Professional Documents
Culture Documents
ØD
ØC
Airflow
to allow installations in most standard sizes
of commercial ducts.
• The motor and impeller assembly are
suitable for operation at any angle and
deliver exceptional airflow performances B B
against the high static pressures typically
A
found in ducted ventilation systems.
• All TSK II series fan casing are
manufactured from corrosion resistant
pressed galvanised sheet steel.
• Non-stalling backward curved impeller Wt
Model A B ØC ØD
(kg)
which is factory matched to the
corresponding external rotor motor and TSK II 100L 194 23 243 98 3
dynamically balanced to ISO 1940 standards TSK II 125L 195 27 243 123 3
for vibration free operation. TSK II 160L 222 28 333 157 5
• All models are supplied as standard with a TSK II 200L 223 25 333 198 5
remotely mounted wiring junction box to
TSK II 250L 206 27 333 248 6
provide the installer with a completely
flexible choice for positioning and TSK II 315L 230 25 401 312 8
installation.
• Motors of this TSK II series are fully speed
controllable using electronic or auto-
transformer voltage control regulators.
• Enclosed, single phase, 230V, 50/60 Hz
Kruger Ventilation Industries Asia Co.,Ltd certies that
external rotor type, motors included sealed the TSK II series shown herein is licensed to bear the
for life ball bearing assemblies and Class B, AMCA Seal. The ratings shown are based on tests and
procedures performed in accordance with AMCA
IP44 protection with an internal automatic publication 211 and AMCA publication 311 and comply
reset safety thermal overload protection with the requirements of the AMCA Certied Ratings
Program.
device as standard.
• Operating temperature - 40° C to +40 ° C
Technical Data
Max Input
Max Q Motor N° Max Insulation dB (A)
Model Power Phase Hz RPM
m3/h Protection Pole Amp Class at 3m
W
TSK II 100L 265/267 73/91 IP44 1 2 50/60 0.33/0.35 B 52/53 2500/2650
800
700
Lw(A) [dB(A)]
600
84
500
Ps (Pa)
80
400 79 81
79 78
300 76
80 80
200 75 75 77
76
51 80
100 73
73 72
73 80 78 80
72 83
0
0 200 400 600 800 1000 1200 1400 1600 1800
Q (m³/h)
1100
1000
Lw(A) [dB(A)]
900
800
700
600 80
Ps (Pa)
82
500
81
400
81 79 79
77
300
81 82
200 74 75 77 79
73 80
100
72
74 72 81 80 82 84
0
0 200 400 600 800 1000 1200 1400 1600 1800
Q (m ³/h)
Reducers
- Plastic sections for the connection of two ducts of
different duct diameters.
The company is always improving and developing its products, therefore the company reserves the right of making changes to the illustrated products.
Certified dimension can be provided upon request.
• Cabinet is manufactured in
galvanized sheet steel. Dimension
• Incorporates a direct driven,
DIDW forward curved centrifugal
fan.
• Removable access panel on both
sides for easy access to fan and motor.
• Flanged inlet and outlet for easy
ductwork connection.
• Operating temperature -20°C to +40°C
Optional Features:
• Internal Insulation
Wt
• Filter with throwaway media Model A B C D E F G H J K
(kg)
• Different discharge orientation CCD 140 400 258 250 198 111 210 160 440 25 210 10
CCD 160 440 360 305 204 204 270 230 480 25 265 15
CCD 7-7 440 402 395 263 232 240 344 476 25 342 18
CCD 8-8 500 442 425 291 260 300 384 536 25 372 21
CCD 9-7T 550 380 400 236 266 348 322 586 25 347 23
CCD 9-7 550 440 460 236 266 348 382 586 25 407 26
Kruger * certifies that the CCD series
CCD 9-9T 550 380 400 302 266 348 322 586 25 347 24
shown herein is licensed to bear
the AMCA Seal. The ratings shown CCD 9-9 550 440 460 302 266 348 382 586 25 407 26
are based on tests and procedures
performed in accordance with CCD 10-8 610 520 505 269 293 410 462 646 25 452 32
AMCA publication 211 and comply
with the requirements of the CCD 10-10 610 520 505 335 293 410 462 646 25 452 34
AMCA Certified Ratings Program.
