Standard Feature:
• KOHLER Co., provides one-source responsibility for the
generating system and accessories
Rating Range
• The generator set and it’s components are prototype-
KD110W
50Hz tested, factory-built and production-tested
Generator Rating
Standby Prime
Alternator V Phs Hz kW/kVA Amps kW/kVA Amps
RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever
Specification
Engine Engine Electrical
Engine Specification Engine Electrical
Manufacturer John Deere Battery Charging
Engine Model 4045HF120 Ground/Negative Negative
Engine Type Turbocharged Voltage (DC) 12
Cylinder arrangement 4 in-line Starter motor rated voltage (DC) 12
3
Displacement, L (𝑖𝑖𝑖𝑖 ) 4.5 (273) Battery, recommended Ampere
Bore and Stoke, mm (in) 106 x 127 (4.17 x 5.0) Hour (CCA)
Compression ratio 17:1 QTY, CCA 1,680
Piston speed, m/min (ft/min) 381 (1248) Battery Voltage (DC) 12
Rated speed (r/min) 1500
Max, power at rated rpm, kW (BHP) 100 (134) Fuel
Governor Type Mechanical Fuel System
Frequency Regulation ±2.5% Max. Fuel Flow, Lph (gph) 108 (28.5)
Air Cleaner Type Dry Fuel prime pump Manual
Exhaust Fuel Type Diesel
Exhaust System Fuel Tank Capacity, L 190
Exhaust manifold type Dry
3 Lubrication
Exhaust Flow, 𝑚𝑚 /𝑚𝑚𝑚𝑚𝑚𝑚 (cfm) 17.0 (600)
Exhaust Temperature, ℃ (℉) 545 (1013) Lubrication System
Max allowable back pressure, kPa (in 7.5 (2.2) Type Full Pressure
Hg) Oil pan capacity with filter, L (qt) 12.5 (13.2)
Hook up, mm (in) 76.5 (3.0) Oil pan capacity initial filling, L (qt) 13.5 (14.4)
RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever
RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever
Option
Canopy Others
• Canopy M129, 50Hz, 78 dB(A)@1m • ________________________________
Standard
• Critical muffler, 40dB(A) • ________________________________
• Hospital muffler, 29dB(A) • ________________________________
• Connector, 40cm (16in)
• Bellow
• ________________________________
• Protection Guard • ________________________________
• ________________________________
Cooling system
• Block heater (recommend to use when below 0℃ (32℉)
• Radiator protection cover Dimension and weight
Decision-Marker 4000 Controller Open Model
• Alternator protection
• Audible alarm module
• 5 expandable modules with 4 inputs/6 outputs
• Network modules (RTC and GSM modems and Ethernet
router)
• NFPA 100 module
• Remote annunciator Dimension, LxWxH mm: 1950 x 1084 x 1470
• Voltage/speed adjustment module Dry weight, kg: 1214
• Win Telys Software Wet weight,kg: 1414
Fuel system Canopy Model
• Automatic fuel tank fil kit
• Fuel tank with secondary containment basin
• Subbase fuel tank leak alarm
• Water separator fuel filter
Electrical System
• Battery charger, equalize/float type
• Battery isolator switch Dimension, LxWxH mm: 2554 x 1170 x 1680
Engine and alternator Dry weight, kg: 1614
• Alternator strip heater Wet weight,kg: 1814
• Air cleaner, heavy duty (with air restriction indicator)
• Droop kit with 3-function voltage regulator
• Electronic governor
• Lube oil drain pump
• PMG alternator and voltage regulator
• Tropical heavy-duty alternator insulation
RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever