You are on page 1of 85

1

Best Pneumatics Vol. 14

Air Line Equipment


앬 Modular F.R.L. Unit
F.R.L.
Air Filter + Regulator + Lubricator: AC10 to 60 ······················ P. 14-2-5
Filter Regulator + Lubricator: AC10A to 40A ·························· P. 14-2-16 AV
Air Filter + Regulator: AC10B to 60B ····································· P. 14-2-18 AU
Air Filter + Mist Seperator + Regulator: AC20C to 40C ·········· P. 14-2-20 AF
Filter Regulator + Mist Seperator: AC20D to 40D ·················· P. 14-2-22 AR
Attachment Specifications ······················································· P. 14-2-24
IR
Accessory ················································································ P. 14-2-29
VEX
Made to Order Specifications ·················································· P. 14-2-31
AMR
ITV
IC
VBA
VE
VY1
G
PPA
AL

Soft Start-up Valve: AV2000/3000/4000/5000 ························ P. 14-3-1


Lube Unit: AU ········································································· P. 14-3-11
Large Flow Air Filter: AF800/900 ············································ P. 14-3-13

14-2-1
2

F.R.L. (Filter/Regulator/Lubricator)
Precautions 1
Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety
Instructions and Common Precautions on the products mentioned in this
catalog, and refer to main text for more detailed precautions on every series.

Design Selection
Warning Warning
1. The standard bowl for the air filter, filter regulator, and 1. The mineral grease used on internal sliding parts and seals
lubricator, as well as the sight dome for the lubricator are made may run down to outlet side components. Please consult with
of polycarbonate. Do not use in an environment where they are SMC if this is not desirable.
exposed to or come in contact with organic solvents, chemicals, 2. Regulator and filter regulator
cutting oil, synthetic oil, alkali, and thread lock solutions. 1) Residual pressure release (outlet pressure release) is not
2. Avoid applications where pressurized air is frequently complete by releasing the inlet pressure. To release residual
introduced to and released from the standard bowl of an air pressure, select a model with a back flow mechanism. Using
filter, filter regulator, or lubricator. It may cause the bowl to be a model without a back flow mechanism makes for
damaged. Use of a metal bowl is recommended for such inconsistent residual pressure release (i.e., residual pressure
applications. may or may not be released) depending upon the operating
3. Please consult with SMC if the intended application calls for conditions.
absolutely zero leakage due to special atmospheric 2) Please contact SMC if air will not be consumed in the system
requirements, or if the use of a fluid other than air is required. for a long period of time, or if the outlet side will be used with
a sealed circuit and a balanced circuit, as this may cause the
4. Regulator and filter regulator set pressure of the outlet side to fluctuate.
Be sure to install a safety device to prevent damage or 3) Set the regulating pressure range for the outlet pressure of
malfunction of the outlet side components when the output the regulator in a range that is 85% or less of the inlet
pressure exceeds the set pressure value. pressure. If set to above 85%, the outlet pressure will be
easily affected by fluctuations in the flow rate and inlet
Caution pressure, and become unstable.
1. Select a model that is suitable for the desired purity by referring 4) A safety margin is calculated into the maximum regulating
to the SMC’s Best Pneumatics catalog. pressure range appearing in the catalog's specification table.
However, the outlet pressure may exceed the set pressure
2. Components cannot be used for applications that are outside due to a delay in the valve’s closing.
the range of specifications. Please consult with SMC when you 5) Please contact SMC when a circuit requires the use of a
anticipate using the component outside the range of its regulator having relief sensitivity with high precision and
specifications (such as temperature and pressure). setting accuracy.
3. Mist separator and micro-mist separator 3. Lubricator
Design the system so that the mist separator and micro-mist 1) Please contact SMC when the lubricator is used in high
separator are installed where there is less pulsation. A pressure frequency operations, such as in a press.
difference between internal and external pressure inside the 2) Lubrication cannot be properly performed if the operating
element should be kept within 0.1 MPa, as exceeding this value flow rate is too low. Select proper size lubricator by referring
can cause damage. the minimum dripping flow rate provided in this catalog.
4. Regulator and filter regulator 3) Avoid the use of a lubricator that causes back flow as this
Air consumption is 0.1 L/min (ANR) or less under standard may cause damage to internal parts.
specifications. Please consult with SMC, if this value is not 4) Use a check valve (Series AKM) to prevent the lubricant
allowable. from back flowing when redirecting the piping on the inlet
5. F.R.L. side.
1) When using a 2-unit combination such as AC0A, AC0B, 4. Float-type auto drain
and AC0D, secure the top and bottom of the bracket. For Use auto drain under the following conditions to avoid
3-unit, securing the bottom side of the bracket is malfunction.
recommended. <N.O. type>
2) The bracket position varies depending on the attachment (T- • Operating compressor: 0.75 kW (100 L/min (ANR)) or more
interface or pressure switch) mounting. When using 2 or more auto drains, multiply the above value
3) The standard mounting position for bracket is OUT side of by the number of auto drains to find the capacity of the
each component (AF, AR, AL, AW, AFM, and AKM). Refer to compressors you will need.
the table on page 14-2-30 for pitches and dimensions of the For example, when using 2 auto drains, 1.5 kW (200 L/min
bracket when mounting the attachment. (ANR)) of the compressor capacity is required.
4) Brackets cannot be mounted on both sides of a T-interface or • Operating pressure: 0.1 MPa or more
pressure switch. <N.C. type>
5) Please contact SMC if your wish to change the bracket • Operating pressure for AD17, AD27: 0.1 MPa or more
mounting position. • Operating pressure for AD37, AD47: 0.15 MPa or more

14-2-2
3

F.R.L. (Filter/Regulator/Lubricator)
Precautions 2
Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety
Instructions and Common Precautions on the products mentioned in this
catalog, and refer to main text for more detailed precautions on every series.

Mounting Piping F.R.L.


Caution Warning AV
1. To avoid reversed connections of the air inlet/outlet, make 1. To screw piping materials into components, tighten with a
connections after confirming the “IN/OUT” mark or arrows that recommended tightening torque while holding the female
indicate the direction of air flow. Reversed connections can thread side. If the minimum tightening torque is not observed,
AU
cause malfunction. this can cause a looseness and seal failure. On the other
2. Components with a bowl, e.g., air filter, filter regulator, lubricator, hand, excess tightening torque can cause damage to the AF
threads. Furthermore, tightening without holding the female
must be installed vertically with the bowl downward so that
faulty drain discharge and dripping can be verified.
thread side can cause damage due to the excess force that is AR
applied directly to the piping bracket.
3. Ensure sufficient top, bottom, and front clearance for
maintenance and operation of each component. Refer to the Recommended Tightening Torque (N⋅m)
IR
dimensions section for the minimum clearance for each Connection
M5 1/8 1/4 3/8 1/2 3/4 1
component.
thread
VEX
Torque ∗ 7 to 9 12 to 14 22 to 24 28 to 30 28 to 30 36 to 38
4. Regulator and filter regulator
∗ After tightening by hand, tighten further approximately 1/6 turn AMR
Be sure to unlock the knob before adjusting the pressure and to
using a tightening tool.
lock it after the pressure is set.
ITV
Adjustment IC
Warning VBA
1. Regulator and filter regulator
1) Set the regulator while verifying the displayed values of the VE
inlet and outlet pressure gauges. Turning the knob excessively
can cause damage to the internal parts. VY1
2) Do not use a tool on the pressure regulator knob as this can
cause damage. It must be operated manually.
G
2. Avoid excessive torsional moment or bending moment other
Caution than those caused by the equipment’s own weight as this can PPA
1. Regulator and filter regulator cause damage. Support external piping separately.
1) Be sure to check the inlet pressure before setting the outlet AL
pressure.
2) The pressure gauge included with regulators for 0.02 to 0.2
MPa setting is for up to 0.2 MPa only. Do not apply pressure
exceeding 0.2 MPa. It can damage the pressure gauge.
3) To set the pressure using the knob, turn the knob in the
direction that increases pressure and lock the knob after the
pressure is set. If this is done in the direction that decreases
pressure, the pressure may drop from the original set pressure.
Turning the knob clockwise increases the outlet pressure, and
turning it counterclockwise reduces the pressure.

3. Piping materials without flexibility such as steel tube piping are


prone to be affected by excess moment load and vibration
from the piping side. Use flexible tubing in between to avoid
such an effect.

14-2-3
4

F.R.L. (Filter/Regulator/Lubricator)
Precautions 3
Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety
Instructions and Common Precautions on the products mentioned in this
catalog, and refer to main text for more detailed precautions on every series.

Piping Maintenance
Caution Warning
1. Lubricator 5. Mist separator, Micro mist separator
Try to avoid riser piping and branch lines as much as possible 1) Replace the element every 2 years or when the pressure
on the outlet side, otherwise proper lubrication will be drop becomes 0.1 MPa, whichever comes first, to prevent
compromised. damage to the element.
2. Float type auto-drain 2) Release accumulated condensate periodically before it
Drain piping should be performed under the following reaches the maximum capacity. Condensate that flows out
conditions to avoid malfunction. to the outlet side can cause malfunctions.
<N.O. type>
• Use piping whose I.D. is ø6.5 or larger, and whose length is 5
6. Lubricator
m or less. Avoid riser piping. 1) Use class 1 turbine oil (without additives) ISO VG32. Using
<N.C. type> other lubricant can cause damage to devices and result in
• AD17/27: Use piping whose I.D. is ø2.5 or larger malfunctions.
AD37/47: Use piping whose I.D. is ø4 or larger 2) For AL10 and AL20 type, replenish the lubricant after
Length is 5 m or less. Avoid riser piping. releasing the inlet pressure as lubricant cannot be properly
applied in a pressurized condition.

Caution
Air Supply 1. Perform periodical inspections of the filter element and replace
it as necessary. Check the element whenever the outlet
pressure drops below normal or air does not flow smoothly
Caution during operation.
1. When there is excessive condensate, install a device that
2. Regulator and filter regulator
eliminates water such as a dryer or water separator (Drain
Check the sliding part or seat of the internal valve when a
Catch) on the inlet side of the air filter.
setting malfunction or relief leakage occur and temporary or
emergency repairs need to be made.
3. Lubricator
Check the dripping amount once a day. Drip failure can cause
Maintenance damage to the components being lubricated.

Warning 4. Float type auto drain


1) Turn the knob counterclockwise to release the drain
1. When disassembly or installation is required during the
manually. Avoid applying excessive torque to the knob, such
maintenance, repair, or replacement of a device, be sure to
as by using a tool, as this can damage an auto drain.
follow the instructions provided in the instruction manual or
After releasing the condensate, turn the knob clockwise until
safety instructions in this catalog.
it stops.
2. Perform periodical inspections to detect any cracks, scratches,
or other deterioration of the transparent resin bowl of the air 2) Air leakage or other performance malfunctions can occur if
filter, filter regulator, and lubricator or the sight dome of the premature clogging of the element or pressure drop causes
lubricator. the pressure inside the bowl to get outside the specified
Replace with a new bowl, sight dome, or metal bowl when any pressure range parameters. Check the pressure whenever
kind of deterioration is found, otherwise this can cause such an irregularity occurs.
damage.
3. Perform periodical inspections to detect dirt on the transparent
resin bowl of the air filter, filter regulator, and lubricator or the
sight dome of the lubricator. When you find dirt on any of the
above devices, clean with a mild household cleanser. Do not
use other cleaning agents, otherwise this can cause damage.
4. Air filter
1) Replace the element every 2 years or when the pressure
drop becomes 0.1 MPa, whichever comes first, to prevent
damage to the element.
2) Release accumulated condensate periodically before it
reaches the maximum capacity. Condensate that flows out
to the outlet side can cause malfunctions.

14-2-4
5

Modular F.R.L. Unit

Series AC
F.R.L.
AV
AU
AF
AR
IR
VEX
AMR
ITV
IC
VBA
VE
VY1
G
PPA
AL

Introducing our latest F.R.L. units

14-2-5
6

Space-saving design Reduction

The use of compact spacer with bracket

New
reduces the total assembling space.
Model Reduction
New Old (mm)
AC10 AC1000 4 Improved visibility
AC20 AC2000 14 for lubricant drip
AC25 AC2500 14 with graduation for lubricant
control
AC30 AC3000 14
Old

AC40 AC4000 18 Graduation

AC40-06 AC4000-06 18
AC50 AC5000 18
5
6

AC55 AC5500 18
4

SMC
8

2
AC60 AC6000 18 Spacer with
9 1

bracket

Embedded pressure gauge


is a standard feature.
Ozone resistant rubber material (HNBR)
Improved relief sensitivity

Float type auto-drain with excellent


operability is used for compact
models (AF10/20).
Drain cock is easy-to-use rotary type. Improved installation
Bracket with spacer
Retainer

Knob cover
Prevents careless knob operation.

Lock cover
Lever pin

Keyhole dia.: ø8 1. Attach the component into the fitting of the spacer with
bracket.
2. Lock the lever pin into the retainer. (Temporary installation)

Lock Bolt
(provided by customers)
Part no. Model
AC20, AR20, AR20K, AW20,
AR20P-580AS
AW20K, AWM20, AWD20
AR25P-580AS AC25, AR25, AR25K
AC30, AR30, AR30K, AW30,
AR30P-580AS
AW30K, AWM30, AWD30
AC40(-06), AR40(-06),
AR40P-580AS AR40K(-06), AW40(-06),
AW40K(-06), AWM40, AWD40 3. Tighten the bolt.

14-2-6
7

Standard Combination
Component
Combination Model Port
size Air filter Regulator Lubricator Filter regulator Mist separator
AF AR AL AW AFM

AF + AR + AL AC10 M5 x 0.8 AF10 AR10 AL10


AC20 1/8, 1/4 AF20 AR20 AL20
AC25 1/4, 3/8 AF30 AR25 AL30
F.R.L.
AC30 1/4, 3/8 AF30 AR30 AL30
AC40 1/4, 3/8, 1/2 AF40 AR40 AL40 AV
AC40-06 3/4 AF40-06 AR40-06 AL40-06
AU
AC50 3/4, 1 AF50 AR50 AL50
AC55 1 AF60 AR50 AL60 AF
AC60 1 AF60 AR60 AL60
AR
AW + AL AC10A M5 x 0.8 AL10 AW10
AC20A 1/8, 1/4 AL20 AW20 IR
AC30A 1/4, 3/8 AL30 AW30
VEX
AC40A 1/4, 3/8, 1/2 AL40 AW40
AC40A-06 3/4 AL40-06 AW40-06 AMR
AF + AR AC10B M5 x 0.8 AF10 AR10
ITV
AC20B 1/8, 1/4 AF20 AR20
AC25B 1/4, 3/8 AF30 AR25 IC
AC30B 1/4, 3/8 AF30 AR30
VBA
AC40B 1/4, 3/8, 1/2 AF40 AR40
AC40B-06 3/4 AF40-06 AR40-06 VE
AC50B 3/4, 1 AF50 AR50
VY1
AC55B 1 AF60 AR50
AC60B 1 AF60 AR60 G
AF + AFM + AR AC20C 1/8, 1/4 AF20 AR20 AFM20
PPA
AC25C 1/4, 3/8 AF30 AR25 AFM30
AC30C 1/4, 3/8 AF30 AR30 AFM30 AL
AC40C 1/4, 3/8, 1/2 AF40 AR40 AFM40
AC40C-06 3/4 AF40-06 AR40-06 AFM40-06
AW + AFM AC20D 1/8, 1/4 AW20 AFM20
AC30D 1/4, 3/8 AW30 AFM30
AC40D 1/4, 3/8, 1/2 AW40 AFM40
AC40D-06 3/4 AW40-06 AFM40-06

Table of Contents
 F.R.L. Unit  Modular Style Air Filter  Modular Style Lubricator
Air Filter + Regulator + Lubricator Air Filter Lubricator
AC10 to 60·································· Page 14-2-5 AF10 to 60·································· Page 14-2-34 AL10 to 60·································· Page 14-2-61
Filter Regulator + Lubricator Made to Order Specifications········ Page 14-2-39
AC10A to 40A····························· Page 14-2-16 Mist Separator  Modular Style Filter Regulator
Air Filter + Regulator AFM20 to 40······························· Page 14-2-40 Filter Regulator
AC10B to 60B····························· Page 14-2-18 Micro Mist Separator AW10 to 40································· Page 14-2-67
Air Filter + Mist Separator + Regulator AFD20 to 40································ Page 14-2-43 Made to Order Specifications········ Page 14-2-72
AC20C to 40C····························· Page 14-2-20 Filter Regulator with Back Flow Mechanism
Filter Regulator + Mist separator  Modular Style Regulator AW20K to 40K···························· Page 14-2-74
AC20D to 40D····························· Page 14-2-22 Regulator Mist Separator Regulator
Attachment Specifications············· Page 14-2-24 AR10 to 60·································· Page 14-2-47 AWM20 to 40······························ Page 14-2-78
Spacers and Brackets: Made to Order Specifications········ Page 14-2-53 Micro Mist Separator Regulator
Accessory··································· Page 14-2-29 Regulator with Back Flow Mechanism AWD20 to 40······························ Page 14-2-82
Made to Order Specifications········ Page 14-2-31 AR20K to 60K····························· Page 14-2-54

14-2-7
8

Simple Specials System


A system designed to respond quickly and
easily to your special ordering needs.

Simple Specials Order Specifications


1. Modular/Attachment combination & Combination order
Attachment symbols:
Piping adapter: E0
Pressure switch: IS1000
Check valve: AKM
Cross interface: Y4
Residual pressure relief 3 port valve: VHS
2. Modular products, Combination of special order
numbers & Combination order
Special orders for AF, AR, AL, AW, AF, AW

Short lead times


This system enables us to respond
to your special needs, such as
additional machining, accessory
assembly, or modular unit, and
deliver such special products as
quickly as standard products.

Repeat orders
As soon as we receive a Simple Special part
number from your previous order, we will
process the order, manufacture the product, and
deliver it to you.

Please contact SMC for further details on the Simple Specials System.

14-2-8
9

F.R.L. Unit Series AC


How to Order

AC 30 A F 03 DE KV 12R
Option
F.R.L. unit Symbol Description Applicable model
1 (11) 0.02 to 0.2 MPa setting AC10 to 60
Body size
2 Metal bowl AC10 to 60
10 20 25 30 40 50 55 60
3 Lubricator with drain cock AC10 to 60
6 Nylon bowl AC10 to 60
F.R.L.
8 Metal bowl with level gauge AC25 to 60
C With bowl guard AC25 to 60
AV
J (12) Drain guide 1/4 AC10 to 60
Model combination
N Non-relieving type AC10 to 60
Combination AU
Symbol Filter Mist R Flow direction: Right  Left AC10 to 60
Air filter Regulator Lubricator regulator separator
Nil (1) (2) (3) — — W Drain cock with barb fitting:
ø6 x ø4 nylon tubing
AC25 to 60 AF
A — — (2) (1) —
(13)
B (1) (2) — — — Z
Name plate, caution plate for bowl, and
pressure gauge in imperial units (PSI, °F)
AC10 to 60 AR
C (1) (3) — — (2)
∗ When more than one specification is required, indicate
D — — — (1) (2) in ascending alphanumeric order.
IR
Note 1) The number inside ( ) indicates the Note 11) The only difference from the standard
combination order counted from the specifications is the adjusting spring for VEX
inlet side. the regulator. It does not restrict the
setting of 0.2 MPa or more.
Note 12) Without a valve function. AMR
Note 13) For thread types M5 and NPT.
This product is for overseas use only
Thread type according to the new Measurement Law.
ITV
(The SI unit type is provided for use in
Metric system thread (M5)
Nil Japan.) IC
Rc Pressure switch comes with a dual unit
N (2) NPT scale in SI (MPa) and imperial (PSI)
units. VBA
F (3) G Attachment
Note 2) Drain guide is NPT 1/4 (applicable to AC25 Port size for
to 60), and the exhaust port for auto-drain Symbol Description Attachment
mounting position
Applicable
model
intermediate
air release
VE
comes with ø3/8" One-touch fitting Nil None — — —
(applicable to AC25 to 60).
AF + AR + [K] + AL AC20 to 40 AC20: 1/8 VY1
Note 3) Drain guide is G 1/4 (applicable to AC25 to AC25: 1/4
60). K Check valve
AC30: 1/4
AW + [K] + AL AC20A to 40A AC40: 3/8 G
AF + AR + [S] + AL AC20 to 60
Port size
AW + [S] + AL AC20A to 40A PPA
Port Body size Pressure
Symbol size S AF + [S] + AR AC20B to 60B —
switch
10 20 25 30 40 50 55 60
AF + AFM + [S] + AR AC20C to 40C AL
M5 M5 ● — — — — — — —
AW + [S] + AFM AC20D to 40D
01 1/8 — ● — — — — — —
AC10: M5 x 0.8
02 1/4 — ● ● ● ● — — — AF + [T] + AR + AL AC10 to 60AC20: 1/8
03 3/8 — — ● ● ● — — — AC25: 1/4
T T-interface AC30: 1/4
04 — — — — ● — — — AF + [T] + AR AC10B to 60B AC40: 3/8
1/2
AC50: 3/8
06 3/4 — — — — ● ● — —
AF + AFM + [T] + AR AC20C to 40C AC55: 1/2
10 1 — — — — — ● ● ● AC60: 1/2
AF + AR + AL + [V] AC20 to 50
AW + AL + [V] AC20A to 40A
Residual
V pressure relief AF + AR + [V] AC20B to 50B —
3 port valve
Accessory AF + AFM + AR + [V] AC20C to 40C
Symbol Description Applicable model AW + AFM + [V] AC20D to 40D
Nil — — [V] + AF + ARK AC20B to 50B
Residual
C Float type auto-drain (N.C.) (4) AC10 to 60 V1 pressure relief [V] + AF + AFM + ARK AC20C to 40C —
3 port valve
D Float type auto-drain (N.O.) (4) AC25 to 60 [V] + AWK + AFM AC20D to 40D
E With square embedded type pressure gauge (With limit indicator) AC20 to 60 Note 6) When more than one attachment is required, order in
With round pressure gauge (Without limit indicator)
alphabetical order.
(5) AC10
G Note 7) Piping adapter, pressure switch with piping adapter,
With round pressure gauge (With limit indicator) AC20 to 60 and cross interface need to be ordered separately.
Note 4) Applicable tubing O.D for auto-drain connection should be Note 8) Please contact SMC when using a pressure switch
ø3/8" in case NPT thread port is chosen. and T-interface together for ACB.
Note 5) Mounting thread for pressure gauge: Note 9) The bracket position varies depending on the T-
1/16 for AC10; 1/8 for AC20 to 30; 1/4 for AC40 to 60 interface or pressure switch mounting. Refer to the
Pressure gauge is not mounted and is supplied loose at the table on page 14-2-30 for standard bracket position.
time of shipment. Note 10) With this combination, regulators and filter regulators
will be “with back flow function” type.
For safety, check that the outlet pressure is exhausted
and is atmospheric pressure by pressure gauge.
14-2-9
10

Series AC
Accessory/Optional Specifications Combination
: Combination available : Combination not available : Varies depending on the model : Available only with NPT thread
F.R.L. unit applicable model

Symbol
Combination Accessory Optional specifications
Accessory/ AC10 AC20 AC20B AC25B AC30 AC30A AC30B AC30C AC30D
AC10B AC20C AC25 to to
Optional specifications C D E G 1 2 3 6 8 C J N R WZ AC10A AC20A AC20D AC25C AC60 AC40A AC60B AC40C AC40D

Float type auto-drain (N.C.) C


Accessory

Float type auto-drain (N.O.) D


Square embedded type
pressure gauge E
Round pressure gauge G
0.02 to 0.2 MPa setting -1
Metal bowl -2
Lubricator with drain cock -3
Optional specifications

Nylon bowl -6
Metal bowl with level gauge -8

With bowl guard -C


Drain guide 1/4 -J
Non-relieving type -N
Flow direction: Right Left -R
Drain cock with barb fitting:
ø6 x ø4 nylon tubing -W
Name plate, caution plate for bowl, and
pressure gauge in imperial units (PSI, °F) -Z

Attachment
Port size Function

M5 x 0.8 Allows installation/removal of the component P. 14-2-24


Piping adapter 1/8, 1/4, 3/8, 1/2, 3/4, 1 without removing the piping.

M5 x 0.8 P. 14-2-24
T-interface 1/8, 1/4, 3/8, 1/2
Redirects the air flow.

Pressure switch 1/8, 1/4, 3/8, 1/2, 3/4


Compact switch and piping adapter P. 14-2-25
with piping adapter integrated into one piece.

Check valve 1/8, 1/4, 3/8 Prevents back flow from lubricator. P. 14-2-26

Pressure switch — Compact switch P. 14-2-27

M5 x 0.8 P. 14-2-27
Cross interface 1/8, 1/4, 3/8, 1/2
Allows piping in all 4 directions.

Residual pressure relief 1/8, 1/4, 3/8, 1/2, 3/4, 1 Releases residual pressure in lines. P. 14-2-28
3 port valve

Attachment Accessory Made to Order Specifications


Refer to pages 14-2-29 to 30 for interfaces and brackets. Refer to page 14-2-31 for details.

14-2-10
11

F.R.L.
AV
AU
AF
AR
IR
VEX
AMR
ITV
IC
VBA
VE
VY1
G
PPA
AL

14-2-11
12

F.R.L. Unit Air Filter + Regulator + Lubricator

Series AC10 to 60
P. 14-2-31

JIS Symbol

AC20 AC40 Air filter Regulator Lubricator

Standard Specifications
Model AC10 AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60
Air filter AF10 AF20 AF30 AF30 AF40 AF40-06 AF50 AF60 AF60
Component Regulator AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR50 AR60
Lubricator AL10 AL20 AL30 AL30 AL40 AL40-06 AL50 AL60 AL60
1/8 1/4 1/4 1/4 3/4
Port size M5 x 0.8 3/8 3/4 1 1
1/4 3/8 3/8 1/2 1
(1)
Pressure gauge port size 1/16 1/8 1/8 1/8 1/4 1/4 1/4 1/4 1/4
Fluid Air
Proof pressure 1.5 MPa
Max. operating pressure 1.0 MPa
Set pressure range 0.05 to 0.7 MPa 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (2) (at relief flow rate of 0.1 l /min (ANR))
Ambient and –5 to 60°C (With no freezing)
fluid temperature
Nominal filtration rating 5 µm
Recommended lubricant Class 1 turbine oil (ISO VG32)
Bowl material Polycarbonate
Bowl guard — Option Standard
Regulator construction Relieving type
Weight (kg) 0.27 0.73 0.91 1.00 1.74 1.95 4.17 4.25 4.34
Note 1) Pressure gauge connection threads are not required for F.R.L. unit with a square embedded type pressure gauge (AC20 to AC60).
Note 2) Not applicable to AC10.

Attachment/Accessory Part No.


Part no.
Description Model
AC10 AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60
(1)

G-27-10-R1 G36-10-01 G36-10-01 G36-10-01 G46-10-02 G46-10-02 G46-10-02 G46-10-02 G46-10-02


Pressure gauge

Round type
1.0 MPa Square (2)
embedded type — GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS
Accessory

(3)
Round type G-27-10-R1 G36-2-01 G36-2-01 G36-2-01 G46-2-02 G46-2-02 G46-2-02 G46-2-02 G46-2-02
0.2 MPa Square (2)
embedded type — GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS
(4)
Float type N.O. — — AD38 AD38N (7) AD38 AD38N (7) AD48 AD48N (7) AD48 AD48N (7) AD48 AD48N (7) AD48 AD48N (7) AD48 AD48N (7)
auto-drain N.C. AD17 AD27 AD37 AD37N (7) AD37 AD37N ( 7) AD47 AD47N (7) AD47 AD47N (7) AD47 AD47N (7) AD47 AD47N (7) AD47 AD47N (7)
Spacer Y100 Y200 Y300 Y300 Y400 Y500 Y600 Y600 Y600
Check valve (5) (6) — AKM2000-(0201) AKM3000-(0102) AKM3000-(0102) AKM4000-(0203) — — — —
Pressure switch (6) — IS1000M-20 IS1000M-30 IS1000M-30 IS1000M-40 IS1000M-50 IS1000M-60 IS1000M-60 IS1000M-60
01 03
T-interface (5) Y110-M5 Y210- (02) Y310- (01) Y310-(01) Y410-(02) Y510-(02) Y610-(04) Y610-(03) Y610-(03)
Attachment

(6) 02 02 03 03 04 04


02
06
Residual pressure (6)
relief 3 port valve — VHS20- 01 02
02 VHS30- 03 VHS30- 03
02
VHS40- VHS40-06 VHS50-(10)
03
04 — —
(6) 01 02 02 02
Piping adapter E100-M5 E200- 02
03
E300- 03
04
E300- 03
04
E400- 03
04 E500-06 E600- 06
10 E600- 06
10 E600- 06
10
06
(6)
01 02 02 02
Pressure switch 03
with piping adapter — IS1000E-20 02 IS1000E-30 03 IS1000E-3003 IS1000E-40 04 — — — —
03 04 04
06
(6)
Cross interface Y14-M5 Y24- 01
02 Y34- 01
02 Y34- 01
02 Y44- 02
03 Y54- 03
04 — — —
Note 1)  in part numbers for a round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N
for NPT.
Please contact SMC regarding the connection thread NPT and pressure gauge supply for PSI unit specifications.
Note 2) Includes one O-ring and 2 mounting screws.
Note 3) For 1.0 MPa.
Note 4) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.15 MPa (AD17/27).
Note 5) For F.R.L. units, port sizes not in ( ) are for standard application.
Note 6) Separate interfaces are required for modular unit.
Note 7) When “N” is specified in the end of part number of auto-drain, applicable tubing O.D should be ø3/8".

