LS, LSV
Long-coupled split-case pump
50 Hz
LS, LSV
1. Product introduction 3
Table of contents
2. Applications 4
4. Performance range 7
5. Product range 8
Pump configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Pump range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6. Identification 10
Nameplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Type key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Shaft seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
7. Construction 13
Material specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Mechanical construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
8. Operating conditions 29
Pumped liquids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Ambient temperature and altitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Pressures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Flow rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Sound pressure level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Maximum particle size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
11. Accessories 96
Cyclone separator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
2
LS, LSV
1
1. Product introduction
Product introduction
Grundfos long-coupled, split-case, double inlet pumps
are non-self priming, centrifugal volute pumps. It is
available in two main designs: single-stage and
double-stage, horizontal installation type LS and
vertical installation type LSV. The pumps are energy-
efficient. Hydraulic parts are designed using
computational fluid dynamics (CFD). The
compensated double-volute design virtually eliminates
radial forces on the shaft and ensures smooth
performance throughout the entire operating range.
LS, LSV pumps are easy to install owing to the in-line
design, meaning that inlet and outlet ports are in a
straight line. The split-case construction enables
removal and dismantling of the internal pump parts,
such as bearings, wear rings, impeller and shaft seal,
without disturbing the motor or pipework.
Flanges are in accordance with DIN standards.
3
2 LS, LSV
2. Applications
Applications
LS, LSV pumps are used in these main fields of Irrigation covers these applications
application: • Field irrigation (flooding)
Commercial systems • sprinkler irrigation and drip-feed irrigation
• Air conditioning, primary and secondary chilled • aquafarming.
water systems
• water condensing systems and cooling towers
• high-rise buildings
• district heating plants and heating systems
• swimming pools
• fountains.
Industrial systems
• Process cooling and chilled water systems
GR2910
• water condensing systems and cooling towers
• industrial heating systems
• wash down and cleaning systems Fig. 6 LS, LSV pump in sprinkler irrigation
• industrial processing systems (water, light
chemicals, oils, etc.).
Water distribution
• Public waterworks
• non-potable water systems
• irrigation and aquaculture.
4
LS, LSV
3
5
3 LS, LSV
6
LS, LSV
H [m]
250
200
LS
/LS
14 V2
50 5 LS/L LS/L
rpm 0-20 SV SV
150 LS/L
0-5
75
500
-30 145 50
x2 145 0-6 0 rp 0-300-7
290 SV 12 0 rp 80 m 1
0 rp 5-1 LS m 0
m 00-3 /LS
05 14 V2
50 0
120 LS
rpm 0-15
0-4
/LS 75 LS/L
LS/L 14 V1 x2 LS/L
SV 50 5 LS 145 SV 350 145 SV 600
0 rp -50
100 125
-10
rpm 0-12 1 /LSV 2
5-4 450 00-1 0 rp
m
-25
0-6 m 0-6
0 -2 1 rp 5 3 10
290 5x2 m 0 -50 LS/L 0
0 rp 7L9S 8 SV
m /LS
V1 980 250
-20 L S /LS
LS/L
25 rpm 0-5 LS/L V SV
80 14 -10 75x LS LS 500 9 80 rp 700
4. Performance range
50 145 SV 50 -50
0-3 2 /LS 145 /LSV 3 0 rp 0-3 -40
0-5 m 0-8
LS/L
S
rpm 7 0 145 V 30
0-2 0 rp 5 0 m 00-5 3 0 50
x2 LS/L 0 rp
m LS/L m -25 08
4
290 V 100
0 rp -80 SV2
00-4
89 S V5
0-4 LS/LS
98 5 0 rp
LS/L
SV
m -24 145
0 0 0 9 8 0 0 0
V5
0 0 L S m 9 7
1 rpm -15
0-4 rpm -30
0 9
/LS
V
80 rp 00-5
LS/L 83
LS/L
SV -7 10
980 -350-7
rpm 02 8 0 rp 6 m 0 0-72
60 LS/L SV2 145 300 LS/L
SV m 00-400 5
S 980 00- 0 rp -20 -72
2
290 V 65-5 rpm 150
-47 m 0-4
50 980
500
-30
LS/L
SV
LS/L
1 LS/L LS/L
0 rp 0-2 5x2 0-6 SV SV SV
m 41 rpm 80 145 500 500 450 rpm
-4 L LS 9 8 12
LS/L 0 rpm
-30
0-4 S /LS / L LS/L 595 00-80
50 LS S V L
LS/L 9 0 LS/L 00-458 9 8 V 7
SV 80 rpm 00-600
8 -6 S V rpm 0-1
145 S/L 9 SV 0 rp 00-5 00 83 5 120 075
/LS 0 rp 150-1 SV L
980 SV 50
0-3 8 0 6 m 0 0-6 - 6 L S/L 95 0-80
14 V1 m 25-3 145 200
-1
S/L
S
rpm 5 0 rpm 00-50 67
00
- 6 S V
rpm 0 -1
50 5 05 rp 0 50-3 145 V -6 08 0 980 67 740 100 080
rpm 0-12 m 8 1 0 300
-2 L S LS/L -610 rp rp 0-7
5-4 rpm 50-3 /LS
V SV m m 00-8
15 81
LS/L 1 4 50 rp 5 00-4 7 0 0-5 15
40 x2 145 SV 4 980
LS/L 0 rp 5 m 00-4 rpm LS 00-5 LS
SV LS/L
SV m 0-350-3 23 /LS 85 /
145 100
-80 LS/L 9 V7 74 LSV
0 rp -35 LS/L 145 250
-20 LS/L LS/L7 740 0r 1
m 6 SV1 145 SV 1
0 2 5
0 rp
m 0 -3 S V S V
rpm 00-500
-7 pm 000
980 2 rpm -10
0-3 81 980 5 500 LS/L 25 -70
rpm 5-100 81 rpm 00-300 LS -40 SV 0-7
-37 LS -50 0-5 700
0x2 8F 500 30 740 -50 LS/L 70
145 /LSV -4 98 rpm LS SV
5
30 LS/L
SV LS/L 0rp
m
350 980 0-6
67 /LS 800
-6
145 6 5-5 SV - 3 00-
rpm 00-490 rpm
8C V 80 7 40 rp 0 0-6
3 8
-30
0 rp
m
0-3
30 1 450 0 0-2 3 5 2 74 0 - m 3 LS
05
rpm 50-3 LS/L 0 r 600 /LS
05
05 LS/L pm -66
05
980 SV 50 SV 7 V1
05
LS/L
0-3
rpm 0-3 60 59 000
79
00-4 740SV 70 -
0-3
980 0-500 5r
-4
00-3
90 rpm 0-5 rp m pm 700-
0-3
98
1
-15
00-5 81
0-2
5
m
85
m
-15
-20
LS
m
25-1
20 LS/L
SV
200
S
-10
LS/L LS/L V LS/L /LS
5
0 rp 50-125
m
0 rp
SV
/L
200
980 500 SV 95 V1
145 SV 10 9 8 5 0 rp m -4 7 r 0
250
V1
0-8
0 rp
0 rp 0-4 00-5 pm
m
0 rp 00-4 00
SV
m 0-2 m
125
L
S
00-4 00-6
145
41 58 595 rp -70
0 rp
SV
145
23 m 67
V
0-7
SV
LS/L
145
/L
70
0 rp
SV
0 rp
LS/L
LS/L
S
LS
145
65-5
LS/L
0 9 8 SV /
/LS
145 -2 4 LS/L L
L
15 0 rp
m 41 0 rp
m
50-3 SV SV
145
LS/L
145
50-3 740 600 80
LS
97 rpm -50 59 0-6
0-4 5r
98 pm 00
-68
3
52
10
05
05
79
0-3
05
05
0-3
0-3
0-2
00-3
-30
0-3
5-3
0
2
-25
-20
350
25-1
0-1
25-1
rpm
300
250
1
SV
rpm
SV1
SV
LS/L LS/L
SV
SV
980
SV SV
rpm
rpm
SV
65-5 100
rpm
LS/L
980
rpm
rpm 00-15
0-2 -80
LS/L
980 41 980 -24
1
LS/L
LS/L
rpm rpm
LS/L
980
980
LS/L
LS/L
980
980 SV 15
980
5
1 x 10 2 3 4 5 6 7 8 1 x 1001.5 2 3 4 5 7 1 x 1000 1.5 2 3 4 6 8 1 x 10000 1.5
3
Q [m/h]
7
Performance range
4
5 LS, LSV
5. Product range
Product range
8
LS, LSV
5
Product range
LS standard LSV standard construction LS optional
Number of poles
Pump type Design construction type1) type1) construction type1)
2 4 6 8 10 1 2 5 14 15 6 7 8 9 16 17 10 11 12 13
LS, LSV 65-50-241 ● ● Single-stage ● ● ●
LS, LSV 65-50-330 ● Single-stage ● ● ●
LS, LSV 100-80-241 ● ● Single-stage ● ● ●
LS, LSV 100-80-356 ● Single-stage ● ● ●
LS, LSV 125-100-279 ● ● Single-stage ● ● ●
LS, LSV 125-100-305 ● ● Single-stage ● ● ●
LS, LSV 125-100-381 ● Single-stage ● ● ●
LS, LSV 150-125-305 ● Single-stage ● ● ●
LS, LSV 150-125-381 ● ● Single-stage ● ● ●
LS, LSV 200-150-305 ● ● Single-stage ● ● ●
LS, LSV 200-150-381 ● ● Single-stage ● ● ●
LS, LSV 200-150-4832) ● ● Single-stage ● ● ● ● ●
LS, LSV 200-150-508 ● ● Single-stage ● ● ● ● ●
LS, LSV 250-200-305 ● ● Single-stage ● ● ●
LS, LSV 250-200-381 ● ● Single-stage ● ● ●
LS, LSV 300-200-450 ● ● Single-stage ● ● ● ● ● ●
LS, LSV 300-200-489 ● ● Single-stage ● ● ● ● ● ●
LS, LSV 300-250-305 ● ● Single-stage ● ● ●
LS, LSV 300-250-381 ● ● Single-stage ● ● ● ●
LS, LSV 350-250-498 ● ● Single-stage ● ● ● ● ● ●
LS, LSV 350-250-630 ● ● Single-stage ● ● ● ● ● ●
LS, LSV 350-300-508 ● ● Single-stage ● ● ● ● ● ●
LS, LSV 350-300-352 ● ● Single-stage ● ● ●
LS, LSV 500-300-490 ● ● Single-stage ● ●
LS, LSV 500-300-508 ● ● Single-stage ● ●
LS, LSV 500-300-710 ● ● Single-stage ● ●
LS, LSV 500-300-680 ● ● Single-stage ● ●
LS, LSV 450-350-397 ● ● Single-stage ● ● ● ● ●
LS, LSV 500-350-608 ● Single-stage ● ●
LS, LSV 500-350-702 ● Single-stage ● ●
LS, LSV 500-400-423 ● ● Single-stage ● ● ● ● ● ●
LS, LSV 500-400-458 ● ● ● Single-stage ● ● ● ● ● ●
LS, LSV 500-400-530 ● ● ● Single-stage ● ●
LS, LSV 500-400-498 ● Single-stage ● ●
LS, LSV 600-400-722 ● Single-stage ● ●
LS, LSV 600-500-498 ● ● ● Single-stage ● ● ● ● ● ●
LS, LSV 600-500-610 ● ● ● Single-stage ● ●
LS, LSV 700-500-667 ● ● ● Single-stage ● ●
LS, LSV 700-500-725 ● ● ● Single-stage ● ●
LS, LSV 700-500-585 ● ● Single-stage ● ●
LS, LSV 800-600-683 ● ● ● Single-stage ● ●
LS, LSV 800-600-667 ● ● ● Single-stage ● ●
LS, LSV 1000-700-815 ● ● Single-stage ● ●
LS, LSV 1000-700-770 ● ● Single-stage ● ●
LS, LSV 1200-800-1075 ● Single-stage ● ●
LS, LSV 1200-800-1080 ● Single-stage ● ●
LS, LSV 125-100-370 x2 ● ● Double-stage ● ●
LS, LSV 150-125-415 x2 ● ● Double-stage ● ●
LS, LSV 200-150-475 x2 ● ● Double-stage ● ●
LS, LSV 250-200-575 x2 ● ● Double-stage ● ●
1) For further information on the construction types, see section 7. Construction.