* Kruger Ventilation Industries Asia Co., Ltd CCD 12-9 710 605 570 313 345 510 547 746 25 517 41
* Kruvent Industries (M) Sdn Bhd
CCD 12-12 710 605 570 399 345 510 547 746 25 517 43
Technical Data
CCD 140 70W 4P-1 1SK 547 70 - IP21 1 50 0.6 230 3.5/400 B 50 1400
CCD 160 70W 4P-1 1SK 875 70 - IP21 1 50 0.7 230 3.5/400 B 52 1400
CCD 7-7 150W 4P-1 1SK 1778 150 - IP20 1 50 1.1 230 7.5/450 F 56 1300
CCD 8-8 180W 4P-1 1SK 1668 180 - IP20 1 50 1.2 230 7.5/450 F 57 1300
CCD 9-7T 245W 4P-1 3SY 1966 245 600/530/460 IP21 1 50 2.6/2.3/2.0 230 7.5/450 F 57 1200/1150/1100
CCD 9-7 245W 4P-1 3SY 2138 245 600/530/460 IP21 1 50 2.6/2.3/2.0 230 7.5/450 F 54 1200/1150/1100
CCD 9-9T 350W 4P-1 3SK 2653 350 800/620/460 IP21 1 50 3.5/2.7/2.0 230 12.5/450 F 50 1300/1200/1100
CCD 9-9 350W 4P-1 3SK 2797 350 920/650/480 IP21 1 50 4.0/2.8/2.1 230 12.5/450 F 52 1300/1200/1100
CCD 10-8 550W 4P-1 3SK 3654 550 1380/1080/870 IP21 1 50 6.0/4.7/3.8 230 16.0/450 F 53 1300/1250/1150
CCD 10-10 550W 4P-1 3SK 3830 550 1310/1060/850 IP21 1 50 5.7/4.6/3.7 230 16.0/450 F 55 1300/1250/1150
CCD 12-9 709W 6P-1 3SY 5040 709 1330/870/580 IP21 1 50 5.8/3.8/2.5 230 12.5/450 F 56 900/820/750
CCD 12-12 709W 6P-1 3SY 5389 709 1290/850/530 IP21 1 50 5.6/3.7/2.3 230 12.5/450 F 58 900/820/750
- Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
- dB(A) at 3m measured at free discharge.
- dB(A) levels are not licensed by AMCA International.
Performance Data
160 CCD 140 70W 4P-1 1SK 250 CCD 160 70W 4P-1 1SK
200
120
Static Pressure (Pa)
80
100
40
50
0 0
0 100 200 300 400 500 600 0 200 400 600 800 1000
280 CCD 7-7 150W 4P-1 1SK 400 CCD 8-8 180W 4P-1 1SK
240
300
200
Static Pressure (Pa)
160
200
120
80
100
40
0 0
0 500 1000 1500 2000 0 500 1000 1500 2000
600 CCD 9-7T 245W 4P-1 3SY 500 CCD 9-7 245W 4P-1 3SY
500
400
Static Pressure (Pa)
400
300
300
200
200
100
100
0 0
0 500 1000 1500 2000 0 500 1000 1500 2000 2500
Flow Rate (m³/h) Flow Rate (m³/h)
- Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
- The AMCA Certified Ratings Seal applies to air performance only.
- Performance certified is for installation type D - Ducted inlet, Ducted outlet.
Performance Data
500 CCD 9-9T 350W 4P-1 3SK 600 CCD 9-9 350W 4P-1 3SK
500
400
Static Pressure (Pa)
300
200
200
100
100
0 0
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000
800 CCD 10-8 550W 4P-1 3SK 800 CCD 10-10 550W 4P-1 3SK
600 600
Static Pressure (Pa)
400 400
200 200
0 0
0 1000 2000 3000 4000 0 1000 2000 3000 4000
500 CCD 12-9 709W 6P-1 3SY 500 CCD 12-12 709W 6P-1 3SY
400 400
Static Pressure (Pa)
300 300
200 200
100 100
0 0
0 1000 2000 3000 4000 5000 6000 0 1000 2000 3000 4000 5000 6000
- Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
- The AMCA Certified Ratings Seal applies to air performance only.
- Performance certified is for installation type D - Ducted inlet, Ducted outlet.
