MANUALLY DRIVEN R.C.C. PILE
Providing cast in-situ manually driven
reinforced cement concrete piles of using
required grade of cement concrete of required
1 bore-diameter, bulb diameter, lengths and with
reinforcement as per specifications and
drawings. Reinforcement to be measured and
paid seperately as per item no. 21.4.1
C) UNIFORM PILE
d) Pile Dia 400 mm
ii) Above 10 M Rm 12180.00
LOAD TEST ON PILES
Initial test for test loading to 2 times the
specified safe working load including
2 construction of any test pile cap and dismantling Ton 60.00
the same after completion of test. (Rate for Safe
working Load)
REINFORCEMENT
Supplying, fitting and fixing in position
reinforcement bars conforming to relevent IS
code, for reinforced cement concrete works in
piles including straightening, cleaning, cutting
2 and bending to proper shapes and length as per
specifications and drawings. The rings should
be welded with vertical reinforcements as per
specified IS codes of practice. (Inclusive of lap
length, hook, chair, bend, anchor...etc)
(A) TMT bar made of Primary producer (From
Primary producer)
Qtl 1552.36
EARTHWORK IN EXCAVATION
Earthwork in excavation for foundations,
trenches of walls, retaining walls, footings of
column, steps, septic tank etc. including refilling
(return filling) the quantity as necessary after
completion of work, braking clods in return
filling, dressing, watering and ramming etc. and
3 removal of surplus earth with all lead and lift as
directed and specified in the following
classification of soils including bailing out water
where necessary as directed and specified.
(A) Upto a depth of 2.00m below the existing
ground level.
(a) In ordinary soil Cum 820.65
TOTAL UNIT
QUANTIT
Unit AMOUN RATES TOTAL
DESCRIPTION OF ITEMS UNIT Rate T OFFERE AMOUNT
Y
offered ( in INR D IN OFFERED IN
)
WORDS WORDS
Earth/ sand filling in plinth in layers not more
than 150mm thick including necessary carriage,
watering, ramming etc. complete as directed
and specified including payment of land
compensation, forest royalty, sales tax and
other duties and taxes as may be necessary.
(c) With river sand or silt (predominantly non
plastic) by truck carriage including loading and
unloading.
Ground Floor Area 4190 sqm x .9 m plinth Cum 2950.35
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse
aggregate of sizes 13mm to 32mm in foundation
bed for footing steps, walls, brick works etc. as
directed and specified including dewatering if
necessary, and curing complete (shuttering
where necessary shall be measured and paid
separately).
(b) In prop 1cement: 4 sand :8 coarse cum
aggregate by volume
102.58
Plain cement concrete floor base in prop1:3:6
laid in alternate bays as specified with coarse
agg. of size 13mm to 32mm including
dewatering if necessary, and curing etc.
4
complete.
c) 100mm thick sqm 4,910.00
Plinth Area = 4910 sqm.
Providing and laying 25mm thick damp proof
course with cement concrete in prop 1:1.5:3
with graded stone agg. of 10mm down nominal
size including providing approved damp proof sqm 479.475
admixture in proportion as recommended by the
manufacturer including curing etc. complete as
directed.
Total length of wall =1917.9m x .250 m
MASONARY WORK
Providing brick soling in foundation and under
floor with stone/ best quality picked jhama brick,
3 sand packed and laid to level and in panel after
preparing the sub grade as directed including all
labour and materials and if necessary
dewatering complete.
(a)Brick on flat soiling. Sq.m 4190.00
Ground floor Area = 4190 sqm.
Autoclaved Aerated Cement blocks work
(AAC)
Providing and laying autoclaved aerated cement
blocks masonry with 150mm/230mm/300 mm
thick AAC blocks with RCC band at sill level
and lintel level with approved block laying
4 polymer modified adhesive mortar all complete
as per direction of Engineerin- Charge. (The
payment of RCC band and reinforcement shall
be made for seperately).
DESCRIPTION OF ITEMS Unit
Unit Total
QUANTIT rate Total amount
UNIT rate amount
Y offered offered in
offered (in INR)
in words words
(i) In Sub-structure upto plinth level including
dewatering if necessary Cum 132.34
Total length of wall =1917.9 m x (.900-.600) m x
.200m
(ii)In Superstructure above plinth level upto 1st
floor level.
Cum 589.77
Extra for AAC block walling of each subsequent
floor or part therof above the 1st floor level. Cum 326.33
PLASTERING WORKS
15 mm plaster on cement concrete or reinforced
cement concrete work with white cement based
17 polymer modified self curing mortar of approved Sq.m 5128.40
make as per the direction of Engineer-In-
Charge.
Wall area → 3485.53 X 2= 6971.06
12 mm plaster on cement concrete or reinforced
cement concrete work with white cement based
18 polymer modified self curing mortar of approved Sq.m 5128.40
make as per the direction of Engineer-In-
Charge.
10mm thick cement plaster in single coat on fair
side of brick/concrete walls for interior plastering
upto 3rd floor level including arises or rounded
19 angles not exceeding 80mm girth and finished
even and smooth including curing complete as
directed.