2)
This model is available in two different construction types due to the different motor power range.
9
6 LS, LSV
6. Identification
Identification
Nameplate
The nameplate on the pump gives the details of the
Pos. Description
pump.
1 Product number
2 Serial number
3 Type designation (see Type key on page 10)
1 P/N: SER#: 2 4 Rated flow rate [m 3/h]
3 Type:
5 Pump head at rated flow rate [m]
4 Q: m3/h H: m 5 6 Speed of rotation [rpm]
6 n: r/min IMP DIA: mm 7
7 Impeller diameter [mm]
8 ST: EDU°CMAX P: kW 9
Type key
Example LS(V) 125 -100 -305x /273.1 ,(W) 1 F1 D S BAQE 1
Type range
LS: Horizontal version
LSV: Vertical version
Nominal diameter of inlet port (DN)
Nominal diameter of outlet port (DN)
Maximum impeller diameter [mm]
If suffix "x" is used, the impeller or construction design is different, e.g. A, B, C,...Z
If suffix "x2" is used, the impeller is a double-stage impeller.
Actual impeller diameter [mm]
Drink water code (optional)
ACS or WARS certified pump
Pump variant
1: Basic version, grease-lubrication, pump with motor and common base frame, standard coupling
2: Grease-lubrication, bare shaft pump with common base frame, standard coupling
3: Grease-lubrication, bare shaft pump
4: Grease-lubrication, pump with motor and separate base frames, spacer coupling
5: Grease-lubrication, bare shaft pump with separate base frame, spacer coupling
6: Oil-lubrication, pump with motor and common base frame, standard coupling
7: Oil-lubrication, bare shaft pump with common base frame, standard coupling
8: Oil-lubrication, bare shaft pump
9: Oil-lubrication, pump with motor and separate base frames, spacer coupling
A: Oil-lubrication, bare shaft pump with separate base frame, spacer coupling
X: Special variant
Pipe connection
F1: 10 bar, DIN PN 10 G1: 10 bar, ANSI 125LB/150LB
F2: 16 bar, DIN PN 16 G2: 16 bar, ANSI 250LB/300LB
F3: 25 bar, DIN PN 25 G3: 25 bar, ANSI 250LB/300LB
XX: Special flange
Materials, shaft and sleeve (optional)
D: SS420 and no sleeve B: SS420 and bronze
E: SS304 and no sleeve A: SS420 and SS304
J: SS316 and no sleeve C: SS420 and SS316
L: Duplex stainless steel and no sleeve K: Duplex stainless steel and duplex stainless steel
X: Special
10
LS, LSV
6
Identification
Example LS(V) 125 -100 -305x /273.1 ,(W) 1 F1 D S BAQE 1
Note:
1. Carbon*: antimony, not approved for potable water.
2. Carbon: resin-impregnated, approved for potable water.
11
6 LS, LSV
Shaft seal
Identification
12
LS, LSV
7
7. Construction
Construction
LS pump, standard construction type 1
54c
54e
113d
67b
11a
113e
54
6b
195
113c
54c 113g
54e
11a
54
58a
113d
113e
114b
114
45
TM07 1144 1118
6b 49 24 51 109 113
13
7 LS, LSV
11b
54g
11a
113d
54e
54c
54
113f
113d 54 124 113f 79 116b 109 116c 47c 45 17 49 45 116 11 32 6a 105 51 124 53 113c 11a
116a
54e
113g
54c
TM07 1156 1118
14
LS, LSV
7
LS pump, standard construction type 15
Construction
113d 54 113 116b 106 108 47d 6a 51 45 49 45 17 116 49 116c 32 116e 105 116a 53 113c 11a
54e
54c
123
113f
113g
113e
15
7 LS, LSV
11a
10a
10b
7
11a
113e
113c
116a
54d
106
53
76
79
107
124
108
17
105
30b
116c
47c
47d
6a
66
11
49
65
54
51
109 6b
113d
24
90
TM07 1148 1118
45
Fig. 21 Sectional drawing, standard construction type 6, motor frame size is up to 250
16
LS, LSV
7
LSV pump, standard construction type 7
Construction
1a
10b 10a
7
11a
90f
113c
90e
113e 54d
116a
53
90d
106
79
76
107 124
108
17
105
30b
116c
47c
47d
6a
66
11
49
65
54
51
109 6b
113d 24
Fig. 22 Sectional drawing, standard construction type 7, motor frame size from 280 to 315
17
7 LS, LSV
90f
113c
54e
90e
54d
90d
123 53
79
54g
113 124
11b 58
116a 17
106 30b
107
105
105c
116 6a
67a
45
108
47c 49
51
11
33
54 67c
32
113d
6b
54i
Fig. 23 Sectional drawing, standard construction type 8, motor frame size from 355 to 400
18
LS, LSV
7
LSV pump, standard construction type 9
Construction
54e 10a 10b 11a 7 1a
54d 113c
123
54g
53
11b
79
113 124
58
17
30b
105
113g
105c
51 6a
67a
11 45
49
33
54
113d 32
6b
67c
54i
Fig. 24 Sectional drawing, standard construction type 9, motor frame size above 400
19
7 LS, LSV
90f 1a
90e
7
10a
10b
90d 11a
113e 113c
123
54d
113g
53
106
107
79
108
47c
116a
47d
124
6a
66
105
49
11
116c
17
45
49
116 45
51 6b
54
24
109
32
20
LS, LSV
7
LSV pump, standard construction type 17
Construction
90f 10a
7 10b
90e 11a
90d 1a
113g 54e
113c 54c
53 113
123 124
116a 79
106 58
107 105
17 51
108 6b
30b 66
47c 11
116
116c
49
24
116
17
45
49
45
6a
54
32 113d
90
21
7 LS, LSV
124 109a 116e 6a 17 11 20e 20d 105 58 58a 113 53 195 114a
109
110
116b
113f
113e
54e 113g
113d
11a
54c
123
54 113c
116a
114b
TM07 1153 1118
114
79 51 24 49 45 116c 66 116
22
LS, LSV
7
LS pump, optional construction type 12
Construction
116b 106 124 108 32 107 47c 33a 6a 11 116e 109 105 58 79 53
11b 195
113c
54g
113d
54e
54c 11a
54
113
116
6b 113g
116b 106 124 32 108 107 47c 33a 6a 11 116e 109 105 58 79 53
113f 113c
195
113d
54d
123
54
113
116 11a
116c
45
TM07 1155 1118
23
7 LS, LSV
26c
26b
72a
20b
20c
24
LS, LSV
7
Material specification
Construction
Pos. no Description Material Material standard
1a Bracket Steel
Cast iron ASTM A48 Class35
6a Pump casing, upper
Ductile iron ASTM A536, 65-45-12
Cast iron ASTM A48 Class35
6b Pump casing, lower
Ductile iron ASTM A536, 65-45-12
7 Coupling cover Stainless steel AISI 304
10a Coupling half, motor shaft Cast iron ASTM A48 Class35
10b Coupling half, pump shaft Cast iron ASTM A48 Class35
11 Key, impeller Steel ASTM A216 WCB
11a Key, coupling Steel ASTM A216 WCB
11b Key, bearing sleeve Steel ASTM A216 WCB
17 Vent screw Bronze
20 Drain plug Steel
20a Plug, drain outlet Steel
20b Plug, inlet Steel
20c Plug, outlet Steel
20d Plug, shaft seal flushing Steel
20e Plug, Inlet chamber Steel
24 Locking pin, wear ring Steel ANSI/ASME B18.8
26b Roll pin Steel ANSI/ASME B18.8
26c Screw for pump casing Steel
30b Tee, joint Stainless steel AISI 304
32 Flushing pipe Stainless steel AISI 304
33a Cross connection Stainless steel AISI 304
45 Wear ring Bronze ASTM B584, C90500
47c Retainer for packing Steel ASTM A216 WCB
47d Snap ring for packing Carbon steel
49 Impeller Stainless steel ASTM CF8
51 Shaft Stainless steel AISI 420
53 Bearing, drive end Steel
54 Bearing, non-drive end Steel/Bronze
54c Lock washer Steel
54d Circlip Steel ASTM A216 WCB
54g Bearing sleeve Cast iron ASTM A48 Class35
54e Round nut for bearing Steel ASTM A216 WCB
54i Set screw for sliding bearing Steel
58 Seal cover Cast iron ASTM A48 Class35
58a Screw Steel
65 Snap ring Stainless steel
66 O-ring for sleeve NBR
67a Impeller nut Stainless steel
67b Round nut for impeller Stainless steel
67c Set screw for impeller nut Stainless steel AISI 304
72a Gasket Vegetable fiber
76 Name plate Stainless steel AISI 304
79 Slinger Neoprene
90 Base-stand Cast iron /Steel
90d Support lower Steel
90e Round nut for support Steel
90f Support upper Steel
105 Shaft seal BBQV/GBQV SiC/Carbon
105c Seal retaining ring Stainless steel AISI 304
106 Packing gland Cast iron ASTM A48 Class35
107 Packing ring PTFE PTFE
108 Distribution ring Steel ASTM A216 WCB
109 O-ring NBR
109a O-ring NBR
110 O-ring NBR
113 Bearing housing Cast iron ASTM A48 Class35
113c Bearing cover, drive end Cast iron ASTM A48 Class35
113d Bearing cover, non-drive end Cast iron ASTM A48 Class35
113e Gasket Vegetable fiber
25
7 LS, LSV
Construction
26
LS, LSV
7
Mechanical construction Bearings
Construction
Position numbers in the following sections refer to the LS pumps are fitted with two deep-groove ball
sectional drawings and material specification bearings. The bearings are of the open type, and the
mentioned in section 7. Construction. bearings are lubricated by Grundfos prior to delivery.
LSV pumps are fitted with one ball bearings at the
Pump casing drive end and one sleeve bearing at the non-drive end
The pump casing has radial inlet port and radial outlet of the pump. The ball bearing is of the open type and
port. lubricated by Grundfos prior to delivery.
The pumps are of the in-line design. Seal housings
LS, LSV pumps have two seal housings (pos. D2), one
at the drive end and one at the non-drive end of the
pump shaft.
The seal housing has the following functions:
Impeller
The pump impeller is a closed double-inlet impeller.
The impeller has inflow of liquid from both sides to
ensure the balance of axial force.