14-2-12
13

F.R.L. Unit Series AC10 to 60


Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa

AC10 M5 x 0.8 AC40-06 Rc 3/4 Selection


0.6 0.6
Warning
Outlet pressure (MPa)

Outlet pressure (MPa)


0.5 0.5 1. Float type auto-drain
0.4 0.4 Operate under the following conditions to
avoid malfunction.
0.3 0.3
<N.O. type>
0.2 0.2 • Operating compressor: 0.75 kW (100 l/min
(ANR)) or more. F.R.L.
0.1 0.1
When using 2 or more auto drains, multiply
the value above by the number of auto-
00 25 50 75 100 125 150 00 1000 2000 3000 4000 5000
drains to find the capacity of the
AV
Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
compressors you will need.
AC20 Rc 1/4 AC50 Rc 1 For example, when using 2 auto-drains, AU
0.6 0.6 1.5 kW (200 l/min (ANR)) of the
compressor capacity is required. AF
Outlet pressure (MPa)

Outlet pressure (MPa)

0.5 0.5
• Operating pressure: 0.1 MPa or more.
0.4 0.4 <N.C. type> AR
0.3 0.3
• Operating pressure for AD17, AD27:
0.1 MPa or more.
0.2 0.2
IR
• Operating pressure for AD37, AD47:
0.15 MPa or more.
0.1 0.1
2. Use a regulator or filter regulator with a
VEX
0 0
0 200 400 600 800 0 2000 4000 6000 8000 10000 back flow mechanism when mounting a 3
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) port valve for residual pressure release on AMR
AC25 Rc 3/8 AC55 Rc 1 the IN side to ensure the release of the
0.6 0.6
residual pressure. Otherwise, residual ITV
pressure will not be fully released.
Outlet pressure (MPa)

Outlet pressure (MPa)

0.5 0.5
Caution IC
0.4 0.4
1. When releasing air at the intermediate
0.3 0.3 position using a T-interface on the inlet side
VBA
0.2 of the lubricator, lubricant may back flow.
0.2
Therefore, releasing air that does not VE
0.1 0.1 contain traces of lubricant is not possible.
0 0
To release air that does not contain traces VY1
0 500 1000 1500 0 2000 4000 6000 8000 10000 of lubricant, use a check valve (Series
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) AKM) on the inlet side of the lubricator to
prevent a back flow of the lubricant.
G
AC30 Rc 3/8 AC60 Rc 1
2. Mounting a 3 port valve for residual
0.6 0.6
pressure release on the IN side of the PPA
Outlet pressure (MPa)

Outlet pressure (MPa)

0.5 0.5 lubricator can cause lubricant to back flow.


0.4 0.4
Take measures to prevent lubricant from AL
splashing by installing a filter on the EXH
0.3 0.3 port.
0.2
3. An F.R.L. unit shipped from the plant has
0.2
its model number labeled. However,
0.1 0.1 components that are combined together
during the distribution process do not have
0 0
0 500 1000 1500 0 2000 4000 6000 8000 10000 a label on them.
Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
4. Please contact SMC when mounting a
AC40 Rc 1/2 pressure switch, T-interface, or filter
regulator on the OUT side of the 3 port
0.6
Precautions valve for residual pressure release.
Outlet pressure (MPa)

0.5

0.4
Mounting and Adjustment Air Supply
0.3 Caution Caution
0.2 1. A knob cover is available to prevent 1. Use an air filter with 5 µm or less filtration
careless operation of the knob. Refer to rating on the inlet side of the valve to avoid
0.1 page 14-2-6 for details. any damage to the seat caused by dust
0
0 1000 2000 3000 Piping when mounting a 3 port valve for residual
Flow rate (l/min (ANR)) pressure release on the inlet side.
Warning
1. When mounting a check valve, make
sure the arrow (IN side) points in the
correct direction of air flow.

14-2-13
14

Series AC10 to 60
Conditions:
Inlet pressure 0.7 MPa
Outlet pressure 0.2 MPa
Pressure Characteristics (Representative values) Flow rate 20 l/min (ANR)

AC10 AC40-06
0.3
0.25
Outlet pressure (MPa)

Outlet pressure (MPa)


Set point
0.25
Set point
0.2

0.2

0.15
0.15
0 0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa) Inlet pressure (MPa)

AC20 AC50
0.25 0.25
Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point

0.2 0.2

0.15 0.15

0 0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa) Inlet pressure (MPa)

AC25 AC55
0.25 0.25
Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point

0.2 0.2

0.15 0.15

0 0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa) Inlet pressure (MPa)

AC30 AC60
0.25 0.25
Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point

0.2 0.2

0.15 0.15

0 0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa) Inlet pressure (MPa)

AC40
0.25
Outlet pressure (MPa)

Set point

0.2

0.15

0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Inlet pressure (MPa)

14-2-14
15

F.R.L. Unit Series AC10 to 60


Dimensions
Pressure gauge port size
AC10/20 A P G
E F Q
øL

H
IN OUT

H
L

J
OUT

Pressure gauge

B
(Option)
K Square embedded type M F.R.L.
pressure gauge
(Option)
AV
Drain
Port size N
Air filter Regulator Lubricator Min. clearance AU

D
for maintenance
AC25/30/40/50/55/60 Pressure gauge port size
A P G AF
E F Q
øL
AR

H
C
IN OUT
IR

H
L

OUT

B Pressure gauge
VEX
(Option)
K M
Square embedded type
AMR
pressure gauge
(Option) ITV
Port size

Drain N IC
Min. clearance

D
Air filter Regulator Lubricator for maintenance
VBA
Applicable model AC10, AC20 AC25, AC30, AC40, AC40-06, AC50, AC55, AC60
With auto-drain (N.C.) Metal bowl With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting
VE
Optional VY1
B

B
B

B
B

specifications
B

N.O.: Black
G
B

O S N.C.: Gray O
S
M5 x 0.8 ø10 One-touch 1/4 Barb fitting
fitting Width across flats 17 Applicable tubing: T0604
PPA
(mm)
Standard specifications Accessory specifications
AL
Model Port size Bracket mounting size With pressure gauge With auto-drain
A B C D
E F G H J K L øL M N P Q T B
AC10 M5 x 0.8 87 85 26 35 28 31 25 20 27 7 4.5 4.5 2.8 40 26 — 0 104
AC20 1/8, 1/4 126 123 36 60 41.5 43 30 24 33 12 5.5 5.5 3.2 50 65 29.5 2 (1) 141
AC25 1/4, 3/8 167 153 38 80 55 57 41 35 — 14 7 7 4 71 64 28.5 0 194
AC30 1/4, 3/8 167 153 38 80 55 57 41 35 — 14 7 7 4 71 66 30.5 3.5 194
AC40 1/4, 3/8, 1/2 220 187 40 110 72.5 75 50 40 — 18 9 9 4 88 74 35 3.5 226
AC40-06 3/4 235 187 38 110 77.5 80 50 40 — 18 9 9 4.6 88 74 35 3 226
AC50 3/4, 1 282 264 43 110 93 96 70 50 — 20 11 11 6.4 115 84 44.5 3.3 303
AC55 1 292 279 45 110 98 96 70 50 — 20 11 11 6.4 117.5 84 44.5 3.3 318
AC60 1 297 280 46 110 98 101 70 50 — 20 11 11 6.4 117.5 84 44.5 3.3 318

Optional specifications (2) Note 1) For AC20 only, the position of the pressure
gauge is above the center of the piping.
Model With barb fitting With drain guide Metal bowl Metal bowl with level gauge Note 2) For optional specifications (with barb fitting,
B B B B with drain guide, with metal bowl, or with level
AC10 gauge), the total length (dimension for B) will
— — 85 —
vary.
AC20 — — 123 —
AC25 161 160 166 186
AC30 161 160 166 186
AC40 195 194 200 220
AC40-06 195 194 200 220
AC50 272 271 276 296
AC55 287 286 292 312
AC60 288 287 293 313

14-2-15
16

F.R.L. Unit Filter Regulator + Lubricator

Series AC10A to 40A


P. 14-2-31

JIS Symbol

AC20A Filter regulator Lubricator


Standard Specifications AC40A
Model AC10A AC20A AC30A AC40A AC40A-06
Filter regulator AW10 AW20 AW30 AW40 AW40-06
Component
Lubricator AL10 AL20 AL30 AL40 AL40-06
1/4
1/8 1/4
Port size M5 x 0.8 3/8 3/4
1/4 3/8 1/2
Pressure gauge port size (1) 1/16 1/8 1/8 1/4 1/4
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Set pressure range 0.05 to 0.7 MPa 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (2) (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating 5 µm
Recommended lubricant Class 1 turbine oil (ISO VG32)
Bowl material Polycarbonate
Bowl guard — Option Standard
Filter regulator construction Relieving type
Weight (kg) 0.20 0.59 0.75 1.41 1.46
Note 1) Pressure gauge connection threads are not required for F.R.L. unit with a square embedded type pressure gauge (AC20A to AC40A).
Note 2) Not applicable to AC10A.
Attachment/Accessory Part No.
Part no.
Description Model AC10A AC20A AC30A AC40A AC40A-06
Round type G27-10-R1 G36-10-01 G36-10-01 G46-10-02 G46-10-02
(1) 1.0 MPa (2)

Pressure
Square embedded type — GC3-10AS GC3-10AS GC3-10AS GC3-10AS
Accessory

(3)
gauge Round type G27-10-R1 G36-2-01 G36-2-01 G46-2-02 G46-2-02
0.2 MPa (2)
Square embedded type — GC3-2AS GC3-2AS GC3-2AS GC3-2AS
(4) N.O. — — AD38 AD38N (7) AD48 AD48N (7) AD48 AD48N (7)
Float type auto-drain
N.C. AD17 AD27 AD37 AD37N (7) AD47 AD47N (7) AD47 AD47N (7)
Spacer Y100 Y200 Y300 Y400 Y500
(5) 01
Check valve (6) — AKM2000- (02) AKM3000- (01)
02 AKM4000- (02)
03

(6)
Pressure switch — IS1000M-20 IS1000M-30 IS1000M-40 IS1000M-50
(5) 01 (01) (02)
T-interface Y110-M5 Y210- Y310- Y410- Y510- (02)
Attachment

(6) (02) 02 03 03

(6) 02
Residual pressure relief 3 port valve — VHS20- 01
02 VHS30- 02
03 VHS40- 03
04
VHS40-06
01 02 02
(6) 03
Piping adapter E100-M5 E200- 02
03
E300- 03
04
E400- 04 E500-06
06
(6) 02 02
01
Pressure switch with piping adapter — IS1000E-20 02 IS1000E-30 03
04
IS1000E-40 03
04 —
03 06

Cross interface (6)


Y14-M5 Y24- 01
02 Y34- 01
02 Y44- 02
03 Y54- 03
04

Note 1)  in part numbers for a round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N
for NPT.
Please contact SMC regarding the connection thread NPT and pressure gauge supply for PSI unit specifications.
Note 2) Includes one O-ring and 2 mounting screws.
Note 3) For 1.0 MPa.
Note 4) Minimum operating pressure: N.O. type–0.1 MPa (AD17/27); N.C. type–0.15 MPa (AD37/47).
Note 5) For F.R.L. units, port sizes not in ( ) are for standard application.
Note 6) Separate interfaces are required for modular unit.
Note 7) When “N” is specified in the end of part number of auto-drain, applicable tubing O.D should be ø3/8".

14-2-16
17

F.R.L. Unit Series AC10A to 40A


Dimensions
AC10A/20A
A N F
E P

øK

G
IN OUT

Q
F.R.L.
B

G
K
Pressure gauge

H
OUT

(Option)
Pressure gauge port size
J
Square embedded type AV
pressure gauge L
(Option)

Port size
AU
Lubricator
Drain Min. clearance M AF
Filter regulator for maintenance

D
AR
AC30A/40A A N F
E P IR
VEX
øK
C

AMR

G
IN OUT
Q

ITV
B

G
K

Pressure gauge OUT

Pressure gauge port size


(Option) IC
J Square embedded type L
pressure gauge VBA
(Option)

Port size VE


Drain
Lubricator
Min. clearance M VY1
for maintenance
D

Filter regulator
G
Applicable model AC10A, AC20A AC30A, AC40A, AC40A-06
With auto-drain (N.C.) Metal bowl With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting PPA
AL
Optional
B

B
B

specifications
B

N.O.: Black
B

O S N.C.: Gray O
S
M5 x 0.8 ø10 One-touch 1/4 Barb fitting
fitting Width across flats 17 Applicable tubing: T0604

(mm)
Standard specifications Accessory specifications
Model Port size Bracket mounting size With pressure gauge With auto-drain
A B C D
E F G H J K øK L M N P Q B
AC10A M5 x 0.8 56 108 48 35 28 25 20 27 7 4.5 4.5 2.8 40 26 — 0 126
AC20A 1/8, 1/4 83 160 73 60 41.5 30 24 33 12 5.5 5.5 3.2 50 63 27 5 177
AC30A 1/4, 3/8 110 201 86 80 55 41 35 — 14 7 7 4 71 66 30.5 3.5 242
AC40A 1/4, 3/8, 1/2 145 239 92 110 72.5 50 40 — 18 9 9 4 88 76 38.5 1.5 278
AC40A-06 3/4 155 242 93 110 77.5 50 40 — 18 9 9 4.6 88 76 38.5 1.2 278

Optional specifications Note) Note) For optional specifications (with barb fitting, with drain
guide, with metal bowl, or with level gauge), the total
Model With barb fitting With drain guide Metal bowl Metal bowl with level gauge length (dimension for B) will vary.
B B B B
AC10A — — 107 —
AC20A — — 160 —
AC30A 209 208 214 234
AC40A 247 246 251 272
AC40A-06 250 249 255 275

14-2-17
18

F.R.L. Unit Air Filter + Regulator

Series AC10B to 60B


P. 14-2-31

JIS Symbol

AC20B AC40B
Air filter Regulator
Standard Specifications
Model AC10B AC20B AC25B AC30B AC40B AC40B-06 AC50B AC55B AC60B
Air filter AF10 AF20 AF30 AF30 AF40 AF40-06 AF50 AF60 AF60
Component
Regulator AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR50 AR60
1/8 1/4 1/4 1/4 3/4
Port size M5 x 0.8 3/8 3/4 1 1
1/4 3/8 3/8 1/2 1
(1)
Pressure gauge port size 1/16 1/8 1/8 1/8 1/4 1/4 1/4 1/4 1/4
Fluid Air
Proof pressure 1.5 MPa
Max. operating pressure 1.0 MPa
Set pressure range 0.05 to 0.7 MPa 0.05 to 0.85 MPa
Relief pressure Set pressure + 0.05 MPa (2) (at relief flow rate of 0.1 l/min (ANR))
Ambient and –5 to 60°C (With no freezing)
fluid temperature
Nominal filtration rating 5 µm
Bowl material Polycarbonate
Bowl guard — Option Standard
Regulator construction Relieving type
Weight (kg) 0.16 0.51 0.55 0.63 1.12 1.16 2.44 2.45 2.54
Note 1) Pressure gauge connection threads are not required for F.R.L. unit with a square embedded type pressure gauge (AC20B to AC60B).
Note 2) Not applicable to AC10B.

Attachment/Accessory Part No.


Part no.
Description Model
AC10B AC20B AC25B AC30B AC40B AC40B-06 AC50B AC55B AC60B
(1)
Pressure gauge

Round type G27-10-R1 G36-10-01 G36-10-01 G36-10-01 G46-10-02 G46-10-02 G46-10-02 G46-10-02 G46-10-02
1.0 MPa Square (2)
embedded type — GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS
Accessory

Round type G27-10-R1 (3) G36-2-01 G36-2-01 G36-2-01 G46-2-02 G46-2-02 G46-2-02 G46-2-02 G46-2-02
0.2 MPa Square (2)
— GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS
embedded type
(4)
Float type N.O. — — AD38 AD38N (7) AD38 AD38N (7) AD48 AD48N (7) AD48 AD48N (7) AD48 AD48N (7) AD48 AD48N (7) AD48 AD48N (7)
auto-drain N.C. AD17 AD27 AD37 AD37N (7) AD37 AD37N (7) AD47 AD47N (7) AD47 AD47N (7) AD47 AD47N (7) AD47 AD47N (7) AD47 AD47N (7)
Spacer Y100 Y200 Y300 Y300 Y400 Y500 Y600 Y600 Y600
Pressure switch (6) — IS1000M-20 IS1000M-30 IS1000M-30 IS1000M-40 IS1000M-50 IS1000M-60 IS1000M-60 IS1000M-60
(5) 01 03
T-interface (6) Y110-M5 Y210- (02) Y310-(01)
02 Y310- (01)
02 Y410- (02)
03 Y510- (02)
03 Y610- (04) Y610- (03)
04 Y610- (03)
04
Attachment

(6) 02
02 02
Residual pressure
relief 3 port valve
— VHS20- 01 06
02 VHS30- 03 VHS30- 03 VHS40- 03 VHS40-06 VHS50- 10 — —
04
02
(6) 01 02 02
Piping adapter E100-M5 E200- 02 E300- 03 E300- 03 E400- 03
04 E500-06 E600- 06
10 E600- 06
10 E600- 06
10
03 04 04 06
02
Pressure switch (6) 01 02 02 03
— IS1000E-20 02 IS1000E-30 03 IS1000E-30 03 IS1000E-40 04 — — — —
with piping adapter 03 04 04 06

(6)
Cross interface Y14-M5 Y24- 01
02 Y34- 01
02 Y34- 01
02 Y44- 02
03 Y54- 03
04 — — —
Note 1)  in part numbers for a round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N
for NPT.
Please contact SMC regarding the connection thread NPT and pressure gauge supply for PSI unit specifications.
Note 2) Includes one O-ring and 2 mounting screws.
Note 3) For 1.0 MPa.
Note 4) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.1 MPa (AD17/27), 0.15 MPa (AD37/47).
Note 5) For F.R.L. units, port sizes not in ( ) are for standard application.
Note 6) Separate interfaces are required for modular unit.
Note 7) When “N” is specified in the end of part number of auto-drain, applicable tubing O.D should be ø3/8".

14-2-18
19

F.R.L. Unit Series AC10B to 60B


Dimensions
AC10B/20B A Pressure gauge port size
F P E
øK

N
Q

G
IN OUT

T
K

G
H
Pressure gauge

B
(Option)
J Square embedded type L
pressure gauge F.R.L.
(Option)
Port size AV
Min. clearance M
Drain

D
Air filter Regulator for maintenance AU
AC25B/30B/40B/50B/55B/60B
F ø
A
Pressure gauge port size AF
P E
K
N

Q
AR

G
C

IN OUT IR

T
VEX

G
K

Pressure gauge
B

(Option)
J L AMR
Square embedded type
pressure gauge
(Option) ITV
Port size
IC
Drain Min. clearance
M
D

Air filter Regulator for maintenance


VBA
Applicable model AC10B, AC20B AC25B, AC30B, AC40B, AC40B-06, AC50B, AC55B, AC60B
With auto-drain (N.C.) Metal bowl With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting VE
Optional VY1
B

B
B
B

specifications
B

N.O.: Black
G
B

O S N.C.: Gray O
S
M5 x 0.8 ø10 One-touch 1/4 Barb fitting
fitting Width across flats 17 Applicable tubing: T0604
PPA
(mm)
Standard specifications Accessory specifications AL
Model Port size Bracket mounting size With pressure gauge With auto-drain
A B C D
E F G H J K ØK L M N P Q T B
AC10B M5 x 0.8 56 71 11 25 25 28 20 27 7 4.5 4.5 2.8 40 13.5 26 — 0 89
AC20B 1/8, 1/4 83 114 26.5 40 30 41.5 24 33 12 5.5 5.5 3.2 50 2.5 65 29.5 2 (1) 132
AC25B 1/4, 3/8 110 143 28 50 41 55 35 — 14 7 7 4 71 13 64 28.5 0 184
AC30B 1/4, 3/8 110 146 31 50 41 55 35 — 14 7 7 4 71 10 66 30.5 3.5 187
AC40B 1/4, 3/8, 1/2 145 183 36 75 50 72.5 40 — 18 9 9 4 88 12 74 35 3.5 222
AC40B-06 3/4 155 185 36 75 50 77.5 40 — 18 9 9 4.6 88 12 74 35 3 224
AC50B 3/4, 1 186 264 43 20 70 93 50 — 20 11 11 6.4 115 16 84 44.5 3.3 303
AC55B 1 191 277 43 20 70 98 50 — 20 11 11 6.4 117.5 16 84 44.5 3.3 316
AC60B 1 196 280 46 20 70 98 50 — 20 11 11 6.4 117.5 13 84 44.5 3.3 319
Optional specifications (2) Note 1) For AC20 only, the position of the pressure gauge is above the
center of the piping.
Model With barb fitting With drain guide Metal bowl Metal bowl with level gauge
Note 2) For optional specifications (with barb fitting, with drain guide,
B B B B with metal bowl, or with level gauge), the total length
AC10B — — 70 — (dimension for B) will vary.
AC20B — — 114 —
AC25B 151 150 156 176
AC30B 154 153 159 179
AC40B 191 190 196 216
AC40B-06 193 192 198 218
AC50B 272 271 277 297
AC55B 285 284 290 310
AC60B 288 287 293 313

14-2-19
20

F.R.L. Unit Air Filter + Mist Separator + Regulator

Series AC20C to 40C


P. 14-2-31

JIS Symbol

Standard Specifications AC20C AC40C

Model AC20C AC25C AC30C AC40C AC40C-06


Air filter AF20 AF30 AF30 AF40 AF40-06
Component Mist separator AFM20 AFM30 AFM30 AFM40 AFM40-06
Regulator AR20 AR25 AR30 AR40 AR40-06
1/8 1/4 1/4
1/4
Port size 3/8 3/4
1/4 3/8 3/8 1/2
(1) 1/8 1/8 1/8 1/4 1/4
Pressure gauge port size
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Minimum operating pressure 0.05 MPa
Set pressure range 0.05 to 0.85 MPa
Rated flow (l/min (ANR)) (2) 200 450 450 1100 1100
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating AF: 5 µm; AFM: 0.3 µm (95% filtered particle size)
Outlet side oil mist concentration Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (3)
Bowl material Polycarbonate
Bowl guard Option Standard
Filter regulator construction Relieving type
Weight (kg) 0.74 0.88 0.95 1.76 1.83
Note 1) Pressure gauge connection threads are not required for F.R.L. unit with a square embedded type pressure gauge (AC20C to AC40C).
Note 2) Conditions: Inlet pressure: 0.7 MPa; Set pressure: 0.5 MPa. The rated flow varies depending on the inlet pressure.
Note 3) At compressor discharge 30 mg/Nm3.
Attachment/Accessory Part No.
Part no.
Description Model AC20C AC25C AC30C AC40C AC40C-06
Round type G36-10-01 G36-10-01 G36-10-01 G46-10-02 G46-10-02
(1) 1.0 MPa Square (2)
Pressure embedded type GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS
Accessory

gauge Round type G36-2-01 G36-2-01 G36-2-01 G46-2-02 G46-2-02


0.2 MPa Square (2)
embedded type GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS
Float type
(3) N.O. — AD38 AD38N (6) AD38 AD38N (6) AD48 AD48N (6) AD48 AD48N (6)
auto-drain N.C. AD27 AD37 AD37N (6) AD37 AD37N (6) AD47 AD47N (6) AD47 AD47N (6)
Spacer Y200 Y300 Y300 Y400 Y500
Pressure switch (5) IS1000M-20 IS1000M-30 IS1000M-30 IS1000M-40 IS1000M-50
(4) 01
T-interface (5) Y210- (02) Y310-(01)
02 Y310- (01)
02 Y410- (02)
03 Y510-(02)
03
Attachment

(5) 02
Residual pressure relief 3 port valve VHS20- 01
02 VHS30- 02
03 VHS30- 02
03 VHS40- 03
04
VHS40-06
02
01 02 02 03
(5)
Piping adapter E200- 02
03
E300- 03
04
E300- 03
04
E400- 04 E500-06
06
(5) 02
01 02 02 03
Pressure switch with piping adapter IS1000E-20 02 IS1000E-30 03 IS1000E-30 03 IS1000E-40 04 —
03 04 04 06
01 01 01 02
Cross interface (5)
Y24- 02 Y34- 02 Y34- 02 Y44- 03 Y54- 03
04
Note 1)  in part number for the round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N
for NPT.
Please contact SMC regarding the connection thread NPT and pressure gauge supply for PSI unit specifications.
Note 2) Includes one O-ring and 2 mounting screws.
Note 3) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.1 MPa (AD27), 0.15 MPa (AD37/47).
Note 4) For F.R.L. units, port sizes not in ( ) are for standard application.
Note 5) Separate interfaces are required for modular unit.
Note 6) When “N” is specified in the end of part number of auto-drain, applicable tubing O.D should be ø3/8".
14-2-20
21

F.R.L. Unit Series AC20C to 40C


Dimensions
AC20C A Pressure gauge port size
Q G
E F
Ø
L T

P
C

H
IN OUT

H
L

J
Pressure gauge

B
(Option)
F.R.L.
K Square embedded type M
pressure gauge (Option)
Port size
AV

Min. clearance N AU
Drain Drain

D
for maintenance
Air filter Mist separator Regulator AF
AC25C/30C/40C AR
A Q G
E F Ø
L
Pressure gauge port size T IR
P
VEX

H
C

IN OUT
AMR

H
L

Pressure gauge ITV


B

(Option)
K
Square embedded type
M IC
pressure gauge (Option)
VBA
Port size

VE
N
Drain Drain Min. clearance
VY1
D

for maintenance
Air filter Mist separator Regulator
G
Applicable model AC20C AC25C, AC30C, AC40C, AC40C-06
With auto-drain (N.C.) Metal bowl With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting PPA
AL
Optional
B

B
B

B
B

specifications
B

N.O.: Black
B

O S N.C.: Gray O
S
M5 x 0.8 ø10 One-touch 1/4 Barb fitting
fitting Width across flats 17 Applicable tubing: T0604

(mm)
Standard specifications Accessory specifications
Bracket mounting size With
Model Port size With pressure gauge auto drain
A B C D
E F G H J K L ØL M N P Q T U B
AC20C 1/8, 1/4 126 114 26.5 45 41.5 43 30 24 33 12 5.5 5.5 3.2 50 2.5 65 29.5 2 (1) 132
AC25C 1/4, 3/8 167 143 28 50 55 57 41 35 — 14 7 7 4 71 13 64 28.5 0 184
AC30C 1/4, 3/8 167 146 31 50 55 57 41 35 — 14 7 7 4 71 10 66 30.5 3.5 187
AC40C 1/4, 3/8, 1/2 220 183 36 75 72.5 75 50 40 — 18 9 9 4 88 12 74 35 3.5 222
AC40C-06 3/4 235 185 36 75 77.5 80 50 40 — 18 9 9 4.6 88 12 74 35 3 224

Optional specifications ( 2) Note 1) For AC20 only, the position of the pressure gauge is
above the center of the piping.
Model With barb fitting With drain guide Metal bowl Metal bowl with level gauge Note 2) For optional specifications (with barb fitting, with drain
B B B B guide, with metal bowl, or with level gauge), the total
length (dimension for B) will vary.
AC20C — — 114 —
AC25C 151 150 156 176
AC30C 154 153 159 179
AC40C 191 190 196 216
AC40C-06 193 192 198 218

14-2-21
22

F.R.L. Unit Filter Regulator + Mist Separator

Series AC20D to 40D


P. 14-2-31

JIS Symbol

AC20D AC40D
Standard Specifications
Model AC20D AC30D AC40D AC40D-06

Filter regulator AW20 AW30 AW40 AW40-06


Component
Mist separator AFM20 AFM30 AFM40 AFM40-06
1/8 1/4 1/4
Port size 3/8 3/4
1/4 3/8 1/2
Pressure gauge port size (1) 1/8 1/8 1/4 1/4
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Minimum operating pressure 0.05 MPa
Set pressure range 0.05 to 0.85 MPa
Rated flow (l/min (ANR)) (2) 150 330 800 800
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating AW: 5 µm; AFM: 0.3 µm (95% filtered particle size)
Outlet side oil mist concentration Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (3)
Bowl material Polycarbonate
Bowl guard Option Standard
Filter regulator construction Relieving type
Weight (kg) 0.57 0.74 1.38 1.43
Note 1) Pressure gauge connection threads are not required for F.R.L. unit with a square embedded type pressure gauge (AC20D to AC40D).
Note 2) Conditions: Inlet pressure: 0.7 MPa; Set pressure: 0.5 MPa. The rated flow varies depending on the inlet pressure.
Note 3) At compressor discharge of 30 mg/Nm3.

Attachment/Accessory Part No.


Part no.
Description Model AC20D AC30D AC40D AC40D-06
Round type G36-10-01 G36-10-01 G46-10-02 G46-10-02
(1) 1.0 MPa Square (2)
Pressure embedded type GC3-10AS GC3-10AS GC3-10AS GC3-10AS
Accessory

gauge Round type G36-2-01 G36-2-01 G46-2-02 G46-2-02


0.2 MPa Square (2)
embedded type GC3-2AS GC3-2AS GC3-2AS GC3-2AS
(3) N.O. — AD38 AD38N (6) AD48 AD48N (6) AD48 AD48N (6)
Float type
auto-drain N.C. AD27 AD37 AD37N (6) AD47 AD47N (6) AD47 AD47N (6)
Spacer Y200 Y300 Y400 Y500
Pressure switch (5) IS1000M-20 IS1000M-30 IS1000M-40 IS1000M-50
(4) 01
T-Interface (5) Y210-(02) Y310-(01)
02 Y410-(02)
03 Y510-(02)
03
Attachment

02
Residual pressure relief 3 port valve (5) VHS20- 01
02 VHS30- 02
03 VHS40- 03
04
VHS40-06
02
01 02
Piping adapter (5)
E200- 02
03
E300- 03
04
E400- 03
04 E500-06
06
02
(5) 01 02 03
Pressure switch with piping adapter IS1000E-20 02 IS1000E-30 03 IS1000E-40 04 —
03 04 06
01 01 02
Cross interface (5)
Y24- 02 Y34- 02 Y44- 03 Y54- 03
04
Note 1)  in part number for the round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N
for NPT.
Please contact SMC regarding the connection thread NPT and pressure gauge supply for PSI unit specifications.
Note 2) Includes one O-ring and 2 mounting screws.
Note 3) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.1 MPa (AD27), 0.15 MPa (AD37/47).
Note 4) For F.R.L. units, port sizes not in ( ) are for standard application.
Note 5) Separate interfaces are required for modular unit.
Note 6) When “N” is specified in the end of part number of auto-drain, applicable tubing O.D should be ø3/8".

14-2-22
23

F.R.L. Unit Series AC20D to 40D


Dimensions
AC20D A N F
E P

øK

G
IN OUT

Q
B
F.R.L.

G
H
OUT
Pressure gauge
Pressure gauge (Option)
port size
J Square embedded type L AV
pressure gauge (Option)

Port size
AU
Drain Drain M
Min. clearance AF

D
Filter Mist for maintenance
regulator separator
AR
A N F IR
AC30D/40D E P
VEX
AMR
øK
C

ITV

G
IN OUT Q

IC
B

G
Pressure gauge
K

OUT

Pressure gauge (Option)


port size
VBA
J Square embedded type L
pressure gauge (Option)
VE
Port size
VY1
Min. clearance M
Drain Drain G
D

for maintenance
Filter Mist
regulator separator
PPA
Applicable model AC20D AC30D, AC40D, AC40D-06
With auto-drain (N.C.) Metal bowl With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting AL

Optional
B

B
B
B

specifications
B

N.O.: Black
B

O S N.C.: Gray O
S
M5 x 0.8 ø10 One-touch 1/4 Barb fitting
fitting Width across flats 17 Applicable tubing: T0604

(mm)
Standard specifications Accessory specifications
With
Model Port size Bracket mounting size With pressure gauge auto-drain
A B C D
E F G H J K øK L M N P Q B
AC20D 1/8, 1/4 83 160 73 45 41.5 30 24 33 12 5.5 5.5 3.2 50 63 27 5 177
AC30D 1/4, 3/8 110 201 86 55 55 41 35 — 14 7 7 4 71 66 30.5 3.5 242
AC40D 1/4, 3/8, 1/2 145 239 92 80 72.5 50 40 — 18 9 9 4 88 76 38.5 1.5 278
AC40D-06 3/4 155 242 93 80 77.5 50 40 — 18 9 9 4.6 88 76 38.5 1.2 278

Optional specifications Note) Note) For optional specifications (with barb fitting, with drain guide, with
Model With barb fitting With drain guide Metal bowl Metal bowl with level gauge metal bowl, or with level gauge), the total length (dimension for
B) will vary.
B B B B
AC20D — — 160 —
AC30D 209 208 214 234
AC40D 247 246 251 272
AC40D-06 250 249 255 275

14-2-23
24

F.R.L. Unit Series AC


Attachment Specifications
Piping Adapter (E): M5 x 0.8, 1/8, 1/4, 3/8, 1/2, 3/4, 1
A piping adapter allows installation/removal of the component Port size
without removing the piping and thus makes maintenance easier.

B
Center of
F.R.L. body
A D

(mm)
Model Note) Port size A B D Applicable model
E100-M5 M5 x 0.8 10 14 14 AC10, AW10, AF10, AR10, AL10
E200-01 1/8 AC20
E200-02 1/4 30 23.5 28 AF20, AR20, AW20
E200-03 3/8 AL20, AFM20, AFD20, AWM20, AWD20
Piping adapter E300-02 1/4 AC25, AC30
E300-03 3/8 32 30 30 AF30, AR30, AW30
E300-04 1/2 AL30, AFM30, AFD30, AWM30, AWD30
E400-02 1/4 AC40
E400-03 3/8 AF40, AR40, AW40
32 36 36 AL40, AFM40, AFD40
E400-04 1/2
AWM40, AWD40
E400-06 3/4
AC40-06, AF40-06, AR40-06, AW40-06
E500-06 3/4 32 40 44
AL40-06, AFM40-06, AFD40-06
E600-06 3/4 AC50, AC55, AC60, AC50B, AC55B, AC60B
35 48 53
E600-10 1 AF50, AR50, AL50, AF60, AR60, AL60
Note) •  in model numbers indicates a thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
• Separate interfaces are required for modular unit.
∗ Factory mounting of a piping adapter on the AC models is available as a
special order.

T-interface (T): M5 x 0.8, 1/8, 1/4, 3/8, 1/2


Using a T-interface facilitates the redirection of air flow. E
Octagon Port size
C
B

T-interface

Center of
F.R.L. body
A D
(mm)
Model Port size A B C D E Applicable model
Y110-M5 M5 x 0.8 11 19 12 14 8 AC10, AC10B
Y210-01 1/8 AC20, AC20B
15 42 32 28 19
Y210-02 1/4 AC20C
Y310-01 1/8 AC25, AC25B
15 53 39 30 19 AC25C, AC30
Y310-02 1/4 AC30B, AC30C
Y410-02 1/4 AC40, AC40B
19 62 44 36 24
Y410-03 3/8 AC40C
Y510-02 1/4 AC40-06, AC40B-06
19 66 46 44 24
Y510-03 3/8 AC40C-06
Caution on Mounting AC50, AC55
Y610-03 3/8
• If a T-interface is used on the IN side of the lubricator, lubricant 22 81 57 53 30
AC60, AC50B
Y610-04 1/2 AC55B, AC60B
may be mixed. Use the Series AKM check valve to avoid such
possibility. Note) •  in model numbers indicates a thread type. No indication is
necessary for Rc; however, indicate N for NPT, and F for G.
• Separate interfaces are required for modular unit.
∗ Refer to the attachment table on “Front matter 2” for standard port sizes
when using with AC.

14-2-24
25

Attachment Specifications Series AC


Pressure Switch with Piping Adapter (P)

Approx. 500
Pressure switch with piping adapter
A D
E 23

JIS Symbol

Port size F.R.L.

C
AV

B
AU
Specifications
Fluid Air AF
Proof pressure 1.0 MPa Center of
F.R.L. body
Maximum operating pressure 0.7 MPa AR
Set pressure range (mm)
(When OFF) 0.1 to 0.4 MPa
Differential 0.08 MPa
Model (1) Port size A B C D E Applicable model IR
IS1000E-2001 1/8 AC20
Ambient and fluid temperature –5 to 60°C (With no freezing)
IS1000E-2002 1/4 30 68 57 28 16 AR20, AW20 VEX
IS1000E-2003 3/8 AWM20, AWD20
Switch characteristics
Contact point configuration 1a
IS1000E-3002 1/4 AC25, AC30 AMR
IS1000E-3003 3/8 32 74.5 60.5 30 13 AR25, AR30, AW30
Maximum contact point capacity 2 VA(AC), 2 W(DC)
Operating voltage: AC, DC 100 V or less
IS1000E-3004 1/2 AWM30, AWD30 ITV
IS1000E-4002 1/4
12 V to 24 VAC, DC: 50 mA
Maximum operating current 48 VAC, DC: 40 mA IS1000E-4003 3/8
32 80.5 62.5 37 12.5
AC40 (2) IC
100 VAC, DC: 20 mA IS1000E-4004 1/2 AR40, AW40
AWM40, AWD40
IS1000E-4006 3/4 VBA
Note 1)  in the model numbers indicates a thread type. No indication
is necessary for Rc; however, indicate N for NPT, and F for G.
Note 2) A pressure switch cannot be mounted on AC40-06 and VE
AW40-06.
∗ Separate interfaces are required for modular unit. VY1
∗∗ The pressure switch on AC40-06 and above and AW40-06 can
be mounted by screwing IS1000-01 into the piping adapter E500-
06-X501 or E600-06-X501 to E600-06 to 10-X501 (with top- G
face thread Rc 1/8). Products with a premounted switch are
available as a special order. Please contact SMC regarding their
availability.
PPA
How to Order AL

IS1000E 30 03
Option
Pressure switch X201 Lead wire length: 3 m
with piping X202 Regulating pressure range: 0.1 to 0.6 MPa
adapter X207 MPa/PSI Dual scale

Body size X215 Lead wire length: 3 m; Regulating pressure range: 0.1 to 0.6 MPa

20 For AC20 X250 Opposite-side mounting (Left-side mounting style)

30 For AC25, AC30 X251 Lead wire length: 3 m; Opposite-side mounting (Left-side mounting style)
Set pressure range: 0.1 to 0.6 MPa; Opposite-side mounting
40 For AC40-02 to 04 X252 (Left-side mounting style)
Lead wire length: 3 m; Regulating pressure range: 0.1 to 0.6 MPa;
Thread type X253
Opposite-side mounting (Left-side mounting style)
Nil Rc
This product is for overseas use only according to the new Measurement Law.
N NPT (The SI unit type is provided for use in Japan.)
F G
Piping adapter port size
Port Body size
Symbol
size 20 30 40
01 1/8 ● — —
02 1/4 ● ● ●
03 3/8 ● ● ●
04 1/2 — ● ●
06 3/4 — — ●

14-2-25
26

Series AC
Check Valve (K): Rc1/8, 1/4, 3/8
A check valve with intermediate air release port can be easily A
installed to prevent a back flow of lubricant when redirecting the
air flow and releasing the air on the outlet side of the regulator.

B
Check valve

Bypass port size for


E redirecting air flow
JIS Symbol

C
IN OUT

Specifications

D
Model Effective area (mm2)
AKM2000 28
(mm)
AKM3000 55
Bypass
AKM4000 111 Model port size A B C D E Applicable model
Be sure to use above check valves
AKM2000 1/8, 1/4 40 40 28 11 11 AC20, AC20A
when redirecting the air flow on the
inlet side of the lubricator. Threads for AC25, AC25A
AKM3000 1/8, 1/4 53 48 34 14 13
IN and OUT ports are not machined. AC30, AC30A
AKM4000 1/4, 3/8 70 54 42 18 15 AC40, AC40A Note)
How to Order Note) Not applicable to AC40-06.
∗ Refer to the attachment table on page 14-2-12 or 14-2-16 for standard
bypass port sizes applicable to AC.
AKM 30 00 01
Check valve
Bypass port size for
Body size redirecting air flow
20 30 40 Port Body size
Symbol
size 20 30 40
01 1/8 앬 앬 —
02 1/4 앬 앬 앬
03 3/8 — — 앬

Thread type
Nil Rc
N NPT
F G

14-2-26
27

Attachment Specifications Series AC


Pressure Switch (S)

Approx. 500
A compact integrated pressure switch can be easily installed and
facilitates the pressure detection of the line.
15 23
Pressure switch

F.R.L.

C
B
JIS Symbol
AV
AU
Center of
F.R.L. body AF
A D
Specifications (mm) AR
Fluid Air Model A B C D Applicable model
Proof pressure 1.0 MPa IS1000M-20 11 76 66 28 AC20 IR
Maximum operating pressure 0.7 MPa IS1000M-30 13 86 72 30 AC25, AC30
Set pressure range (Off) 0.1 to 0.4 MPa IS1000M-40 15 95 77 36 AC40 VEX
Differential 0.08 MPa IS1000M-50 17 99 79 44 AC40-06
Ambient and fluid temperature –5 to 60°C (With no freezing) IS1000M-60 22 92.5 68.5 53 AC50, AC55B, AC60 AMR
Note) Separate interfaces are required for modular unit.
ITV
Switch Characteristics How to Order
Contact point configuration 1a IC
Maximum contact point capacity
Operating voltage: AC, DC
2 VA(AC), 2 W(DC)
100 V or less
IS1000M 30 VBA
12 V to 24 VAC, DC : 50 mA
Pressure switch Accessory
Maximum operating current 48 VAC, DC : 40 mA X201 Lead wire length: 3 m VE
100 VAC, DC : 20 mA
Body size
Regulating pressure
20 For AC20 X202 range: 0.1 to 0.6 MPa
30 For AC25, AC30 VY1
X207 MPa/PSI dual scale
40 For AC40-02 to 04 Lead wire length: 3 m;
50 For AC40-06 X215 Regulating pressure
G
60 For AC50, AC55, AC60 range: 0.1 to 0.6 MPa
This product is for overseas use PPA
only according to the new
Measurement Law. (The SI unit
type is provided for use in Japan.)
AL
Cross Interface (C): M5 x 0.8, 1/8, 1/4, 3/8, 1/2
Center of
Pipings are possible in all 4 directions. F.R.L. body Port size
E
IN/OUT ports are not machined for threads. Please
contact SMC if threaded (machined) ports are required.
F
B
C

F E E
Cross interface

E: 4-Rc
A E
F: Without thread D
(mm)
Model Port size A B C D Applicable model
Y14-M5 M5 23 16 14 25 AC10
Y24-01 1/8
40 40 22 40 AC20
Y24-02 1/4
Y34-01 1/8
49 43 28 48 AC25, AC30
Y34-02 1/4
Y44-02 1/4
Caution on Mounting 60 48 36 54 AC40
Y44-03 3/8
• When mounting a cross interface directly on the IN side of the Y54-03 3/8
lubricator, be sure to use a Series AKM check valve between the 72 62 40 62 AC40-06
Y54-04 1/2
lubricator and cross interface.
Note) •  in the model numbers indicates a thread type. No indication is
• Factory mounting of a cross interface on the AC model is necessary for Rc; however, indicate N for NPT, and F for G.
available as a special order. • If threaded ports are required, they are available as a special order.
Please contact SMC.

14-2-27
28

Series AC
Residual Pressure Relief 3 Port Valve (V)
With the use of a 3 port valve for residual pressure release,

0
pressure left in the line can be easily exhausted.

ø1
øI
2-
3 port valve for
residual pressure release

G
H

F
E Lockable at the time of exhaust
JIS Symbol
(A) C
2
D

1 3
Specifications (P) (R)
Port size Effective area (mm2) ( ): Effective Area mm2 (Cv)
Model SUP
IN, OUT EXH IN to OUT OUT to EXH
1/8 10 (0.54) 11 (0.60)

A
VHS20 1/8
1/4 14 (0.76) 16 (0.87) IN OUT
1/4 16 (0.87) 14 (0.76)
VHS30 1/4
3/8 31 (1.68) 29 (1.57)

B
1/4 27 (1.46) 36 (1.95)
VHS40 3/8 3/8 38 (2.06) 40 (2.17)
1/2 55 (2.98) 42 (2.28) EXH
VHS40-06 3/4 1/2 77 (1.73) 49 (2.66)
3/4 82 (4.44) 50 (2.71)
VHS50 1/2 (mm)
1 125 (6.78) 53 (2.87)
∗ Paint color (Standard) Handle: Red, Body: Platinum silver Model A B C D E F G H I
∗∗ Use an air filter on the IN side for operating protection.
VHS20 59 20 40 34 — 45 33 28 45
How to Order VHS30 78 29 53 46 — 55 42 30 55
VHS40 107 39 70 63 22 58 44 36 63

VHS 30 F 03 RZ VHS40-06
VHS50
110
134
42
53
75
90
67
78
21
26
65
76
50
61
44
54
69
81
Residual pressure Caution
relief 3 port valve
1. Pleae consult with SMC when a pressure switch and T type
spacer are installed on the outlet of pressure release valve.
Body size 2. If a stop valve or a silencer is connected to the exhaust port of
Symbol Applicable model VHS20/30, the effective sectional area should be larger than
20 AC20 the figure indicated in the following table, to prevent
30 AC25/30 malfunction caused by back pressure. (This is not applicable to
40 AC40 VHS40 and VHS50)
50 AC50, AC60 Note) Model Effective area (mm2)
Note) When the valve is mounted VHS20 5
on AC60, the flow rate may 5
VHS30
decrease depending upon
the mounting position.

Thread type
Nil Rc
N NPT
Option
F G
Code Description
Port size R Flow direction: Right  Left
Body size Note)
Z Name plate in imperial units (PSI, °F)
Symbol Port size
20 30 40 50 Note) This product is for overseas use only
01 1/8 앬 — — — according to the new Measurement
Law. (The SI unit type is provided for
02 1/4 앬 앬 앬 — use in Japan.)
03 3/8 — 앬 앬 —
04 1/2 — — 앬 —
06 3/4 — — 앬 앬
10 1 — — — 앬

14-2-28
29

Spacers and Brackets Series AC


Accessory Dimensions
Spacer (X)
D
Center of
F.R.L. body
F.R.L.

C
1
X-X AV

B
RELEASE
X
2
Y200 Y400 AU
(mm)
X
Model A B C D Applicable model
AF
Seal
Y100 6 27 15 33 AC10, AC10A, AC10B
Y200 3 35.5 18.5 48 AC20 AR
Y300 4 47 26 59 AC25, AC30
Y400 5 57 31 65 AC40 A IR
Y500 5 61 33 70 AC40-06 Spacer width

Y600 6 75.5 41 86
AC50, AC55, AC60 VEX
AC50B, AC55B, AC60B

Replacement Parts AMR


Part no.
Description Material
Y100 Y200 Y300 Y400 Y500 Y600
ITV
Seal HNBR (2)
Y100P-060AS (1) Y200P-060S Y300P-060S Y400P-060S Y500P-060S Y600P-060S
Note 1) Y-100 comes with 2 O-rings.
IC
Note 2) NBR seal is used for Y100 spacer because of no direct contact with fluid.
VBA
Spacer with Bracket (Z)
VE
øG

VY1
Center of
F.R.L. body
G
C

BB (Y100T, Y200T only)


E

1
X-X PPA
EE (Y100T, Y200T only)

RELEASE

X
2
AL
E

X
G

Seal

Y200T Y400T
F J
A
H K
Spacer width
D
(mm)
Model A B BB C D E EE F G øG H J K Applicable model
Y100T 6 — 56 24.5 40.5 20 27 6.8 4.5 4.5 14 2.8 25 AC10
Y200T 3 — 67 29 53 24 33 12 5.5 5.5 19 3.2 30 AC20
Y300T 4 82 — 41 68 35 — 14 7 7 21 4 41 AC25, AC30
Y400T 5 96 — 48 81.5 40 — 18 9 9 26 4 50 AC40
Y500T 5 96 — 48 86 40 — 18 9 9 27 4.6 50 AC40-06
Y600T 6 120 — 60 112 50 — 20 11 11 31 6.4 70 AC50, AC55, AC60, AC50B, AC55B, AC60B

Replacement Parts
Part no.
Description Material
Y100T Y200T Y300T Y400T Y500T Y600T
Seal HNBR (2) Y100P-060AS (1) Y200P-060S Y300P-060S Y400P-060S Y500P-060S Y600P-060S
Note 1) Y-100T comes with 2 O-rings.
Note 2) NBR seal is used for Y100T spacer because of no direct contact with fluid.

14-2-29
30

Series AC
Mounting Position for Spacer with Bracket

Bracket
Pressure switch: S Residual pressure
T-interface: T Check valve: K relief 3 port valve: V

SUP.
SUP

A
A
IN OUT IN OUT

A
A
Bracket

L1 L2 L3 L4 L1

(mm)
Attachment K S T V KS KT KV KST
Model L1 L2 L3 L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 L4 L1 L2 L3
AC10 — — — — — 28 48 — — — — — — — — — — — — — — — —
AC20 41.5 43 43 41.5 43 41.5 61 41.5 43 43 41.5 43 57 41.5 61 43 41.5 43 43 43 41.5 61 57
AC25 55 57 57 55 57 55 76 55 57 57 55 57 74 55 76 57 55 57 57 57 55 76 74
AC30 55 57 57 55 57 55 76 55 57 57 55 57 74 55 76 57 55 57 57 57 55 76 74
AC40 72.5 75 75 72.5 75 72.5 99 72.5 75 75 72.5 75 95 72.5 99 75 72.5 75 75 75 72.5 99 95
AC40-06 — — — 77.5 80 77.5 104 77.5 80 80 — — — — — — — — — — — — —
AC50 — — — 93 96 93 124 93 96 96 — — — — — — — — — — — — —
AC55 — — — 98 96 98 124 — — — — — — — — — — — — — — — —
AC60 — — — 98 101 98 129 — — — — — — — — — — — — — — — —
Attachment KSV KTV KSTV ST SV STV TV
Model L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3
AC10 — — — — — — — — — — — — — — — — — — — — — — —
AC20 41.5 43 57 43 41.5 61 43 43 41.5 61 57 43 41.5 61 41.5 43 57 41.5 61 57 41.5 61 43
AC25 55 57 74 57 55 76 57 57 55 76 74 57 55 76 55 57 74 55 76 74 55 76 57
AC30 55 57 74 57 55 76 57 57 55 76 74 57 55 76 55 57 74 55 76 74 55 76 57
AC40 72.5 75 95 75 72.5 99 75 75 72.5 99 95 75 72.5 99 72.5 75 95 72.5 99 95 72.5 99 75
AC40-06 — — — — — — — — — — — — 77.5 104 77.5 80 102 77.5 104 102 77.5 104 80
AC50 — — — — — — — — — — — — 93 124 93 96 124 93 124 124 93 124 96
AC55 — — — — — — — — — — — — 98 124 — — — — — — — — —
AC60 — — — — — — — — — — — — 98 129 — — — — — — — — —
Attachment
K S V KS KV KSV SV
Model L1 L2 L1 L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2
AC20A 41.5 43 41.5 41.5 43 41.5 57 41.5 43 43 41.5 57 43 41.5 57
AC30A 55 57 55 55 57 55 74 55 57 57 55 74 57 55 74
AC40A 72.5 75 72.5 72.5 75 72.5 95 72.5 75 75 72.5 95 75 72.5 95
AC40A-06 — — 77.5 77.5 80 — — — — — — — — 77.5 102
Attachment
S T V SV TV
Model L1 L1 L1 L2 L1 L2 L1 L2
AC10B — 28 — — — — — —
AC20B 41.5 41.5 41.5 43 41.5 57 41.5 61
AC25B 55 55 55 57 55 74 55 76
AC30B 55 55 55 57 55 74 55 76
AC40B 72.5 72.5 72.5 75 72.5 95 72.5 99
AC40B-06 77.5 77.5 77.5 80 77.5 102 77.5 104
AC50B 93 93 93 96 93 124 93 124
AC55B 98 98 — — — — — —
AC60B 98 98 — — — — — —
Attachment
S T V SV TV
Model L1 L2 L1 L2 L1 L2 L3 L1 L2 L3 L1 L2 L3
AC20C 41.5 43 41.5 43 41.5 43 43 41.5 43 57 41.5 43 61
AC25C 55 57 55 57 55 57 57 55 57 74 55 57 76
AC30C 55 57 55 57 55 57 57 55 57 74 55 57 76
AC40C 72.5 75 72.5 75 72.5 75 75 72.5 75 95 72.5 75 99
AC40C-06 77.5 80 77.5 80 77.5 80 80 77.5 80 102 77.5 80 104
Attachment
S V SV L1: Dimensions from the end of the IN side to the center of the mounting hole for the first bracket.
Model L1 L1 L2 L1 L2 L2: Mounting hole pitch between the first and the second bracket.
AC20D 41.5 41.5 43 41.5 57 L3: Mounting hole pitch between the second and the third bracket.
AC30D 55 55 57 55 74 L4: Mounting hole pitch between the third and the fourth bracket.
AC40D 72.5 72.5 75 72.5 95 Refer to dimensions pages for dimension A from the center of the piping and the mounting hole.
AC40D-06 77.5 77.5 80 77.5 102

14-2-30
31
F.R.L. Unit Series AC20 to 60
Made to Order Specifications:
Please contact SMC for detailed dimensions, specifications, and lead times.

With Digital Pressure Switch


AC20 to 60 with a digital pressure switch (Model: ISE30---L) can be ordered. A digital pressure switch is mounted on the
connection threads for the pressure gauge of the regulator or the filter regulator.