(d) In cement mortor 1:6 Sq.m 18529.33
Ceiling area =9791 sqm
RCC Fin =1780 x 2=3560
Slab Beam area = 1917.9x0.45 x2x3=4749.3
sqm
HERITAGE FINISHING
Supplying and laying of permanent wall finish
for interior and exterior walls with surface
coating of Heritage Surface Texture of Bakelite
Hylam Limited for all types of buildings at all
levels as specified and directed by the
department.
(a) Granules (Code : HGR) Sqm 638.28
=(17.5+14.5+14.5+12.6) X 3.6 X3
b) Executive range
Somany/ Orient/Nitco /Varmora/VITA/ Marbito/
Make
i) Of size 800mmx800mm and above Sq.m 9848.38
B) ON WALLS
TOTAL
Unit AMOUN UNIT
QUANTIT
DESCRIPTION OF ITEMS UNIT Rate T
Y
offered ( in INR RATES TOTAL
) OFFERE AMOUNT
D IN OFFERED IN
WORDS WORDS
Providing polished ceramic wall tiles of
approved quality, size, shape and thickness not
less than 8mm on walls and skirtings over
cement mortar bed 10 mm thick in prop. 1:3 (1
cement : 3 coarse sand ) including cutting
where necessary finished with flush pointing
with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf)
/white cement slurry mixed with approved
pigment to match shade of tiles complete at all
24 levels as specified and directed. (Cement
plastering to be measured and paid separately).
(Coloured pigment should be in conformity with
colour of tiles and as approved and directed by
the Department). (Walls means both interior and
exterior walls).
c) Delux range
Somany/ Orient/Nitco/Varmora Make
ii) Of size 300mmx450mm and above Sq.m 1201
WALL TILES→ 95.32 X 2.1X2 X3 =3979.52
ANTISKID TILES
Providing Antiskid Tiles of approved quality
size, shape not less than 8mm on floor, skirting
over a cement mortar bed 15mm thick of 1:3 (1
cement: 3 coarse sand) approved make fix with
Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white
cement complete at all level as specified and
directed.
(A) CERAMIC
i)Normal range (Sizes 300 mm x 300mm and
above)
(a)Orient made: Galaxy Brown, Galaxy
creama, Galaxy Pink, Galaxy Green, Pulsar
Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Sq.m 538.62
Burj Brown, Burj Green, Burj Slate
K STEEL WORKS
ROOF TRUSS
TOTAL UNIT
Unit AMOUN RATES TOTAL
QUANTIT
DESCRIPTION OF ITEMS UNIT Rate T OFFERE AMOUNT
Y
offered ( in INR D IN OFFERED IN
) WORDS WORDS
Providing, fitting, hoisting and fixing of roof trusses
fabricated out of combination of any two or all of
the following sections (i) Square section (ii)
Rectangular Hollow section of specification RSH/SHS
and (iii) M.S. circular hlollow section of Grade 210
including purlins, bottom runners and providing
M.S. cleat, M.S. angle base plank, bolts and nuts
with red oxide primer including fitting bottom
runner and cleat etc. for fixing ceiling joist as per
design complete as directed as per specifications.
a) Using TATA make RHS/SHS of Grade 310 Qtl
conforming to relevant I.S. code 4923 : 1997 100.90
A.Roof truss in doom→20.1 x 8=160.8 M
B.Roof truss in pargola→(19 x25)+72 =547 M
COLLAPSIBLE / ROLLING SHUTTERS
Providing and fixing in position collapsible M.S. Sq.m.
shutters with vertical channels
20mmx10mmx2mm braced with flat iron
diagonals 20mmx5mm size with top and bottom
rails of T-iron 40mmx40mmx6mm with 38mm
dia steel pulleys complete with bolts and nuts,
locking arrangements, stoppers, handles
including applying a priming coat of red lead
paint. 25.92
Providing and fixing rolling shutters of approved Sq.m.
make made of 80mm wide M.S. laths
interlocked together through their entire lenth
and jointed together at the ends by end-locks
mounted on specially designed pipe shaft with
bracket plates, guide channels and
arrangements for inside and outside locking with
push-pull operation complete including cost of
wire, spring and hood cover for the shutters. 108
DOOR FRAMES
Providing, fitting and fixing powder coated
pressed steel door frame made of 1.25mm/
1.6mm thick sheet of various sizes with
necessary hinge jamb, lock jamb, head and
steel base ties at the bottom of the frame. The
whole frame shall be welded or rigidly fixed
together by mechanical means with base ties of
pressed mild steel angle of size 20x20x1.25mm
thick. Frame to be filled up with 1:4:8 P.C.C.
after fitting the frame with brick/ concrete works
etc.complete as directed by the department for
all levels. (P.C.C. to be measured and paid for
seperately).
(a) 1.25mm thick sheet
(iv) Size 125mm x 60mm (Double rebate) M 1178.4
TOTAL UNIT
Unit AMOUN RATES TOTAL
QUANTIT
DESCRIPTION OF ITEMS UNIT Rate T OFFERE AMOUNT
Y
offered ( in INR D IN OFFERED IN
) WORDS WORDS
Door Frame → total door =223nos.