The company is always improving and developing its products, therefore the company reserves the right of making changes to the illustrated products.
Certified dimension can be provided upon request.
CSD Series
In-Line Fan – CSD Series
• Cabinet is manufactured in Dimensions
galvanised sheet steel.
• Access door fitted as standard.
• Removable access door for easy G
E
accessibility to motor and fan. C B
• Flanged inlet and outlet for easy
ductwork connection.
• Easy installation.
• Low noise level.
• Ease of maintenance.
D
A
F
• Thermally protected motor.
Technical Data
Max Q Power Motor Max. Ins. dB (A)
Model Phase Hz Voltage uF/V RPM
m³/h W Prot. Amp Cl at 3m
CSD 200 4P-1 1SY 845 165 IP21 1 50 0.9 220-240 7.5/450 F 52 1440
CSD 225 4P-1 1SY 1090 245 IP21 1 50 1.46 220-240 7.5/450 F 54 1380
CSD 250 4P-1 3SY 1870 350 IP21 1 50 3.0/2.3/1.7 220-240 12.5/450 F 54 1300/1150/1050
CSD 280 4P-1 3SY 2590 550 IP21 1 50 5.2/4.3/3.8 220-240 12.5/450 F 57 1300/1250/1150
CSD 315 4P-1 3SY 2940 750 IP21 1 50 6.5/5.5/4.9 220-240 20/450 F 57 1300/1250/1150
CSD 315 6P-1 3SY 3160 709 IP21 1 50 4.6/3.6/2.6 220-240 12.5/450 F 56 950/850/750
CSD 355 6P-3 1SC 4970 1100 IP54 3 50 3.1 400 - F 58 950
CSD 400 6P-3 1SC 6840 1500 IP54 3 50 5.0 400 - F 59 960
- Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
Performance Curve
300 CSD 200 4P-1 1SY 450 CSD 225 4P-1 1SY
400
250
350
200 300
Static Pressure (Pa)
100 60 150
60
100
50
59 50
59
0 0
0 100 200 300 400 500 600 700 800 900 0 200 400 600 800 1000 1200
F l Flow
o w RRate
at e ((m³/h)
m3 / h) F l o wRate
Flow R at(m³/h)
e ( m3 / h)
600 CSD 250 4P-1 3SY 800 CSD 280 4P-1 3SY
700
500
600
Static Pressure (Pa)
(Pa)
400
(Pa)
500
Static Pressure (Pa)
64
Pressure
StaticPressure
63 67
300 400 63
62 65
Static
61 61 63
300 61
200
63
59 61 200 62
100 59 61
57 100
58 59
57
0 0
0 400 800 1200 1600 2000 0 400 800 1200 1600 2000 2400 2800
Flow
Flow
Flow Rate
Rate
Rate (m³/h)
(m³/h)
(m3/h) (m3/h)
Flow Rate (m³/h)
800 CSD 315 4P-1 3SY 450 CSD 315 6P-1 3SY
700 400
350
600
Static Pressure (Pa)
300
Static Pressure (Pa)
500 67
65 250 67
400 64 66 66
64 200
64
300 66
64.5 150 65
64 64
200 63
64 100
63
63 64
100 62 50
63
62
62 63 63.5
0 0
0 400 800 1200 1600 2000 2400 2800 3200 0 500 1000 1500 2000 2500 3000 3500 4000
Flow Rate (m³/h) Flow
Flow Rate
Rate (m3/h)
(m³/h)
- Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
- Sound pressure level Lp(A) at 1m free field.
- The AMCA Certified Ratings Seal applies to air performance only.
Performance Curve
500 CSD 355 6P-3 1SC 600 CSD 400 6P-3 1SC
500
400 68 69
Static Pressure (Pa)
67 400 67.5
300
67
200
66
200
100
65 100 65
0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000 6000 7000 8000
Flow Rate
Flow(m3/h)
Rate (m³/h) FlowRate
Rate(m3/h)
(m³/h)
Flow
- Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories).
- Sound pressure level Lp(A) at 1m free field.
- The AMCA Certified Ratings Seal applies to air performance only.
The company is always improving and developing its products, therefore the company reserves the right of making changes to the illustrated products.
Certified dimension can be provided upon request.