You are on page 1of 12

Siemens ENEAS

solutions for monitoring


System solutions for operation data analysis,
condition monitoring, and power quality assurance

Answers for energy.


An integrated approach
towards the entire spectrum
of energy automation

Always one step ahead with The basis for success


ENEAS solutions from Siemens
Siemens ENEAS solutions for monitoring
Comprehensive and efficient overall provide the basis for all grid management
solutions for all areas of network and planning activities: the logging,
automation based on time-tested processing, and visualization of relevant
Siemens products – this is the idea data from transmission and distribution
behind Siemens ENEAS (Efficient Network networks. Such data allow for the
and Energy Automation Systems). For substantial optimization of capacity
out-of-the-box system solutions as well utilization, availability, and power quality.
as for highly customized turnkey
Power quality is an increasingly important
concepts, ENEAS solutions excel by
issue. Regulation bodies tend to impose
efficiency thanks to low costs an increasing number of power quality
throughout the entire life cycle specifications on network operators, and
new business models are often based on
sustainability through extensive
accurate contractual agreements on
performance reserves and open
power quality. ENEAS solutions for
interfaces
monitoring provide suitable answers:
an ideal technical basis for the fast, precise, and easily accessible fault
intelligent grids of the future analysis and fault location, as well as the
ongoing monitoring of all operational
the high level of safety only a
parameters, enable the continuous
demonstrably dependable business
optimization of all network assets.
partner can guarantee

2
ENEAS
(Efficient Network and Energy Automation Systems)

Solutions for Solutions for Solutions for Solutions for Solutions for
substation distribution monitoring control center life cycle
automation and automation management
protection

Digital substation Medium voltage Disturbance and Network Consulting


automation automation fault record management
Training
systems analysis systems
Feeder automation
Support
Telecontrol Condition Applications
Applications
systems monitoring Maintenance
Telecontrol nodes,
Protection Power quality frontends, Retrofit
systems systems gateways Financing
Infrastructure

Integrated energy automation

ENEAS – grid intelligence as the smart connection to Smart Grid applications

Siemens ENEAS solutions manage all aspects of energy automation with efficient project planning,
reliable safety functions, unlimited communication, and compatibility with international standards.
They create a solid foundation for intelligent transmission and distribution networks.

The key to reliable network operation: just a few of them. This is why asset
recognizing faults before they become monitoring and precise analyses become
failures more and more important. Along with
targeted automation they are considered
The world of today is highly dependent
an essential prerequisite to responsible
on a safe and secure supply with electrical
grid management.
power. Over 60,000 high-voltage and
more than 900,000 medium-voltage Siemens ENEAS solutions for monitoring
substations, along with 550,000 fulfill the technical requirements necessary
transformers, 400,000 circuit breakers, to keep a close eye on an entire grid and
and millions of miles of overhead lines all its elements. The advantages are
and cables are in operation around the convincing: blackouts and power quality
globe to bring electricity to the fluctuations can be effectively prevented,
consumers. precise fault localization and analysis can
be performed within a short time, and
However, most of these assets are still
reports that comply with all relevant
controlled by hand or only partially
regulations are generated automatically.
automated. At the same time, there are
Moreover, Siemens ENEAS solutions for
new challenges to be met by utilities and
monitoring pave the way for condition-
network operators. The rise of distributed
oriented maintenance, which further
generation and the growing share of
helps keep life cycle costs low.
renewable energy sources in the world’s
energy balance, aging equipment, and
dramatically changing load situations are

3
How can I get a grip on
network disturbances?

Disturbance and fault record analysis

The key to securing an advantage in Designed as an integrated network


a highly competitive market quality system and integrating third-
party devices as well as heterogeneous
Network quality is one of the most
generations of technology, Siemens
important competitive factors in today’s
ENEAS solutions for monitoring help
liberalized and increasingly demanding
to get a grip on these problems. The
energy markets. Unstable power quality
network diagnostic system is compatible
and, in the worst case, blackouts result in
with any given infrastructure and provides
considerable contractual penalties.
fast and highly accurate diagnoses of
The best approach towards consistently network events. It automatically provides
preventing such difficulties is accuracy clear, unambiguous facts. It makes
and quick response to power network possible consistent, standardized, and fully
events. Continuous monitoring and automated network monitoring and fault
documentation enable such quick action. analysis. Moreover, it enables network
However, improving system diagnostic operators to seamlessly document fault
capabilities can also result in a data states and the quality of the supplied
avalanche. Modern monitoring, protection, electrical energy based on relevant grid
and recording systems produce data that code standards.
need to be understood, processed, and
A network diagnostic based on the Siemens
analyzed quickly. And often diverse data
ENEAS philosophy system is, therefore,
for power quality and equipment
a long-term investment which helps save
monitoring reports need to be processed.
value, archive acceptance, and enhances
Moreover, network events are often
a good reputation in the market.
complex and time-critical. So qualified
staff are required to resolve the issues.

