You are on page 1of 7
Medmont Studio 7 Release Notes Release date Type Release Version 30/10/2020 Minor 7.20 29/04/2020 Patch TA2 08/04/2020 Patch TAA 12/02/2020 Minor 71.0 10/09/2019 Patch 70.1 28/08/2019 Major 7.0.0 What's New in Studio 7: Summary of Key Features. Studio New Look! Updated graphics and icons throughout Medmont Studio 7. Medmont Studio now in 64-bit, which brings support for larger videos and colour topography Various server & database management improvements Metadata is now stored across all major exam types including £300, medmont meridia and M700 exams. This can be viewed on the exam details tab. Improved architecture for filtering by exam - performance improvement for searching large databases. Language specific architecture and downloads. Reduces download requirements and program file size. Support for import/export of multiple .mxt files, medmont meridia Added support for medmont meridia™ Advanced Topographer (Professional and Classic) New medmont meridia image capture dialog improvements on DV2000 capture window. Includes display of most recent captures and live digital zoom focusing aid (adjustable from 2-10x magnification). New Dry Eye reporting module has been added to Medmont Studio to allow the collection of exam information into a report format for records storage and distribution to patients. A new pupil annotation has been added to the list of available annotations for digital image captures, Improvements to pupil detection in topography and tear film module. ‘Anew Tear Meniscus Height (TMH) ruler attribute has been added for digital image captures allowing the user to measure the tear meniscus height at multiple points and present an average of the collected data medmont meridia and £300 * New Power Diff color scales for Ortho-K * Tear Film exams can now be used with Linked Applications * Pupil annotation is now drawn with a circle tool making it much faster to initially define a pupil region. © Anew default exam category has been added for exams titled "Post Ortho-k" © Calibration window is now resizable. DV2000 (Including medmont meridia) © Medmont Studio now supports capture and exporting of video exams in a compressed format. Currently the supported compression codec is h264 and the level of compression is configurable on a per video source basis. © The grading of images against a selection of included grading scales (including Meiboscale, Efron and BHVI) is now available for all images captured with both medmont. meridia and other supported digital still image sources. * Keeler image source now has camera settings * Allow camera settings dialog to float and switch to semi-transparent when unfocused, to provide easier camera settings adjustment with live view visible See Version specific release notes below for detailed descriptions of features, improvements & bug fixes. 7.2.0 New features Studio * Selecting to filter by exam now presents a blank list with a search dialog ready to set the criteria for the exams you wish to display. This greatly speeds up loading times when searching for exams in large databases. medmont meridia © New Dry Eye reporting module has been added to Medmont Studio to allow the collection of exam information into a report format for records storage and distribution to patients. * Anew pupil annotation has been added to the list of available annotations for digital image captures. * Anew Tear Meniscus Height (TMH) ruler attribute has been added for digital image captures allowing the user to measure the tear meniscus height at multiple points and present an average of the collected data. * You can now return to the factory default capture settings for all medmont meridia based image sources. This includes both camera and illumination settings. medmont meridia and £300 * Anew default exam category has been added for exams titled "Post Ortho-K" DVv2000 + Medmont Studio now supports capture and exporting of video exams in a compressed format. Currently the supported compression codec is h264 and the level of compression is configurable on a per video source basis. * The grading of images against a selection of included grading scales (including Meiboscale, Efron and BHVI) is now available for all images captured with both medmont meridia and other supported digital still image sources. Improvements Studio © The user interface update for all icons has been completed * New icon added to return to start page from any page Installation will now detect if a previous version of Medmont Studio is present but hasn't been updated to a compatible version before attempting to * perform an upgrade. * Upgrades from version 6 to 7 on Win Server 2019 are now working correctly. © Installer repair option will now correctly launch the install configuration tool upon completion. © Default patient birthdate changed to 1/1/1900 to prevent accidental creation of patients born in 1990 medmont meridia © Topography centering algorithm enhanced to improve capture performance in topography and tear film capture modes medmont meridia and E300 * The Tear film capture starting process has been improved so that it will ignore an additional blink if it happens immediately after the initial 2 * blinks that start the exam. The exam start time will be reset to the point of the additional blink, © Random software lockup issue when changing the transparency of a topography map has been corrected © Merida/Keeler slit lamp device clashes have been corrected Dv2000 * Full screen video playback has been fixed for compressed video playback. © Metadata for image captures is now saved at the point of capture ensuring metadata is correct when you change the capture settings during an exam. * Automatic image operations are now working correctly for still mage captures 7.1.2 Known Issues Upgrade Process At present, users wishing to upgrade from a previous version of Medmont Studio to the new 64 bit version of Medmont Studio 7 will need to: 1. Upgrade your Medmont Studio installation to Medmont Studio 6.2.7. This will ensure that all database upgrades and patches have been installed 2. Backup your version 6.2.7 database 3. Uninstall version 6.2.7. ‘When installing Medmont Studio onto a new PC or upgrading an old installation to use a new medmont meridia device, please ensure the device is not connected to the PC before starting the installation process. Improvements medmont meridia & £300 © Fixed silent crash when attempting to work with a topography exam that has no image data associated with it medmont meridia © Fixed an issue where capturing an Anterior, Fluorescein