TM04 0475 0708
Wear rings
TM06 2864 4714
27
7 LS, LSV
Coupling
Construction
As standard, LS, LSV pumps are fitted with an elastic D33 D31 D30 D32
pin coupling. See fig. 36.
Stuffing box
The stuffing box includes stuffing box gland (D33),
packing rings (D31), washer (D32) and distribution ring
(D30). See fig. 39.
The packing rings consist of braided material which is
effective for ensuring long service life for packing rings
while protecting the shaft (sleeve). When fitted, the
packing rings are symmetrical, having parallel facings
that prevent tilting.
In case of other special requirements for the stuffing
box (such as soft packing), please contact Grundfos.
28
LS, LSV
8
8. Operating conditions
Operating conditions
Pumped liquids Flow rate
LS pumps are suitable for pumping thin, clean, non-
aggressive and non-explosive liquids, not containing Minimum flow rate
solid particles or fibres. The maximum liquid The pump must not run against a closed outlet valve
temperature is 100 °C. In case you want to pump as this will cause an increase in temperature and
liquids with higher temperature or pump other liquids, formation of steam in the pump. This may cause shaft
please contact Grundfos. damage and impeller erosion, short life of bearings,
stuffing boxes with packing rings or mechanical shaft
seals due to stress or vibration.
Ambient temperature and altitude
The ambient temperature and the installation altitude Maximum flow rate
are important factors for the motor life, as they affect If the maximum flow rate is exceeded, cavitation and
the life of the bearings and the insulation system. overload may occur.
The ambient temperature must not exceed 40 °C. Note: Please refer to Grundfos Pump Selector data or
If the ambient temperature exceeds 40 °C or if the contact Grundfos if you have to operate an LS pump at
motor is installed more than 1000 m above sea level, conditions deviating from the rated duty point.
the motor must not be fully loaded due to the low
density and consequently low cooling effect of the air.
In such cases, it may be necessary to use a motor with
Sound pressure level
a higher output. Data in this table apply to pump including motor.
50 1.5 58 50 47
20 25 30 35 40 45 50 55 60 65 70 75 80 2.2 60 52 52
t [°C] 3.0 67 58 63
1000 2250 3500 m 4.0 69 58 63
5.5 68 64 63
Fig. 40 Relationship between motor output (P2) and 7.5 68 64 67
ambient temperature 11 70 65 67
15 70 65 57
Example
18.5 70 57 57
Figure 40 shows that the motor load must be reduced 22 67 57 57
to 88 % when the pump is installed 3500 m above sea 30 67 57 57
level. 37 67 57 57
45 67 57 58
At an ambient temperature of 70 °C, the motor load
55 71 57 58
must be reduced to 78 % of the rated output.
75 73 65 59
90 73 65 59
Pressures 110 73 65 60
132 73 65 60
160 76 65 63
Maximum operating pressure 200 76 65 67
1.0 MPa (rated head ≤ 75 m) 250 78 73 68
315 82 74 71
1.6 MPa (rated head > 75 m).
355 77 75 71
400 - 75 -
Minimum inlet pressure
The minimum inlet pressure must correspond to the
NPSH curve of the pump plus a safety margin of
minimum 0.5 m head.
29
8 LS, LSV
30
LS, LSV
9
etc.) /234.3
20
• best efficiency at the estimated duty point.
16 /210.8
NPSH
Efficiency [m]
12 12
If you expect the pump to always operate in the same
duty point, select a pump which is operating in a duty 8 8
point corresponding to the best efficiency of the pump.
4 NPSH 4
In case of varying consumption, select a pump whose
best efficiency falls within the duty range covering the
31
9 LS, LSV
In some cases, however, the input power actually To establish the motor safety margin, select method 1
Introduction to curve charts and technical data
40 40
/257.8
/234.3 12.8 15
20 20
/210.8 9.1 11
0 P2 max 0 6.1 7.5
0 200 400 600 800 1000 Q [m³/h] 4.3 5.5
3.2 4
Fig. 43 Establishing the maximum P2 when P2 decreases
2.3 3
as the flow rate increases.
1.7 2.2
Parameter 2 - motor safety margin 1.1 1.5
As with any system, uncertainties and tolerances exist, Fig. 44 Safety margins according to ISO 5199
the motor safety margin takes the following into
Method 2
account:
• The actual head is at the high end of the tolerance Add a 5 % safety margin to the maximum P2 found
described in ISO 9906. This will increase the when determining parameter 1.
required P2. Note: If a safety margin of 5 % is selected, normal
• Pump efficiency is at the low end of the tolerance guarantees of the performance from Grundfos may not
described in ISO 9906. This will increase the apply.
required P2. If not specified by the customer, the motor size will be
• Motor efficiency is at the low end. determined in accordance with the Grundfos Product
Center defaults listed above. This means a motor
which covers the full performance range and with a
motor safety margin according to ISO 5199.
Where to find the information
See performance curves from page 35 to page 95.
32
LS, LSV
9
How to read the curve charts
H [m]
LS/LSV 150-125-305 1450 rpm
45 ISO 9906-2012 Grade 2B
40
35 304mm
74% 77%
80% 82%
84%
30
279mm Performance tolerance
25 85%
84% standard
254mm 82%
80%
20 228mm 30
kW
203mm
15
77% 22
kW
10
18
.5k Efficiency curves
W
15
kW
5 11k
W
0
10
8
NPSH[m]
6
4 Input power curves
2
33
10 Performance curves and technical data
Overview
LS, LSV
Overview
34
LS, LSV Performance curves and technical data
2-pole
10
2-pole
2-pole
H [m]
LS/LSV 65-50-241 2900 rpm
100 ISO 9906-2012 Grade 2B
90
241mm 63% 66% 69% 71% 73% 73%
80
70 18.
5kW
213mm
60
15k
W
50 185mm 71%
40 171mm
69% 11k
W
30
7.5
kW
20
10
0
10
8
NPSH[m]
H [m]
LS/ LSV100-80-241 2900 rpm
100 ISO 9906-2012 Grade 2B
90
241mm
64% 67% 70%
80 72%
72%
70 216mm 45k
74% W
60
37k
190mm W
75%
50
30k
W
40 165mm
22k
30 W
18
.5k
W
20
15
kW
10
0
10
8
NPSH[m]
6
TM07 1015 1018
4
2
0
3
0 20 40 60 80 100 120 140 160 180 Q [m/h]
35
10 Performance curves and technical data
2-pole
LS, LSV
2-pole
H [m]
LS/LSV 125-100-279 2900 rpm
160 ISO 9906-2012 Grade 2B
140
120
70% 73% 76%
279mm 78% 80%
100 81%
81%
254mm
80 75k
W
229mm
80%
60
203mm 78% 55k
W
76%
40 73% 45k
W
37k
W
20
30k
W
0
10
8
NPSH[m]
H [m]
LS/LSV 125-100-305 2900 rpm
180 ISO 9906-2012 Grade 2B
160
140
304mm 64% 68%
72% 75%
120 78% 79%
279mm 80%
80%
100 79%
254mm 132
78% kW
80 228mm
110
kW
60 203mm
75%
90k
W
40 75k
W
55k
20 W
45k
W
0
10
8
NPSH[m]
6
TM07 1017 1018
4
2
0
3
0 50 100 150 200 250 300 350 400 450 Q [m/h]
36
LS, LSV Performance curves and technical data
4-pole
10
4-pole
4-pole
H [m]
LS/LSV 65-50- 241 1450 rpm
22 241mm 62% 65% ISO 9906-2012 Grade 2B
68%
70%
20 72%
73%
18 73%
213mm 72%
16 70%
68%
65%
14
185mm
12
171mm
10
3k
W
8
2.
2k
W
6
1.
5k
4
W
1.
1k
W
2
10
0 8
NPSH[m]
H [m]
LS/LSV 65-50-330 1450 rpm
50 ISO 9906-2012 Grade 2B
45
60%
40 330mm
64% 67%
70%
71%
72%
35 305mm 72%
71%
70%
30 279mm
67%
64%
11
kW
25 254mm
20 229mm 7.5
kW
60%
15 5.5
kW
10 4k
W
5
3k
W
0
10
8
NPSH[m]
6
TM07 1019 1018
4
2
0
3
0 10 20 30 40 50 60 70 80 90 Q [m/h]
37
10 Performance curves and technical data
4-pole
LS, LSV
4-pole
H [m]
LS/LSV 100-80-241 1450 rpm
32 ISO 9906-2012 Grade 2B
28
24
241mm 62% 65% 68% 70%
20 72%
72%
216mm 70%
16 73% 68%
190mm 5.5
kW
12
165mm 4kW
8 3kW
4 2.2k
W
1.5k
0 W
10
8
NPSH[m]
H [m]
LS/LSV 100-80-356 1450 rpm
50 ISO 9906-2012 Grade 2B
15
11
kW
10
7.5
5 kW
0
10
8
NPSH[m]
6
TM07 1021 1018
4
2
0
3
0 20 40 60 80 100 120 140 160 180 Q [m/h]
38
LS, LSV Performance curves and technical data
4-pole
10
4-pole
H [m]
LS/LSV 125-100-279 1450 rpm
36 ISO 9906-2012 Grade 2B
32
28
68% 72%
279mm 75%
78%
79%
24 80%
80%
254mm
20 79%
78%
75%
229mm 72%
16 11
kW
203mm
12
68%
7.5
8 kW
5.5
4 kW
0 4kW
10
8
NPSH[m]
H [m]
LS/LSV 125-100-305 1450 rpm
45 ISO 9906-2012 Grade 2B
40
35
304mm
71% 74%
76%
30 78% 79%
279mm
25 79%
254mm 78%
76%
74%
20 228mm
71%
18
.5k
W
15 203mm
15
kW
10
11
k W
5
7.5
kW
0 5.5
kW
10
8
NPSH[m]
6
TM07 1023 1018
4
2
0
3
0 30 60 90 120 150 180 210 240 270 Q [m/h]
39
10 Performance curves and technical data
4-pole
LS, LSV
4-pole
H [m]
LS/LSV 125-100-381 1450 rpm
72 ISO 9906-2012 Grade 2B
64
56
381mm 64% 68% 71%
48 74% 75%
348mm 75%
74%
40 71%
317mm 68%
76%
32 45
279mm kW
24 241mm 37
kW
16 30
kW
22
kW
8 18
.5k
15 W
kW
0 11
kW
10
8
NPSH[m]
H [m]
