You are on page 1of 1

Andúril 2

4C
2C/2H Actions
Version Check
V 15C 1C
Ceiling Level
1C: Click
Sofirn SP36 (Pro) & Q8 (Pro) Factory Reset 13H
1H: Hold
revision 2021/08/02 5C 2C: Click, Click

Release + Hold again within 1.5s


2C 2H: Click, Hold

to reverse ramping direction


Toggle 3C: Click, Click, Click

Hold: Up / Down
Smooth / Stepped Ramp

Ramp
3C ON 1C Factory Defaults
OFF 1C 4C
Momentary
Default Ceiling Simple UI: 150/150
Lockout Default Ceiling Advanced UI: 120/150

2H Momentary
1H Moonlight

1H 2H Momentary
10H Floor Level
4H Low
Configure Simple UI 1C

Simple UI
Ramp Config Menu for current ramp mode
or for Simple UI via 10H from OFF in Advanced UI
Manual Memory Configuration Menu 3C
1. Release 10H after first flash
10H
1C
Batt Check
1. Release 7H (or 10H in Simple UI) after first flash ► Disable manual memory
► Set Floor Level Click any value to disable manual memory
Click n times for level n of 150
2. Release 10H after second flash
2. Release 7H (or 10H in Simple UI) after second flash ► Configure manual memory timer

Advanced UI
► Set Ceiling Level Click n times for n minutes (0 clicks = timer off)
Click n times for the nth highest level of 150

3. Release 7H (or 10H in Simple UI) after third flash


Automatic: last-ramped brightness
Manual: user‘s saved brightness
10C 4C
► Set number of steps* Hybrid: remember last-ramped brightness
Click n times for the number of steps for n minutes

* n/a in Advanced UI Smooth Ramp configuration 2H


Turbo Level
1C
Activate Manual Memory Turns off the light automatically.
Toggle & save current brightness Keep holding to add 5min 2C Ceiling Level
Smooth / Stepped Ramp increments of runtime 5C
7H to the sunset timer. 1C
10H
1 blink = 5 minutes 2C Auto-Lock

Release + Hold again within 1.5s


5H n clicks = n minutes

to reverse ramping direction


10C Sunset Mode 10H until locked automatically

Hold: Up / Down
3C

Ramp
Momentary Turbo
ON 1C OFF 1C 4C
Momentary
7C Brightness of AUX/Button LEDs in Lockout
Off - Low - High - Blinking
Lockout
3H
5C Momentary 5C 2H Momentary
Mode
1H
2C Moonlight

1H 2H Momentary
Lightning
Candle mode 3H Floor Level
4H Low
Storm memory 1C
Mode 1C
Temperature
2C Thermal Configuration

Set Candle Runtime 3C Check

1 blink = 5 min runtime 5H Brightness of 7C 1C


Batt Check 2C 7H 1. Release 7H after first flash
► Set Current Temperature
Tactical
Button LEDs in Standby Click n times for n °C
Strobe
Actions: Off - Low - High - Blinking
2. Release 7H after second flash
1H: brighter/faster (except Lightning Storm)
2C 2C ► Set Stepdown Temperature Limit
2H: dimmer/slower (except Lightning Storm) Click n times for n + 30°C
5C: go to Momentary Mode / Strobe
2C
V 15C Voltage
Version Check Calibration 7H SOS
Beacon
Mode
Mode
2C Hold
Set Beacon Frequency:
1 blink = 1 second pause
Party Bike
Strobe 2C Flasher
2C
Factory Reset 13H Blinky & Utility Modes
Strobe Modes

You might also like