F.R.L.
AV
AU
AF
AR
IR
Specifications VEX
Part no. -X465
Model ISE30---L AMR
Set pressure range –0.1 to 1 MPa
Pressure
Set/Display resolution 0.001 MPa ITV
switch
Power supply voltage 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (With reverse connection protection)
Current consumption 45 mA or less (70 mA or less during current output)
IC
∗ Pressure gauge port size: Rc 1/8
VBA
Applicable Model VE
Model AC20 AC25 AC30 AC40 AC40-06 AC50 AC55 AC60

1/8 1/4 1/4 1/4 3/4


VY1
Port size 3/8 3/4 1 1
1/4 3/8 3/8 1/2 1 G
PPA
How to Order Refer to the next page.
AL

14-2-31
32

Series AC
How to Order

AC 30 A F 03 D KV 12R X465 A
Switch specifications
F.R.L. unit
Symbol Output specifications
Body size A NPN output
20 25 30 40 50 55 60 B PNP output
C 1 to 5 V output
Model combination D 4 to 20 mA output
Combination With digital pressure switch
Symbol Filter Mist
Air filter Regulator Lubricator Regulator Separator (Series ISE30) (12)
Nil (1) (2) (3) — — Note 12) Digital pressure switch is not
A — — (2) (1) — mounted and is supplied
loose at the time of
B (1) (2) — — — Description shipment.
C (1) (3) — — (2) Symbol Description Applicable model
D — — — (1) (2) 1 (9) 0.02 to 0.2 MPa setting AC20 to 60
Note 1) The circled numbers indicate the 2 Metal bowl AC20 to 60
order in which the units are
assembled. 3 Lubricator with drain cock AC20 to 60
6 Nylon bowl (Including sight dome) AC20 to 60
Thread type
8 Metal bowl with level gauge AC25 to 60
Nil Rc C With bowl guard AC20
N (2) NPT J (10) Drain guide 1/4 AC25 to 60
F (3) G N Non-relieving type AC20 to 60
Note 2) Drain guide is NPT 1/4 (applicable R Flow direction: Right  Left AC20 to 60
to AC25 to 60), and the exhaust
port for auto-drain comes with ø3/8" Drain cock with barb fitting:
W AC25 to 60
One-touch fitting (applicable to ø6 x ø4 nylon tubing
AC25 to 60).
Name plate and caution plate for
Note 3) Drain guide is G 1/4 (applicable to Z (11) bowl in imperial units (PSI, °F) AC20 to 60
AC25 to 60).
Port size ∗ When more than one specification is required, indicate
Port Body size in ascending alphanumeric order.
Symbol
size 20 25 30 40 50 55 60 Note 9) The only difference from the standard
01 1/8 ● — — — — — — specifications is the adjusting spring for
the regulator. It does not restrict the
02 1/4 ● ● ● ● — — —
setting of 0.2 MPa or more.
03 3/8 — ● ● ● — — — Note 10) Without a valve function.
04 1/2 — — — ● — — — Note 11) For thread type NPT.
06 3/4 — — — ● ● — — This product is for overseas use only
10 1 — — — — ● ● ● according to the new Measurement Law.
(The SI unit type is provided for use in
Japan.)
Accessory Attachment
Symbol Description Applicable model Attachment Port size for
Symbol Description Applicable model intermediate
Nil — — mounting position air release
C With float type auto-drain (N.C.) (4) AC20 to 60 Nil None — — —
D With float type auto-drain (N.O.) (4) AC25 to 60 AF + AR + [K] + AL AC20: 1/8
AC20 to 40
K Check valve AC25: 1/4
Note 4) Applicable tubing O.D for auto drain connection should be AW + [K] + AL AC20A to 40A AC30: 1/4
AC40: 3/8
ø3/8" in case NPT thread port is chosen.
AC20: 1/8
AF + [T] + AR + AL AC20 to 60 AC25: 1/4
AC30: 1/4
T T-interface AF + [T] + AR AC20B to 60B AC40: 3/8
AC50: 3/8
AF + AFM + [T] + AR AC20C to 40C AC55: 1/2
AC60: 1/2
AF + AR + AL + [V] AC20 to 50
Note 13) Please consult with SMC for detailed AW + AL + [V] AC20A to 40A
dimensions and available attachments and Residual
V pressure relief
AF + AR + [V] AC20B to 50B —
options.
Note 14) Refer to SMC catalog CAT.ES100-42 for 3 port valve AF + AFM + AR + [V] AC20C to 40C
detailed specifications and instructions of AW + AFM + [V] AC20D to 40D
digital pressure switch. [V] + AF + ARK AC20B to 50B
Residual
V1 (8) pressure relief [V] + AF + AFM + ARK AC20C to 40C —
3 port valve
[V] + AWK+ AFM AC20D to 40D
Note 5) When more than one attachment is required, order in alphabetical order.
Note 6) Piping adapter, pressure switch with piping adapter, and cross interface need to be
ordered separately.
Note 7) The bracket position varies depending on the T-interface mounting.
Refer to the table on page 14-2-30 for standard bracket position.
Note 8) With this combination, requlators and filter requlators will be “With back flow function” type.
For safety, check that the ezhausted and is atmospheric pressure by pressure gauge.

14-2-32
33

Modular Style
Air Filter

Series AF
Air filter Model Port size Filtration Accessory F.R.L.
(µm)
Series AF
AF10 M5 x 0.8 AV
AF20 1/8, 1/4 AU
AF30 1/4, 3/8 AF
Bracket
AF40 1/4, 3/8, 1/2 5 AR
Float type auto-drain
AF40-06 3/4 IR
AF50 3/4, 1 VEX

Pages 14-2-34 to 14-2-39 AF60 1 AMR


Mist separator AFM20 1/8, 1/4
ITV
Series AFM
IC
AFM30 1/4, 3/8 Bracket
0.3 VBA
AFM40 1/4, 3/8, 1/2 Float type auto-drain
VE
Pages 14-2-40 to 14-2-42
AFM40-06 3/4 VY1
Micro mist separator
AFD20 G
Series AFD 1/8, 1/4
PPA
AFD30 1/4, 3/8 Bracket
0.01 AL
AFD40 1/4, 3/8, 1/2 Float type auto-drain

Pages 14-2-43 to 14-2-45


AFD40-06 3/4

14-2-33
34

Air Filter

Series AF10 to 60
How to Order
Option
AF 30 F 03 BD 2R Symbol Description Applicable
model
Air filter Accessory 2 Metal bowl AF10 to 60
Body size
Applicable 6 Nylon bowl AF10 to 60
10 20 30 40 50 60 Symbol Description model
8 Metal bowl with level gauge AF30 to 60
Nil — —
Thread type C With bowl guard AF20
Port size B ( 3) With bracket AF20 to 60
Metric thread (M5) J (5) Drain guide 1/4 AF30 to 60
Nil Float type (4)
Rc Symbol
Port Body size C auto-drain (N.C.) AF10 to 60 R Flow direction: Right  Left AF10 to 60
size 10 20 30 40 50 60
N (1) NPT Drain cock with barb fitting:
Float type (4) W
M5 M5 앬 — — — — — D AF30 to 60
F (2) G auto-drain (N.O.) AF30 to 60 ø6 x ø4 nylon tubing
01 1/8 — 앬 — — — —
Note 1) Drain guide is NPT 1/4 Note 3) Bracket is not assembled Name plate and caution plate for
02 1/4 — 앬 앬 앬 — — Z (6) bowl in imperial units (PSI, °F) AF10 to 60
(applicable to AF30 to and is supplied loose at the
60), and the exhaust 03 3/8 — — 앬 앬 — — time of shipment. ∗ When more than one specification is
port for auto-drain 04 1/2 — — — 앬 — — Note 4) Applicable tubing O.D for required, indicate in ascending
comes with ø3/8" One- 06 3/4 — — — 앬 앬 — auto-drain connection alphanumeric order.
touch fitting (applicable should be ø3/8" in case Note 5) Without a valve function.
10 1 — — — — 앬 앬
to AF30 to 60). NPT thread port is chosen. Note 6) This product is for overseas use only
Note 2) Drain guide is G 1/4 according to the new Measurement
(applicable to AF30 to Law. (The SI unit type is provided for
60). use in Japan.)

: Combination available : Combination not available


Accessory/Optional Specifications Combinations : Varies depending on the model : Available only with NPT thread
Symbol

Combination Accessory Optional specifications Applicable filter


Accessory/Optional specifications B C D 2 6 8 C J R W Z AF10 AF20 AF30 to 60
Optional specifications Accessory

AF10 With bracket B


Float type auto-drain (N.C.) C
AF20 Float type auto-drain (N.O.) D
Metal bowl -2
Nylon bowl -6
Metal bowl with level gauge -8
With bowl guard -C
AF30 Drain guide 1/4 -J
Flow direction: Right  Left -R
Drain cock with barb fitting: ø6 x ø4 nylon tubing -W
AF40 Name plate and caution plate for bowl in
imperial units (PSI, °F) -Z
JIS Symbol
Standard Specifications
Model AF10 AF20 AF30 AF40 AF40-06 AF50 AF60

Port size M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1

Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating 5 µm
Bowl material Polycarbonate
Bowl guard — Option Standard
Drain capacity (cm3) 2.5 8 25 45 45 45 45
Weight (kg) 0.06 0.18 0.22 0.45 0.49 0.99 1.05
Accessory Part No.
With auto-drain Applicable model
AF10 AF20 AF30 AF40 AF40-06 AF50 AF60
Accessory
JIS Symbol
Bracket assembly (1) — AF20P-050AS AF30P-050AS AF40P-050AS AF40P-070AS AF50P-050AS AF50P-050AS
Float type (2) N.O. — — AD38 AD38N(3) AD48 AD48N(3) AD48 AD48N(3) AD48 AD48N(3) AD48 AD48N(3)
auto-drain N.C. AD17 AD27 AD37 AD37N(3) AD47 AD47N(3) AD47 AD47N(3) AD47 AD47N(3) AD47 AD47N(3)
Note 1) Assembly includes a bracket and 2 mounting screws.
Note 2) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.1 MPa (AD17/27) and 0.15 MPa (AD37/47).
Note 3) When “N” is specified in the end of part number of auto-drain, applicable tubing O.D should be ø3/8".
P. 14-2-39

14-2-34
35

Air Filter Series AF10 to 60


Flow Characteristics (Representative values)
AF10
0.10
M5 AF40-06
0.10
Rc 3/4 Precautions
Be sure to read before handling.
Refer to pages 14-21-3 to 14-21-4 for

a
0.08 0.08

a
Pressure drop (MPa)

Pressure drop (MPa)


MP

= 0 Pa
MP
a
Safety Instructions and Common

MP
MPa

M
0.7

.7
P1 a Precautions.

.5
.3
0.06 0.06
MP
Pa

=0
=0
0.1
a
M

MP

P1
0.5

P1
P1
Maintenance

P1 =
0.1

0.04
=
.3

0.04
F.R.L.
P1
=0
P1 =

Warning
P1

0.02 0.02
1. Replace the element every 2 years or when AV
the pressure drop becomes 0.1 MPa,
00 00
50 100 150 200 2000 4000 6000 whichever comes first, to prevent damage AU
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) to the element.
AF
AF20 Rc 1/4 AF50 Rc 1
0.10 0.10
AR
Pa

= 0 MPa
M

a
a

0.08 0.08
IR
MP
MP
Pressure drop (MPa)

Pressure drop (MPa)


Pa

.7
=0

a
5
.7
.3 M
a

.5

MP

.
MP

=0
=0

VEX
P1

0.06 0.06
=0

.3
a

P1
P1
0.1

MP
P1

=0
P1

AMR
P1 =

0.1

0.04 0.04
P1
P1 =

0.02 0.02
ITV
0
0 500 1000 1500
0
0 5000 10000 15000 IC
Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
VBA
AF30 Rc 3/8 AF60 Rc 1
0.10 0.10 VE
a
MP
Pa

VY1
Pa

.7
.5 M

0.08 0.08
a
Pressure drop (MPa)

Pressure drop (MPa)

a
=0
MP
0.1 M

MP
= 0 Pa
=0
P1

M
.7
0.3

G
Pa

.5

0.06 0.06
P1
P1 =

=0
a
.3 M
P1 =

MP

P1
P1

PPA
=0

0.04 0.04
0.1
P1
P1 =

0.02 0.02 AL
0 0
0 1000 2000 3000 4000 0 5000 10000 15000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

AF40 Rc 1/2
0.10
a
MP
P1 MPa
Pa

.7

0.08
Pressure drop (MPa)

=0
.3 M

.5
Pa

=0
0.1 M

=0

0.06
P1
P1
P1 =

0.04

0.02

0
0 2000 4000 6000
Flow rate (l/min (ANR))

14-2-35
36

Series AF10 to 60
Working Principle: Float Type Auto Drain
N.O. type: AD38/48 N.C. type: AD37/47 Compact auto-drain
N.C. type: AD17/27

q Bowl q Bowl
r Valve r Valve
e Lever e Lever q Bowl
w Float w Float
w Float
t Valve seat t Valve seat
e Lever
i Chamber i Chamber
y Spring u Piston r Valve
u Piston y Spring t Valve seat
o Housing o Housing y Knob
!0 Seal !0 Seal
!1 Drain cock !1 Drain cock Drain

Drain Drain

• When the pressure inside the bowl • When the pressure inside the bowl is • When the pressure inside the bowl
is released: released: is released:
When pressure is released from the bowl Even when pressure inside the bowl q, is Even when pressure inside the bowl q, is
q, piston u is lowered by spring y. released, spring y keeps piston u in its released, the weight of the float w causes
upward position. valve r, which is connected to lever e, to
The sealing action of seal !0 is interrupted,
and the outside air flows inside the bowl This keeps the seal created by the seal !0, seal valve seat t. As a result, the inside of
q, through housing hole o and drain in place, thus shutting the outside air from the bowl q, is shut off from the outside air.
cock !1. inside the bowl q.
Therefore, even if there is an accumulation
Therefore, if there is an accumulation of Therefore, even if there should be some of condensate in the bowl q, it will not drain
condensate in the bowl q, it will drain out condensate accumulation inside the bowl q, out.
through the drain cock. it will not drain out.
• When pressure is applied inside the
• When pressure is applied inside • When pressure is applied inside the
bowl: bowl:
the bowl: Even when pressure is applied inside the
When the pressure exceeds 0.1 MPa, the Even when pressure is applied inside the
bowl q, the combined force of spring y and bowl q, the weight of the float w, and the
force of piston u surpasses the force of differential pressure that is applied to valve
spring y, and the piston goes up. the pressure inside the bowl q, keeps
piston u in its upward position. r cause valve r to seal valve seat t, and
This pushes seal !0 up so that the it
creates a seal and the inside of the bowl This maintains the seal created by the seal the outside air is shut off from the inside of
q, is shut off from the outside air. !0, in place, thus shutting the outside air the bowl q.
If there is no accumulation of condensate from inside the bowl q. • When the drain is accumulated in
in the bowl q, at this time float w will be If there is no accumulation of condensate in the bowl:
pulled down by its own weight, causing the bowl q, at this time float w will be
valve r, which is connected to lever e, to Float w rises due to its own buoyancy and
pulled down by its own weight, causing valve
seal valve seat t. the seal at valve seat t is interrupted.
r, which is connected to lever e, to seal
valve seat t. The condensate inside the bowl q drains
• When there is an accumulation of out through the knob, y.
condensate in the bowl: • When there is an accumulation of
Turning knob y manually counterclockwise
Float w rises due to its own buoyancy and condensate in the bowl: lowers it and causes the sealing action of
pushes open the seal created by the valve Float w rises due to its own buoyancy and valve seat t to be interrupted, thus allowing
seat, t. pushes open the seal created by the valve the condensate to drain out.
This allows the pressure inside the bowl seat t. Pressure passes from the bowl to
q, to enter the chamber i. The result is chamber i.
that the combined pressure inside The result is that the pressure inside
chamber i and the force of the spring y, chamber i surpasses the force of the
lower the piston u. spring y, and pushes piston u
This causes the sealing action of seal !0 to downwards.
be interrupted, and the accumulated This causes the sealing action of seal !0 to
condensate in the bowl q, drains out be interrupted and the accumulated
through the drain cock !1. condensate in the bowl q, drains out
Turning drain cock !1 manually through the drain cock !1.
counterclockwise lowers piston u, which Turning drain cock !1 manually
pushes open the seal created by seal !0, counterclockwise lowers piston u, which
thus allowing the condensate to drain out. pushes open the seal created by seal !0,
thus allowing the condensate to drain out.

14-2-36
37

Air Filter Series AF10 to 60


Construction
AF10/20 AF30/40 AF50/60

IN OUT IN OUT IN OUT

q q F.R.L.
r r q
AV
w w
e e y AU
t t AF
w
AR
r
IR
e
Drain VEX
t AMR
Drain ITV
IC
VBA
VE
VY1
G
PPA
Drain AL
Component Parts
Material
No. Description Color
AF10/20 AF30/40/40-06 AF50/60
q Body Zinc die-casted Aluminum die-casted Platinum silver
y Housing — Aluminum die-casted Platinum silver

Air Filter Replacement Parts


Part no.
No. Description Material
AF10 AF20 AF30 AF40 AF40-06 AF50 AF60
w Filter element Non-woven fabric AF10P-060S AF20P-060S AF30P-060S AF40P-060S AF40P-060S AF50P-060S AF60P-060S
e Baffle PBT AF10P-040S (1) AF20P-040S AF30P-040S AF40P-040S AF40P-040S AF50P-040S AF60P-040S
r Bowl O-ring NBR C1SFP-260S C2SFP-260S C3SFP-260S C4SFP-260S C4SFP-260S C4SFP-260S C4SFP-260S
t Bowl assembly (2) PC C1SF C2SF C3SF (3) C4SF (3) C4SF (3) C4SF (3) C4SF (3)
Note 1) The material of the baffle for AF10 (AF10P-040S) only is POM.
Note 2) Please contact SMC regarding the bowl assembly supply for PSI and °F unit specifications.
Note 3) Bowl assembly for AF30 to 60 models comes with a bowl guard (steel band material).

14-2-37
38

Series AF10 to 60
Dimensions
L
AF10/20 L Bracket
AF50/60 A Bracket
(Option)
D
(Option) D G F
G F K M

J
K M

E
E

H
IN OUT

C
H IN OUT
C

OUT
B Port size OUT

Port size

o s
AF10: 25
AF20: 40

Drain

B
A P
Min. clearance
for maintenance
AF30/40/40-06
L
A Bracket
(Option) D
G F
K M
J

Drain Min. clearance


H

20
C

IN OUT for maintenance


OUT
Port size
B
AF30: 50
AF40: 75

Min. clearance
Drain P
for maintenance

Applicable model AF10, AF20 AF30, AF40, AF40-06, AF50, AF60


With auto-drain (N.C.) Metal bowl With auto-drain (N.O./N.C.) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting

Optional
B

B
B

B
B

specifications
B

N.O.: Black
B

O S N.C.: Gray O
S
M5 x 0.8 ø10 One-touch 1/4 Barb fitting
fitting Width across flats 17 Applicable tubing: T0604

(mm)
Accessory specifications
Standard specifications With
Model Port size Bracket mounting size auto-drain
A B C D P E F G H J K L M B
AF10 M5 x 0.8 25 67 7 25 28 — — — — — — — — 85
AF20 1/8, 1/4 40 97 10 40 — 18 30 27 22 5.4 8.4 40 2.3 115
AF30 1/4, 3/8 53 129 14 53 57 16 41 40 23 6.5 8 53 2.3 170
AF40 1/4, 3/8, 1/2 70 165 18 70 73 17 50 54 26 8.5 10.5 70 2.3 204
AF40-06 3/4 75 169 20 70 73 14 50 54 25 8.5 10.5 70 2.3 208
AF50 3/4, 1 90 245 24 90 — 23 70 66 35 11 13 90 3.2 284
AF60 1 95 258 24 95 — 23 70 66 35 11 13 90 3.2 297

Optional specifications
Model With drain guide With barb fitting Metal bowl Metal bowl with level gauge
B B B B
AF10 — — 66 —
AF20 — — 97 —
AF30 136 137 142 162
AF40 172 173 178 198
AF40-06 176 177 182 202
AF50 252 253 258 278
AF60 265 266 271 291

14-2-38
39
Air Filter Series AF20 to 60
Made to Order Specifications:
Please contact SMC for detailed dimensions, specifications, and lead times.

1. Special Temperature Environment 2. High Pressure


Special materials are used in the manufacturing of seals and Strong materials are used in the manufacturing of air filters
resin parts to allow them to withstand various temperature intended for high pressure operation.
conditions in cold or tropical (hot) climates.
Specifications Specifications F.R.L.
Part no. -X430 -X440 Part no. -X425
AV
Environment Low temperature High temperature Proof pressure 3.0 MPa
Ambient temperature –30 to 60°C –5 to 80°C Maximum operating pressure 2.0 MPa AU
Fluid temperature –5 to 60°C (With no freezing) Ambient and fluid temperature –5 to 60°C (With no freezing)

Material
Rubber parts Special NBR FPM AF
Main parts Metal (Aluminum die-casted)
AR
Applicable Model Applicable Model
Model AF30 AF40 AF40-06 AF50 AF60 Model AF20 AF30 AF40 AF40-06 AF50 AF60 IR
1/4 1/4 3/4 1/8 1/4 1/4 3/4
Port size Port sizes
3/8
3/8 3/4
1
1
1/4 3/8
3/8 3/4
1
1 VEX
1/2 1/2

AMR
How to Order How to Order ITV
AF 30 F 03 B 2 R X430 AF 30 F 03 B 2 R X425 IC
Air filter For high/low Air filter
temperature For high VBA
Body size Body size pressure
X430 Low temperature Optional
30 40 50 60 20 30 40 50 60
X440 High temperature Symbol Description Applicable model VE
Thread type Option Thread type J (5) Drain guide 1/4 AF30 to 60
Nil Rc Symbol Description Applicable model
AF30 to 60
Nil Rc R
Flow direction:
Right  Left
AF20 to 60 VY1
N (2) NPT J (5) Drain guide 1/4 N (1) NPT Name plate and
F (3) G Flow direction:
Note 1) Drain guide is NPT
R Rightt  Left
AF30 to 60 F (2) G Z (6) caution plate for
bowl in imperial
AF20 to 60 G
Name plate and Note 1) Drain guide is NPT units (PSI, °F)
1/4 (applicable to caution plate for AF30 to 60 1/4 (applicable to
AC30 to 60) Z (6)
bowl in imperial
∗ When more than one PPA
AF30 to 60)
Note 2) Drain guide is G 1/4 units (PSI, °F) specification is required,
Note 2) Drain guide is G 1/4
(applicable to AF30 indicate in ascending
∗ When more than one (applicable to AF30 to
to 60). specification is required, 60).
alphanumeric order. AL
Note 5) Without a valve function.
indicate in ascending
Note 6) For thread type NPT.
alphanumeric order.
This product is for overseas
Note 5) Without a valve function.
use only according to the new
Note 6) For thread type NPT.
Measurement Law. (The SI
This product is for overseas
unit type is provided for use in
use only according to the
Japan.)
new Measurement Law.
Port size (The SI unit type is provided
Port size
Port Body size for use in Japan.) Port Body size
Symbol
size 30 40 50 60
Symbol
size 20 30 40 50 60
Bowl
02 1/4   — — Bowl 01 1/8  — — — — Symbol Description Applicable model
03 3/8   — — Symbol Description Applicable model 02 1/4    — — 2 (4) Metal bowl AF20 to 60
04 1/2   — — 2 (4) Metal bowl AF30 to 60 03 3/8 —   — — Metal bowl
AF30 to 60
8 (3)
06 3/4 —   — Note 4) Only metal bowl available. 04 1/2 — —  — — with level gauge
10 1 — —   06 3/4 — —   — Note 4) Only metal bowl or metal bowl
Option 10 1 — — —   with level gauge available.
Symbol Description Applicable model
Nil — —
Option
Symbol Description Applicable model
B (3) With bracket AF30 to 60
Nil — —
Note 3) Bracket is not assembled and
is supplied loose at the time B (3) With bracket AF20 to 60
of shipment. Note 3) Bracket is not assembled and is
supplied loose at the time of
shipment.

Note) Please contact SMC regarding the detailed dimensions and optional availability.

14-2-39
40

Mist Separator

Series AFM20/30/40
How to Order
Option
AFM 30 F 03 BD 2R Symbol Description Applicable model
Mist separator Accessory 2 Metal bowl AFM20 to 40
Body size Symbol Description Applicable model 6 Nylon bowl AFM20 to 40
20 30 40 Port size Nil — — 8 Metal bowl with level gauge AFM30/40
(3)
Port Body size B With bracket AFM20 to 40 C With bowl guard AFM20
Thread type Symbol
size 20 30 40
Float type (4) J (5) Drain guide 1/4 AFM30/40
Nil Rc 1/8  — —
01 C auto-drain (N.C.) AFM20 to 40 R Flow direction: Right  Left AFM20 to 40
N (1) NPT 02 1/4   
F (2) G 03 3/8 —   Float type (4) W
Drain cock with barb fitting:
AFM30/40
D AFM30/40 ø6 x ø4 nylon tubing
04 1/2 — —  auto-drain (N.O.)
Note 1) Drain guide is NPT 1/4
(applicable to AFM30
06 3/4 — —  Note 4) Applicable tubing O.D for auto- Name plate and caution plate
Z (6) for bowl in imperial units (PSI, °F) AFM20 to 40
and 40), and the exhaust Note 3) Bracket is not drain connection should be
port for auto-drain assembled and ø3/8" in case NPT thread port is ∗ When more than one specification is required,
comes with ø3/8" One- is supplied loose chosen. indicate in ascending alphanumeric order.
touch fitting (applicable at the time of Note 5) Without a valve function.
to AFM30 and 40). shipment. Note 6) For NPT thread type. This product is for
overseas use only according to the new
Note 2) Drain guide is G 1/4
Measurement Law. (The SI unit type is
(applicable to AFM30
provided for use in Japan.)
and 40).
: Combination available : Combination not available
Accessory/Optional Specifications Combinations : Varies depending on the model : Available only with NPT thread
Applicable mist separator
Symbol

Combination Accessory Optional specifications


AFM20 AFM30 to 40
Accessory/Optional specifications B C D 2 6 8 C J R W Z
Optional specifications Accessory

With bracket B
Float type auto-drain (N.C.) C
Float type auto-drain (N.O.) D
Metal bowl -2
Nylon bowl -6
Metal bowl with level gauge -8
With bowl guard -C
Drain guide 1/4 -J
Flow direction: Right  Left -R
Drain cock with barb fitting: ø6 x ø4 nylon tubing -W
Name plate and caution plate for bowl in
imperial units (PSI, °F) -Z

Standard Specifications
Model AFM20 AFM30 AFM40 AFM40-06
1/4
1/8 1/4
Port size 3/8 3/4
1/4 3/8
1/2
Fluid Air
Proof pressure 1.5 MPa
AFM20 Maximum operating pressure 1.0 MPa
Minimum operating pressure 0.05 MPa
Ambient and fluid temperature –5 to 60°C (With no freezing)
Rated flow (l/min (ANR)) (1) 200 450 1100 1100
Nominal filtration rating 0.3 µm (95% filtered particle size)
Outlet side oil mist concentration Maximum 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2)
Bowl material Polycarbonate
Bowl guard Option Standard
AFM30
Drain capacity (cm3) 8 25 45 45
Weight (kg) 0.18 0.22 0.44 0.49
Note 1) When the inlet pressure is 0.7 MPa. Flow rate varies depending on the inlet pressure.
Note 2) When the compressor oil mist discharge concentration is 30 mgf/m3 (ANR).

Accessory Part No.


AFM40 Applicable model
AFM20 AFM30 AFM40 AFM40-06
Accessory
JIS Symbol Bracket assembly (1) AF20P-050AS AF30P-050AS AF40P-050AS AF40P-070AS
Float type (2) N.O. — AD38 AD38N(3) AD48 AD48N(3) AD48 AD48N(3)
auto-drain N.C. AD27 AD37 AD37N(3) AD47 AD47N(3) AD47 AD47N(3)
Note 1) Assembly includes a bracket and 2 mounting screws.
Note 2) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.1 MPa (AD17/27) and 0.15 MPa (AD37/47).
Note 3) When “N” is specified in the end of part number of auto-drain, applicable tubeing O.D should be ø3/8".

14-2-40
41

Mist Separator Series AFM20/30/40


: When saturated with oil
Flow Characteristics (Representative values) : Initial state

AFM20 AFM30 AFM40


Pressure drop (MPa)

Pressure drop (MPa)


Pressure drop (MPa)
F.R.L.
AV
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) AU
AF
Construction
AFM20 Precautions AR
IN OUT Float type auto-drain (N.C.)
Be sure to read before handling. IR
q Refer to pages 14-21-3 to 14-21-4
for Safety Instructions and VEX
e Common Precautions.
w AMR
Air Supply
r
ITV
Caution
1. Install an air filter (Series AF) as a IC
preliminary filter on the inlet side of the
mist separator to prevent premature
Drain clogging. VBA
M5 x 0.8 2. Do not install on the inlet side of the
AFM30/40 dryer as this can cause premature VE
clogging of the element.
IN OUT Float type auto-drain
N.C. N.O. Maintenance VY1
q
e
Warning G
1. Replace the element every 2 years or
w when the pressure drop becomes 0.1 PPA
MPa, whichever comes first, to prevent
r damage to the element.
AL
Design
Caution
1. Design the system so that the mist
separator is installed in a pulsation-free
location. The difference between
internal and external pressure inside
Drain the element should be kept within 0.1
MPa, as exceeding this value could
cause damage.

