +70 ˚C
Cable Sheath temp up to 85 °C
Power Supply 220 /110 VAC ± 20 % 50/60Hz
 Two contact relay normally open
 Contact
 Contact 10 A
 One Earth-fault Sensor type TD-**-**for Three core cable
Earth-fault Sensor (CT)
diameter
 Transformer cable length up to 10 meter using an ordinary 2*1cable
Cable Diameter up to 240 mm.
 Parameter can be designed according to the customer request

Note 1 : The above mentioned specifications according to international standards and the
Egyptian electricity distribution companies , and our company has the ability to
design and manufacture any custom models .
Note 1 : All Verification and testing are conducted according International Standards by
EGETRONIC accredited laboratories which accredited from EGAC and
recognized by ILAC according to the ISO 17025 International Standards .

El Asher for electronic industries, 409-412 Green land Complex - 10th of Ramadan city – Egypt
002 055 4 410 943 - 002 055 4 410 943 - 002 010 18 48 80 6
WWW.Egertronic.com
5 Years is the Golden Warranty of EGETRONIC Against any Manufacturing Defects
5. CONNECTION DIAGRAM:

Terminal Connections
1, 2 External AC Supply 220/110 VAC ± 20% 50 / 60HZ
3 ,4 Earth-Fault Sensor Connection (0 – 25 )
5,6 SCADA system relay contact N.O. 1
7, 8 SCADA system relay contact N.O. 2

Sensor
Cable Diameter
Diameter (d)
D1 80-100mm(Round)
D2 100-120mm(Round)
D3 120-140mm(Round)
D4 Option up to 240 mmm

El Asher for electronic industries, 409-412 Green land Complex - 10th of Ramadan city – Egypt
002 055 4 410 943 - 002 055 4 410 943 - 002 010 18 48 80 6
WWW.Egertronic.com
5 Years is the Golden Warranty of EGETRONIC Against any Manufacturing Defects
INSTALLATION
5.1 Earth Fault Sensor Installation
 Install the current transformer around the cables by using the plastic belt
 Pass the shield through the current transformer ring
 Connect the shield to the ground.
5.2 Connection Sensor Transformer
 20 + 0 : 20A
 25 + 0: 25A

6. SHAPE AND DIMENSIONS

7. CODING SYSTEM

FDP XXX YY External Supply

Series Designation Response Auxiliary options Auxiliary options


Current in Amp.  T : For Self test option  220 : For 220 V AC Supply
 R : For Relay Option  110 : For For 110 V AC Supply

FDP 020 TR 220 VAC


This mean that the requested Indicator from FDP Family which activated at 20 A AC for with
additional self test switch and relay used for SCADA system and operation power supply 220V AC

El Asher for electronic industries, 409-412 Green land Complex - 10th of Ramadan city – Egypt
002 055 4 410 943 - 002 055 4 410 943 - 002 010 18 48 80 6
WWW.Egertronic.com

You might also like