You are on page 1of 1

Madhya Pradesh Rural Road Devlepment Authority

PIU- INDORE

GRANULAR SUBBASE MIX DESIGN TEST RESULT SUMMERY


1.NAME OF ROAD - Chittoda to Ataheda

2. MATERIAL- GRANULAR SUBBASE GRADE -1

3.DATE OF TEST 21-01-2020

Stone Cement by wt. of Cement by wt. ofA


53 mm 20 mm 10 mm
Dust Mix ggregate
Material Proportions
40% 35% 10% 15% NA NA

4. Sieve Analysis :

IS Sieve Size in mm 75.00 53.00 26.50 4.75 0.075

Average % of Passing 100.0 NA 65.06 19.53 1.50 Remark - G.S.B.GRADE-1

Specification Limits 100 NA 55-75 10..30 0-10

5. Physical Properties :

Test Achieved Specified


i) Modified Proctor
Maximum dry density (MDD) 2.11gm/cc,2.12 gm/cc -
Optimum Moisture content (OMC) 8.46%,8.4 % -
ii) Liquied Limit N.A. Max 25%
iii) Plastic Index Non Plastic Max. 6 %
iv) Combine FI+EI 28.44 <35%
v) Water absorption
53 mm 1.38% Max. 2 %
20 mm 1.15% Max. 2 %
10 mm 1.20% Max. 2 %
vi) AIV 15.86% Max 30%
Remarks :

Checked By Tested By

You might also like