LS/LSV 150-125-305 1450 rpm
45 ISO 9906-2012 Grade 2B
40
35 304mm
74% 77%
80% 82%
84%
30
279mm
84%
25 254mm
85%
82%
80%
20 228mm 30
kW
203mm
15
77% 22
kW
18
.5k
10 W
15
kW
5 11k
W
0
10
8
NPSH[m]
6
TM07 1025 1018
4
2
0
3
0 50 100 150 200 250 300 350 400 450 Q [m/h]
40
LS, LSV Performance curves and technical data
4-pole
10
4-pole
H [m]
LS/LSV 150-125-381 1450 rpm
80 ISO 9906-2012 Grade 2B
72
64
24 45
kW
37
16 kW
30
kW
8
22
kW
0
10
8
NPSH[m]
H [m]
LS/LSV 200-150-305 1450 rpm
40 ISO 9906-2012 Grade 2B
35
304mm
68% 72%
76% 79%
30 82%
254mm 84%
84%
25
279mm 82%
79%
20 229mm
76%
15 203mm
30
kW
10 72%
22
kW
18
5 .5k
W
15
kW
0
10
8
NPSH[m]
6
TM07 1027 1018
4
2
0
3
0 80 160 240 320 400 480 560 640 720 Q [m/h]
41
10 Performance curves and technical data
4-pole
LS, LSV
4-pole
H [m]
LS/LSV 200-150-381 1450 rpm
80 ISO 9906-2012 Grade 2B
70
60
381mm 74% 78%
81%
50 356mm
84% 85%
86%
86%
330mm 85%
40 84%
81%
304mm 78%
30 280mm
75
kW
20
55
kW
45
kW
10
30
kW
0
10
8
NPSH[m]
H [m]
LS/LSV 200-150-483 1450 rpm
110 ISO 9906-2012 Grade 2B
100
90
70% 73%
482mm 76% 78%
80 81%
457mm 81.6%
70 432mm
81%
78%
60 406mm 76%
73%
381mm
50 11
0kW
40
90
kW
30 75
kW
20 55
kW
10
10
0 8
NPSH[m]
6
TM07 1029 1018
4
2
0
3
0 80 160 240 320 400 480 560 640 720 Q [m/h]
42
LS, LSV Performance curves and technical data
4-pole
10
4-pole
H [m]
LS/LSV 200-150-508 1450 rpm
135 ISO 9906-2012 Grade 2B
120
105 508mm
74% 77%
80% 81%
82%
90 470mm 82% 81%
80%
77%
75 431mm
20
0k
393mm W
60
355mm
74% 16
0k
45 W
13
2k
W
30 11
0kW
15 90
kW
10
8
NPSH[m]
H [m]
LS/LSV 250-200-305 1450 rpm
40 ISO 9906-2012 Grade 2B
35 304mm
70% 74%
78%
82%85%
30 88%
279mm 90%
90.56%
25
254mm 90%
20 228mm
88%
85%
82%
203mm 78%
15
74% 45
10 kW
70%
30
5 kW
22
kW
0
10
8
NPSH[m]
6
TM07 1031 1018
4
2
0
3
0 120 240 360 480 600 720 840 960 1080 Q [m/h]
43
10 Performance curves and technical data
4-pole
LS, LSV
4-pole
H [m]
LS/LSV 250-200-381 1450 rpm
72 ISO 9906-2012 Grade 2B
64
56
381mm
78%81%
48 355mm
84%86%
88%89%
89%
40 330mm 88%
86%
304mm 84%
81%
32
280mm 11
0kW
24 90
kW
75
16 kW
55
kW
8
45
kW
10
8
NPSH[m]
H [m]
LS/LSV 300-200-450 1450 rpm
88 ISO 9906-2012 Grade 2B
80
450mm
72
74% 77%
425mm 80% 82%
64 84% 85%
400mm 85%
56 84%
82%
375mm 80%
48
350mm 22
0k
40 20
W
0k
W
77%
32
16
0k
W
24 13
2k
W
16 11
0 kW
8
10
0 8
NPSH[m]
6
TM07 1033 1018
4
2
0
3
0 200 400 600 800 1000 1200 1400 1600 1800 Q [m/h]
44
LS, LSV Performance curves and technical data
4-pole
10
4-pole
H [m]
LS/LSV 300-200-489 1450 rpm
120 ISO 9906-2012 Grade 2B
105
30
20
0kW
15 16
0kW
13
2kW
0 110
kW
10
8
NPSH[m]
H [m]
LS/LSV 300-250-305 1450 rpm
40 ISO 9906-2012 Grade 2B
35
304mm
30 74%
279mm 78%
81%
84%
85%
25 86%
254mm
86%
236mm 85%
20 84%
81%
211mm 78%
15
55k
W
10 45k
W
74%
37k
5 W
30k
W
22k
0 W
10
8
NPSH[m]
6
TM07 1035 1018
4
2
0
3
0 200 400 600 800 1000 1200 1400 1600 1800 Q [m/h]
45
10 Performance curves and technical data
4-pole
LS, LSV
4-pole
H [m]
LS/LSV 300-250-381 1450 rpm
72
ISO 9906-2012 Grade 2B
64
56 390mm
76% 80%
83%
86% 87%
48 355mm
88%
88.73%
88%
40 330mm 87%
86%
83%
304mm 80%
32 160
279mm kW
24 132
kW
110
76% k W
16 90k
W
75k
8 W
55k
0 W
10
8
NPSH[m]
H [m]
LS/LSV 350-250-498 1450 rpm
100 ISO 9906-2012 Grade 2B
498mm
90
76% 80%
83%
86%
80 87%
88%
457mm 88.41%
88%
70 87%
86%
83%
60 406mm
80%
50
355mm
35
5k
40 W
30 25
0k
W
20 16
0k
W
10 13
2k
W
0
10
8
NPSH[m]
6
TM07 1037 1018
4
2
0
3
0 300 600 900 1200 1500 1800 2100 2400 2700 Q [m/h]
46
LS, LSV Performance curves and technical data
4-pole
10
4-pole
H [m]
LS/LSV 350-300-352 1450 rpm
44
352mm ISO 9906-2012 Grade 2B
40 68%
75%
325mm
36 81%
84%
310mm 86%
32 295mm 88%
89%
285mm
28
89%
24 88%
86%
84%
20 81%
16 90
kW
12 75
kW
55
kW
8
4
10
8
NPSH[m]
H [m]
LS/LSV 350-250-630 1450 rpm
200
ISO 9906-2012 Grade 2B
180
160 630mm
76%79%
82%84%
140 86%
87%
87.75%
87%
120 86%
533mm 84%
82%
100
71
80 0k
W
432mm 79% 63
0k
W
56
60 76% 0k
W
40 40
0k
W
20 31
5k
W
0
15
12
NPSH[m]
9
TM07 1039 1018
6
3
0
3
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [m/h]
47
10 Performance curves and technical data
4-pole
LS, LSV
4-pole
H [m]
LS/LSV 350-300-508 1450 rpm
100
ISO 9906-2012 Grade 2B
508mm
90 78%
82%
85%
88%
80 89%
457mm 90%
70 89%
431mm
88%
85%
60 406mm
381mm
50 63
0k
W
50
40 0k
W
82% 40
0k
W
30
31
5k
W
20
20
0k
W
10
0
15
12
NPSH[m]
H [m]
LS/LSV 450-350-397 1450 rpm
60 ISO 9906-2012 Grade 2B
55
50
45
40
35
30
25
20
15
10
5
NPSH [m]
3
0 300 600 900 1200 1500 1800 2100 2400 2700 Q [m/h]
48
LS, LSV Performance curves and technical data
4-pole
10
4-pole
H [m]
LS/LSV 500-300-490 1450 rpm
100 ISO 9906-2012 Grade 2B
90
80
70
60
50
40
30
20
10
0
NPSH [m]
H [m]
LS/LSV 500-300-508 1450 rpm
120 ISO 9906-2012 Grade 2B
110
100
90
80
70
60
50
40
30
20
NPSH [m]
3
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [m/h]
49
10 Performance curves and technical data
4-pole
LS, LSV
4-pole
H [m]
LS/LSV 500-300-680 1450 rpm
195 ISO 9906-2012 Grade 2B
180
165
150
135
120
105
90
75
60
45
NPSH [m]
H [m]
LS/LSV 500-300-710 1450 rpm
220 ISO 9906-2012 Grade 2B
200
180
160
140
120
100
80
60
40
20
0
NPSH [m]
3
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [m/h]
50
LS, LSV Performance curves and technical data
4-pole
10
4-pole
H [m]
LS/LSV 500-400-423 1450 rpm
65 ISO 9906-2012 Grade 2B
60
55
50
45
40
35
30
25
20
15
NPSH [m]
H [m]
LS/LSV 500-400-458 1450 rpm
80
ISO 9906-2012 Grade 2B
72
64
56
48
40
32
24
16
0
NPSH [m]
3
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [m/h]
51
10 Performance curves and technical data
4-pole
LS, LSV
4-pole
H [m]
LS/LSV 500-400-530 1450 rpm
110 ISO 9906-2012 Grade 2B
100
90
80
70
60
50
40
30
20
10
NPSH [m]
H [m]
LS/LSV 600-500-498 1480 rpm
110 ISO 9906-2012 Grade 2B
100
90 530mm
80 500mm 78%
82%
85%
70 470mm
88%
440mm
88%
60 410mm 85%
50 82%
630
560 kW
kW
40 500
kW
30 450
k
400 W
k
355 W
20 kW
10
NPSH [m]
8
6
TM07 1257 1218
4
2
0
3
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [m/h]
52
LS, LSV Performance curves and technical data
4-pole
10
4-pole
H [m]
610mm 75% 78%
LS/LSV 600-500-610 1480 rpm
130 595mm 81% ISO 9906-2012 Grade 2B
84%
120
87%
87%
110
545mm
84%
100
140
0kW
90 125
495mm
0kW
80
112
0 kW
70 445mm
10
60 00
kW
90
50 0k
W
80
40 0k
W
71
0k
W
30
10
8
NPSH [m]
H [m]
LS/LSV 125-100-370x2
1450rpm
115 ISO 9906 Grade 2B
370mm 57%
105 63%
67% 71%
355mm 73%
95
85 330mm
73%
71%
75 304mm
75
65
kW
279mm
55
55
kW
45
kW
45
37
30
kW
kW
18
22
.5
35
kW
kW
25
10
8
NPSH [m]
6
TM07 1099 1018
4
2
0
3
0 30 60 90 120 150 180 210 240 270 Q [m/h]
53
10 Performance curves and technical data
4-pole
LS, LSV
4-pole
H [m]
LS/LSV 150-125-415x2
1450 rpm
145
ISO 9906 Grade 2B
410mm 57% 63%
130 67% 71%
73%
390mm 76%
115
370mm 76%
73%
100 71%
340mm
67%
85
310mm
70
11
0
kW
90
55
kW
75
kW
55
40
45
kW
37k
kW
30k
W
W
25
10
10
NPSH [m]
8
6
H [m]
LS/LSV 200-150-475x2
1450 rpm
170 475mm 66% ISO 9906 Grade 2B
70% 74%
77%
155 80%
81%
445mm 82%
140 82%
81%
415mm
125 80%
77%
74%
110
28
385mm
0k
25
95
0k
355mm
W
22
0k
80
W
20
0k
W
65
16
0k
W
13
50
11
2k
0k
W
W
35
10
NPSH [m]
8
6
TM07 1107 1018
4
2
0
3
0 80 160 240 320 400 480 560 640 720 Q [m/h]
54
LS, LSV Performance curves and technical data
4-pole
10
4-pole
H [m] LS/LSV 250-200-575x2
1450 rpm
255 575mm ISO 9906 Grade 2B
66% 70%
74%
77%
230 80%
81%
535mm 82%
205 82%
495mm 81%
180 80%
77%
155 455mm
74%
70%
130 415mm
71
0k
63
W
0k
56
105
W
0k
50
W
0k
45
W
0k
40
80
W
0k
35
31
W
5k
5k
W
28
W
55
25
0k
W
0k
W
10
8
NPSH [m]
55
10 Performance curves and technical data
6-pole
LS, LSV
6-pole
6-pole
H [m]
LS/LSV 150-125-381 980 rpm
36 ISO 9906-2012 Grade 2B
32
28
381mm 74% 78% 81%
24 84%
85%
86%
355mm 86%
20 85%
84%
330mm
16 304mm
18
81% .5k
279mm W
12 78% 15
kW
8 11
kW
4 7.5
kW
10
8
NPSH[m]
H [m]
LS/LSV 200-150-305 980 rpm
18 ISO 9906-2012 Grade 2B
16
304mm
72%
14 76%
79%81%
279mm 83%
84%
12 84%
83%
254mm
10 81%
79%
76%
229mm
8
203mm 11
kW
6
72%
4 7.5
kW
5.5
2 kW
4k
W
0
10
8
NPSH[m]
6
TM07 1050 1018
4
2
0
3
0 50 100 150 200 250 300 350 400 450 Q [m/h]
56
LS, LSV Performance curves and technical data
6-pole
10
6-pole
H [m]
LS/LSV 200-150-381 980 rpm
36 ISO 9906-2012 Grade 2B
32
28
381mm 74%
24 78% 81%
84% 85%
356mm 86%
86%
20 85%
330mm 84%
81%
16 304mm 78%
280mm
22k
12 W
18.