or Meibomian (IR) exam and exporting it may cause video capture settings to be reset or lost. 7.11 Known Issues Upgrade Process At present, users wishing to upgrade from a previous version of Medmont Studio to the new 64 bit version of Medmont Studio 7 will need to: 1. Upgrade your Medmont Studio installation to Medmont Studio 6.2.7. This will ensure that all database upgrades and patches have been installed, 2. Backup your version 6.2.7 database 3. Uninstall version 6.2.7. When installing Medmont Studio onto a new PC or upgrading an old installation to use a new medmont meridia device, please ensure the device is not connected to the PC before starting the installation process. New Features Medmont Studio * Medmont Studio now includes support for the following languages: © Spanish © Italian © German © French © Dutch © Chinese Simplified Note: Language support is for software only. User manuals/instructions are only supplied in English for this release. Improvements Medmont Studio * Fixed exception where Administration tool attempted to call the configuration tool after restoring a database. © Fixed various AccessDB to LocalDB upgrade issues including converting the color scale correctly * Device serial number on registration form is now case insensitive, * Various user interface graphics updates to complete the new look of Medmont Studio 7. medmont meridia Pupil detection on topography exams captured on medmont meridia devices has been improved. Pupil annotation has been changed from black to white to make it clearer on color images * Calibration window is now resizable. * Identification of color scale button has been made clearer. © Fixed assertion error when analysing tear film exams that had poor ring quality on some frames. * Improved handling of possible “Keypad reset” error event that could occur during Anterior, Fluorescein or Meibomian exams, * Auto TBUT reference line is now enabled by default. * Auto TBUT reference line has been changed from yellow/orange to blue. © Combination view now uses a darker color to indicate the currently selected exam. This helps determine which exam view display options will affect. * Pupil annotation has been changed from black to white to make it clearer on color images. * Calibration window is now resizable © Identification of color scale button has been made clearer. © Fixed assertion error when analysing tear film exams that had poor ring quality on some frames. * Auto TBUT reference line is now enabled by default. * Auto TBUT reference line has been changed from yellow/orange to blue. * Combination view now uses a darker color to indicate the currently selected exam, This helps determine which exam view display options will affect. 7.1.0 Known Issues Upgrade Process ‘At present, users wishing to upgrade from a previous version of Mecmont Studio to the new 64 bit version of Medmont Studio 7 will need to’ 1. Upgrade your Medmont Studio installation to Medmont Studio 6.2.7. This will ensure that all database upgrades and patches have been installed, 2. Backup your version 6.2.7 database 3. Uninstall version 6.2.7. New Features Medmont Studio * Metadata is now stored across all major exam types including E300, medmont meridia and M700 exams. This can be viewed on the exam details tab. medmont meridia * The medmont meridia external capture dialog now displays 3 most recently captured images alongside the live preview, reducing the need to switch between the review and live preview display modes. * Anew focus aid has been added to the medmont meridia/DV2000 capture form allowing the user to zoom in on a particular section of the live preview to better adjust the camera position. © Single click enhancement processing for images captured with the Meibomian capture source © Pupil annotation is now drawn with a circle tool making it much faster to initially define a pupil region. Post modification of the pupil annotation can still be made by altering individual points. * Anew tear meniscus height attribute has been adding allowing users to define the tear meniscus height at multiple points * Caution reminder has been added in the software to remind users of the implications of using bright illumination on some types of patients. £300 * Topography review stage now presents the user with an assessment of the ring quality and data points coverage allowing them to make better decisions about which exams to keep and which need to be recaptured. © Pupil annotation is now drawn with a circle tool making it much faster to initially define a pupil region. Post modification of the pupil annotation can still be made by altering individual points. Dv2000 * The medmont meridia external capture dialog now displays 3 most recently captured images alongside the live preview, reducing the need to switch between the review and live preview display modes. Improvements F300 * Leutron support has been removed from Medmont Studio due to a lack of vendor support, Dv2000 * Leutron support has been removed from Medmont Studio due to a lack of vendor support. 7.0.1 Improvements medmont meridia * Fixed an acceptance criterion for medmont meridia serial numbers 7.0.0 New Features Medmont Studio © Medmont Studio now has a 64-bit version, which brings support for larger videos and colour topography * During client installation a list of all compatible Medmont Studio servers on the network is now presented + Medmont Studio will now only download the necessary components and languages to a machine, saving bandwidth * Allow users to anonymously export hash-coded patient names and DOB © Users can now import multiple .mxf/.mcf files at once * An export will now provide an option to split the data into separate files for each patient medmont meridia & Meridia * Added support for medmont meridia™ Advanced Topographer (Professional and Classic) * Centralised Contact Lens licensing mechanism allows client to access interested contact, lens(es) only © The units for attributes in the Analysis Dialog can be toggled between diopters and millimeters where relevant * Tear Film exams can now be used with Linked Applications + New Power Diff color scales for Ortho-K bv2000 * Keeler image source now has camera settings: gamma, master gain, RGB gains, black level * Allow camera settings dialog to float and switch to semi-transparent when unfocused, to provide easier camera settings adjustment with live view visible Improvements Medmont Studio © Drawing of circle annotations has been improved Dv2000 * Deprecated DV2000 image sources: Twain, Flashbus and WIACapture

You might also like