4
Consistent network monitoring Your benefits
and fault reporting with a single
system Inclusion of all available data sources,
also third-party fault recorders, numerical
protection devices, and power quality
devices, for instance
Coherent grouping of all records relating
to a specific network event
Classification of the grouped events
according to their severity
Accurate distance to fault location and
fault analysis
Fast distribution and availability of the
results through e-mail, text message, and
Web interface
Consistent archiving of all relevant data

Best practice: Energinet.dk, Denmark The reporting is performed through the


company’s intranet, which provides high-
The customized ENEAS solution for
speed data transfer. Within minutes after
Energinet.dk, a network operator in
the first fault reports are generated, the
Denmark, was the implementation of
system produces a report which the
a single central Siemens SIMEAS SAFIR
maintenance staff can use to take
network diagnostic system for the collection
necessary action. This information is
of all records from the 23 substations
available to all required personnel, who
within the company’s network. The main
just need to open the SIMEAS SAFIR Web
aim was to provide a standardized, Web-
pages to analyze the fault online. The
accessible archive of all fault records as
records are stored for at least one year in
well as a standard reporting archive for A sophisticated ENEAS solution based on
a local database, and original as well as a Siemens SIMEAS SAFIR system provides
easy analyses. The system integrates data
enhanced fault records can be viewed on Energinet.dk with a standardized archive of
from fault recorders as well as from
the system’s Web pages. They can be all fault records and standard fault reporting
protection relays.
zoomed, and the data can be analyzed in a single system. Within the customer’s
At a speed of 0.7 megasamples per minute, using a timeline. The records can also Intranet, all data are accessible through an
which equals approximately 25 protection be exported in PDF format or as zipped easy-to-operate Web interface.
records per minute, the system sorts, Comtrade files.
documents, and reports all faults signaled
by the various data sources used to
monitor the transmission network. For
Energinet.dk, the SIMEAS SAFIR system
supports Qualitrol BEN 6000 with BEN 32,
Hathaway IDM with ReplayPlus, and
SICAM DISTO with protection relays.

5
How can I increase the
performance of my assets
in a sustainable manner?

Condition monitoring

Knowledge that translates into advanced over the years, the development
performance and profitability took place for each type of asset on its
own, resulting in a cluttered condition
Expenditure cuts, the loss of expert
monitoring landscape that offers virtually
knowledge due to retirements or staff
no synergy options.
downsizing, and the need for the
operation of aging equipment at higher Siemens has developed Integrated
levels are only some of the challenges Substation Condition Monitoring (ISCM),
utilities and network operators have to a modular platform that is capable of
face today. Yet, they are expected to bundling different types of power
maintain and even increase their levels transmission and distribution monitoring
of performance. systems. Various elements of this
platform are used for the ENEAS solutions
Intelligent grid technologies that help
for monitoring. They make it possible to
establish Smart Grids can provide suitable
use time-tested standard modules in a
answers. Condition monitoring is one of
highly efficient manner and are open to
these technologies, suitable whenever it
customer specific solutions for optimal
comes to optimizing the performance of
integration.
technical equipment. As an important
element of both asset management and ISCM surveys all relevant substation
operation support, it provides network components and includes condition
operators with recommendations based monitoring systems for transformers and
on diagnostics and the analysis of their various components, for partial
measured values. discharge and gas density in gas-
insulated switchgear, for circuit breakers,
While condition monitoring has,
overhead line capacity, cables, and
fortunately, become increasingly more
optionally also for isolators and surge
6
arresters. ISCM can be implemented in monitoring solution. Such a solution
any existing substation. Possible provides complete asset-related condition
configurations comprise everything from information in a common format and
simple asset-embedded value monitors practicable recommendations to the
all the way to a fully integrated condition operator and the asset manager.

Transformer GIS Overhead Line Circuit Breaker Cable Surge Arrester ISCM surveys all
relevant elements of
a grid and can be
implemented in any
given infrastructure.