5kW
8 15k
W
11k
4 W
7.5
kW
0
10
8
NPSH[m]
H [m]
LS/LSV 200-150-483 980 rpm
50
ISO 9906-2012 Grade 2B
45
40 70% 73%
482mm 76%
78%
81%
35 457mm 81.6%
81%
30 432mm
78%
406mm 76%
25 381mm 37
kW
20 73%
30
kW
15
22
kW
10
5 15
kW
0
10
8
NPSH[m]
6
TM07 1052 1018
4
2
0
3
0 50 100 150 200 250 300 350 400 450 Q [m/h]
57
10 Performance curves and technical data
6-pole
LS, LSV
6-pole
H [m]
LS/LSV 200-150-508 980 rpm
72 ISO 9906-2012 Grade 2B
64
56
16
30k
W
8
22k
W
0
10
8
NPSH[m]
H [m]
LS/LSV 250-200-305 980 rpm
18 ISO 9906-2012 Grade 2B
16
304mm
70% 74%
14 78%82%
85%
279mm 88%
90%
12 90.56%
90%
254mm
10 88%
85%
228mm 82%
8 78%
203mm
6 15
kW
74%
4 70%
11
kW
2 7.5
kW
0 5.5
kW
10
8
NPSH[m]
6
TM07 1054 1018
4
2
0
3
0 80 160 240 320 400 480 560 640 720 Q [m/h]
58
LS, LSV Performance curves and technical data
6-pole
10
6-pole
H [m]
LS/LSV 250-200-381 980 rpm
27 ISO 9906-2012 Grade 2B
24 381mm
78%81%
84%
355mm 86%
21 88%
89%
89%
18 330mm
88%
86%
304mm 84%
15 81%
280mm
12 30
kW
9
22
kW
6
11k
W
3
10
8
NPSH[m]
H [m]
LS/LSV 300-200-450 980 rpm
50 ISO 9906-2012 Grade 2B
45
40
35 450mm
74% 77%
425mm 80%82%
30 84%85%
400mm
85%
25 375mm
84%
82%
80%
350mm
20 75
kW
77%
15 55
kW
10 45
kW
5 30
kW
0
10
8
NPSH[m]
6
TM07 1056 1018
4
2
0
3
0 150 300 450 600 750 900 1050 1200 1350 Q [m/h]
59
10 Performance curves and technical data
6-pole
LS, LSV
6-pole
H [m]
LS/LSV 300-200-489 980 rpm
50 ISO 9906-2012 Grade 2B
45
489mm
40 74% 77%
80% 82%
84%85%
35 457mm 85.8%
85%
30 84%
406mm 82%
80%
77%
25 381mm
355mm
20 75
kW
15
55
kW
10 45
kW
5 30
kW
0
10
8
NPSH[m]
H [m]
LS/LSV 300-250-305 980 rpm
18 ISO 9906-2012 Grade 2B
16
304mm
14
74%
279mm 78%
81%
12 84%
85%
86%
254mm
86%
10 236mm 85%
84%
81%
8 78%
211mm
74%
6
18.
5kW
4 15k
W
11k
2 W
0 7.5
kW
10
8
NPSH[m]
6
TM07 1058 1018
4
2
0
3
0 100 200 300 400 500 600 700 800 900 Q [m/h]
60
LS, LSV Performance curves and technical data
6-pole
10
6-pole
H [m]
LS/LSV 300-250-381 980 rpm
36 ISO 9906-2012 Grade 2B
32
28
390mm
72%76%
24 80% 83%
86%
87%88%
355mm 88.73%
20
88%
330mm 87%
86%
16 304mm
83%
80%
279mm
12 45k
W
37k
8 W
76%
30k
W
4 22k
W
10
8
NPSH[m]
H [m]
LS/LSV 350-250-498 980 rpm
45 ISO 9906-2012 Grade 2B
498mm
40 77%80%
83%
86% 87%
35 88%
457mm 88.41%
88%
87%
30 86%
406mm
11
25 0 kW
355mm 90
20 83% kW
80% 75
15 kW
55
10 kW
45
kW
5
10
8
NPSH[m]
6
TM07 1060 1018
4
2
0
3
0 200 400 600 800 1000 1200 1400 1600 1800 Q [m/h]
61
10 Performance curves and technical data
6-pole
LS, LSV
6-pole
H [m]
LS/LSV 350-250-630 980 rpm
90
ISO 9906-2012 Grade 2B
80
630mm
70 76%79%
82%84%
86%
87%
60 87.75%
87%
86%
533mm
50 84%
82%
79%
40
432mm 20
0k
W
30 76% 16
0k
W
20 13
2k
W
10 11
0kW
90
kW
0
10
8
NPSH[m]
H [m]
LS/LSV 350-300-352 980 rpm
22
ISO 9906-2012 Grade 2B
20
352mm
18 73%
325mm 78%
81%
16 310mm
84%
86%
88%
295mm
14 285mm
89%
12 89%
88%
86%
10 84%
8
81% 30
6 kW
22
4 18
kW
.5k
W
2
10
0 8
NPSH[m]
6
TM07 1062 1018
4
2
0
3
0 150 300 450 600 750 900 1050 1200 1350 Q [m/h]
62
LS, LSV Performance curves and technical data
6-pole
10
6-pole
H [m]
LS/LSV 350-300-508 980 rpm
50 ISO 9906-2012 Grade 2B
45 508mm
74%
78%
82%
40 85%
88%
89%
90%
35 457mm
90%
89%
30 88%
406mm 85%
82%
25 78%
355mm
20 330mm 16
0k
W
13
15 2k
W
11
0kW
10
90
kW
75
5 kW
55
kW
0
10
8
NPSH[m]
H [m]
LS/LSV 500-300-710 980 rpm
100 ISO 9906-2012 Grade 2B
90
80
70
60
50
40
30
20
10
0
NPSH [m]
3
0 200 400 600 800 1000 1200 1400 1600 1800 Q [m/h]
63
10 Performance curves and technical data
6-pole
LS, LSV
6-pole
H [m]
LS/LSV 500-300-508 980 rpm
48 ISO 9906-2012 Grade 2B
44
40
36
32
28
24
20
16
12
8
NPSH [m]
H [m]
LS/LSV 450-350-397 980 rpm
ISO 9906-2012 Grade 2B
25
20
15
10
0
NPSH [m]
3
0 200 400 600 800 1000 1200 1400 1600 1800 Q [m/h]
64
LS, LSV Performance curves and technical data
6-pole
10
6-pole
H [m]
LS/LSV 500-400-458 980 rpm
40 ISO 9906-2012 Grade 2B
36
32
28
24
20
16
12
0
NPSH [m]
H [m]
LS/LSV 500-400-530 980 rpm
55 ISO 9906-2012 Grade 2B
50
45
40
35
30
25
20
15
10
0
NPSH [m]
3
0 300 600 900 1200 1500 1800 2100 2400 2700 Q [m/h]
65
10 Performance curves and technical data
6-pole
LS, LSV
6-pole
H [m]
LS/LSV 600-500-498 980 rpm
50
ISO 9906-2012 Grade 2B
45
40
35
30
25
20
15
10
0
NPSH [m]
H [m]
LS/LSV 600-500-610 980 rpm
60 ISO 9906-2012 Grade 2B
55
50
45
40
35
30
25
20
15
10
5
NPSH [m]
3
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [m/h]
66
LS, LSV Performance curves and technical data
6-pole
10
6-pole
H [m]
LS/LSV 700-500-667 980 rpm
90
ISO 9906-2012 Grade 2B
80
70
60
50
40
30
20
10
0
NPSH [m]
H [m]
LS/LSV 500-350-608 980 rpm
65
ISO 9906-2012 Grade 2B
60
55
50
45
40
35
30
25
20
15
NPSH [m]
3
0 300 600 900 1200 1500 1800 2100 2400 2700 Q [m/h]
67
10 Performance curves and technical data
6-pole
LS, LSV
6-pole
H [m]
LS/LSV 500-400-423 980 rpm
33 ISO 9906-2012 Grade 2B
30
27
24
21
18
15
12
3
NPSH [m]
H [m]
LS/LSV 500-350-702 980 rpm
110 ISO 9906-2012 Grade 2B
100
90
80
70
60
50
40
30
20
10
NPSH [m]
3
0 300 600 900 1200 1500 1800 2100 2400 2700 Q [m/h]
68
LS, LSV Performance curves and technical data
6-pole
10
6-pole
H [m]
LS/LSV 600-400-722 980 rpm
100 ISO 9906-2012 Grade 2B
90
80
70
60
50
40
30
20
10
0
NPSH [m]
H [m]
LS/LSV 500-300-490 980 rpm
39 ISO 9906-2012 Grade 2B
36
33
30
27
24
21
18
15
12
9
NPSH [m]
6
TM07 1077 1018
3
0 200 400 600 800 1000 1200 1400 1600 1800 Q [m/h]
69
10 Performance curves and technical data
6-pole
LS, LSV
6-pole
H [m]
LS/LSV 500-300-680 980 rpm
90 ISO 9906-2012 Grade 2B
75
60
45
30
15
NPSH [m]
H [m]
LS/LSV 500-400-498 980 rpm
50 ISO 9906-2012 Grade 2B
45
40
35
30
25
20
15
10
0
NPSH [m]
3
0 300 600 900 1200 1500 1800 2100 2400 2700 Q [m/h]
70
LS, LSV Performance curves and technical data
6-pole
10
6-pole
H [m]
LS/LSV 700-500-585 980 rpm
60 ISO 9906-2012 Grade 2B
55
50
45
40
35
30
25
20
15
0
NPSH [m]
H [m]
LS/LSV 700-500-725 980 rpm
110
ISO 9906-2012 Grade 2B
100
90
80
70
60
50
40
30
20
10
NPSH [m]
0
TM07 1081 1018
3
0 800 1600 2400 3200 4000 4800 5600 6400 7200 Q [m/h]
71
10 Performance curves and technical data
6-pole
LS, LSV
6-pole
H [m]
LS/LSV 800-600-667 980 rpm
80
ISO 9906-2012 Grade 2B
72
64
56
48
40
32
24
16
0
NPSH [m]
H [m]
LS/LSV 800-600-683 980 rpm
100 ISO 9906-2012 Grade 2B
90
80
70
60
50
40
30
20
10
0
NPSH [m]
3
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 Q [m/h]
72
LS, LSV Performance curves and technical data
6-pole
10
6-pole
H [m]
370mm
LS/LSV 125-100-370x2
980 rpm
44 70% 72% ISO 9906 Grade 2B
75%
78%
40 355mm
78%
36 330mm
75%
32
304mm 72%
28
279mm
24
22
kW
20 18
.5k
W
16
15
kW
12
11
k W
8
7.5
kW
4
10
8
NPSH [m]
H [m]
LS/LSV 150-125-415x2
415mm
980 rpm
55 68% ISO 9906 Grade 2B
72%
75%
50 390 mm
75%
370 mm
45
72%
40
340 mm 68%
35 37
kW
310 mm
30
30
kW
25
20 22
18 kW
15 .5k
kW W
15
11
kW
10
5
10
8
NPS [m]
6
TM07 1105 1018
4
2
0
3
0 30 60 90 120 150 180 210 240 270 Q [m/h]
73
10 Performance curves and technical data
6-pole
LS, LSV
6-pole
H [m]
LS/LSV 200-150-475x2
980 rpm
84 ISO 9906 Grade 2B
475mm
76 66% 70% 74%
77%
80%
68 445mm