ø10 One-touch fitting ø10 One-touch fitting Selection


Component Parts Caution
Material 1. Do not allow air flow that exceeds the
No. Description Note
AFM20 AFM30, AFM40, AFM40-06 rated flow. If the air flow is allowed
q Body Zinc die-casted Aluminum die-casted Platinum silver outside the range of the rated flow even
momentarily, drainage and lubricant
Replacement Parts may splash at the outlet side or cause
damage to the component.
Part no.
No. Description Material 2. Do not use in a low pressure
AFM20 AFM30 AFM40 AFM40-06 application (such as a blower). F.R.L.
w Element assembly — AFM20P-060AS AFM30P-060AS AFM40P-060AS AFM40P-060AS unit has its own minimum operating
e Bowl O-ring NBR C2SFP-260S C3SFP-260S C4SFP-260S C4SFP-260S pressure depending on the equipment
and is designed specifically to function
r Bowl assembly (1) PC C2SF C3SF (2) C4SF (2) C4SF (2) with compressed air. If used below the
Note 1) Including O-Ring. Please contact SMC regarding the bowl assembly supply for PSI and °F unit specifications. minimum operating pressure, a loss of
Note 2) Bowl assembly for AFM30 to AFM40-06 includes a bowl guard (steel band material). performance and malfunction can
occur. Please contact SMC if an
application under such conditions
cannot be avoided.
14-2-41
42

Series AFM20/30/40
Dimensions
AFM20 Bracket
L (Option) D
G
F
K M

E
H
IN OUT

C
OUT
Port size

B
o s

Min. clearance
Drain

45
for maintenance
A

L
AFM30/40/40-06 A Bracket
D
(Option)
G F
K M
J

E
H

IN OUT
C

OUT

Port size
B

Min. clearance
AFM30: 50
AFM40: 75

Drain for maintenance


P

Applicable model AFM20 AFM30, AFM40, AFM40-06


With auto-drain With auto-drain Metal bowl with Drain cock with
(N.C.) Metal bowl (N.O./N.C.) Metal bowl level gauge With drain guide barb fitting

Optional
B

B
specifications
B
B

N.O.: Black
B

O S N.C.: Gray O
S
M5 x 0.8 ø10 1/4 Barb fitting
One-touch Width across Applicable tubing:
fitting flats 17 T0604

(mm)
Accessory specifications
Standard specifications
Model Port size With bracket With auto-drain
A B C D P E F G H J K L M B
AFM20 1/8, 1/4 40 97 10 40 — 18 30 27 22 5.4 8.4 40 2.3 115
AFM30 1/4, 3/8 53 129 14 53 57 16 41 40 23 6.5 8 53 2.3 170
AFM40 1/4, 3/8, 1/2 70 165 18 70 73 17 50 54 26 8.5 10.5 70 2.3 204
AFM40-06 3/4 75 169 20 70 73 14 50 54 25 8.5 10.5 70 2.3 208

Optional specifications
Model With drain guide With barb fitting Metal bowl Metal bowl with level gauge
B B B B
AFM20 — — 97 —
AFM30 136 137 142 162
AFM40 172 173 178 198
AFM40-06 176 177 182 202

14-2-42
43

Micro Mist Separator

Series AFD20/30/40
How to Order

AFD 30 F 03 BD 2R Option
Symbol Description Applicable model
Micro mist
separator Accessory 2 Metal bowl AFD20 to 40
Port size
Body size Port Body size
Symbol Description Applicable model 6 Nylon bowl AFD20 to 40 F.R.L.
Symbol Nil — — 8 Metal bowl with level gauge AFD30/40
size 20 30 40
20 30 40 Thread type 01 1/8  — — B (3) With bracket AFD20 to 40 C With bowl guard AFD20 AV
02 1/4    C Float type (4) AFD20 to 40
Nil Rc auto-drain (N.C.) J (5) Drain guide 1/4 AFD30/40
03 3/8 —  
N (1) NPT
04 1/2 — —  D Float type (4) AFD30/40
R Flow direction: Right  Left AFD20 to 40 AU
auto-drain (N.O.) Drain cock with barb fitting:
F (2) G 06 3/4 — —  W
Note 3) Bracket is not assembled and is ø6 x ø4 nylon tubing AFD30/40
Note 1) Drain guide is NPT 1/4 (applicable to AFD30 and
supplied loose at the time of shipment.
Note 4) Applicable tubing O.D for auto-drain Name plate and caution plate
AF
40), and the exhaust port for auto drain comes with connection should be ø3/8" in case Z (6) for bowl in imperial units AFD20 to 40
NPT thread port is chosen. (PSI, °F)
ø3/8" One-touch fitting (applicable to AFD30 and
40). ∗ When more than one specification is required, indicate in ascending alphanumerical order.
AR
Note 5) Without a valve function. Note 6) For NPT thread type.
Note 2) Drain guide is G 1/4 (applicable to AFD30 and 40).
: Combination available : Combination not available IR
Accessory/Optional Specifications Combinations : Varies depending on the model : Available only with NPT thread
Applicable micro mist separator VEX
Symbol

Combination Accessory Optional specifications


AFD20 AFD30 to 40
Accessory/Optional specifications B C D 2 6 8 C J R W Z AMR
Optional specifications Accessory

With bracket B
Float type auto-drain (N.C.) C ITV
Float type auto-drain (N.O.) D
Metal bowl -2 IC
Nylon bowl -6
Metal bowl with level gauge -8 VBA
With bowl guard -C
Drain guide 1/4 -J VE
Flow direction: Right  Left -R
Drain cock with barb fitting: ø6 x ø4 nylon tubing -W VY1
Name plate and caution plate for bowl in imperial units (PSI, °F) -Z
G
Standard Specifications
Model AFD20 AFD30 AFD40 AFD40-06 PPA
1/4
1/8 1/4
Port size
1/4 3/8
3/8 3/4 AL
1/2
Fluid Air
Proof pressure 1.5 MPa
AFD20 Maximum operating pressure 1.0 MPa
Minimum operating pressure 0.05 MPa
Ambient and fluid temperature –5 to 60°C (With no freezing)
Rated flow (l/min (ANR)) (1) 120 240 600 600
Nominal filtration rating 0.01 µm (95% filtered particle size)
Outlet side oil mist concentration Max. 0.1 mg/m3 (ANR) (Before saturated with oil: 0.01 mg/m3 (ANR) or less, approx. 0.008 ppm) (2)
AFD30 Bowl material Polycarbonate
Bowl guard Option Standard
Drain capacity (cm3) 8 25 45 45
Weight (kg) 0.18 0.22 0.44 0.49
Note 1) When the inlet pressure is 0.7 MPa. The flow rate varies depending on the inlet pressure.
Note 2) When the compressor oil mist discharge concentration is 30 mg/m3 (ANR).

Accessory Part No.


Applicable model
AFD40 AFD20 AFD30 AFD40 AFD40-06
Accessory
JIS Symbol Bracket assembly (1) AF20P-050AS AF30P-050AS AF40P-050AS AF40P-070AS
N.O. — AD38 AD38N(3) AD48 AD48N(3) AD48 AD48N(3)
Float type auto-drain (2)
N.C. AD27 AD37 AD37N(3) AD47 AD47N(3) AD47 AD47N(3)
Note 1) Assembly includes a bracket and 2 mounting screws.
Note 2) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.1 MPa (AD27) and 0.15 MPa (AD37/47).
Note 3) When “N” is specified in the end of part number of auto-drain, applicable tubing O.D should be ø3/8".

14-2-43
44

Series AFD20/30/40
: When saturated with oil
Flow Characteristics (Representative values) : Initial state

AFD20 AFD30 AFD40

Pressure drop (MPa)

Pressure drop (MPa)


Pressure drop (MPa)

Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

Construction
AFD20 Precautions
Float type auto drain (N.C.)
IN OUT Be sure to read before handling.
Refer to pages 14-21-3 to 14-21-4 for
q Safety Instructions and Common
Precautions.
r
w Air Supply
e Caution
1. Install a mist separator (Series AFM) as a
preliminary filter on the inlet side of the micro
mist separator to prevent premature clogging.
2. Do not install on the inlet side of the dryer as
Drain M5 x 0.8 this can cause premature clogging of the
element.
AFD30/40
Maintenance
Float type auto-drain
IN OUT N.C. N.O. Warning
q 1. Replace the element every 2 years or when the
pressure drops becomes 0.1 MPa, whichever
r comes first, to prevent damage to the element.
w Design
e
Caution
1. Design the system so that the mist separator is
installed in a pulsation-free location. The
difference between internal and external
pressure inside the element should be kept
within 0.1 MPa, as exceeding this value could
cause damage.
Drain Selection

ø10 One-touch fitting ø10 One-touch fitting


Caution
Component Parts 1. Do not allow air flow that exceeds the rated
Material
flow. If the air flow is allowed outside the range
No. Description Note of the rated flow even momentarily, drainage
AFD20 AFD30, AFD40, AFD40-06 and lubricant may splash at the outlet side or
q Body Zinc die-casted Aluminum die-casted Platinum silver cause damage to the component.
Replacement Parts 2. Do not use in a low pressure application (such
Part no. as a blower). F.R.L. unit has its own minimum
No. Description Material operating pressure depending on the
AFD20 AFD30 AFD40 AFD40-06
equipment and is designed specifically to
w Element assembly AFD20P-060AS AFD30P-060AS AFD40P-060AS AFD40P-060AS function with compressed air. If used below the
e Bowl assembly (1) PC C2SF C3SF (2) C4SF (2) C4SF (2) minimum operating pressure, a loss of
r Bowl O-ring NBR C2SFP-260S C3SFP-260S C4SFP-260S C4SFP-260S performance and malfunction can occur.
Note 1) Including O-ring. Please contact SMC regarding the bowl assembly supply for Please contact SMC if an application under
PSI and °F unit specifications. such conditions cannot be avoided.
Note 2) Bowl assembly for AFD30 to AFD40-06 includes a bowl guard (steel band material).

14-2-44
45

Micro Mist Separator Series AFD20/30/40


Dimensions
AFD20 Bracket
L (Option) D
G F
K
M

E
H
IN OUT

C
OUT

Port size F.R.L.

B
AV
o s

Min. clearance
AU
Drain

45
for maintenance
A AF
AFD30/40/40-06 L
Bracket
AR
A (Option) D
G
K
F IR
M
J

VEX
E

IN OUT
AMR
C
H

OUT

Port size
ITV
B

IC
VBA
Min. clearance P
AFD30: 50
AFD40: 75

Drain for maintenance VE


VY1
G
Applicable model AFD20 AFD30, AFD40, AFD40-06
With compact With auto-drain Metal bowl with Drain cock with
PPA
auto-drain (N.C.) Metal bowl (N.O./N.C.) Metal bowl level gauge With drain guide barb fitting
AL
Optional
B

specifications B
B

B
B

N.O.: Black
B
B

O S N.C.: Gray O

M5 x 0.8 ø10
S
1/4 Barb fitting
One-touch Width across Applicable tubing:
fitting flats 17 T0604

(mm)
Accessory specifications
Standard specifications
Model Port size With bracket With auto-drain
A B C D P E F G H J K L M B
AFD20 1/8, 1/4 40 97 10 40 — 18 30 27 22 5.4 8.4 40 2.3 115
AFD30 1/4, 3/8 53 129 14 53 57 16 41 40 23 6.5 8 53 2.3 170
AFD40 1/4, 3/8, 1/2 70 165 18 70 73 17 50 54 26 8.5 10.5 70 2.3 204
AFD40-06 3/4 75 169 20 70 73 14 50 54 25 8.5 10.5 70 2.3 208

Optional specifications
Model With drain guide With barb fitting Metal bowl Metal bowl with level gauge
B B B B
AFD20 — — 97 —
AFD30 136 137 142 162
AFD40 172 173 178 198
AFD40-06 176 177 182 202

14-2-45
46

Modular Style
Regulator
Series AR
Regulator Model Port size Accessory
Series AR
AR10 M5 x 0.8

AR20 1/8, 1/4

AR25 1/4, 3/8

AR30 1/4, 3/8

AR40 1/4, 3/8, 1/2

AR40-06 3/4 Bracket


Square
AR50 3/4, 1 embedded type
pressure gauge
Pages 14-2-47 to 14-2-53 AR60 1 (Except AR10)
Round pressure
Regulator with back flow mechanism AR20K 1/8, 1/4 gauge
Series ARK
Panel mount
AR25K 1/4, 3/8

AR30K 1/4, 3/8

AR40K 1/4, 3/8, 1/2

AR40K-06 3/4

AR50K 3/4, 1

Pages 14-2-54 to 14-2-59 AR60K 1

14-2-46
47

Regulator

Series AR10 How to Order


to 60
AR 30 F 03 BE 1N
Option
Regulator Symbol Description Applicable model
1 (2) 0.02 to 0.2 MPa setting AR10 to 60
Body size N Non-relieving AR10 to 60
R Flow direction: Right  Left AR10 to 60
10 20 25 30 40 50 60 Y Upward handle AR10 to 60 F.R.L.
AR20 Thread type Z (3) Name plate and pressure gauge in imperial units (PSI, °F)
AR10 to 60

Metric thread (M5)


∗ When more than one specification is required, indicate in ascending
alphanumeric order.
AV
Nil
Rc Note 1) This product is for overseas use only according to the new
N NPT Measurement Law. (The SI unit type is provided for use in AU
F G Japan.)
Port size Note 2) The only difference from the standard specifications is the
Port Body size adjusting spring for the regulator. It does not restrict the setting AF
Symbol
size 10 20 25 30 40 50 60 Accessory of 0.2 MPa or more.
M5 M5  — — — — — — Symbol Description Applicable model AR
01 1/8 —  — — — — — Nil — —
02 1/4 —     — —
03 3/8 — —    — —
B With bracket AR10 to 60 IR
04 1/2 — — — —  — —
E With square embedded type pressure gauge (With limit indicator) AR20 to 60
With round pressure gauge (Without limit indicator) AR10
06 3/4 — — — —   — G With round pressure gauge (With limit indicator) AR20 to 60
VEX
AR40 10 1 — — — — —  
H With set nut (For panel mount) AR10 to 40
Note) Optional parts are not assembled and are supplied loose at the time of AMR
shipment (except option E).
: Combination available : Combination not available ITV
JIS Symbol Accessory/Optional Specifications Combinations : Varies depending on the model : Available only with NPT thread
Combination
Symbol
Accessory Optional specifications Applicable regulator IC
Accessory/Optional specifications B E G H 1 N R Y Z AR10 AR20 to 40 AR50 to 60
With bracket (With set nut) B VBA
Accessory

Square embedded type pressure gauge E


Round pressure gauge G VE
With set nut (For panel mount) H
P. 14-2-52/53
0.02 to 0.2 MPa setting -1 VY1
specifications

-N
Optional

Non-relieving type
Flow direction: Right  Left -R G
Upward handle -Y
Name plate and pressure gauge
in imperial units (PSI, °F) -Z PPA
Standard Specifications
Model AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60 AL
Port size M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Set pressure range 0.05 to 0.7 MPa 0.05 to 0.85 MPa
Pressure gauge port size (1) Rc 1/16 (2) Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 Rc, NPT, G 1/4 Rc, NPT, G 1/4 Rc, NPT, G 1/4
Relief pressure Set pressure + 0.05 MPa (3) (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Construction Relieving type
Weight (kg) 0.06 0.26 0.21 0.29 0.44 0.47 1.17 1.22
Note 1) Pressure gauge connection threads are not required for regulator with a square embedded type pressure gauge (AR20 to AR60).
Note 2) Use a bushing (part no: 131368) when connecting the R 1/8 pressure gauge to the R 1/16 gauge port.
Note 3) Except AR10.
Accessory Part No.
Applicable model
AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60
Accessory
Bracket assembly (1) AR10P-270AS AR20P-270AS AR25P-270AS AR30P-270AS AR40P-270AS AR40P-270AS AR50P-270AS (5) AR50P-270AS (5)
Set nut AR10P-260S AR20P-260S AR25P-260S AR30P-260S AR40P-260S AR40P-260S — (6) — (6)
Round type G27-10-R1 G36-10-01 G36-10-01 G36-10-01 G46-10-02 G46-10-02 G46-10-02 G46-10-02
(2) 1 MPa Square (4)
Pressure embedded type — GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS
gauge Round type G27-10-R1 (3) G36-2-01 G36-2-01 G36-2-01 G46-2-02 G46-2-02 G46-2-02 G46-2-02
0.2 MPa Square (4)
embedded type — GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS
Note 1) Assembly includes a bracket and set nuts. Note 3) For 1.0 MPa.
Note 2)  in part numbers for a round pressure gauge indicates a type of Note 4) Includes one O-ring and 2 mounting screws.
connection thread. No indication is necessary for R; however, Note 5) Assembly includes a bracket and 2 mounting screws.
indicate N for NPT. Note 6) Please contact SMC regarding the set nuts for AR50 and AR60.
Please contact SMC regarding the connection thread NPT and
pressure gauge supply for PSI unit specifications.

14-2-47
48

Series AR10 to 60
Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa

Precautions AR10 M5 AR40 Rc 1/2


0.6 0.6
Be sure to read before handling.
Refer to pages 14-21-3 to 14-21-4 0.5 0.5
for Safety Instructions and Com-

Outlet pressure (MPa)

Outlet pressure (MPa)


mon Precautions. 0.4 0.4

Mounting & Adjustment 0.3 0.3

Warning 0.2 0.2


1. Set the regulator while verifying the
displayed values of the inlet and outlet 0.1 0.1
pressure gauges. Turning the knob
excessively can cause damage to the 00 00
25 50 75 100 125 150 1000 2000 3000
internal parts.
Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
2. The pressure gauge included with
regulators for 0.02 to 0.2 MPa setting is for AR20 Rc 1/4 AR40-06 Rc 3/8
up to 0.2 MPa use only. Exceeding 0.2
0.6 0.6
MPa of pressure can damage the gauge.
Nevertheless, the gauge for the AR10 0.5
0.5
regulator with 0.02 to 0.2 MPa setting is
Outlet pressure (MPa)

Outlet pressure (MPa)


for up to 1.0 MPa use.
0.4 0.4
3. Do not use tools on the pressure regulator
knob as this may cause damage. It must 0.3 0.3
be operated manually.
0.2 0.2

Caution 0.1 0.1


1. Be sure to unlock the knob before
adjusting the pressure and lock it after
0 0
setting the pressure. 0 200 400 600 800 0 1000 2000 3000 4000 5000

Failure to follow this procedure can cause Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
damage to the knob and the outlet AR25 Rc 3/8 AR50 Rc 1
pressure may fluctuate.
0.6 0.6
• Pull the pressure regulator knob to
unlock. (You can visually verify this with
0.5 0.5
the “orange mark” that appears in the
Outlet pressure (MPa)

Outlet pressure (MPa)

gap.)
0.4 0.4
• Push the pressure regulator knob to lock.
When the knob is not easily locked, turn it
0.3 0.3
left and right a little and then push it
(when the knob is locked, the “orange
mark”, i.e., the gap will disappear). 0.2 0.2

0.1 0.1

0 0
0 500 1000 1500 0 5000 10000
Orange mark Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

AR30 Rc 3/8 AR60 Rc 1


0.6 0.6

0.5 0.5
Outlet pressure (MPa)

Outlet pressure (MPa)

2. A knob cover is available to prevent 0.4 0.4


careless operation of the knob. Refer to
page 14-2-6 for details. 0.3 0.3
3. Please contact SMC when using the
regulator between a solenoid valve and an 0.2 0.2
actuator.
0.1 0.1

0 0 5000 10000
0 500 1000 1500 0
Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

14-2-48
49

Regulator Series AR10 to 60


Conditions:
Inlet pressure 0.7 MPa
Outlet pressure 0.2 MPa
Pressure Characteristics (Representative values) Flow rate 20 l/min (ANR)

AR10 AR40
0.3
0.25

0.25 Set point


Outlet pressure (MPa)

Outlet pressure (MPa)


Set point

0.2
0.2

F.R.L.
0.15

AV
0.15
00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
AU
1 1
Inlet pressure (MPa) Inlet pressure (MPa)
AF
AR20 AR40-06
AR
0.25 0.25
IR
Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point


VEX
0.2 0.2 AMR
ITV

0.15 0.15
IC
00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa) VBA

AR25 AR50 VE


0.25 0.25 VY1
G
Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point

PPA
0.2 0.2

AL

0.15 0.15
00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa)

AR30 AR60
0.25 0.25
Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point

0.2 0.2

0.15 0.15
00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa)

14-2-49
50

Series AR10 to 60
Construction
AR10 AR20/25

t
t
q
IN OUT
e
IN OUT
e q
r r
w
w

AR30/40 AR50/60

t t q
q
e e
IN OUT IN OUT

r w
w
r

Component Parts
Material
No. Description Note
AR10/20 AR25 to 40(-60) AR50/60
q Body Zinc die-casted Aluminum die-casted Platinum silver
w Bonnet Polyacetal Aluminum die-casted Black

Replacement Parts
Part no.
No. Description Materials
AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60
(2) (2) (2) (2) (2) (2) (2)
Stainless steel
e Valve assembly AR10P-090S AR20P-410AS AR25P-410AS AR30P-410AS AR40P-410AS AR40P-410AS AR50P-410AS AR60P-410AS
Brass, HNBR
r Diaphragm assembly Weatherability NBR AR10P-150AS (1) AR20P-150AS AR25P-150AS AR30P-150AS AR40P-150AS AR40P-150AS AR50P-150AS AR50P-150AS
t Valve guide assembly POM 131329 AR20P-050AS AR25P-050AS AR30P-050AS AR40P-050AS AR40P-050AS AR50P-050AS AR60P-050AS
Note 1) AR10 is a piston and gasket (KSYP-13) type assembly.
Note 2) Assembly includes valve, valve spring and stem assembly.

14-2-50
51

Regulator Series AR10 to 60


Dimensions
AR10 to 40
Square embedded type Port size Panel fitting dimension
A pressure gauge (Option) D U

C
IN T OUT
IN OUT V

S
Plate thickness F.R.L.

L
Pressure gauge AR10 to AR30: Max. 3.5

B
(Option)
AR40: Max. 5
Pressure gauge AV
M

port
N Q
AU
K F J AF
P E Bracket
(Option)
AR
IR
AR50/60
Square embedded type Port size VEX
A pressure gauge (Option) D
AMR
ITV

C
IN OUT IC
G

Pressure gauge VBA


(Option)

L
VE

B
Pressure gauge
port
VY1
M

N
Bracket
G
(Option)
Q
PPA
K F AL
P E J

(mm)
Accessory specifications
Standard specifications
Model Port size With pressure gauge Bracket mounting size Panel mount
A C B D E F G J K L M N P Q S T U V
AR10 M5 x 0.8 25 11 58 25 26 — 0 25 28 30 4.5 6.5 40 2 18 18.5 — —
AR20 1/8, 1/4 40 26.5 94 57 65 29.5 2 Note) 30 34 44 5.4 15.4 55 2.3 25 28.5 14 6
AR25 1/4, 3/8 53 28 101 55 64 28.5 0 30 34 44 5.4 15.4 55 2.3 26 32.5 16 6
AR30 1/4, 3/8 53 31 116 59 66 30.5 3.5 41 40 46 6.5 8 53 2.3 31 38.5 19 7
AR40 1/4, 3/8, 1/2 70 36 128 68 74 35 3.5 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7
AR40-06 3/4 75 36 129 68 74 35 3 50 54 56 8.5 10.5 70 2.3 37 42.5 21 7
AR50 3/4, 1 90 43 169 87 84 44.5 3.3 70 66 65.8 11 13 90 3.2 — — — —
AR60 1 95 46 176 87 84 44.5 3.3 70 66 65.8 11 13 90 3.2 — — — —
Note) For AR20 only, the position of the pressure gauge is above the center of the piping.

14-2-51
52
Regulator Series AR20 to 60
Made to Order Specifications:
Please contact SMC for detailed dimensions, specifications, and lead times.

1. Special Temperature Environment 2. High Pressure


Special materials are used in the manufacturing of seals and Strong materials are used in the manufacturing of air filters
resin parts to allow them to withstand various temperature intended for high pressure operation. Also construction
conditions in cold or tropical (hot) regions. modification allows a wider regulating pressure range.

Specifications Specifications
Part no. -X430 -X440 Part no. -X425
Environment Low temperature High temperature Proof pressure 3.0 MPa
Ambient temperature –30 to 60°C –5 to 80°C Max. operating pressure 2.0 MPa
Fluid temperature –5 to 60°C (With no freezing) Set pressure range 0.1 to 1.6 MPa
Rubber parts Special NBR FPM Ambient and fluid temperature –5 to 60°C (With no freezing)
Material
Main metal parts Metal (Aluminum die-casted)

Applicable Model Applicable Model


Model AR25 AR30 AR40 AR40-06 AR50 AR60 Model AR20 AR25 AR30 AR40 AR40-06 AR50 AR60
Port size 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1

How to Order How to Order

AR 30 F 03 BG 1N X430 AR 30 F 03 BG N X425
Regulator Regulator
For high/low
Body size temperature Body size For high
25 30 40 50 60 X430 Low temperature 20 25 30 40 50 60 pressure
X440 High temperature
Thread type Thread type
Nil Rc Nil Rc
N NPT N NPT
F G F G
Port size Port size
Port Body size Body size
Symbol Port
size 25 30 40 50 60 Symbol
size 20 25 30 40 50 60
02 1/4    — — 01 1/8  — — — — —
03 3/8    — — 02 1/4     — —
04 1/2 — —  — — 03 3/8 —    — —
06 3/4 — —   — 04 1/2 — — —  — —
10 1 — — —   06 3/4 — — —   —
Option (1) 10 1 — — — —  
Symbol Description Applicable model Option (1)
Nil — — Symbol Description Applicable model
B With bracket AR25 to 60 Nil — —
G (2) With round pressure gauge (With limit indicator) AR25 to 60 B With bracket AR20 to 60
H With set nut (For panel mount) AR25 to 40 G (2) With round pressure gauge (With limit indicator) AR20 to 60
Note 1) Optional parts are not assembled and are H With set nut (For panel mount) AR20 to 40
supplied loose at the time of shipment.
Note 1) Optional parts are not assembled and are
Note 2) Mounting thread for pressure gauge: 1/8 for
supplied loose at the time of shipment.
AR25 to 30; 1/4 for AR40 to 60
Note 2) Mounting thread for pressure gauge: 1/8 for
Pressure gauge type: G43
Option AR20 to 30; 1/4 for AR40 to 60
Symbol Description Applicable model
1 (3) 0.02 to 0.2 MPa setting AR25 to 60 Option
N Non-relieving type AR25 to 60 Symbol Description Applicable model
R Flow direction: Right  Left AR25 to 60 N Non-relieving AR20 to 60
Y Upward handle AR25 to 60 R Flow direction: Right  Left AR20 to 60
Z (4) Name plate and pressure gauge in imperial units (PSI, °F) AR25 to 60 Y Upward handle AR20 to 60
∗ When more than one specification is required, indicate in ascending Z (3) Name plate and pressure gauge in imperial units (PSI, °F) AR20 to 60
alphanumeric order.
Note 3) The only difference from the standard specifications is the
∗ When more than one specification is required, indicate in
adjusting spring for the regulator. It does not restrict the ascending alphanumeric order.
setting of 0.2 MPa or more. Note 3) For thread type NPT.
Note 4) For thread type NPT. This product is for overseas use only according to the
This product is for overseas use only according to the new new Measurement Law. (The SI unit type is provided for
Measurement Law. (The SI unit type is provided for use in use in Japan.)
Japan.)
Note 5) Please consult with SMC for detailed dimensions and available attachments and options.
Note 6) Comes with type T handle.

14-2-52
53
Regulator Series AR20(K) to AR60(K)
Made to Order Specifications:
Please contact SMC for detailed dimensions, specifications, and lead times.

3. With Digital Pressure Switch


Digital pressure switch (ISE30---L) is supplied loose for mounting on pressure gauge connection port.

Specifications Applicable Model F.R.L.