Tensile
force
Active part SF6 RTU RTU
Ambient SF6
On-load tap Partial temperature
RTU RTU RTU Temperature RTU
changer discharge Ambient
Gas-in-oil Electric temperature Fiberglass
analysis arc sensor

7
The real innovation behind ISCM, Unlike stand-alone condition monitoring
however, is the evaluation of the logged systems for each asset, ISCM is an overall
data with centrally administrated analysis system for all major assets of a
knowledge modules on substation or, substation, making possible the
preferably, control center level. This prediction of the future health state of
paves the way for accurate condition entire networks.
information and enables the operators
Thanks to the common IT platform of all
and asset managers to enhance the
modules, the relevant data is collected,
operating performance of the assets and
analyzed, and presented in a suitable
at the same time reduce costs.
manner through the SCADA system.
Siemens ISCM can be precisely customized Siemens’ user interface provides clear,
and seamlessly integrated into any well-structured displays, the visualization
given substation communication and of values, either numeric or in the form
visualization infrastructure. Rendering of bar graphs, curves, and charts, logging
all condition information in a consistent of reports, convenient query functions
format, the system is a major contribution on reports, and even the visualization of
to the optimal utilization of all resources external information.
within a network.

8
Maximized investment
utilization with targeted Your benefits
solutions
Reduced life cycle cost thanks to
optimized maintenance
Extended component life through
consistent prevention of overstressing
Optimized performance through loading
above “book” rating
Avoidance of downtimes and the need
for emergency maintenance
Possibility for consistent preventive
maintenance
Reduction of material costs and incidental
expenses

Exemplary user display


and knowledge modules

9
How can I make power
anomalies a thing of the past?

Power quality systems

The need for clean power surges, and transients. Many operations
are very sensitive to even very short
Reliability is only one side of the equation
interruptions and anomalies, as these can
in electrical power supply. The other, and
cause outages, production losses, and
the one that is gaining in importance at
high follow-up costs. Examples are
the moment, is quality. Assuring the
continuous process operations, where
quality of delivered power at the point
short interruptions can disrupt the
of use is no easy task. Even worse, there
synchronization of the machinery and
is no way that electricity which does not
result in large volumes of semi-processed
fulfill certain quality criteria can be
product and multistage batch operations,
withdrawn from the supply chain or
where an interruption during one process
rejected by the customer.
can destroy the value of previous
But while more and more everyday operations.
operations have quite critical power
This is why power quality is an issue for
supply requirements, the number of
both network operators and power
factors that can create power quality
producers as well as for customers such
problems is also rising. Today’s
as industrial plants, and power quality is
widespread use of power electronics is
an integral part of many power supply
just one example.
contracts nowadays.
Customers are increasingly aware of
power anomalies such as harmonic
distortion, under and overvoltage, dips,

10
Consistent power quality
management with a Your benefits
comprehensive system
Comprehensive solution for all power
quality and reliability issues
Generation of fully compliant reports
Automatic notifications via email, text
message, fax, and printer in the case of a
fault

All it takes to be on the safe side The levels of power quality solutions
ENEAS solutions for power quality comprise
a range of quality measurement and

Publishing
of results
analysis systems that enable the network SIMEAS SAFIR

operator to manage and control all


Control center

quality and reliability issues within a


network. Tried and proven Siemens
SICAM, SIMEAS, and SENTRON products
Evaluation

are the basis for continuous data collection. SICAM PQS SIMEAS SAFIR
At multiple points within the network, (server/client) (server/client)

data are collected for all relevant


parameters such as voltage, current,
preprocessing
Station level

power, frequency, system load, reactive SICAM PQS


station unit Others
power, power flow direction, harmonics,
Data

flicker, dips and swells, and interruptions.


Reports are generated according to
EN 50160.
Measuring and
monitoring
Field level

In case of a fault, automated notifications


via email, text message, fax, and printer SIPROTEC 3rd party 3rd party SIMEAS R SIMEAS Q80 3rd party

ensure fast reactions. Moreover, automatic


Protection devices Fault recorders Power quality
reporting ensures full compliance with all
contractual and regulatory obligations.

11
Published by and copyright © 2010:
Siemens AG
Energy Sector
Freyeslebenstrasse 1
91058 Erlangen, Germany

Siemens AG
Energy Sector
Power Distribution Division
Energy Automation
Humboldtstrasse 59
90459 Nuremberg, Germany

For more information, please contact


our Customer Support Center.
Phone: +49 180 524 70 00
Fax: +49 180 524 24 71
(Charges depending on provider)
E-mail: support.energy@siemens.com

Order No. E50001-G720-A240-X-4A00


Printed in Germany
Dispo 06200, c4bs No. 7433
fb 3009 481546 WS 09101.5

Printed on elementary chlorine-free


bleached paper.

All rights reserved.


Trademarks mentioned in this document
are the property of Siemens AG, its affiliates,
or their respective owners.

Subject to change without prior notice.


The information in this document contains
general descriptions of the technical options
available, which may not apply in all cases.
The required technical options should therefore
be specified in the contract.

www.siemens.com/energy

You might also like