81%
82%
82%
60 81%
415mm 80%
77%
52
90k
385mm
W
75
44
kW
355mm
36
55
kW
28 30
kW
45
37
kW
20
kW
12
10
8
NPSH [m]
H [m]
LS/LSV 250-200-575x2
575mm 66% 70% 980 rpm
110 74% 77% ISO 9906 Grade 2B
80%
81%
100
535mm 82%
90 82%
81%
495mm
80 80%
77%
455mm 74%
70
70%
60
22
415mm 20
0k
0k
W
W
50 16
0k
W
13
40 2k
11
W
0
kW
30
90
75
kW
kW
20
10
10
8
NPSH [m]
6
TM07 1113 1018
4
2
0
3
0 110 220 330 440 550 660 770 880 990 Q [m/h]
74
LS, LSV Performance curves and technical data
8-pole
10
8-pole
8-pole
H [m]
LS/LSV 500-400-458 740 rpm
24 ISO 9906-2012 Grade 2B
22
20
458mm
18
435mm
16 78%80%
82% 84%
86%
410mm
14 88%
382mm
12
86%
350.4 mm 55k
84% W
10 82%
45k
W
8 37k
W
6 30k
W
22k
W
10
8
NPSH [m]
H [m]
LS/LSV 500-400-530 740 rpm
45 530mm
ISO 9906-2012 Grade 2B
78% 80%
40 82% 84%
500mm
86%
35 88%
470mm
30 440mm 86%
84%
410mm 82%
25 200
kW
185
kW
20 160
kW
15
132
kW
10 110
kW
5 90k
W
10
8
NPSH [m]
6
TM07 1259 1218
4
2
0
3
0 300 600 900 1200 1500 1800 2100 2400 2700 Q [m/h]
75
10 Performance curves and technical data
8-pole
LS, LSV
8-pole
H [m]
LS/LSV 600-500-498 740 rpm
24 ISO 9906-2012 Grade 2B
22
20
18
16
14
12
10
2
NPSH [m]
3
0 300 600 900 1200 1500 1800 2100 2400 2700 Q [m/h]
H [m]
LS/LSV 600-500-610 740 rpm
45 ISO 9906-2012 Grade 2B
40
35
610mm 75% 78%
595mm 81%
84%
30 87%
87%
25 545mm
84%
185
495mm kW
20 160
kW
445mm
15 132
kW
110
10 kW
90k
W
5 75k
W
5
4
NPSH(m)
3
TM07 1260 1218
2
1
0
3
0 300 600 900 1200 1500 1800 2100 2400 2700 Q(m/h)
76
LS, LSV Performance curves and technical data
8-pole
10
8-pole
H [m]
LS/LSV 700-500-667 740 rpm
44 ISO 9906-2012 Grade 2B
40
36
32
28
24
20
16
12
4
NPSH [m]
H [m]
LS/LSV 700-500-585 740 rpm
ISO 9906-2012 Grade 2B
30
25
20
15
10
NPSH [m]
3
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [m/h]
77
10 Performance curves and technical data
8-pole
LS, LSV
8-pole
H [m]
LS/LSV 700-500-725 740 rpm
55 ISO 9906-2012 Grade 2B
50
45
40
35
30
25
20
15
10
5
NPSH [m]
H [m]
LS/LSV 800-600-667 740 rpm
50 ISO 9906-2012 Grade 2B
45
40
35
30
25
20
15
10
0
NPSH [m]
3
0 600 1200 1800 2400 3000 3600 4200 4800 5400 Q [m/h]
78
LS, LSV Performance curves and technical data
8-pole
10
8-pole
H [m]
LS/LSV 800-600-683 740 rpm
50 ISO 9906-2012 Grade 2B
45
40
35
30
25
20
15
10
0
NPSH [m]
H [m]
LS/LSV 1000-700-770 740 rpm
60 ISO 9906-2012 Grade 2B
55
50
45
40
35
30
25
20
15
10
NPSH [m]
3
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 Q [m/h]
79
10 Performance curves and technical data
8-pole
LS, LSV
8-pole
H [m]
LS/LSV 1000-700-815 740 rpm
65 ISO 9906-2012 Grade 2B
60
55
50
45
40
35
30
25
20
15
10
NPSH [m]
3
0 1200 2400 3600 4800 6000 7200 8400 9600 10800 Q [m/h]
80
LS, LSV Performance curves and technical data
10-pole
10
10-pole
10-pole
H [m]
LS/LSV 700-500-667 590 rpm
ISO 9906-2012 Grade 2B
25
20
15
10
5
NPSH [m]
H [m]
LS/LSV 700-500-725 590 rpm
50 ISO 9906-2012 Grade 2B
45
40
35
30 725mm
80%82%
695mm 84% 86%
88%
25 665mm
88%
635mm 89% 86%
84%
20 82%
575mm 80%
15
2
20 20kW
185 0kW
10 160
kW
kW
132
5 110
kW
kW
10
8
NPSH [m]
6
TM07 1262 1218
4
2
0
3
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [m/h]
81
10 Performance curves and technical data
10-pole
LS, LSV
10-pole
H [m]
LS/LSV 800-600-683 590 rpm
30 ISO 9906-2012 Grade 2B
25
20
15
10
5
NPSH [m]
3
0 600 1200 1800 2400 3000 3600 4200 4800 5400 Q [m/h]
H [m]
LS/LSV 800-600-667 590 rpm
25 725mm ISO 9906-2012 Grade 2B
12.5 160
kW
10 132
kW
7.5 110
kW
90k
5 W
75k
W
2.5
0
10
8
NPSH [m]
6
TM07 1263 1218
4
2
0
3
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [m/h]
82
LS, LSV Performance curves and technical data
10-pole
10
10-pole
H [m]
LS/LSV 1000-700-770 590 rpm
44 ISO 9906-2012 Grade 2B
40
36
32
28
24
20
16
12
4
NPSH [m]
H [m]
LS/LSV 1000-700-815 590 rpm
44
ISO 9906-2012 Grade 2B
40
36
32
28
24
20
16
12
4
NPSH [m]
0
TM07 1093 1018
3
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 Q [m/h]
83
10 Performance curves and technical data
10-pole
LS, LSV
10-pole
H [m]
LS/LSV 1200-800-1075 590 rpm
70 ISO 9906-2012 Grade 2B
65
60
55
50
45
40
35
30
25
20
NPSH [m]
H [m]
LS/LSV 1200-800-1080 590 rpm
70 ISO 9906-2012 Grade 2B
65
60
55
50
45
40
35
30
25
20
NPSH [m]
3
0 1500 3000 4500 6000 7500 9000 10500 12000 13500 Q [m/h]
84
LS, LSV Performance curves and technical data
Dimensional sketches and dimensions
10
CP
X YY W
DNs
N Keyway
DNd
HZ
U
D
G
DH
SH
AE BP WS
WB
Dimensions [mm]
Pump size
DNs1) DNd2) YY X HZ SH DH AE A CP W N
LS 65-50-241 65 50 216 216 311 89 89 260 305 502 305 60
LS 65-50-330 65 50 254 254 397 89 89 260 305 502 305 60
LS 100-80-241 100 80 279 279 330 102 102 260 305 502 305 60
LS 100-80-356 100 80 305 305 422 127 127 260 305 622 368 60
LS 125-100-279 125 100 305 305 410 124 124 260 305 622 368 60
LS 125-100-305 125 100 305 305 410 124 124 260 305 622 368 60
LS 125-100-381 125 100 357 357 508 159 156 260 305 622 368 60
LS 150-125-305 150 125 330 330 448 165 165 260 305 768 419 60
LS 150-125-381 150 125 381 356 527 165 165 260 305 794 432 60
LS 200-150-305 200 150 406 356 502 165 165 260 305 794 432 60
LS 200-150-381 200 150 406 381 578 184 184 260 311 922 508 90
LS 200-150-483DF 200 150 432 432 603 171 171 260 305 868 489 90
LS 200-150-483DG 200 150 432 432 603 171 171 260 305 902 489 76
LS 200-150-508 200 150 483 432 651 171 171 260 318 994 546 95
LS 250-200-305 250 200 432 406 549 171 171 260 305 922 508 90
LS 250-200-381 250 200 483 483 629 178 178 260 324 941 518 90
LS 300-200-450 300 200 550 500 635 230 230 560 700 956 556 102
LS 300-200-489 300 200 559 414 732 198 198 502 648 1298 723 105
LS 300-250-305 300 250 495 495 619 203 203 260 324 967 530 90
LS 300-250-381 300 250 584 432 629 254 254 381 457 1045 600 102
LS 350-250-498 350 250 660 508 772 246 246 502 648 1389 797 165
LS 350-250-630 350 250 711 610 806 305 305 502 648 1354 798 160
LS 350-300-508 350 300 711 584 783 313 313 502 648 1391 749 105
LS 350-300-352 350 300 560 500 652 260 260 520 680 1361 754 105
LS 450-350-397 450 350 625 545 730 285 285 610 790 1400 773 105
LS 500-300-490 500 300 715 605 870 315 315 680 860 1565 885 165
LS 500-300-508 500 300 715 605 870 315 315 680 860 1565 885 165
LS 500-300-710 500 300 780 670 860 385 385 725 905 1585 907 200
LS 500-300-680 500 300 780 670 860 385 385 725 905 1585 907 200
LS 500-350-608 500 350 750 630 925 315 315 680 860 1542 860 170
LS 500-350-702 500 350 785 750 1105 310 310 680 860 1660 920 170
LS 500-400-423 500 400 700 600 890 325 325 680 860 1585 895 165
LS 500-400-458 500 400 700 600 830 330 330 680 860 1585 895 165
LS 500-400-530 500 400 715 605 880 315 315 680 860 1565 885 165
LS 500-400-498 500 400 715 605 880 315 315 680 860 1565 885 165
LS 600-500-498 600 500 850 750 1065 425 425 700 900 1717 957 165
LS 600-400-722 600 400 920 750 1168 365 365 780 960 1841.5 1010 170
85
10 Performance curves and technical data
Dimensional sketches and dimensions
LS, LSV
Dimensional sketches and dimensions
1)
DNs: Nominal diameter of inlet port.