Part no. -X465 Model AR20(K) AR25(K) AR30(K) AR40(K) AR40(K)-06 AR50(K) AR60(K)
Model ISE30---L Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 AV
Set pressure range (MPa) –0.1 to 1
Pressure Set and display resolution (MPa) 0.001
AU
switch 12 to 24 VDC ± 10%, Ripple (p-p) 10%
Power supply voltage
or less (With power supply polarity protection)
Power consumption 45 mA or less (70 mA or less for current output) AF
∗ Pressure gauge port size: 1/8
AR
IR
VEX
AMR
ITV
How to Order IC
AR 30 K F 03 B 1N X465 A VBA
Regulator Switch specifications
Symbol Output specifications
VE
Body size With digital pressure switch
(4)
A NPN output
20 25 30 40 50 60 (Series ISE30) B PNP output
VY1
Note 4) Digital pressure switch is not assembled C 1 to 5 V output
and are supplied loose at the time of D 4 to 20 mA output G
Back flow mechanism shipment.
Note 5) Please consult with SMC for detailed
Nil Without back flow mechanism PPA
dimensions and available attachments
K With back flow mechanism and options.
Note 6) Refer to SMC catalog CAT.ES100-42 for
detailed specifications and instructions AL
Thread type
of digital pressure switch.
Nil Rc
N NPT Option
F G Symbol Description Applicable model
1 (2) 0.02 to 0.2 MPa setting AR20(K) to 60(K)
N Non-relieving type AR20(K) to 60(K)
Port size
R Flow direction: Right  Left AR20(K) to 60(K)
Port Body size Y Upward handle AR20(K) to 60(K)
Symbol size
20 25 30 40 50 60 Z (3) Name plate and pressure gauge in imperial units (PSI, °F) AR20(K) to 60(K)
01 1/8  — — — — — ∗ When more than one specification is required, indicate in ascending
02 1/4     — — alphanumeric order.
Note 2) The only difference from the standard specifications is the adjusting
03 3/8 —    — — spring for the regulator. It does not restrict the setting of 0.2 MPa or
04 1/2 — — —  — — more.
06 3/4 — — —   — Note 3) For thread type NPT.
This product is for overseas use only according to the new
10 1 — — — —   Measurement Law. (The SI unit type is provided for use in Japan.)

Option (1)
Symbol Description Applicable model
Nil — —
B With bracket AR20(K) to 60(K)
H With set nut (For panel mount) AR20(K) to 40(K)
Note 1) Optional parts are not assembled and are supplied loose at the time of
shipment.

14-2-53
54

Regulator with Back Flow Mechanism

Series AR20K to 60K


How to Order
Regulator with a built-in
mechanism that ensures a
quick release of the outlet air
AR 30 K F 03 BE 1N
pressure (built-in check valve Regulator Option
with back flow mechanism). Body size Symbol Description Applicable model
1 (2) 0.02 to 0.2 MPa setting AR20K to 60K
20 25 30 40 50 60
N Non-relieving AR20K to 60K
With back flow mechanism R Flow direction: Right  Left AR20K to 60K
Note) AR10 comes with a back flow Y Upward handle AR20K to 60K
mechanism as a standard feature. Name plate and pressure
If the set pressure is below 0.15 Z (3) gauge in imperial units AR20K to 60K
MPa, back flow may not occur. (PSI, °F)
When a backflow mechanism is
∗ When more than one specification is
required with a set pressure of less
required, indicate in alphanumeric
than 0.15 MPa, please ccontact
order.
AR20K SMC.
Note 2) The only difference from the
AR40K Thread type standard specifications is the
Example 1) adjusting spring for the
When the pressure in the rear and Nil Rc regulator. It does not restrict
the front of the cylinder differs: N NPT the setting of 0.2 MPa or
Circuit diagram F G more.
Port size Note 3) For NPT thread type.
Port Body size This product is for overseas
Symbol use only according to the new
size 20 25 30 40 50 60
Measurement Law. (The SI
01 1/8  — — — — —
unit type is provided for use in
Example 2) 02 1/4     — — Japan.)
When the air supply is cut off and 03 3/8 —    — — Accessory (1)
releasing the inlet pressure to the 04 1/2 — — —  — —
atmosphere, the residual pressure Symbol Description Applicable model
06 3/4 — — —   —
release of the outlet side can be Nil — —
ensured for a safety purpose. 10 1 — — — —  
B With bracket AR20K to 60K
With square embedded type
Circuit diagram JIS Symbol E pressure gauge (With limit indicator) AR20K to 60K
G With round pressure gauge AR20K to 60K
(With limit indicator)
H With set nut (For panel mount) AR20K to 40K

Note 1) Optional parts are not assembled and are


supplied loose at the time of shipment (except
option E).
Standard Specifications
Model AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K
Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Set pressure range (1) 0.05 to 0.85 MPa
Pressure gauge port size (2) Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 Rc, NPT, G 1/4 Rc, NPT, G 1/4 Rc, NPT, G 1/4
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5° to 60°C (With no freezing)
Construction Relieving type
Weight (kg) 0.26 0.21 0.30 0.45 0.48 1.17 1.22
∗ AR10 comes with a back flow mechanism as a standard feature. Note 1) Set the inlet pressure 0.05 MPa or higher than the set pressure.
Note 2) Pressure gauge connection threads are not required for regulators with a
square embedded type pressure gauge (AR20K to AR60K).
Accessory Part No.
Accessory Applicable model AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K
Bracket assembly (1) AR20P-270AS AR25P-270AS AR30P-270AS AR40P-270AS AR40P-270AS AR50P-270AS (3) AR50P-270AS (3)
Set nut AR20P-260S AR25P-260S AR30P-260S AR40P-260S AR40P-260S — (5) — (5)
Round type G36-10-01 G36-10-01 G36-10-01 G46-10-02 G46-10-02 G46-10-02 G46-10-02
(2) 1.0 MPa Square (4)
Pressure embedded type GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3-10AS
gauge Round type G36-2-01 G36-2-01 G36-2-01 G46-2-02 G46-2-02 G46-2-02 G46-2-02
0.2 MPa Square (4)
embedded type GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS
Note 1) Assembly includes a bracket and set nuts. Note 3) Assembly includes a bracket and 2 mounting screws.
Note 2)  in part numbers for a round pressure gauge indicates a type of connection Note 4) Includes one O-ring and 2 mounting screws.
thread. No indication is necessary for R; however, indicate N for NPT. Note 5) Please contact SMC regarding the set nut for AR50K and 60K.
Please contact SMC regarding the connection thread NPT and pressure
gauge supply for PSI unit specifications.

14-2-54
55

Regulator with Back Flow Mechanism Series AR20K to 60K


Working Principle
Precautions
A-A
A
w Be sure to read before handling.
Refer to pages 14-21-3 to 14-21-4
for Safety Instructions and
OUT
Common Precautions.
1

Mounting & Adjustment


IN

F.R.L.
2

SMC Warning
1. Set the regulator while verifying the AV
displayed values of the inlet and outlet
pressure gauges. Turning the regulator AU
A
knob excessively can cause damage to
the internal parts.
2. Do not use tools on the pressure regulator AF
knob as this may cause damage. It must
be operated manually. AR
r Caution IR
1. Be sure to unlock the knob before
adjusting the pressure and lock it after VEX
IN OUT
Figure 1
setting the pressure.
(Inlet pressure) (Outlet pressure)
w Normal Failure to follow this procedure can cause
damage to the knob and the outlet AMR
pressure may fluctuate.
q ITV
e Inlet pressure Pressure in
(IN) diaphragm chamber IC
Figure 3 VBA
Orange mark
Figure 2 VE
Back flow
VY1
IN OUT • Pull the pressure regulator knob to
unlock. (You can visually verify this with
G
Inlet pressure Pressure in the “orange mark” that appears in the
(IN) diaphragm chamber
gap.) PPA
• Push the pressure regulator knob to lock.
When the knob is not easily locked, turn it AL
left and right a little and then push it
(when the knob is locked, the “orange
mark”, i.e., the gap will disappear).
2. A knob cover is available to prevent
careless operation of the knob. Refer to
When the inlet pressure (P1) is higher than the regulating pressure, the check valve
page 14-2-6 for details.
w closes and operates as a normal regulator (Figure 1).
When the inlet pressure (P1) is shut off and released, the check valve w opens and
the pressure in the diaphragm chamber q is released into the inlet side (Figure 2). Maintenance
This lowers the pressure in the diaphragm chamber q and the force generated by the
pressure regulator spring e lifts the diaphragm. Valve r opens through the stem, Warning
and the outlet pressure is released to the inlet side (Figure 3). 1. When using the regulator between a
solenoid valve and an actuator, check the
pressure gauge periodically.
Sudden pressure fluctuations may shorten
the durability of the pressure gauge. A
digital pressure gauge is recommended
for such situation or as deemed
necessary.

14-2-55
56

Series AR20K to 60K


Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa

AR20K Rc 1/4 AR40K-06 Rc 3/8


0.6 0.6

0.5 0.5
Outlet pressure (MPa)

Outlet pressure (MPa)


0.4 0.4

0.3 0.3

0.2 0.2

0.1 0.1

0 0
0 200 400 600 800 0 1000 2000 3000 4000 5000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

AR25K Rc 3/8 AR50K Rc 1


0.6 0.6

0.5 0.5
Outlet pressure (MPa)

Outlet pressure (MPa)

0.4 0.4

0.3 0.3

0.2 0.2

0.1 0.1

0 0
0 500 1000 1500 0 5000 10000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

AR30K Rc 3/8 AR60K Rc 1


0.6 0.6

0.5 0.5
Outlet pressure (MPa)

Outlet pressure (MPa)

0.4 0.4

0.3 0.3

0.2 0.2

0.1 0.1

0 0 5000 10000
0 500 1000 1500 0
Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

AR40K Rc 1/2
0.6

0.5
Outlet pressure (MPa)

0.4

0.3

0.2

0.1

00
1000 2000 3000
Flow rate (l/min (ANR))

14-2-56
57

Regulator with Back Flow Mechanism Series AR20K to 60K


Conditions:
Inlet pressure 0.7 MPa
Outlet pressure 0.2 MPa
Pressure Characteristics (Representative values) Flow rate 20 l/min (ANR)

AR20K AR40K-06
0.25 0.25
Outlet pressure (MPa)

Outlet pressure (MPa)


Set point Set point

0.2 0.2

F.R.L.
AV
0.15 0.15
00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
AU
1 1
Inlet pressure (MPa) Inlet pressure (MPa)
AF
AR25K AR50K
AR
0.25 0.25
IR
Outlet pressure (MPa)
Outlet pressure (MPa)

Set point Set point


VEX
0.2 0.2 AMR
ITV

0.15 0.15
IC
00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
Inlet pressure (MPa)
1
Inlet pressure (MPa)
1
VBA

AR30K AR60K VE


0.25 0.25 VY1
G
Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point

PPA
0.2 0.2

AL

0.15 0.15
00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa)

AR40K
0.25
Outlet pressure (MPa)

Set point

0.2

0.15
00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa)

14-2-57
58

Series AR20K to 60K


Construction
AR20K to 60K

A-A
A

OUT
1
IN

SMC

e t

IN OUT

r
q

Component Parts
Material
No. Description Note
AR20K AR25K to 40K(-06) AR50K/60K
q Body Zinc die-casted Aluminum die-casted Platinum silver
w Bonnet Polyacetal Aluminum die-casted Black

Replacement Parts
Part no.
No. Description Material
AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K
Stainless steel (2) (2) (2) (2) (2) (2) (2)
e Valve assembly AR20P-410AS AR25P-410AS AR30P-410AS AR40P-410AS AR40P-410AS AR50P-410AS AR60P-410AS
Brass, HNBR
Weatherability
r Diaphragm assembly AR20P-150AS AR25P-150AS AR30P-150AS AR40P-150AS AR40P-150AS AR50P-150AS AR50P-150AS
NBR
t Valve guide assembly POM AR20P-050AS AR25P-050AS AR30P-050AS AR40P-050AS AR40P-050AS AR50P-050AS AR60P-050AS
(1) —
y Check valve assembly AR20KP-020AS AR20KP-020AS AR20KP-020AS AR20KP-020AS AR20KP-020AS AR20KP-020AS AR20KP-020AS
Note 1) Check valve construction includes a check valve cover and 2 screws.
Note 2) Assembly includes valve, valve spring and stem assembly.

14-2-58
59

Regulator with Back Flow Mechanism Series AR20K to 60K


Dimensions
AR20K to 40K
Square embedded type Port size Panel fitting dimension
A pressure gauge (Option) D U

C
IN OUT IN T OUT
V

G
F.R.L.

S
Plate thickness

L
Pressure gauge

B
(Option) AR20K to AR30K: Max. 3.5
AR40K: Max. 5 AV
M

Pressure gauge
port size
Bracket
N Q
(Option) AU

K F J AF
P E
AR
IR

AR50K/60K
VEX
Square embedded type
A pressure gauge (Option) D
AMR
ITV

C
IN OUT IC
G

VBA
Pressure gauge

L
(Option)
VE

B
Pressure gauge
VY1
M

port size

N Port size Bracket


(Option)
G
Q
PPA
K F J AL
P E

(mm)
Accessory specifications
Standard specifications
Model Port size With pressure gauge Bracket mounting size Panel mount
A B C D E F G J K L M N P Q S T U V
AR20K 1/8, 1/4 40 94 26.5 57 65 29.5 2 Note) 30 34 44 5.4 15.4 55 2.3 25 28.5 14 6
AR25K 1/4, 3/8 53 101 28 55 64 28.5 0 30 34 44 5.4 15.4 55 2.3 26 32.5 16 6
AR30K 1/4, 3/8 53 116 31 59 66 30.5 3.5 41 40 46 6.5 8 53 2.3 31 38.5 19 7
AR40K 1/4, 3/8, 1/2 70 128 36 68 74 35 3.5 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7
AR40K-06 3/4 75 129 36 68 74 35 3 50 54 56 8.5 10.5 70 2.3 37 42.5 21 7
AR50K 3/4, 1 90 169 43 87 84 44.5 3.3 70 66 65.8 11 13 90 3.2 — — — —
AR60K 1 95 176 46 87 84 44.5 3.3 70 66 65.8 11 13 90 3.2 — — — —
Note) For AR20K only, the position of the pressure gauge is above the center of the piping.

14-2-59
60

Modular Style
Lubricator

Series AL
Lubricator Model Port size Accessory
Series AL
AL10 M5 x 0.8

AL20 1/8, 1/4

AL30 1/4, 3/8

AL40 1/4, 3/8, 1/2 Bracket

AL40-06 3/4

AL50 3/4, 1

Pages 14-2-61 to 14-2-65 AL60 1

14-2-60
61

Lubricator

Series AL10 to 60
How to Order

AL 30 F 03 B 2R
Lubricator Option
Symbol Description Applicable model
Body size
1 1000 cm3 tank AL30 to 60
F.R.L.
10 20 30 40 50 60 10 1000 cm3 tank with level switch (Lowest limit ON) AL30 to 60
Thread type 11 1000 cm3 tank with level switch (Lowest limit OFF) AL30 to 60 AV
2 Metal bowl AL10 to 60
Metric thread
Nil (M5)
3 With drain cock AL10 to 60 AU
Rc
6 Nylon bowl (Including sight dome) AL10 to 60
8 Metal bowl with level gauge AL30 to 60
N NPT
C With bowl guard AL20
AF
AL20 F G
Port size R Flow direction: Right  Left AL10 to 60
Port Body size 3W Drain cock with barb fitting: ø6 x ø4 nylon tubing AL30 to 60 AR
Symbol
size 10 20 30 40 50 60 Z (2) Name plate and caution plate for bowl in imperial units (PSI, °F) AL10 to 60
M5 M5  — — — — — ∗ When more than one specification is required, indicate in alphanumeric order. IR
Accessory
01 1/8 —  — — — — Note 2) For M5 and NPT thread types.
02 1/4 —    — — Symbol Description Applicable model This product is for overseas use only
03 3/8 — —   — — Nil — — according to the new Measurement
Law. (The SI unit type is provided for
VEX
04 1/2 — — — — — — B (1) With bracket AL20 to AL 60 use in Japan.)
06 3/4 — — — —  — Note 1) Bracket is not assembled and is
supplied loose at the time of shipment.
AMR
10 1 — — — —  
: Combination available : Combination not available
Accessory/Optional Specifications Combinations : Varies depending on the model : Available only with NPT thread ITV
Symbol

Combination Accessory Optional specifications Applicable lubricator


Accessory/Optional specifications B 1 10 11 2 3 6 8 C R 3W Z AL10 AL20 AL30 to 60 IC
Accessory With bracket B
AL40 1000 cm3 tank -1 VBA
1000 cm3 tank with level switch (Lowest limit ON) -10
Optional specifications

1000 cm3 tank with level switch (Lowest limit OFF) -11
Metal bowl -2 VE
JIS Symbol
With drain cock -3
Nylon bowl (Including sight dome) -6 VY1
Metal bowl with level gauge -8
With bowl guard -C G
Flow direction: Right  Left -R
Drain cock with barb fitting: ø6 x ø4 nylon tubing -3W
Name plate and caution plate for bowl in imperial units (PSI, °F) -Z
PPA
Note) -1, -10, -11 are for a metal bowl with level gauge that comes with drain cock.
AL
Standard Specifications
Model AL10 AL20 AL30 AL40 AL40-06 AL50 AL60
Port size M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Note)
1/4: 30 1/4: 30
Minimum dripping flow rate (l/min (ANR)) 4 15 3/8: 40 50 190 220
3/8: 40 1/2: 50
Oil capacity (cm3) 7 25 55 135 135 135 135
Recommended lubricant Class 1 turbine oil (ISO VG32)
Ambient and fluid temperature –5 to 60°C (With no freezing)
Bowl material Polycarbonate
Bowl guard — Option Standard
Weight (kg) 0.07 0.20 0.24 0.47 0.52 1.06 1.13
Note 1) • The flow rate is 5 drips/min under the following conditions: Inlet pressure of 0.5 MPa; Class 1
turbine oil (ISO VG32); Temperature at 20°C; Oil adjustment valve fully open.
• Use air consumption flow rate for minimum dripping flow rate.
Accessory Part No.
Accessory Applicable model AL10 AL20 AL30 AL40 AL40-06 AL50 AL60
Bracket assembly Note) — AF20P-050AS AF30P-050AS AF40P-050AS AF40P-070AS AF50P-050AS AF50P-050AS
∗ The part number for bracket assembly for 1000 cm3 is AF50P-050AS (applicable to AL30 to AL60).
Note) Assembly includes a bracket and 2 mounting screws.

14-2-61
62

Series AL10 to 60
Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa Working Principle: Type AL10
AL10 M5 AL40-06 Rc 3/4
0.1
0.1
turn
open

turn

r ns

turns

Pa
Pa

a
MP
5 tu

0.5 M
0.5

0.3 M
n 1.0
Needle fully

n 2.0
Pressure drop (MPa)

Pressure drop (MPa)


0.08

.7
0.08 n 1.
Open

=0
Ope

MPa
Ope

P1 =
Ope

P1 =

P1
P1 = 0.1
0.06 0.06

0.04 0.04

0.02 0.02
Conditions: P1 = 0.5 MPa
Needle: One side fully open
0 0
0 50 100 150 200 0 2000 4000 6000 8000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

AL20 Rc 1/4 AL50 Rc 1


0.1 0.1

Pa

Pa

Pa
Pa

M A portion of the air introduced from the IN


Pa

M
.7 M

.3
side pressurizes the lubricant inside the
5

7
.5 M

0.

0.
=0
Pressure drop (MPa)

Pressure drop (MPa)

0.08 0.08
=0

bowl. The remainder of the air passes


=

=
P1
=0

P1
P1
a
Pa

through the needles o, and flows to the


MP

P1
0.1 M

P1

OUT side. The pressure differential between


a

0.06
0.3

0.06
MP

the inside of the bowl and the inside of the


P1 =
P1 =

.1

sight dome w, causes the lubricant inside


=0

0.04 0.04
the bowl into the oil passage !0 . The
P1

lubricant drips from the dripping tube !1, and


0.02 0.02 lubricate the OUT side. The amount of
lubricant is adjusted by the needle o, on the
0
front face. Turning the needle clockwise
0
0 1000 2000 3000 4000 0 5000 10000 15000 increases the amount of the lubricant, and
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) turning it counterclockwise until fully opened
shuts off the lubricant. The needle on the
side that is not used should be left fully
AL30 Rc 3/8 AL60 Rc 1
opened.
0.1 0.1
Note) The operating principle for AL20 to 60
types is different from that of AL10
Pressure drop (MPa)

Pressure drop (MPa)

0.08 0.08 Pa
Pa

M
Precautions
Pa
a

M
Pa

Pa

7
0.
MP
Pa

5
M

0.

=
3
0.1 M

7
5
.3

0.

P1
=

0.06 0.06
0.
0.
=0

P1
=

Be sure to read before handling.


=

Pa
=

P1
P1
P1
P1

M
P1 =

Refer to pages 14-21-3 to 14-21-4


.1

0.04 0.04
=0

for Safety Instructions and


P1

Common Precautions.
0.02 0.02

Selection
0 0
0 2000
Flow rate (l/min (ANR))
4000 6000 0 5000
Flow rate (l/min (ANR))
10000 15000
Warning
Piping
1. Do not introduce air from the outlet side
as this can damage the damper.
AL40 Rc 1/2
0.1 Caution
1. Use a check valve (Series AKM) to
prevent back flow of the lubricant when
Pressure drop (MPa)

0.08
redirecting the air flow before the
a
MPa
MPa

MP
MP

lubricator.
.7
0.5
P1 = 0.1

0.06
0.3

Maintenance
=0
P1 =
P1 =

P1

0.04 Warning
1. For AL 10 and AC20 type, replenish the
0.02 lubricant after releasing the inlet pressure.
Lubrication cannot take place under a
0
pressurized condition.
0 2000 4000 6000 8000
Flow rate (l/min (ANR)) Caution
1. Check the dripping amount once a day.
Drip failure can cause damage to the
components that need lubrication.

14-2-62
63

Lubricator Series AL10 to 60


Construction
AL10 AL20
JIS Symbol
w
w q e
q t
IN OUT IN OUT
F.R.L.
y y
u r AV
u AU
AF

AL30/40 AL50/60 AR
IR
w w
qe qe VEX
t t AMR
IN OUT IN OUT

ITV
y r
r i IC
u
VBA
VE
VY1
y
u
G
PPA
AL

Component Parts
Material
No. Description Note
AL10/20 AL30/40/40-06 AL50/60
q Body Zinc die-casted Aluminum die-casted Platinum silver
i Housing — Aluminum die-casted Platinum silver

Replacement Parts
Part no.
No. Description Material
AL10 AL20 AL30 AL40 AL40-06 AL50 AL60
w Sight dome assembly PC AL10P-080AS AL20P-080AS AL20P-080AS AL20P-080AS AL20P-080AS AL20P-080AS AL20P-080AS
e Lubrication plug assembly — — AL20P-060AS AL30P-060AS AL40P-060AS AL40P-060AS AL40P-060AS AL40P-060AS
r Damper retainer assembly (1) — — AL20P-030AS AL30P-030AS AL40P-030AS AL40P-030AS AL50P-030AS AL60P-030AS
t Damper assembly Synthetic resin — AL20P-040S AL30P-040S AL40P-040S AL40P-040S AL50P-040AS AL60P-040AS
y Bowl O-ring NBR C1SFP-260S C2SFP-260S C3SFP-260S C4SFP-260S C4SFP-260S C4SFP-260S C4SFP-260S
u Bowl assembly (2) PC C1SL C2SL C3SL (3) C4SL (3) C4SL (3) C4SL (3) C4SL (3)
Note 1) Add “-1” at the end of the part number when ordering a damper retainer assembly for 1000 cm3.
Example) AL30P-030AS-1
Note 2) Including O-ring. Please contact SMC regarding the bowl assembly supply for PSI and °F unit specifications.
Note 3) Bowl assembly for AL30 to AL60 comes with a bowl guard (steel band material).

14-2-63
64

Series AL10 to 60
Dimensions
AL10 L AL20
D
G Bracket
(Option) F
K Port size M
A Port size

C
C

J
H
IN OUT IN
OUT
OUT
B
OUT

B
P Min. clearance
R

for maintenance Min. clearance


A for maintenance

R
AL30/40 AL50/60
L D
L Bracket D Port size
G Bracket F
G (Option) Port size F M
K (Option)
K M

E
J

C
C

H
J
H

IN OUT IN OUT

OUT OUT
B

A P B
R

Min. clearance
for maintenance

A Min. clearance
R

for maintenance

Applicable model AL10, AL20 AL30, AL40, AL40-06, AL50, AL60


Metal bowl with Metal bowl with Metal bowl with Metal bowl with drain Drain cock with
With drain cock drain cock Metal bowl With drain cock level gauge drain cock cock & level gauge barb fitting

Optional
specifications B
B
B

B
B

B
B

Barb fitting
Applicable tubing: T0604

(mm)
Accessory specifications
Standard specifications
Model Port size Bracket mounting size
A B C D P R E F G H J K L M
AL10 M5 x 0.8 25 77 26 25 28 35 — — — — — — — —
AL20 1/8, 1/4 40 115 36 40 — 60 — 30 27 22 5.4 8.4 40 2.3
AL30 1/4, 3/8 53 142 38 53 57 80 — 41 40 23 6.5 8 53 2.3
AL40 1/4, 3/8, 1/2 70 176 40 70 73 110 — 50 54 26 8.5 10.5 70 2.3
AL40-06 3/4 75 176 38 70 73 110 — 50 54 25 8.5 10.5 70 2.3
AL50 3/4, 1 90 250 41 90 — 110 47 70 66 35 11 13 90 3.2
AL60 1 95 268 45 95 — 110 47 70 66 35 11 13 90 3.2
Optional specifications
Model With drain cock With barb fitting Metal bowl Metal bowl with drain cock Metal bowl with level gauge Metal bowl with drain cock & level gauge
B B B B B B
AL10 85 — 82 85 — —
AL20 123 — 121 124 — —
AL30 153 161 142 166 162 186
AL40 187 195 176 200 196 220
AL40-06 187 195 176 200 196 220
AL50 261 269 250 274 270 294
AL60 279 287 268 292 288 312

14-2-64
65

Lubricator Series AL10 to 60


Dimensions
Option: 1000 cm3 tank

106
90
E Bracket Port size 106
66 (Option) 70
13 3.2

F.R.L.
11

P
H
IN OUT AV
OUT AU
AF
AR
IR
With float switch
VEX
B

Specifications

Contact capacity: 15 VA(AC)


15 W(DC)
Contact point: 1a, 1b
AMR
ITV
IC
VBA
B

VE
VY1
for maintenance
Min. clearance
210

Float switch
PPA
G 1/2 Part no: IS400-1 to 2
AL
210

for maintenance
Min. clearance

(mm)
With bracket With float switch
Model Port size B C E
H P B
AL30 1/4, 3/8 324 38 53 25 — 374
AL40 1/4, 3/8, 1/2 333 40 70 18 — 383
AL40-06 3/4 333 38 75 16 — 383
AL50 3/4, 1 332 41 90 35 47 382
AL60 1 335 45 95 35 47 385

14-2-65
66

Modular Style
Filter Regulator

Series AW
Filter regulator Model Port size Filtration Accessory
Series AW
AW10 M5 x 0.8

AW20 1/8, 1/4

AW30 1/4, 3/8

AW40 1/4, 3/8, 1/2

Pages 14-2-67 to 14-2-73 AW40-06 3/4

Filter regulator with 5 µm


back flow mechanism AW20K 1/8, 1/4
Series AWK

AW30K 1/4, 3/8

AW40K 1/4, 3/8, 1/2

Bracket
Square embedded
AW40K-06 3/4 type pressure gauge
Pages 14-2-74 to 14-2-77 (Except AR10)
Mist separator Round pressure
regulator gauge
Series AWM AWM20 1/8, 1/4 Panel mount

AWM30 1/4, 3/8


0.3 µm
(95% filtered
particle size)

AWM40 1/4, 3/8, 1/2

Pages 14-2-78 to 14-2-81


Micro mist separator
regulator
Series AWD AWD20 1/8, 1/4

AWD30 1/4, 3/8


0.01 µm
(95% filtered
particle size)

AWD40 1/4, 3/8, 1/2

Pages 14-2-82 to 14-2-85

14-2-66
67

Filter Regulator

Series AW10 to 40
Integrated filter and regulator units save
space and require less piping.
Direct operated, relieving type

JIS Symbol F.R.L.


