first describes an example of the typical 3) SDH Interface Equipment (SIE): Equipment
configuration of a submarine communications that interfaces with a terrestrial SDH
system, followed by the features and functions of network.
the FLASHWAVE S650. Then it explains the 4) Submarine cable and submersible equip-
configuration of the equipment in detail. ment: Submarine repeaters that use a high
reliability optical amplifier and gain equal-
2. Configuration of submarine ization equipment to rectify the wavelength
communications system dependability of gain via a multi-stage con-
Figure 1 shows an example of the typical nection of optical fibers and repeaters.
configuration of a submarine communications
system. This system is composed of various kinds 3. Features and functions of
of equipment like SLTE and SSE, and the follow- FLASHWAVE S650
ing equipment described below. The FLASHWAVE S650 enables significant-
1) Power Feeding Equipment (PFE): Power ly improved maintainability compared with
supply equipment that supplies electric conventional equipment, while attaining a global-
power to such submersible equipment as ly high level of transmission capability using the
submarine repeaters. technology shown below.
2) Cable Termination Unit (CTU): Cable termi- Table 1 lists the main specifications of this
nation equipment that connects terrestrial product. Moreover, the following describes the
cable to submarine cable. functions of this equipment in detail.
Submarine Line Terminal Equipment Submerged Segment Submarine Line Terminal Equipment
(FLASHWAVE S650) (FLASHWAVE S650)
STM-64
SIE #1 SIE
TRIB WDM CTU CTU WDM TRIB
10.709G
× n -wave Submarine Cable
Wavelength Submarine
multiplexing Repeater
STM-64
#n PFE PFE
LAN LAN
SSE SSE
Router Router
Figure 1
Typical Configuration of submarine communications system.
footprint of the device can also be dramatically from submersible equipment through transmis-
reduced when compared to devices using the sion using a similar method.
conventional DCF and optical amplifier combina-
tion setup, thus allowing a reduction in 3.6 System surveillance and control
installation area to less than half of that of equiv- Surveillance and control of this product are
alent competitive systems. possible in a private network in combination with
SSE. The SSE enables management of the cable-
3.4 Pre-emphasis setting laying route by displaying a map (a clickable map)
The loss and gain of optical fiber in a trans- that visualizes via GUI where each unit has been
mission route, as in the case of submarine optical installed, thus providing the ability to control not
fiber cable and the optical amplifier of submarine only the SLTE at the same location, but also the
repeaters, have a respective dependency on wave- submersible equipment and power feeding equip-
length. Moreover, when each wavelength is output ment of the submarine transmission system. In
at the same level from the transmission side, the this way, the entire submarine communications
input level on the reception side is not uniform, system can be controlled.
thus causing a difference in transmission level Moreover, connecting a PC to the connector
between transmission and reception, even if wave- from the COmmon Management (COM) sub-rack
lengths are sent at the same level. Therefore, and running the surveillance control terminal
without adjustment, transmission quality would (Craft Terminal) allows isolated use of the SLTE
be different for every wavelength. to enable access of most security and control items
This product utilizes pre-emphasis technol- through a simple interface.
ogy to enable the output level of each wavelength
to be adjusted with regard to the wavelength 3.7 Safety measures
dependency of a transmission frequency. Moreover, In order to even out a maximum signal level
Fujitsu managed to achieve this pre-emphasis of 100 or more waves, the wavelength multiplex-
control automatically. In other words, adjusting er for the output level of this product’s optical
the output level for each wave from the transmis- amplifier is set to more than +20 dBm (100 mW).
sion side to comply with the margin of Moreover, the excitation light supplied to the op-
transmission quality calculated by FEC from the tical amplifier is also at a high output level of
monitor value of the error correction level on the +18 to +23 dBm, which can be dangerous to the
reception side, and allowing for automatic adjust- human body when output directly. Therefore, this
ment of output level on the transmission side equipment is compliant with international safety
ensures the uniform transmission quality of each standard IEC60825, provides Automatic Power
wavelength. Reduction (APR) capability should the output ex-
ceed +10 dBm, and also includes safety features
3.5 Surveillance and control of submarine that automatically decrease output to less than
equipment +10 dBm, such in cases where the optical fiber be-
A command signal can be modulated and comes detached.
transmitted to such submersible equipment as
submarine repeaters and gain equalizers through 3.8 Redundant configuration
the conversion of a multiplexed output signal and As for the tributary section that consists of
in a range that will not affect the transmission individual units separated by wavelength, up to
characteristics. 20 waves along with a single spare wave to the
Moreover, response signals can be received system wave can be allocated and switched by
using an optical switch employing the <N+1>/ ity to be realized. Moreover, all transmission char-
<N:1> setup, or can allow the switching of indi- acteristics can be maintained individually, even
vidual units that use a single spare wave with the when a redundant light source fails in a broad-
same wavelength for a redundant <1+1> setup. band amplifier.
With a <N+1> setup, the wavelength of the re-
serve system that is not usually used can be 4. Installation setting for
utilized to carry extra traffic. FLASHWAVE S650
In the wavelength multiplexing section that 4.1 Sub-rack configuration
collectively processes the main signals, the unit Figure 2 shows a block diagram of the basic
containing the optical parts is separated from the configuration for the <N+1>/<N:1> setup of the
control function component that is directly FLASHWAVE S650. Figure 3 shows the front
related to the transmission characteristics. This view of this basic configuration.
redundant configuration enables a higher reliabil- The main functions of this equipment are
This equipment utilizes the latest optical- tions by using the Full Band Tunable laser are
communications technology, including Fujitsu’s planned for implementation in the future.
original technology, to realize transmission
characteristics that are of the highest level in the Reference
world. By employing a flexible setup, this equip- 1) M. Shirasaki et al.: Compensation of chromatic
dispersion and dispersion slope using a virtually
ment can be used in upgrade projects, as well as imaged phased array. OFC2002, Paper TuS1,
to construct new submarine communication March 2002.