2)
DNd: Nominal diameter of outlet port.
86
LS, LSV Performance curves and technical data
Dimensional sketches and dimensions
10
CP
X YY W
DNs
N Keyway
DNd
HZ
U
G
D
DH
K AE J SH BP WS
WB
Dimensions [mm]
Pump size
DNs1) DNd2) YY X HZ SH DH AE A CP W N
LS 600-500-610 600 500 850 800 1179 420 420 720 1135 1795 1010 200
LS 800-600-683 800 600 1135 900 1340 465 465 850 1393 2095 1160 200
LS 800-600-667 800 600 1135 900 1340 465 465 850 1393 2095 1160 200
LS 1000-700-770 1000 700 1300 1070 1565 585 585 1020 1600 2491 1398 250
LS 1000-700-815 1000 700 1300 1070 1565 585 585 1020 1600 2491 1398 250
LS 1200-800-1075 1200 800 1600 1320 1895 640 640 1220 1840 2564 1400 225
LS 1200-800-1080 1200 800 1600 1320 1895 640 640 1220 1840 2564 1400 225
LS 600-500-610 920 50 100 760 630 886 1453 33 110 110 8 3300
LS 800-600-683 1100 40 100 850 735 1060 1690 33 175 175 8 5000
LS 800-600-667 1100 40 100 850 735 1050 1685 33 175 175 8 4900
LS 1000-700-770 1335 50 129 1000 898 1200 1998 33 180 180 8 6800
LS 1000-700-815 1335 50 129 1000 898 1200 1998 33 180 180 8 6800
LS 1200-800-1075 1565 50 145 1460 670 1660 2230 40 200 200 8 10550
LS 1200-800-1080 1565 50 145 1460 670 1660 2230 40 200 200 8 10550
1)
DNs: nominal diameter of inlet port.
2) DNd: nominal diameter of outlet port.
87
10 Performance curves and technical data
Dimensional sketches and dimensions
LS, LSV
Dimensional sketches and dimensions
CP
X YY W
DNs N Keyway
DNd
HZ
U
D
DH
SH
BP1
B1
K AE J n- H Outlet side
Dimensions [mm]
Pump size
DNs1) DNd2) YY X HZ SH DH AE A CP W N
LS 700-500-585 700 500 950 800 1255 380 380 750 1200 1955 1090 200
LS 700-500-667 700 500 950 800 1255 380 380 750 1200 1955 1090 200
LS 700-500-725 700 500 950 800 1255 380 380 750 1200 1955 1090 200
LS 700-500-585 940 40 100 560 860 700 1000 33 150 150 8 3500
LS 700-500-667 940 40 100 560 860 700 1000 33 150 150 8 3500
LS 700-500-725 940 40 100 560 860 700 1000 33 150 150 8 3500
1)
DNs: nominal diameter of inlet port.
2)
DNd: nominal diameter of outlet port.
88
LS, LSV Performance curves and technical data
Dimensional sketches and dimensions
10
j1 j2 a f A
w
e
k
h
U
h1
c
DNd DNs
p1
Dimensions [mm]
Pump size
1) 2)
DNs DNd j1 j2 V x y m1 a f e h1
LS 200-150-475 x 2 200 150 550 575 260 300 300 140 527 615 102 500
LS 250-200-575 x 2 250 200 600 750 310 500 350 160 696 800 133 600
n1
U
v
h1
c
DNd DNs p1
n2 p2 Inlet center
p1
n - HH m2
TM07 1234 1218
n1 (m1)
m1
View A
B
Dimensions and weights
Dimensions [mm]
Pump size
DNs1) DNd2) j1 j2 V n1 n2 a f e h1 h
LS 125-100-370 x 2 125 100 340 350 210 520 400 458 540 95 350 705
LS 150-125-415 x 2 150 125 365 375 250 520 400 484 575 105 400 782
89
10 Performance curves and technical data
Dimensional sketches and dimensions
LS, LSV
Dimensional sketches and dimensions
A A DNd S CD
View B
4- 19
45
X
HH
A
YY
YD
Dimensions
Dimensions [mm]
Pump size
DNs1) DNd2) YY X S Z D YD CD A HH U
LSV 65-50-241 65 50 216 216 89 89 178 298 322 508 457 25.35
LSV 65-50-330 65 50 254 254 127 127 216 298 370 508 457 25.35
LSV 100-80-241 100 80 279 279 102 102 203 302 329 508 457 25.35
LSV 100-80-356 100 80 305 305 127 127 254 333 395 508 457 34.92
LSV 125-100-279 125 100 305 305 133 133 257 333 376 508 457 34.92
LSV 125-100-305 125 100 305 305 133 133 257 333 306 508 457 34.92
LSV 125-100-381 125 100 357 357 171 171 330 333 437 508 457 34.92
LSV 150-125-305 150 125 330 330 203 203 368 384 344 508 457 34.92
LSV 150-125-381 150 125 381 356 244 244 410 397 383 508 457 34.92
LSV 200-150-305 200 150 406 356 241 241 406 397 360 508 457 34.92
LSV 200-150-381 200 150 406 381 279 279 464 514 398 711 660 44.44
LSV 200-150-483DF 200 150 432 432 260 260 432 481 443 711 660 47.62
LSV 200-150-483DG 200 150 432 432 260 260 432 481 443 711 660 47.62
LSV 200-150-508 200 150 483 432 279 279 451 447 471 508 457 53.97
LSV 250-200-305 250 200 432 406 267 267 438 514 386 711 660 44.44
LSV 250-200-381 250 200 483 483 305 305 483 524 424 711 660 44.44
LSV 300-200-450 300 200 550 500 300 300 530 527 435 711 660 57.14
LSV 300-200-489 300 200 559 414 330 330 529 648 485 813 711 57.14
LSV 300-250-305 300 250 495 495 300 300 503 537 421 711 660 44.44
LSV 300-250-381 300 250 584 432 254 254 508 603 475 711 660 57.14
90
LS, LSV Performance curves and technical data
Dimensional sketches and dimensions
10
W1
W
YY
L2 L3
YD
Z
DNs L1
Dimensions
Dimensions [mm]
Pump size
DNs1) DNd2) YY X S Z D YD CD W W1 L L1 L2 L3 U
800/ 725/ 1150/ 610/ 510/ 440/
LSV 350-250-498 350 250 660 508 340 340 586 595 515 79.37
927 860 1220 700 590 410
LSV 350-250-630 350 250 710 610 330 330 635 584 577 880 810 1240 730 650 440 74.98
LSV 350-300-508 350 300 711 584 330 330 693 634 552 927 860 1235 700 590 410 57.14
LSV 350-300-352 350 300 560 500 325 325 585 617.7 327 800 725 1150 610 510 440 63.49
LSV 450-350-397 450 350 625 545 365 365 650 660 450 935 865 1170 685 610 410 57.13
LSV 500-400-423 500 400 700 600 400 400 725 710 390 1100 1030 1400 835 650 445 79.37
LSV 500-400-458 500 400 700 600 420 420 750 710 510 1100 1030 1425 860 675 445 79.37
LSV 600-500-498 600 500 850 750 475 475 900 785 506 1230 1160 1690 1055 970 550 74.98
91
10 Performance curves and technical data
Counterflange dimensions
LS, LSV
Counterflange dimensions
Counterflange dimensions
Dimensional sketches
D1 D2
K1 K2
Ds Dd
Dimensions
Dimensions [mm]
Pump size Flange stage
Ds Dd n1 n2 d1 d2 K1 K2 D1 D2
LS, LSV 65-50-330D PN10 65 50 4 4 19 19 145 125 190.5 165.1
LS, LSV 65-50-241B PN10 65 50 4 4 19 19 145 125 190.5 165.1
LS, LSV 100-80-356E PN10 100 80 8 8 19 19 180 160 254 209.6
LS, LSV 100-80-241E PN10 100 80 8 8 19 19 180 160 254 209.6
LS, LSV 125-100-279E PN10 125 100 8 8 19 19 210 180 279.4 254
LS, LSV 125-100-305F PN10 125 100 8 8 19 19 210 180 279.4 254
LS, LSV 125-100-381F PN10 125 100 8 8 19 19 210 180 279.4 254
LS, LSV 150-125-305E PN10 150 125 8 8 23 19 240 210 317.5 279
LS, LSV 150-125-381F PN10 150 125 8 8 23 19 240 210 317.5 279
LS, LSV 200-150-305C PN10 200 150 8 8 23 23 295 240 381 317.5
LS, LSV 200-150-381A PN10 200 150 8 8 23 23 295 240 381 317.5
LS, LSV 200-150-483D PN10 200 150 8 8 23 23 295 240 381 317.5
LS, LSV 200-150-483DF PN10 200 150 8 8 23 23 295 240 381 317.5
LS, LSV 200-150-483DG PN10 200 150 8 8 23 23 295 240 381 317.5
LS, LSV 200-150-508B PN10 200 150 8 8 23 23 295 240 381 317.5
LS, LSV 250-200-305C PN10 250 200 12 8 23 23 350 295 444.5 381
LS, LSV 250-200-381B PN10 250 200 12 8 23 23 350 295 406.4 342.9
LS, LSV 300-250-305E PN10 300 250 12 12 23 23 400 350 520.7 444.5
LS, LSV 300-250-381B PN10 300 250 12 12 23 23 400 350 520.7 444.5
LS, LSV 300-200-450A PN10 300 200 12 8 23 23 400 295 520.1 381
LS, LSV 300-200-489C PN10 300 200 12 8 23 23 400 295 520.7 381
LS, LSV 350-250-498C PN10 350 250 16 12 23 23 460 350 584.2 444.5
LS, LSV 350-250-630B PN10 350 250 16 12 23 23 460 350 584.2 444.5
LS, LSV 350-300-352C PN10 350 300 16 12 23 23 460 400 533 483
LS, LSV 350-300-508C PN10 350 300 16 12 23 23 460 400 584.2 520.7
LS, LSV 350-300-508D PN10 350 300 16 12 23 23 460 400 584.2 520.7
LS, LSV 450-350-397B PN10 450 350 20 16 28 23 565 460 640 535
LS, LSV 500-300-490E PN10 500 300 20 12 28 23 620 400 670 445
LS, LSV 500-300-508F PN10 500 300 20 12 28 23 620 400 670 445
LS, LSV 500-300-710E PN10 500 300 20 12 28 23 620 400 715 460
LS, LSV 500-300-680F PN10 500 300 20 12 28 23 620 400 715 460
LS, LSV 500-350-608A PN10 500 350 20 16 28 23 620 460 670 505
LS, LSV 500-350-702A PN10 500 350 20 16 28 23 620 460 670 505
LS, LSV 500-400-423A PN10 500 400 20 16 28 28 620 515 715 580
LS, LSV 500-400-458C PN10 500 400 20 16 28 28 620 515 715 580
LS, LSV 500-400-530B PN10 500 400 20 16 28 28 620 515 715 597
LS, LSV 500-400-498C PN10 500 400 20 16 28 28 620 515 715 597
LS, LSV 600-400-722A PN10 600 400 20 16 31 28 725 515 780 565
LS, LSV 600-500-498A PN10 600 500 20 20 31 28 725 620 840 715
LS, LSV 600-500-610B PN10 600 500 20 20 31 28 725 620 840 715
LS, LSV 700-500-725E PN10 700 500 24 20 31 28 840 620 920 715