AV
P. 14-2-72 AW20 AU
How to Order AW40
AF
AR
AW 30 F 03 BE 1N
Filter Option IR
regulator Symbol Description Applicable model
Body size 1 (5) 0.02 to 0.2 MPa setting AW10 to 40 VEX
10 20 30 40 2 Metal bowl AW10 to 40
6 Nylon bowl AW10 to 40 AMR
Thread type 8 Metal bowl with level gauge AW30/40
C With bowl guard AW20
Nil
Metric thread (M5)
J (6) Drain guide 1/4 AW30/40
ITV
Rc
N (1) NPT N Non-relieving AW10 to 40

F (2) G R Flow direction: Right  Left AW10 to 40 IC


Note 1) Drain guide is NPT 1/4
W Drain cock with barb fitting: ø6 x ø4 nylon tubing AW30/40
(applicable to AW30 and Z (7) Name plate, caution plate for bowl, and pressure gauge in imperial units (PSI, °F) AW10 to 40 VBA
40), and the exhaust ∗ When more than one specification is required, indicate in alphanumeric order.
port for auto- drain Note 5) The only difference from the standard specifications is the adjusting spring for
comes with ø3/8" One- the regulator. It does not restrict the setting of 0.2 MPa or more. VE
touch fitting (applicable Note 6) Without a valve function.
to AW30 and AW40).
Note 2) Drain guide is G 1/4
Note 7) For M5 and NPT thread types. This product is for overseas use only according to
the new Measurement Law. (The SI unit type is provided for use in Japan.)
VY1
(applicable to AW30 and Accessory (3)

AW40). Symbol Description Applicable model G


Nil — —
Port size
B With bracket AW10 to 40 PPA
Port Body size
Symbol C Float type auto-drain (N.C.) (4) AW10 to 40
size 10 20 30 40
D Float type auto-drain (N.O.) (4) AW30/40
M5 M5  — — — E With square embedded type pressure gauge (With limit indicator) AW20 to 40
AL
01 1/8 —  — — With round pressure gauge (Without limit indicator) AW10
02 1/4 —    G
With round pressure gauge (With limit indicator) AW20 to 40
03 3/8 — —   H With set nut (For panel mount) AW10 to 40
04 1/2 — — —  Note 3) Optional parts are not assembled and are supplied loose at the time of shipment (except
06 3/4 — — —  options C, D and E).
Note 4) Applicable tubing O.D for auto drain connection should be ø3/8" in case NPT thread port is
chosen.
: Combination available : Combination not available
Accessory/Optional Specifications Combinations : Varies depending on the model : Available only with NPT thread
Symbol

Combination Accessory Optional specifications Applicable filter regulator


Accessory/Optional specifications B C D E G H 1 2 6 8 C J N R W Z AW10 AW20 AW30 to 40
With bracket (With set nut) B
Float type auto-drain (N.C.) C
Accessory

Float type auto-drain (N.O.) D


Square embedded type pressure gauge E
Round pressure gauge G
With set nut (For panel mount) H
0.02 to 0.2 MPa setting -1
Metal bowl -2
Optional specifications

Nylon bowl -6
Metal bowl with level gauge -8
With bowl guard -C
Drain guide 1/4 -J
Non-relieving type -N
Flow direction: Right  Left -R
Drain cock with barb fitting: ø6 x ø4 nylon tubing -W
Name plate, caution plate for bowl, and pressure
gauge in imperial units (PSI, °F) -Z

14-2-67
68

Series AW10 to 40
Standard Specifications
Model AW10 AW20 AW30 AW40 AW40-06
Port sizes M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Set pressure range 0.05 to 0.7 MPa 0.05 to 0.85 MPa
Pressure gauge port size (1) Rc 1/16 (2) Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 Rc, NPT, G 1/4
Relief pressure Set pressure + 0.05 MPa (3) (at relief flow rate of 0.1 l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating 5 µm
Drain capacity (cm3) 2.5 8 25 45 45
Bowl material Polycarbonate
Bowl guard — Option Standard
Construction Relieving type
Weight (kg) 0.09 0.32 0.40 0.72 0.75
Note 1) Pressure gauge connection threads are not required for regulators with a square embedded type pressure gauge (AW20 to AW40).
Note 2) Use a bushing (part no: 131368) when connecting R 1/8 pressure gauge to R 1/16 gauge port.
Note 3) Not applicable to AW10.
Accessory Part No.
Applicable model
AW10 AW20 AW30 AW40 AW40-06
Accessory
Bracket assembly (1) AR10P-270AS AW20P-270AS AR30P-270AS AR40P-270AS AR40P-270AS
Set nut AR10P-260S AR20P-260S AR30P-260S AR40P-260S AR40P-260S
Round Type G27-10-R1 G36-10-01 G36-10-01 G46-10-02 G46-10-02
(2) 1.0 MPa (4)
Pressure Square embedded type — GC3-10AS GC3-10AS GC3-10AS GC3-10AS
gauge Round Type G27-10-R1 (3) G36-2-01 G36-2-01 G46-2-02 G46-2-02
0.2 MPa (4)
Square embedded type — GC3-2AS GC3-2AS GC3-2AS GC3-2AS
(5)
Float type N.O. — — AD38 AD38N (6)
AD48 AD48N (6)
AD48 AD48N(6)
auto-drain N.C. AD17 AD27 AD37 AD37N (6)
AD47 AD47N (6)
AD47 AD47N(6)
Note 1) Assembly includes a bracket and set nuts.
Note 2)  in part numbers for a round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N for
NPT. Please contact SMC regarding the connection thread NPT and supply of the pressure gauge for PSI unit specifications.
Note 3) For 1 MPa.
Note 4) Includes one O-ring and 2 mounting screws.
Note 5) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.1 MPa (AD17/27) and 0.15 MPa (AD37/47). Please contact SMC regarding the
specifications for PSI unit and °F.
Note 6) When “N” is specified in the end of part number of auto-drain, applicable tubing O.D should be ø3/8".

Precautions
Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions.

Selection Mounting & Adjustment

Warning Warning • Pull the pressure regulator knob to


1. Residual pressure release (outlet 1. Set the regulator while checking the unlock. (You can visually verify this
pressure release) is not completed by displayed values of the inlet and outlet with the “orange mark” that appears in
releasing inlet pressure. To release pressure gauges. Turning the knob the gap.)
residual pressure, use a filter regulator excessively can cause damage to the • Push the pressure regulator knob to
with a back flow mechanism. internal parts. lock. When the knob is not easily
2. The pressure gauge indicated with locked, turn it left and right a little and
regulators for 0.02 to 0.2 MPa setting is then push it (when the knob is locked,
for 0.2 MPa use only. Exceeding 0.2 the “orange mark” will disappear).
Maintenance MPa of pressure can damage the
gauge.
Warning 3. Do not use tools on the pressure
Orange mark

1. Replace the element every 2 years or regulator knob as this may cause
when the pressure drop becomes 0.1 damage. It must be operated manually.
MPa, whichever comes first, to prevent
damage to the element. Caution
1. Be sure to unlock the knob before
adjusting the pressure and lock it after
setting the pressure. 2. A knob cover is available to prevent
Failure to follow this procedure can careless operation of the knob. Refer to
cause damage to the knob and the page 14-2-6 for details.
outlet pressure may fluctuate.

14-2-68
69

Filter Regulator Series AW10 to 40


Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa

AW10 M5 AW30 Rc 3/8 AW40-06 Rc 3/4


0.6 0.6 0.6

0.5 0.5 0.5

Outlet pressure (MPa)

Outlet pressure (MPa)


Outlet pressure (MPa)

0.4 0.4 0.4

0.3 0.3 0.3

F.R.L.
0.2 0.2 0.2

AV
0.1 0.1 0.1

0 0 0
AU
0 25 50 75 100 125 150 0 500 1000 1500 0 1000 2000 3000 4000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
AF
AW20 Rc 1/4 AW40 Rc 1/2
0.6 0.6
AR
0.5 0.5
IR
Outlet pressure (MPa)
Outlet pressure (MPa)

0.4 0.4
VEX
0.3 0.3
AMR
0.2 0.2

ITV
0.1 0.1

0 0
IC
0 200 400 600 800 0 1000 2000 3000
Flow rate (l/min (ANR)) Flow rate (l/min (ANR))
VBA

Pressure Characteristics (Representative value) Conditions: Inlet pressure 0.7 MPa; Outlet pressure 0.2 MPa; Flow rate 20 l/min (ANR)
VE
AW10 AW30 AW40-06 VY1
0.25 0.25 G
0.25
PPA
Outlet pressure (MPa)
Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point Set point

AL
0.2 0.2 0.2

0.15

0.15 0.15
00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)

AW20 AW40
0.25 0.25
Outlet pressure (MPa)

Outlet pressure (MPa)

Set point Set point

0.2 0.2

0.15 0.15
00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 00 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa)

14-2-69
70

Series AW10 to 40
Construction
JIS Symbol

AW10 AW20 AW30/40

w
w w
t
t t
q
e q q

IN OUT IN OUT IN OUT

y y y

r e e

u r r

u u
Drain

Drain

Drain
Component Parts
Material
No. Description Note
AW10/20 AW30 AW40/40-06
q Body Zinc die-casted Aluminum die-casted Platinum silver
w Bonnet Polyacetal Black

Replacement Parts
Part no.
No. Description Material
AW10 AW20 AW30 AW40 AW40-06
Stainless steel (4) (4) (4) (4)
e Valve assembly AR10P-090S AW20P-360AS AW30P-360AS AW40P-360AS AW40P-380AS
Brass, HNBR
r Filter element Non-woven fabric AF10P-060S AF20P-060S AF30P-060S AF40P-060S AF40P-060S
t Diaphragm assembly Weatherability NBR AR10P-150AS (1) AR20P-150AS AR30P-150AS AR40P-150AS AR40P-150AS
y Bowl O-ring NBR C1SFP-260S C2SFP-260S C3SFP-260S C4SFP-260S C4SFP-260S
u Bowl assembly (2) PC C1SF C2SF C3SF (3) C4SF (3) C4SF (3)
Note 1) AW10 is a piston and a gasket (KSYP-13) type assembly.
Note 2) Including O-ring. Please contact SMC regarding the bowl assembly supply for PSI and °F unit specifications.
Note 3) Bowl assembly includes a bowl guard (steel band material).
Note 4) Assembly includes valve assembly, valve spring and stem assembly.

14-2-70
71

Filter Regulator Series AW10 to 40


Dimensions
AW10/20 T H M
N D Panel fitting dimension
J Bracket
S Y
U (Option)
W

C
IN OUT
Z

P
V
IN OUT

K
Plate thickness

B
Pressure gauge
port size AW10, AW20: Max. 3.5 F.R.L.
Pressure gauge OUT

(Option)

Square embedded type


AV
pressure gauge (Option)
O S AU
Port size
Drain
E
A Min. clearance AF

G
for maintenance
H M Panel fitting dimension AR
AW30/40 T D Y
N J
Bracket IR

W
S U (Option) IN OUT
Z
VEX
C
Q

P
Plate thickness
AMR

V
AW30: Max. 3.5
IN OUT
K

AW40: 5
ITV
B

Pressure gauge OUT


Pressure gauge (Option)
port size
IC
Square embedded type
pressure gauge (Option)
VBA
Port size
VE
Drain Min. clearance E
G

for maintenance
A VY1
G
Applicable model AW10, AW20 AW30, AW40, AW40-06
With auto-drain With auto-drain Metal bowl with Drain cock with
(N.C.) Metal bowl (N.O./N.C.) Metal bowl level gauge With drain guide barb fitting PPA
AL
Optional
B

B
B

B
B

specifications N.O.: Black


B
B

O S N.C.: Gray O

M5 x 0.8 ø10
S
1/4
One-touch Width across Barb fitting
fitting flats 17 Applicable tubing: T0604

(mm)
Accessory specifications
Standard specifications With
Model Port size With pressure gauge Bracket mounting size Panel mount auto-drain
A B C D E G H J K M N P Q S T U V W Y Z B
AW10 M5 x 0.8 25 108 48 25 28 25 26 — 0 25 28 30 4.5 6.5 40 2 18 18.5 — — 125
AW20 1/8, 1/4 40 160 73 52 40 40 63 27 5 30 34 44 5.4 15.4 55 2.3 30 28.5 14 6 177
AW30 1/4, 3/8 53 201 86 59 57 55 66 30.5 3.5 41 40 46 6.5 8 53 2.3 31 38.5 19 7 242
AW40 1/4, 3/8, 1/2 70 239 92 75 73 80 76 38.5 1.5 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 278
AW40-06 3/4 75 242 93 75 73 80 76 38.5 1.2 50 54 56 8.5 10.5 70 2.3 37 42.5 21 7 281

Optional specifications
Model With barb fitting With drain guide Metal bowl Metal bowl with level gauge
B B B B
AW10 — — 107 —
AW20 — — 160 —
AW30 209 208 214 234
AW40 247 246 252 272
AW40-06 250 249 255 275

14-2-71
72
Filter Regulator Series AR20 to 40
Made to Order Specifications:
Please contact SMC for detailed dimensions, specifications, and lead times.

1. Special Temperature Environment 2. High Pressure


Special materials are used in the manufacturing of seals and Strong materials are used in the manufacturing of air filters
resin parts to allow them to withstand various temperature intended for high pressure operation.
conditions in cold or tropical (hot) regions.
Specifications Specifications
Part no. -X430 -X440 Part no. -X425
Environment Low temperature High temperature Proof pressure 3.0 MPa
Ambient temperature –30 to 60°C –5 to 80C° Max. operating pressure 2.0 MPa
Fluid temperature –5 to 60°C (With no freezing) Set pressure range 0.1 to 1.6 MPa
Rubber parts Special NBR FPM Ambient and fluid temperature –5 to 60°C (With no freezing)
Material
Main parts Aluminum die-casted
Applicable Model
Applicable Model Model AW20 AW30 AW40 AW40-06
Model AW30 AW40 AW40-06 Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4
Port size 1/4, 3/8 1/4, 3/8, 1/2 3/4

How to Order How to Order

AW 30 F 03 BG 2 N X430 AW 30 F 03 BG 2 N X425
Filter Filter
regulator For high/low regulator For high
temperature pressure
Body size
X430 Low temperature Body size
30 40
X440 High temperature 20 30 40
Port size
Thread type
Nil Rc Thread type Port Body size
Symbol size
N (1) NPT
Port size Nil Rc 20 30 40
F (2) G Port Body size N (1) NPT 01 1/8  — —
Symbol size
Note 1) Drain guide is NPT 30 40 F (2) G 02 1/4   
1/4 (applicable to 02 1/4   Note 1) Drain guide is 03 3/8 —  
AW30 to 40) NPT 1/4
Note 2) Drain guide is G 03 3/8   04 1/2 — — 
(applicable to
1/4 (applicable to 04 1/2 —  AW30 to 40) 06 3/4 — — 
AW30 to 40). Note 2) Drain guide is G
06 3/4 — 
1/4 (applicable
Option (3) to AW30 to 40). Option (3)
Symbol Description Applicable model Symbol Description Applicable model
Nil — — Nil — —
B With bracket AW30/40 B With bracket AW20/40
G (4) With round pressure gauge (With limit indicator) AW30/40 G (4) With round pressure gauge (With limit AW20/40
H With set nut (For panel mount) AW30/40 H indicator) AW20/40
Note 3) Bracket is not assembled and is supplied loose at the time Note 3) Bracket is not assembled and is supplied loose at the
of shipment. time of shipment.
Note 4) Mounting thread for pressure gauge: 1/8 for AW30; 1/4 for Note 4) Mounting thread for pressure gauge: 1/8 for AW20 to
AW40 30; 1/4 for AW40
Pressure gauge type: G43 Pressure gauge type: G46
Bowl Bowl
Symbol Description Applicable model Symbol Description Applicable model
Nil (5) Metal bowl AW30/40 2 (5) Metal bowl AW20 to 40
Note 5) Only metal bowl available 8 (5) Metal bowl with level gauge AW30/40
Note 5) Only metal bowl or metal bowl with level
Option gauge available.
Symbol Description Applicable model
1 (6) 0.02 to 0.2 MPa setting AW30/40
J (7) Drain guide 1/4 AW30/40 Optional specifications
N Non-relieving type AW30/40 Symbol Description Applicable model
R Flow direction: Right  Left AW30/40 J (6) Drain guide 1/4 AW30/40
Name plate, caution plate for bowl, and pressure N Non-relieving type AW20 to 40
Z (8) AW30/40
gauge in imperial units (PSI, °F) R Flow direction: Right  Left AW20 to 40
∗ When more than one specification is required, indicate in ascending Z (7) Name plate, caution plate for bowl, and pressure AW20 to 40
alphanumeric order. gauge in imperial units (PSI, °F)
Note 6) The only difference from the standard specifications is the ∗ When more than one specification is required, indicate in ascending
adjusting spring for the regulator. It does not restrict the setting of alphanumeric order.
0.2 MPa or more. Note 6) Without a valve function.
Note 7) Without a valve function. Note 7) For thread type NPT.
Note 8) For thread type NPT. This product is for overseas use only This product is for overseas use only according to the new
according to the new Measurement Law. (The SI unit type is Measurement Law. (The SI unit type is provided for use in Japan.)
provided for use in Japan.)
Note 9) Please consult with SMC for detailed dimensions and available attachments and options.
Note 10) Comes with type T handle.
14-2-72
73
Filter Regulator Series AW20(K) to AW40(K)
Made to Order Specifications:
Please contact SMC for detailed dimensions, specifications, and lead times.

3. With Digital Pressure Switch


Digital pressure switch (ISE30---L) is supplied loose for mounting on pressure gauge connection port.

Specifications Applicable Model F.R.L.


Part no. suffix -X465 Model AW20(K) AW30(K) AW40(K) AW40(K)-06
Model ISE30---L Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 AV
Set pressure range (MPa) –0.1 to 1
Pressure Set and display resolution (MPa) 0.001 AU
switch 12 to 24 VDC ± 10%, Ripple (p-p) 10%
Power supply voltage
or less (With power supply polarity protection)
Power consumption 45 mA or less (70 mA or less for current output)
AF
∗ Pressure gauge port size: 1/8
AR
How to Order IR
VEX
AW 30 K F 03 B 1N X465 A
Filter AMR
regulator
Switch specifications ITV
Body size Symbol Output specifications
A NPN output
20 30 40
B PNP output
IC
C 1 to 5 V output
With back flow mechanism D 4 to 20 mA output VBA
Nil ––
K With back flow machanism With digital pressure switch VE
(Series ISE30) (7)
Thread type Note 7) Optional parts are not assembled
Nil Rc and are supplied loose at the VY1
N (1) NPT time of shipment.
Option
F (2) G
Symbol Description Applicable model
G
Note 1) Drain guide is NPT 1/4 1 (4) 0.02 to 0.2 MPa setting AW20(K) to 40(K)
(applicable to AW30 to 40),
2 Metal bowl AW20(K) to 40(K) PPA
and the exhaust port for auto-
drain comes with ø3/8" One- 6 Nylon bowl AW20(K) to 40(K)
touch fitting (applicable to 8 Metal bowl with level gauge AW30(K)/40(K) AL
AW30 to 40). C With bowl guard AW20(K)
Note 2) Drain guide is G 1/4 J (5) Drain guide 1/4 AW30(K)/40(K)
(applicable to AW30 to 40). Non-relieving type AW20(K) to 40(K)
N
R Flow direction: Right  Left AW20(K) to 40(K)
W Drain cock with barb fitting: ø6 x ø4 nylon tubing AW30(K)/40(K)
Port size Name plate and caution plate for bowl in imperial units
Z (6) AW20(K) to 40(K)
Port Body size (PSI, °F)
Symbol size
20 30 40 ∗ When more than one specification is required, indicate in ascending
01 1/8   — alphanumeric order.
02 1/4   
Note 4) The only difference from the standard specifications is the
adjusting spring for the regulator. It does not restrict the setting of
03 3/8 —   0.2 MPa or more.
04 1/2 — —  Note 5) Without a valve function.
06 3/4 — —  Note 6) For thread type NPT. This product is for overseas use only
according to the new Measurement Law. (The SI unit type is
Option (3) provided for use in Japan.)
Symbol Description Applicable model
Nil — —
B With bracket AW20(K) to 40(K)
C Float type auto-drain (N.C.) (4) AW20(K) to 40(K)
D Float type auto-drain (N.O.) (4) AW30(K)/40(K)
H With set nut (For panel mount) AW20(K) to 40(K)
Note 3) Optional parts are not assembled and are supplied loose at
the time of shipment (except options C and D).
Note 4) Applicable tubing O.D for auto drain connection should be
ø3/8" in case NPT thread port is chosen.
Note 8) Please consult with SMC for detailed dimensions and available attachments and options.
Note 9) Refer to SMC catalog CAT.ES100-42 for detailed specifications and instructions of digital pressure switch.

14-2-73
74

Filter Regulator with Back Flow Mechanism

Series AW20K/30K/40K
How to Order
AW 30 K F 03 BE 1N
Filter regulator Option
Body size Symbol Description Applicable model
1 (4) 0.02 to 0.2 MPa setting AW20K to 40K
20 30 40 2 Metal bowl AW20K to 40K
6 Nylon bowl AW20K to 40K
With back flow mechanism 8 Metal bowl with level gauge AW30K/40K
Note) AW10 comes with a back flow With bowl guard
mechanism as a standard feature.
C AW20K
J (5) Drain guide 1/4 AW30K/40K
If the set pressure is not exceeding
0.15 MPa, back flow may not occur. N Non-relieving type AW20K to 40K
When a back flow mechanism is R Flow direction: Right  Left AW20K to 40K
required with a set pressure of less W Drain cock with barb fitting: ø6 x ø4 nylon tubing AW30K/40K
AW40K than 0.15 MPa, please contact SMC. Z (6) Name plate, caution plate for bowl, and pressure gauge in imperial units (PSI, °F) AW20K to 40K
Thread type ∗ When more than one specification is required, indicate in alphanumeric order.
Note 4) The only difference from the standard specifications is the adjusting spring for
Nil Rc Port size the regulator. It does not restrict the setting of 0.2 MPa or more.
Note 5) Without a valve function.
N (1) NPT Port Body size
Symbol Note 6) For NPT thread type. This product is for overseas use only according to the new
size 20 30 40
F (2) G Measurement Law. (The SI unit type is provided for use in Japan.)
01 1/8  — —
Note 1) Drain guide is NPT Accessory (3)
1/4 (applicable to 02 1/4   
AW30K and 40K), 03 3/8 —   Symbol Description Applicable model
and the exhaust port 04 1/2 — —  Nil — —
for auto-drain comes B With bracket AW20K to 40K
06 3/4 — — 
with ø3/8" One-touch C Float type auto-drain (N.C.) (2) AW20K to 40K
fitting (applicable to
D Float type auto-drain (N.O.) (2) AW30K/40K
AW30K and AW40K).
AW20K Note 2) Drain guide is G 1/4 E With square embedded type pressure gauge (With limit indicator) AW20K to 40K
(applicable to AW30K G With round pressure gauge (With limit indicator) AW20K to 40K
and AW40K). H With set nut (For panel mount) AW20K to 40K
Note 1) Optional parts are not assembled and are supplied loose at the time
of shipment (except options C, D and E).
Note 2) Applicable tubing O.D for auto drain connection should be ø3/8" in
case NPT thread port is chosen.
Standard Specifications
Model AW20K AW30K AW40K AW40K-06
Port sizes 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4
Fluid Air
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Set pressure range (1) 0.05 to 0.85 MPa
Pressure gauge port size (2) Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 Rc, NPT, G 1/4
Relief pressure Set pressure + 0.05 MPa (at relief flow rate of 0.1l/min (ANR))
Ambient and fluid temperature –5 to 60°C (With no freezing)
Nominal filtration rating 5 µm
JIS Symbol Drain capacity (cm3) 8 25 45 45
Bowl material Polycarbonate
Bowl guard Option Standard
Construction Relieving type
Weight (kg) 0.32 0.40 0.72 0.75
Note 1) Set the inlet pressure 0.05 MPa or higher than the set pressure.
Note 2) Pressure gauge connection threads are not required for regulators with a square embedded type
pressure gauge (AW20K to AW40K).
Accessory Part No.
Applicable model
Circuit Diagram AW20K AW30K AW40K AW40K-06
Accessory
When the air supply is cut off and
releasing the inlet pressure to the Bracket assembly (1) AW20P-270AS AR30P-270AS AR40P-270AS AR40P-270AS
atmosphere, the residual pressure Set nut AR20P-260S AR30P-260S AR40P-260S AR40P-260S
release of the outlet side can be ensured Round type G36-10-01 G36-10-01 G46-10-02 G46-10-02
for a safety purpose. (2) 1.0 MPa Square (3)
Pressure embedded type GC3-10AS GC3-10AS GC3-10AS GC3-10AS
JIS Symbol gauge Round type G36-2-01 G36-2-01 G46-2-02 G46-2-02
0.2 MPa Square (3)
GC3-2AS GC3-2AS GC3-2AS GC3-2AS
embedded type
(4)
Float type N.O. — AD38 AD38N(5) AD48 AD48N(5) AD48 AD48N(5)
With back flow auto-drain N.C. AD27 AD37 AD37N(5) AD47 AD47N(5) AD47 AD47N(5)
mechanism Filter regulator Note 1) Assembly includes a bracket and set nuts. Note 3) Includes one O-ring and 2 mounting screws.
Note 2)  in part numbers for a round pressure gauge indicates a Note 4) Minimum operating pressure: N.O. type–0.1 MPa;
type of connection thread. No indication is necessary for R; N.C. type–0.1 MPa (AD27) and 0.15 MPa
however, indicate N for NPT. Please contact SMC (AD37/47). Please contact SMC regarding the
regarding the connection thread NPT and pressure gauge specifications for PSI unit and °F.
supply for PSI unit specifications. Note 5) When “N” is specified in the end of part number of
auto-drain, applicable tubing O.D should be ø3/8".
14-2-74
75

Filter Regulator with Back Flow Mechanism Series AW20K/30K/40K


Condition:
Flow Characteristics (Representative values) Inlet pressure 0.7 MPa

AW20K Rc 1/4 AW30K Rc 3/8 Precautions


0.6 0.6
Be sure to read before handling.
0.5 0.5 Refer to pages 14-21-3 to 14-21-4

Outlet pressure (MPa)


for Safety Instructions and Com-
Outlet pressure (MPa)

0.4 0.4 mon Precautions.

0.3 0.3 Mounting & Adjustment


F.R.L.
0.2 0.2 Warning
1. Set the regulator while checking the AV
0.1 0.1 displayed values of the inlet and outlet
pressure gauges. Turning the knob
0 0 excessively can cause damage to the AU
0 200 400 600 800 0 500 1000 1500
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) internal parts.
2. The pressure gauge included with AF
AW40K Rc 1/2 AW40K-06 Rc 3/4 regulators for 0.02 to 0.2 MPa setting is for
0.6 0.6 up to 0.2 MPa use. Exceeding 0.2 MPa of AR
pressure can damage the gauge.
0.5 0.5 3. Do not use tools on the pressure regulator IR
Outlet pressure (MPa)

Outlet pressure (MPa)

knob as this may cause damage. It must


0.4 0.4 be operated manually.
VEX
0.3 0.3
Caution AMR
0.2 0.2 1. Be sure to unlock the knob before
adjusting the pressure and lock it after ITV
0.1 0.1 setting the pressure.
Failure to follow this procedure can cause IC
0
0 1000 2000 3000
0
0 1000 2000 3000 4000
damage to the knob and the outlet
Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) pressure may fluctuate.
• Pull the pressure regulator knob to unlock. VBA
Conditions:
Inlet pressure 0.7 MPa
(You can visually verify this with the “orange
Outlet pressure 0.2 MPa mark” that appears in the gap.) VE
Pressure Characteristics (Representative values) Flow rate 20 l/min (ANR) • Push the pressure regulator knob to lock.
AW20K AW40K When the knob is not easily locked, turn it VY1
left and right a little and then push it (when
0.25 0.25 the knob is locked, the “orange mark”, i.e.,
the gap will disappear).
G
Set point Set point
Outlet pressure (MPa)

Outlet pressure (MPa)

PPA
0.2 0.2
Orange mark AL

0.15 0.15

0 0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa)

AW30K AW40K-06
0.25 0.25
2. A knob cover is available to prevent
Set point Set point careless operation of the knob. Refer to
Outlet pressure (MPa)

Outlet pressure (MPa)

page 14-2-6 for details.

