Model:KD110W

380 – 415V Diesel

Standard Feature:
• KOHLER Co., provides one-source responsibility for the
generating system and accessories
Rating Range
• The generator set and it’s components are prototype-
KD110W
50Hz tested, factory-built and production-tested

Standby kW 86 • One-year standard warranty covers all systems and


kVA 107 components
Prime kW 78 • John Deere engine
kVA 97 • KOHLER alternator
• 50℃ radiator
• Frame and vibration damper
• 190L Fuel tank
• Dry air cleaner
• APM303 controller
• Battery and battery cable
• 9dB(A) muffler
• Operation manual

Generator Rating
Standby Prime
Alternator V Phs Hz kW/kVA Amps kW/kVA Amps

220/380 3 50 86/107 163 78/97 148


4R9X 230/400 3 50 86/107 155 78/97 141
240/415 3 50 86/107 150 78/97 136

RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever

GCD5-04006 (KD110W) 0919D EN


Alternator Specification
• IEC60034, NEMA MG1.22, ISO8528, CSA, UL,
ISO9001,ISO14001, CE standard Specification Alternator

• IP23 Manufacturer KOHLER


• Class H Insulation Type 4 Pole Rotating
• 2/3 winding pitch Excitation PMG
Specification 50Hz Leads 12 Leads
Voltage 400V Voltage regulator Solid State
Standby (27℃),kVA 106 Insulation: NEMA MG1
Prime (40℃), kVA 100 Material Class H
Efficiency (full load) 87.6% Coupling Single Bearing
3
Air Flow, 𝑓𝑓𝑓𝑓 /𝑚𝑚𝑚𝑚𝑚𝑚 716 Voltage regulation ±1%

Specification
Engine Engine Electrical
Engine Specification Engine Electrical
Manufacturer John Deere Battery Charging
Engine Model 4045HF120 Ground/Negative Negative
Engine Type Turbocharged Voltage (DC) 12
Cylinder arrangement 4 in-line Starter motor rated voltage (DC) 12
3
Displacement, L (𝑖𝑖𝑖𝑖 ) 4.5 (273) Battery, recommended Ampere
Bore and Stoke, mm (in) 106 x 127 (4.17 x 5.0) Hour (CCA)
Compression ratio 17:1 QTY, CCA 1,680
Piston speed, m/min (ft/min) 381 (1248) Battery Voltage (DC) 12
Rated speed (r/min) 1500
Max, power at rated rpm, kW (BHP) 100 (134) Fuel
Governor Type Mechanical Fuel System
Frequency Regulation ±2.5% Max. Fuel Flow, Lph (gph) 108 (28.5)
Air Cleaner Type Dry Fuel prime pump Manual
Exhaust Fuel Type Diesel
Exhaust System Fuel Tank Capacity, L 190
Exhaust manifold type Dry
3 Lubrication
Exhaust Flow, 𝑚𝑚 /𝑚𝑚𝑚𝑚𝑚𝑚 (cfm) 17.0 (600)
Exhaust Temperature, ℃ (℉) 545 (1013) Lubrication System
Max allowable back pressure, kPa (in 7.5 (2.2) Type Full Pressure
Hg) Oil pan capacity with filter, L (qt) 12.5 (13.2)
Hook up, mm (in) 76.5 (3.0) Oil pan capacity initial filling, L (qt) 13.5 (14.4)

RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever

GCD5-04006 (KD110W) 0919D EN


Specification Controller
Cooling
Radiator System
Radiator system capacity , L (gal) 20.2 (5.3)
Heat rejected to cooling water at rated, kW
36 (2047)
(Btu/min)
Water pump type Centrifugal
APM303
Fan loss, kW (HP) 2.5 (3.4) The APM303 is a versatile unit which can be
Max,restriction of cooling air, intake and operated in manual or automatic mode. It offers
0.2 (0.8)
discharge of radiator, kPA (in 𝐻𝐻2 𝑂𝑂) the following features:
Measurements:
Phase-to-neutral and phase to phase voltages, fuel
Air requirement
level, load currents, active power, power factors, kW/h
Radiator-cooled cooling air 𝑚𝑚3 /𝑚𝑚𝑚𝑚𝑚𝑚 (scfm) 222 (7841) energy meter, oil pressure and coolant temperature
Combustion air, 𝑚𝑚3 /𝑚𝑚𝑚𝑚𝑚𝑚 (𝑓𝑓𝑓𝑓 3 /𝑚𝑚𝑚𝑚𝑚𝑚) 6.4 (225) Supervision:
3 3 Modbus RTU communication on RS485
Air density =1.20 𝑘𝑘𝑘𝑘/𝑚𝑚 (0.075 𝑙𝑙𝑙𝑙/𝑓𝑓𝑓𝑓 )
Reports:
2 configurable reports
Fuel Consumption Safety features:
Overspeed, oil pressure, coolant temperatures,
Diesel, L/h (gal/h), load% Standby
minimum and maximum voltage, minimum and
100% 25.5 (6.7) maximum frequency
Diesel, L/h (gal/h), load% Prime Traceability
100% Stack of 12 stored events
23.5 (6.2)
For further information, please refer to the datasheet
75% 16.5 (4.4) for APM303
50% 11.5 (3.0)

RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever

GCD5-04006 (KD110W) 0919D EN


KOHLER CO., KOHLER Power Systems
Kohler, Wisconsin 53044 USA 400 1808 900
Phone +1 (920)-565-3381 Power@kohler.com
Kohler Power.com

Option
Canopy Others
• Canopy M129, 50Hz, 78 dB(A)@1m • ________________________________
Standard
• Critical muffler, 40dB(A) • ________________________________
• Hospital muffler, 29dB(A) • ________________________________
• Connector, 40cm (16in)
• Bellow
• ________________________________
• Protection Guard • ________________________________
• ________________________________
Cooling system
• Block heater (recommend to use when below 0℃ (32℉)
• Radiator protection cover Dimension and weight
Decision-Marker 4000 Controller Open Model
• Alternator protection
• Audible alarm module
• 5 expandable modules with 4 inputs/6 outputs
• Network modules (RTC and GSM modems and Ethernet
router)
• NFPA 100 module
• Remote annunciator Dimension, LxWxH mm: 1950 x 1084 x 1470
• Voltage/speed adjustment module Dry weight, kg: 1214
• Win Telys Software Wet weight,kg: 1414
Fuel system Canopy Model
• Automatic fuel tank fil kit
• Fuel tank with secondary containment basin
• Subbase fuel tank leak alarm
• Water separator fuel filter
Electrical System
• Battery charger, equalize/float type
• Battery isolator switch Dimension, LxWxH mm: 2554 x 1170 x 1680
Engine and alternator Dry weight, kg: 1614
• Alternator strip heater Wet weight,kg: 1814
• Air cleaner, heavy duty (with air restriction indicator)
• Droop kit with 3-function voltage regulator
• Electronic governor
• Lube oil drain pump
• PMG alternator and voltage regulator
• Tropical heavy-duty alternator insulation

RATINGS: All three-phase units are rated at 0.8 power factor. PRP: Prime power is available for an unlimited number of annual operating hours in variable load applications in
accordance with ISO8528.1. A 10% overload capability is available for a period of 1 hours within a 12-hour period of operating in accordance with ISO3046.1. ESP: The emergency
standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO-8528.1. Overload is not allowed
The generator set manufacturer reserves the rights to change the design or specification without notice and without any obligation or liability whatsoever

GCD5-04006 (KD110W) 0919D EN