LS, LSV 700-500-667D PN10 700 500 24 20 31 28 840 620 920 715
LS, LSV 700-500-585F PN10 700 500 24 20 31 28 840 620 920 715
LS, LSV 800-600-683B PN10 800 600 24 20 34 31 950 725 1025 840
LS, LSV 800-600-667C PN10 800 600 24 20 34 31 950 725 1025 840
LS, LSV 1000-700-770H PN10 1000 700 28 24 37 31 1160 840 1255 910
92
LS, LSV Performance curves and technical data
Counterflange dimensions
10
Counterflange dimensions
Dimensions [mm]
Pump size Flange stage
Ds Dd n1 n2 d1 d2 K1 K2 D1 D2
LS, LSV 1000-700-815F PN10 1000 700 28 24 37 31 1160 840 1255 910
LS, LSV 1200-800-1075B PN10 1200 800 32 24 40 34 1380 950 1455 1015
LS, LSV 1200-800-1080C PN10 1200 800 32 24 40 34 1380 950 1455 1015
LS, LSV 65-50-330D PN16 65 50 4 4 19 19 145 125 190.5 165.1
LS, LSV 65-50-241B PN16 65 50 4 4 19 19 145 125 190.5 165.1
LS, LSV 100-80-356E PN16 100 80 8 8 19 19 180 160 254 209.6
LS, LSV 100-80-241E PN16 100 80 8 8 19 19 180 160 254 209.6
LS, LSV 125-100-279E PN16 125 100 8 8 19 19 210 180 279.4 254
LS, LSV 125-100-305F PN16 125 100 8 8 19 19 210 180 279.4 254
LS, LSV 125-100-381F PN16 125 100 8 8 19 19 210 180 279.4 254
LS, LSV 125-100-370Ax2 PN16 125 100 8 8 19 19 210 180 250 220
LS, LSV 150-125-305E PN16 150 125 8 8 23 19 240 210 317.5 279
LS, LSV 150-125-381F PN16 150 125 8 8 23 19 240 210 317.5 279
LS, LSV 150-125-415Ax2 PN16 150 125 8 8 23 19 240 210 285 250
LS, LSV 200-150-305C PN16 200 150 12 8 23 23 295 240 381 317.5
LS, LSV 200-150-381A PN16 200 150 12 8 23 23 295 240 381 317.5
LS, LSV 200-150-483D PN16 200 150 12 8 23 23 295 240 381 317.5
LS, LSV 200-150-483DF PN16 200 150 12 8 23 23 295 240 381 317.5
LS, LSV 200-150-483DG PN16 200 150 12 8 23 23 295 240 381 317.5
LS, LSV 200-150-508B PN16 200 150 12 8 23 23 295 240 381 317.5
LS, LSV 200-150-475Ax2 PN16 200 150 12 8 23 23 295 240 360 300
LS, LSV 250-200-305C PN16 250 200 12 12 28 23 355 295 444.5 381
LS, LSV 250-200-381B PN16 250 200 12 12 28 23 355 295 406.4 342.9
LS, LSV 250-200-575Ax2 PN16 250 200 12 12 28 23 355 295 425 360
LS, LSV 300-250-305E PN16 300 250 12 12 28 28 410 355 520.7 444.5
LS, LSV 300-250-381B PN16 300 250 12 12 28 28 410 355 520.7 444.5
LS, LSV 300-200-450A PN16 300 200 12 12 28 23 410 295 520.1 381
LS, LSV 300-200-489C PN16 300 200 12 12 28 23 410 295 520.7 381
LS, LSV 350-250-498C PN16 350 250 16 12 28 28 470 355 584.2 444.5
LS, LSV 350-250-630B PN16 350 250 16 12 28 28 470 355 584.2 444.5
LS, LSV 350-300-352C PN16 350 300 16 12 28 28 470 410 533 483
LS, LSV 350-300-508C PN16 350 300 16 12 28 28 470 410 584.2 520.7
LS, LSV 350-300-508D PN16 350 300 16 12 28 28 470 410 584.2 520.7
LS, LSV 450-350-397B PN16 450 350 20 16 31 28 585 470 640 535
LS, LSV 500-300-490E PN16 500 300 20 12 34 28 650 410 715 460
LS, LSV 500-300-508F PN16 500 300 20 12 34 28 650 410 715 460
LS, LSV 500-300-710E PN16 500 300 20 12 34 28 650 410 715 460
LS, LSV 500-300-680F PN16 500 300 20 12 34 28 650 410 715 460
LS, LSV 500-350-608A PN16 500 350 20 16 34 28 650 470 715 520
LS, LSV 500-350-702A PN16 500 350 20 16 34 28 650 470 715 520
LS, LSV 500-400-423A PN16 500 400 20 16 34 31 650 525 715 580
LS, LSV 500-400-458C PN16 500 400 20 16 34 31 650 525 715 580
LS, LSV 500-400-530B PN16 500 400 20 16 34 31 650 525 715 597
LS, LSV 500-400-498C PN16 500 400 20 16 34 31 650 525 715 597
LS, LSV 600-400-722A PN16 600 400 20 16 37 31 770 525 840 580
LS, LSV 600-500-498A PN16 600 500 20 20 37 34 770 650 840 715
LS, LSV 600-500-610B PN16 600 500 20 20 37 34 770 650 840 715
LS, LSV 700-500-725E PN16 700 500 24 20 37 34 840 650 920 715
LS, LSV 700-500-667D PN16 700 500 24 20 37 34 840 650 920 715
LS, LSV 700-500-585F PN16 700 500 24 20 37 34 840 650 920 715
LS, LSV 800-600-683B PN16 800 600 24 20 40 37 950 770 1060 840
LS, LSV 800-600-667C PN16 800 600 24 20 40 37 950 770 1060 840
LS, LSV 1000-700-770H PN16 1000 700 28 24 43 37 1170 840 1255 910
LS, LSV 1000-700-815F PN16 1000 700 28 24 43 37 1170 840 1255 910
LS, LSV 1200-800-1075B PN16 1200 800 32 24 49 40 1390 950 1485 1025
LS, LSV 1200-800-1080C PN16 1200 800 32 24 49 40 1390 950 1485 1025
LS, LSV 65-50-330D PN25 65 50 8 4 19 19 145 125 190.5 165.1
LS, LSV 100-80-356E PN25 100 80 8 8 23 19 190 160 254 209.6
LS, LSV 100-80-241E PN25 100 80 8 8 23 19 190 160 254 209.6
LS, LSV 125-100-279E PN25 125 100 8 8 28 23 220 190 279.4 254
LS, LSV 125-100-305F PN25 125 100 8 8 28 23 220 190 279.4 254
LS, LSV 125-100-381F PN25 125 100 8 8 28 23 220 190 279.4 254
LS, LSV 125-100-370Ax2 PN25 125 100 8 8 28 23 220 190 250 220
LS, LSV 150-125-305E PN25 150 125 8 8 28 28 250 220 317.5 279
LS, LSV 150-125-381F PN25 150 125 8 8 28 28 250 220 317.5 279
LS, LSV 150-125-415Ax2 PN25 150 125 8 8 28 28 250 220 300 270
93
10 Performance curves and technical data
Counterflange dimensions
LS, LSV
Counterflange dimensions
Dimensions [mm]
Pump size Flange stage
Ds Dd n1 n2 d1 d2 K1 K2 D1 D2
LS, LSV 200-150-305C PN25 200 150 12 8 28 28 310 250 381 317.5
LS, LSV 200-150-381A PN25 200 150 12 8 28 28 310 250 381 317.5
LS, LSV 200-150-483D PN25 200 150 12 8 28 28 310 250 381 317.5
LS, LSV 200-150-483DF PN25 200 150 12 8 28 28 310 250 381 317.5
LS, LSV 200-150-483DG PN25 200 150 12 8 28 28 310 250 381 317.5
LS, LSV 200-150-508B PN25 200 150 12 8 28 28 310 250 381 317.5
LS, LSV 200-150-475Ax2 PN25 200 150 12 8 28 28 310 250 360 300
LS, LSV 250-200-305C PN25 250 200 12 12 31 28 370 310 444.5 381
LS, LSV 250-200-381B PN25 250 200 12 12 31 28 370 310 444.5 381
LS, LSV 250-200-575Ax2 PN25 250 200 12 12 31 28 370 310 425 360
LS, LSV 300-250-305E PN25 300 250 16 12 31 31 430 370 520.7 444.5
LS, LSV 300-250-381B PN25 300 250 16 12 31 31 430 370 520.7 444.5
LS, LSV 300-200-450A PN25 300 200 16 12 31 28 430 310 520.1 381
LS, LSV 300-200-489C PN25 300 200 16 12 31 28 430 310 520.7 381
LS, LSV 350-250-498C PN25 350 250 16 12 34 31 490 370 584.2 444.5
LS, LSV 350-250-630B PN25 350 250 16 12 34 31 490 370 584.2 444.5
LS, LSV 350-300-352C PN25 350 300 16 16 34 31 490 430 584 520
LS, LSV 350-300-508C PN25 350 300 16 16 34 31 490 430 584.2 520.7
LS, LSV 350-300-508D PN25 350 300 16 16 34 31 490 430 584.2 520.7
LS, LSV 450-350-397B PN25 450 350 20 16 37 34 600 490 710 585
LS, LSV 500-300-710E PN25 500 300 20 16 37 31 660 430 730 485
LS, LSV 500-300-680F PN25 500 300 20 16 37 31 660 430 730 485
LS, LSV 500-400-423A PN25 500 400 20 16 37 37 660 550 730 620
LS, LSV 500-400-530B PN25 500 400 20 16 37 37 660 550 775 648
LS, LSV 500-400-498C PN25 500 400 20 16 37 37 660 550 775 648
LS, LSV 600-500-498A PN25 600 500 20 20 40 37 770 660 915 775
LS, LSV 600-500-610B PN25 600 500 20 20 40 37 770 660 845 730
LS, LSV 700-500-725E PN25 700 500 24 20 43 37 875 660 960 730
LS, LSV 700-500-667D PN25 700 500 24 20 43 37 875 660 960 730
LS, LSV 700-500-585F PN25 700 500 24 20 43 37 875 660 960 730
94
LS, LSV Performance curves and technical data
Flange forces and torques
10
95
11 LS, LSV
11. Accessories
Accessories
Cyclone separator
General information
Cyclone separators are used to clean mainly aqueous
liquids containing dirt and solids. The best possible
filtration efficiency is achieved when the specific
gravity of the solids is much higher than that of the
carrier liquid, and when the differential pressure is as
large as possible within the permissible pressure
range (minimum 1.7 bar). The viscosity of the pumped
liquid is also a factor that needs to be taken into
account.
Note: The cyclone separator can separate particles,
but not suspended solids.
96
LS, LSV
12
All select
The section contains the following:
• technical data
• curves (duty point curve, multi-speed curve, parallel
pump curve and system curve, etc.).
Outline
• Complete pump drawing
• bare-shaft pump drawing.
For more information about Grundfos pump selector,
please contact your local Grundfos company.
97
14 LS, LSV
http://product-selection.grundfos.com
98
99
ECM: 1266658
99439536 0819
GRUNDFOS A/S
www.grundfos.com
Telephone: +45 87 50 14 00
DK-8850 Bjerringbro . Denmark