0.2 0.2

Maintenance
Warning
0.15 0.15 1. Replace the element every 2 years or
when the pressure drop becomes 0.1
0 0 MPa, whichever comes first to prevent
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa) damage to the element.

14-2-75
76

Series AW20K/30K/40K
Working Principle

A-A w
A

Figure 1
Normal
SMC
K

U
P

SH OC
t o L

Pressure in Inlet pressure


diaphragm (IN)
chamber

A Figure 2
Figure 3 Back flow
e

q
Pressure in Inlet pressure
diaphragm (IN)
chamber

IN OUT IN OUT
(Inlet pressure) (Outlet pressure) (Inlet pressure) (Outlet pressure)

When the inlet pressure (P1) is higher than the set pressure, the check valve w closes and operates as a normal regulator (Figure 1).
When the inlet pressure (P1) is shut off and released, the check valve w, opens and the pressure in the diaphragm chamber q is released into
the inlet side (Figure 2).
This lowers the pressure in the diaphragm chamber q, and the force generated by pressure regulator spring e lifts the diaphragm. Valve r
opens through the stem, and the outlet pressure is released to the inlet side (Figure 3).

Construction
AW20K to 40K
A-A i
A

w
SMC
t
q
K

U
P

SH O C
t o L

IN OUT
A (Inlet pressure) (Outlet pressure)
Component Parts
Material y
No. Description Note
AW20K AW30K AW40K AW40K-06 e
q Body Zinc die-casted Aluminum die-casted Platinum silver
w Bonnet Polyacetal Black
r

Part no.
u
No. Description Material
AW20K AW30K AW40K AW40K-06
Stainless steel (4) (4) (4) (4)
e Valve assembly Brass, HNBR AW20P-360AS AW30P-360AS AW40P-360AS AW40P-380AS

Non-woven
r Filter element fabric AF20P-060S AF30P-060S AF40P-060S AF40P-060S

t Diaphragm assembly Weatherability NBR AR20P-150AS AR30P-150AS AR40P-150AS AR40P-150AS


y Bowl O-ring NBR C2SFP-260S C3SFP-260S C4SFP-260S C4SFP-260S
u Bowl assembly (1) PC C2SF C3SF (2) C4SF (2) C4SF (2)
i Check valve assembly (3) POM, PBT AR20KP-020AS AR20KP-020AS AR20KP-020AS AR20KP-020AS
Note 1) Including O-ring. Please contact SMC regarding the bowl assembly supply for PSI and °F unit
specifications.
Note 2) Bowl assembly includes a bowl guard (steel band material).
Note 3) Check valve assembly includes check valve cover, check valve body assembly and screws (2 pcs.).
Note 4) Assembly includes valve assembly, valve spring and stem assembly.
14-2-76
77

Filter Regulator with Back Flow Mechanism Series AW20K/30K/40K


Dimensions
AW20K/30K/40K

T H M
Panel fitting dimension
N D
Y J
S U
IN OUT Bracket
W

Q
(Option)
F.R.L.

C
Z
Plate thickness AV

P
AW20K, 30K: Max. 3.5

V
AW40K: Max. 5 IN OUT
AU

K
AF

B
Pressure gauge OUT
(Option)
Pressure gauge
port size
AR
Square embedded type
pressure gauge (Option) IR

Port size
VEX
Drain E AMR
Min. clearance

G
A for maintenance
ITV
IC
Applicable model AW20K AW30K, AW40K, AC40K-06
With auto-drain
Metal bowl
With auto-drain
Metal bowl
Metal bowl with
With drain guide
Drain cock with VBA
(N.C.) (N.O./N.C.) level gauge barb fitting

VE
Optional

B
VY1
B

B
B

specifications N.O.: Black


B
B

O S N.C.: Gray O
ø10
S
1/4
M5 x 0.8
One-touch Width across
Barb fitting
Applicable tubing:
G
fitting flats 17 T0604
PPA
AL
(mm)
Accessory specifications
Standard specifications
Model Port size With pressure gauge Bracket mounting size Panel mount With auto-drain
A B C D E G H J K M N P Q S T U V W Y Z B
AW20K 1/8, 1/4 40 160 73 52 40 40 63 27 5 30 34 44 5.4 15.4 55 2.3 30 28.5 14 6 177
AW30K 1/4, 3/8 53 201 86 59 57 55 66 30.5 3.5 41 40 46 6.5 8 53 2.3 31 38.5 19 7 242
AW40K 1/4, 3/8, 1/2 70 239 92 75 73 80 76 38.5 1.5 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 278
AW40K-06 3/4 75 242 93 75 73 80 76 38.5 1.2 50 54 56 8.5 10.5 70 2.3 37 42.5 21 7 281

Optional specifications
Model Port size With barb fitting With drain guide Metal bowl Metal bowl with level gauge
B B B B
AW20K 1/8, 1/4 — — 160 —
AW30K 1/4, 3/8 209 208 214 234
AW40K 1/4, 3/8, 1/2 247 246 252 272
AW40K-06 3/4 250 249 255 275

14-2-77
78

Mist Separator Regulator

AWM20/30/40
Series AWM is a component
made up of a regulator and a
mist separator that are
integrated to provide optimum
results in applications such as
clean-air blow operations.
JIS Symbol

AWM20
Filtration: 0.3 µm
How to Order AWM40

Option
AWM 30 F 03 BE 1N Symbol Description Applicable model
1 (4) 0.05 to 0.2 MPa setting AWM20 to 40
Mist separator 2 Metal bowl AWM20 to 40
regulator 6 Nylon bowl AWM20 to 40
Body size
8 Metal bowl with level gauge AWM30/40
20 30 40 C With bowl guard AWM20
Thread type J (5) Drain guide 1/4 AWM30/40
N Non-relieving AWM20 to 40
Nil Rc
R Flow direction: Right  Left AWM20 to 40
N (1) NPT W Drain cock with barb fitting: ø6 x ø4 nylon tubing AWM30/40
F (2) G Name plate, caution plate for bowl, and
Z (6) AWM20 to 40
Note 1) Drain guide is NPT 1/4 pressure gauge in imperial units (PSI, °F)
(applicable to AWM30
and 40), and the ∗ When more than one specification is required, indicate in alphanumeric order.
exhaust port for auto- Note 4) The only difference from the standard specifications is the adjusting spring
drain comes with ø3/8" for the regulator. It does not restrict the setting of 0.2 MPa or more.
One-touch fitting Note 5) Without a valve function.
(applicable to AWM30 Note 6) For NPT thread type. This product is for overseas use only according to the
and AWM40). new Measurement Law. (The SI unit type is provided for use in Japan.)
Accessory (3)
Note 2) Drain guide is G 1/4
(applicable to AWM30 Symbol Description Applicable model
and AWM40). Nil — —
B With bracket AWM20 to 40
Port size C Float type auto-drain (N.C.) (2) AWM20 to 40
Port Body size D Float type auto-drain (N.O.) (2) AWM30/40
Symbol
size 20 30 40 E With square embedded type pressure gauge (With limit indicator) AWM20 to 40
01 1/8  — — G With round pressure gauge (With limit indicator) AWM20 to 40
02 1/4    H With set nut (For panel mount) AWM20 to 40
03 3/8 —   Note 1) Optional parts are not assembled and are supplied loose at the time of shipment (except options C,
D and E).
04 1/2 — — 
Note 2) Applicable tubing O.D for auto-drain connection should be ø3/8" in case NPT thread port is chosen.
: Combination available : Combination not available
Accessory/Optional Specifications Combinations : Varies depending on the model : Available only with NPT thread
Applicable mist separator regulator
Symbol

Combination Accessory Optional specifications


AWM20 AWM30 to 40
Accessory/Optional specifications B C D E G H 1 2 6 8 C J N R W Z
With bracket (With set nut) B
Float type auto-drain (N.C.) C
Accessory

Float type auto-drain (N.O.) D


Square embedded type pressure gauge E
Round pressure gauge G
With set nut (For panel mount) H
0.05 to 0.2 MPa setting -1
Metal bowl -2
Optional specifications

Nylon bowl -6
Metal bowl with level gauge -8
With bowl guard -C
Drain guide 1/4 -J
Non-relieving type -N
Flow direction: Right  Left -R
Drain cock with barb fitting: ø6 x ø4 nylon tubing -W
Name plate, caution plate for bowl, and pressure
gauge in imperial units (PSI, °F) -Z

14-2-78
79

Mist Separator Regulator Series AWM20/30/40


Standard Specifications
Note 1) Pressure gauge connection threads
Model AWM20 AWM30 AWM40 are not required for the regulator
Port sizes 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 with a square embedded type
Fluid Air pressure gauge (AWM20 to 40).
Proof pressure 1.5 MPa Note 2) When the compressor oil mist
discharge concentration is 30
Maximum operating pressure 1.0 MPa mg/Nm3 (ANR).
Set pressure range 0.05 to 0.85 MPa Note 3) Bowl O-ring and other O-rings are
Pressure gauge port size (1) Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 slightly lubricated.
Note 4) When the outlet pressure is 0.5
Ambient and fluid temperature –5 to 60°C (With no freezing)
MPa. (The rated flow varies
Nominal filtration rating 0.3 µm (95% filtered particle size) depending on the set pressure.) F.R.L.
Outlet side oil mist concentration Max. 1.0 mg/m3 (ANR) (approx. 0.8 ppm) (2) (3) Keep the air flow within the rated
Rated flow (l/min (ANR)) (4) flow to prevent and outflow of a
150 330 820
lubricant to the outlet side. AV
Bowl material Polycarbonate
Bowl guard Option Standard AU
Drain capacity (cm3) 8 25 45
Construction Relieving type AF
Weight (kg) 0.44 0.59 1.25
Note) When “N” is specified in the end of part number of auto drain, applicable tubing O.D should be
ø3/8". AR
Accessory Part No. IR
Applicable model Note 1) Assembly includes a bracket and
Accessory
AWM20 AWM30 AWM40 set nuts. VEX
Note 2)  in part numbers for a round
Bracket assembly (1) AW20P-270AS AR30P-270AS AR40P-270AS pressure gauge indicates a type of
Set nut AR20P-260S AR30P-260S AR40P-260S connection thread. No indication is AMR
necessary for R; however, indicate
(2)
Round type G36-10-01 G36-10-01 G46-10-02
1.0 MPa Square embedded type (3) N for NPT. Please contact SMC
Pressure GC3-10AS GC3-10AS GC3-10AS regarding the NPT connection
ITV
gauge Round type G36-2-01 G36-2-01 G46-2-02 thread and pressure gauge supply
0.2 MPa Square embedded type (3) for PSI unit specifications. IC
GC3-2AS GC3-2AS GC3-2AS
Note 3) Includes one O-ring and 2 mounting
Float type (4) N.O. — AD38 AD38NNote) AD48 AD48NNote) screws.
auto-drain N.C. AD27 AD37 AD37NNote) AD47 AD47NNote) Note 4) Minimum operating pressure: N.O. VBA
Note) When “N” is specified in the end of part number of auto-drain, applicable tubing O.D should be type–0.1 MPa; N.C. type–0.1 MPa
(AD27) and 0.15 MPa (AD37/47).
ø3/8".
Set the pressure to allow a pressure VE
drop when the fluid flows. Please
contact SMC regarding the VY1
specifications for PSI unit and °F.

G
Precautions PPA
Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions.
AL
Selection Mounting & Adjustment
Warning Warning • Pull the pressure regulator knob to
1. Residual pressure release (outlet 1. Set the regulator while checking the unlock. (You can visually verify this with
pressure release) is not complete by displayed values of the inlet and outlet the “orange mark” that appears in the
releasing inlet pressure. Please contact pressure gauges. Turning the knob gap.)
SMC regarding residual pressure excessively can cause damage to the • Push the pressure regulator knob to
release. internal parts. lock. When the knob is not easily locked,
2. The pressure gauge included with mist turn it left and right a little and then push
Air Supply separator regulators for 0.05 to 0.2 it (when the knob is locked, the “orange
MPa setting is for up to 0.2 MPa only. mark” i.e., the gap, will disappear).
Caution Exceeding 0.2 MPa of pressure can
1. Install an air filter (Series AF) as a pre- damage the gauge.
liminary filter on the inlet side of the 3. Do not use tools on the pressure regu-
mist separator regulator to prevent pre- lator knob as this may cause damage. Orange mark
mature clogging. It must be operated manually.

Maintenance Caution
1. Be sure to unlock the knob before
Warning adjusting the pressure and lock it after
1. Replace the element every 2 years or setting the pressure.
when the pressure drop becomes 0.1 Failure to follow this procedure can
MPa, whichever comes first, to prevent cause damage to the knob and the
damage to the element. outlet pressure may fluctuate. 2. A knob cover is available to prevent
careless operation of the knob. Refer to
page 14-2-6 for details.

14-2-79
80

Series AWM20/30/40
Flow Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa

AWM20 Rc 1/4 AWM30 Rc 3/8 AWM40 Rc 1/2


Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)


Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

Pressure Characteristics Conditions: Inlet pressure 0.7 MPa; Outlet pressure 0.2 MPa; Flow rate: 20 l/min (ANR)

AWM20 AWM30 AWM40


0.25 0.25 0.25
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)


Set point Set point Set point

0.20 0.20 0.20

0.15 0.15 0.15


0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)

Construction
JIS Symbol AWM20 AWM30/40

w
t w
q t
IN OUT q
IN OUT
e
y y
r e
u r
Component Parts
u
Material
No. Description Note
AWM20 AWM30 AWM40
q Body Zinc die-casted Aluminum die-casted Platinum silver
Drain
w Bonnet Polyacetal Black

Drain
Replacement Parts
Part no.
No. Description Material
AWM20 AWM30 AWM40
e Valve assembly Brass, HNBR AWM20P-090AS AWM30P-090AS AWM40P-090AS
r Element assembly — AFM20P-060AS AFM30P-060AS AF40P-060AS
t Diaphragm assembly Weatherability NBR AR20P-150AS AR30P-150AS AR40P-150AS
y Bowl O-ring NBR C2SFP-260S C3SFP-260S C4SFP-260S
u Bowl assembly (1) PC C2SF C3SF (2) C4SF (2)
Note 1) Including O-ring. Please contact SMC regarding the bowl assembly supply for PSI and °F
unit specifications.
Note 2) Bowl assembly for AWM30 and AWM40 comes with a bowl guard (steel band material).

14-2-80
81

Mist Separator Regulator Series AWM20/30/40


Dimensions
H M
AWM20 T D
N J U Panel fitting dimension
Bracket
S (Option)
Y
W
IN OUT
Z
C

P
V
Plate thickness
IN OUT AWM20: Max. 3.5

K
F.R.L.
B

OUT

Pressure gauge
Pressure gauge (Option)
port size AV
Square embedded type
pressure gauge (Option) AU
Port size
O S
AF
Drain Min. clearance E

G
A for maintenance AR

AWM30/40 H M
IR
T D
N J U Panel fitting dimension VEX
Bracket Y
S (Option)
IN
W
OUT
AMR
Z
ITV
C

Plate thickness

P
V
IN OUT AWM30: Max. 3.5 IC
K

AWM40: Max. 5
B

Pressure gauge
Pressure gauge OUT VBA
(Option)
port size
Square embedded type VE
pressure gauge (Option)
VY1
Port size
G
Drain E
Min. clearance
G

A for maintenance PPA


Applicable model AWM20 AWM30, AWM40 AL
With auto-drain With auto-drain Metal bowl with Drain cock with
(N.C.) Metal bowl (N.O./N.C.) Metal bowl level gauge With drain guide barb fitting

Optional
B

B
B

B
B

specifications N.O.: Black


B
B

O S N.C.: Gray O

M5 x 0.8 ø10
S
1/4
One-touch Width across Barb fitting
fitting flats 17 Applicable tubing: T0604

(mm)
Accessory specifications
Standard specifications With
Model Port size With pressure gauge Bracket mounting size Panel mount auto-drain
A B C D E G H J K M N P Q S T U V W Y Z B
AWM20 1/8, 1/4 40 173 73 52 40 45 63 27 5 30 34 44 5.4 15.4 55 2.3 30 28.5 14 6 190
AWM30 1/4, 3/8 53 201 86 59 57 50 66 30.5 3.5 41 40 46 6.5 8 53 2.3 31 38.5 19 7 242
AWM40 1/4, 3/8, 1/2 70 239 92 75 73 70 76 38.5 1.5 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 278

Optional specifications
Model With barb fitting With drain guide Metal bowl Metal bowl with level gauge
B B B B
AWM20 — — 173 —
AWM30 209 208 214 234
AWM40 247 246 252 272

14-2-81
82

Micro Mist Separator Regulator

Series AWD20/30/40
Series AWD is a component
made up of a regulator and a
micro-mist separator that are
integrated to provide optimum JIS Symbol
results in applications such as
ultraclean air blow operations.

AWD20
Filtration: 0.01 µm AWD40
How to Order
Option
AWD 30 F 03 BE 1N Symbol Description Applicable model
1 (4) 0.05 to 0.2 MPa setting AWD20 to 40

Micro mist 2 Metal bowl AWD20 to 40


separator 6 Nylon bowl AWD20 to 40
regulator 8 Metal bowl with level gauge AWD30/40
C With bowl guard AWD20
J (5) Drain guide 1/4 AWD30/40
Body size N Non-relieving AWD20 to 40
20 30 40 R Flow direction: Right  Left AWD20 to 40
W Drain cock with barb fitting: ø6 x ø4 nylon tubing AWD30/40
Thread type Z (6) Name plate, caution plate for bowl, and pressure gauge in imperial units (PSI, °F) AWD20 to 40
Nil Rc ∗ When more than one specification is required, indicate in alphanumeric order.
N (1) NPT Note 4) The only difference from the standard specifications is the adjusting spring for
the regulator. It does not restrict the setting of 0.2 MPa or more.
F (2) G Note 5) Without a valve function.
Note 1) Drain guide is for NPT 1/4 Note 6) For NPT thread type. This product is for overseas use only according to the
(applicable to AWD30 and AWD40), new Measurement Law. (The SI unit type is provided for use in Japan.)
and the exhaust port for auto-drain
comes with ø3/8" One-touch fitting Accessory (3)
(applicable to AWD30 and AWD40). Symbol Description Applicable model
Note 2) Drain guide is G 1/4 (applicable to Nil — —
AWD30 and AWD40).
B With bracket AWD20 to 40
Port size C Float type auto-drain (N.C.) (4) AWD20 to 40
Port Body size D Float type auto-drain (N.O.) (4) AWD30/40
Symbol size E With square embedded type pressure gauge (With limit indicator) AWD20 to 40
20 30 40
01 1/8  — — G With round pressure gauge (With limit indicator) AWD20 to 40

02 1/4    H With set nut (For panel mount) AWD20 to 40


Note 3) Optional parts are not assembled and are supplied loose at the time of shipment (except
03 3/8 —   options C, D and E).
04 2/1 — —  Note 4) Applicable tubing O.D for auto-drain connection should be ø3/8" in case NPT thread port is
chosen.

: Combination available : Combination not available


Accessory/Optional Specification Combinations : Varies depending on the model : Available only with NPT thread
Applicable micro mist
Symbol

Combination Accessory Optional specifications separator regulator

Accessory/Optional specifications B C D E G H 1 2 6 8 C J N R W Z AWD20 AWD30 to 40


With bracket (With set nut) B
Float type auto-drain (N.C.) C
Accessory

Float type auto-drain (N.O.) D


Square embedded type pressure gauge E
Round pressure gauge G
Panel mount (With set nut) H
0.05 to 0.2 MPa setting -1
Metal bowl -2
Optional specifications

Nylon bowl -6
Metal bowl with level gauge -8
With bowl guard -C
Drain guide 1/4 -J
Non-relieving type -N
Flow direction: Right  Left -R
Drain cock with barb fitting: ø6 x ø4 nylon tubing -W
Name plate, caution plate for bowl, and pressure
gauge in imperial units (PSI, °F) -Z

14-2-82
83

Micro Mist Separator Regulator Series AWD20/30/40


Standard Specifications
Note 1) Pressure gauge connection threads
Model AWD20 AWD30 AWD40
are not required for the regulator
Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 with a square embedded type
Fluid Air pressure gauge (AWD20 to 40).
Proof pressure 1.5 MPa Note 2) When the compressor oil mist
discharge concentration is 30 mg/m3
Maximum operating pressure 1.0 MPa (ANR).
Set pressure range 0.05 to 0.85 MPa Note 3) Bowl O-ring and other O-rings are
Pressure gauge port size (1) Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 slightly lubricated.
Ambient and fluid temperature Note 4) When the outlet pressure is 0.5
–5 to 60°C (With no freezing)
MPa. (The rated flow varies
Nominal filtration rating 0.01µm (95% filtered particle size) depending on the set pressure.) F.R.L.
Outlet side Max. 0.1 mg/m3 (ANR) (2) (3) Keep the air flow within the rated
oil mist concentration (Before saturated with hydraulic fluid: 0.01 mg/m3 (ANR) or less, approx. 0.008 ppm ) flow to prevent an outflow of
(4) lubricant to the outlet side. AV
Rated flow (l/min (ANR)) 90 180 450
Bowl material Polycarbonate
Bowl guard
AU
Option Standard
Drain capacity (cm3) 8 25 45
Construction Relieving type
AF
Weight (kg) 0.44 0.59 1.25
AR

Accessory part no. IR


Note 1) Assembly includes a bracket and set
Applicable model
AWD20 AWD30 AWD40 nuts. VEX
Accessory Note 2)  in part numbers for a round
Bracket assembly (1) pressure gauge indicates a type of
AW20P-270AS AR30P-270AS AR40P-270AS AMR
connection thread. No indication is
Set nut AR20P-260S AR30P-260S AR40P-260S necessary for R; however, indicate N
for NPT. Please contact SMC
(2) 1.0 MPa
Round
(3)
G36-10-01 G36-10-01 G46-10-02
regarding the NPT connection thread ITV
Pressure Square embedded type GC3-10AS GC3-10AS GC3-10AS and pressure gauge supply for PSI
gauge Round G36-2-01 G36-2-01 G46-2-02 unit specifications. IC
0.2 MPa (3)
GC3-2AS GC3-2AS GC3-2AS
Note 3) Includes one O-ring and 2 mounting
Square embedded type screws.
Float type (4) N.O. — AD38 AD38N Note) AD48 AD48N Note) Note 4) Minimum operating pressure: N.O. VBA
auto-drain AD27 AD37 AD37N Note) AD47 AD47N Note) type–0.1 MPa; N.C. type–0.1 MPa
N.C.
(AD27) and 0.15 MPa (AD37/47). Set
Note) When “N” is specified in the end of part number of auto drain, applicable tubing O.D should be the pressure to allow a pressure drop VE
ø3/8". when the fluid flows. Please contact
SMC regarding the specifications for VY1
PSI unit and °F.

G
Precautions PPA
Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions. AL
Selection Mounting & Adjustment
Warning Warning • Pull the pressure regulator knob to unlock.
1. Residual pressure release (outlet 1. Set the regulator while checking the (You can visually verify this with the
pressure release) is not complete by displayed values of the inlet and outlet “orange mark” that appears in the gap.)
releasing inlet pressure. Please contact pressure gauges. Turning the knob • Push the pressure regulator knob to lock.
SMC regarding the residual pressure excessively can cause damage to the When the knob is not easily locked, turn it
release. internal parts. left and right a little and then push it (when
2. The pressure gauge included with micro the knob is locked, the “orange mark” will
Air Supply mist separator regulator for 0.05 to 0.2 disappear).

Caution MPa setting is for up to 0.2 MPa only.


Exceeding 0.2 MPa of pressure can
1. Install an air filter (Series AFM) as a damage the gauge.
preliminary filter on the inlet side of the Orange mark
3. Do not use tools on the pressure regulator
micro-mist separator to prevent
knob as this may cause damage. It must
premature clogging.
be operated manually.

Maintenance Caution
1. Be sure to unlock the knob before
Warning adjusting the pressure and lock it after
1. Replace the element every 2 years or setting the pressure.
when the pressure drop becomes 0.1 Failure to follow this procedure can
MPa, whichever comes first, to prevent cause damage to the knob and the 2. A knob cover is available to prevent
damage to the element. outlet pressure may fluctuate. careless operation of the knob. Refer to
page 14-2-6 details.

14-2-83
84

Series AWD20/30/40
Flow Characteristics (Representative value) Condition: Inlet pressure 0.7 MPa

AWD20 Rc 1/4 AWD30 Rc 3/8 AWD40 Rc 1/2

Outlet pressure (MPa)


Outlet pressure (MPa)
Outlet pressure (MPa)

Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR))

Pressure Characteristics (Representative value) Conditions: Inlet pressure 0.7 MPa; Outlet pressure 0.2 MPa; Flow rate: 20 l/min (ANR)

AWD20 AWD30 AWD40


0.25 0.25 0.25

Outlet pressure (MPa)


Outlet pressure (MPa)
Outlet pressure (MPa)

Set point Set point Set point

0.20 0.20 0.20

0.15 0.15 0.15


0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)

Construction
AWD20 AWD30/40
JIS Symbol
w w
t t
q q
IN OUT IN OUT
e
y y
r e
u r
u

Component Parts Drain

Material
No. Description Note
AWD20 AWD30 AWD40
q Body Zinc die-casted Aluminum die-casted Platinum silver Drain
w Bonnet Polyacetal Black

Replacement Parts
Part no.
No. Description Material
AWD20 AWD30 AWD40
e Valve assembly Brass, HNBR AWM20P-090AS AWM30P-090AS AWM40P-090AS
r Element assembly — AFD20P-060AS AFD30P-060AS AFD40P-060AS
t Diaphragm assembly Weatherability NBR AR20P-150AS AR30P-150AS AR40P-150AS
y Bowl O-ring NBR C2SFP-260S C3SFP-260S C4SFP-260S
u Bowl assembly (1) PC C2SF C3SF (2) C4SF (2)
Note 1) Including O-ring. Please contact SMC regarding the bowl assembly supply for PSI and °F unit
specifications.
Note 2) Bowl assembly for AWD30 and AWD40 comes with a bowl guard (steel band material).

14-2-84
85

Micro Mist Separator Regulator Series AWD20/30/40


Dimensions
AWD20
H M
T D
N J U
Panel fitting dimension
Bracket
S (Option) Y
W
IN OUT
Z
C

P
V
Plate thickness
IN OUT F.R.L.

K
AWD20: Max. 3.5
B

AV
OUT

Pressure gauge Pressure gauge


port size (Option)

Square embedded type


pressure gauge (Option)
AU

O S
Port size AF
Drain Min. clearance E
AR

G
A for maintenance

IR
H M
AWD30/40 T D
N J
U Panel fitting dimension VEX
Bracket
Y
S (Option)
IN
W
OUT
AMR
Z
ITV
C

Plate thickness

P
V
IN OUT AWD30: Max. 3.5 IC
K

AWD40: Max. 5
B

Pressure gauge
(Option)
OUT
VBA
Pressure gauge
port size
Square embedded type
pressure gauge (Option) VE
Port size VY1
Drain Min. clearance E G
G

A for maintenance
PPA
Applicable model AFD20 AWD30, AWD40
With auto-drain With auto-drain Metal bowl with Drain cock with
AL
(N.C.) Metal bowl (N.O./N.C.) Metal bowl level gauge With drain guide barb fitting

Optional
B

B
B

B
B

specifications N.O.: Black


B
B

O S N.C.: Gray O

M5 x 0.8 ø10
S
1/4
One-touch Width across Barb fitting
fitting flats 17 Applicable tubing: T0604

(mm)
Standard specifications Accessory specifications
With pressure gauge With
Model Port size Bracket mounting size Panel mount auto-drain
A B C D E G
H J K M N P Q S T U V W Y Z B
AWD20 1/8, 1/4 40 173 73 52 40 45 63 27 5 30 34 44 5.4 15.4 55 2.3 30 28.5 14 6 190
AWD30 1/4, 3/8 53 201 86 59 57 50 66 30.5 3.5 41 40 46 6.5 8 53 2.3 31 38.5 19 7 242
AWD40 1/4, 3/8, 1/2 70 239 92 75 73 70 76 38.5 1.5 50 54 54 8.5 10.5 70 2.3 35.5 42.5 21 7 278

Optional specifications
Model With barb fitting With drain guide Metal bowl Metal bowl with level gauge
B B B B
AWD20 — — 173 —
AWD30 209 208 214 234
AWD40 247 246 252 272

14-2-85

You might also like