→(2.1+2.1+1.2) x 137= 739.8 m
→(2.1+2.1+.9) x 86= 438.6m
Providing and fixing stainless steel (Grade 304)
railing made of Hollow tubes , channels , plates
etc., including welding , grinding , buffing
polishing and making curvature (wherever
required) and fitting the same with necessary
stainless steel nuts and bolts complete , i.e.
fixing the railing with necessary accessories &
30 stainless steel dash fasteners ,stainless steel Kg. 486.50
bolts etc., of required size , on the top of the
floor or the side of waist slab with suitable
arrangement as per approval of Engineer in-
charge. (For payment, only weight of stainless
steel member is be considered.No extra
payment for fixing accessories such as nuts,
bolts, fasteners etc. will be considered)
A. → 3.9 X2 X 3X 8=187.2
B. → (39.4+ 27.8)X4=268.8
C. → (11.5+11.5+7.5)=268.8
GRILLS
Providing, fitting and fixing M.S. grill of
required pattern for windows/ clerestory
windows/ openingwith M.S. flats at required
spacing in frame all round, squre or round
M.S. bars with round headed bolts and nuts or
screws.
I . Plain grill
(c) Fixed to Brickwork/P.C.C/R.C.C. Kg 5656.45
→ Total area =550 sqm,10mm sqr bar 150c/c
@ 10.29kg/m2= 5656.45 kg
ROOFING
Providing plain Polycarbonate transparent sheet
roofing at all levels with self drilling, self tapping
screws complete (Roof trusses, purlins etc. to
be measured and paid separately.)
(iii) 3.00 mm thick Sqm 221.6
PLINTH PROTECTION WORKS
Providing plinth protection 50mm thick to
cement concrete 1 : 3 : 6 with coarse agg.of
20mm nominal size including finishing the
surface with 10mm thick cement plaster in
proportion 1:3 with a floting coat of neat cement
finished. Sqm
621
TOTAL UNIT
Unit AMOUN RATES TOTAL
QUANTIT
DESCRIPTION OF ITEMS UNIT Rate T OFFERE AMOUNT
Y
offered ( in INR D IN OFFERED IN
) WORDS WORDS
Providing drain with brick work in cement mortar
in proportion 1:5 with half brick thick side walls
and 100mm thick C.C (1:3:6) base over one
brick flat soling including 15mm thick cement
plastering in prop. 1:3 finished with a floating
coat of cement slurry as directed with necessary
shttering for sides and earth work in excavation
of foundation trenches and refilling the sides
after completion of work etc. as specified.
ii). 300mm wide and average 250mm deep with
bed slope 1 in 150 with initial depth of 100mm. Rm
810
REINFORCEMENT STEEL
Supplying, fitting and fixing in position
reinforcement bars conforming to relevant I.S.
Code for R.C.C. work/ R.B. walling including
straightening, cleaning, cutting and bending to
proper shapes and length as per details,ying
and binding with 20G annealed black wire and
31 placing in position with proper blocks, supports,
chairs, spacers etc. complete (upto 1st floor
level).
ISI approved super ductile TMT Bar
Unit
TOTAL UNIT
AMOUN RATES
QUANTIT Rate
Sl.No. DESCRIPTION OF ITEMS UNIT T OFFERED
Y offere
( in INR
d
)
IN TOTAL AMOUNT
WORDS OFFERED IN WORDS
MANUALLY DRIVEN R.C.C. PILE
Providing cast in-situ manually driven
reinforced cement concrete piles of
using required grade of cement
concrete of required bore-diameter,
bulb diameter, lengths and with
reinforcement as per specifications
1 and drawings. Reinforcement to be
measured and paid seperately as per
item no. 21.4.1
C) UNIFORM PILE
d) Pile Dia 400 mm
ii) Above 10 M Rm 3960.00
LOAD TEST ON PILES
Initial test for test loading to 2 times the
specified safe working load including
construction of any test pile cap and Ton 60.00
dismantling the same after completion of
test. (Rate for Safe working Load)
REINFORCEMENT
Supplying, fitting and fixing in position
reinforcement bars conforming to
relevent IS code, for reinforced
cement concrete works in piles
including straightening, cleaning,
cutting and bending to proper shapes
and length as per specifications and
drawings. The rings should be welded
with vertical reinforcements as per
specified IS codes of practice.
(Inclusive of lap length, hook, chair,
bend, anchor...etc)
2 (A) TMT bar made of Primary
producer (From Primary producer)
Qtl 504.71
TOTAL UNIT
Unit RATES
AMOUN
QUANTIT Rate
DESCRIPTION OF ITEMS UNIT T OFFERED
Y offere
( in INR IN TOTAL AMOUNT
d
) WORDS OFFERED IN WORDS
EARTHWORK IN EXCAVATION
Earthwork in excavation for
foundations, trenches of walls,
retaining walls, footings of column,
steps, septic tank etc. including
refilling (return filling) the quantity as
necessary after completion of work,
braking clods in return filling, dressing,
watering and ramming etc. and
removal of surplus earth with all lead
and lift as directed and specified in the
following classification of soils
4 including bailing out water where
necessary as directed and specified.
Stair case →
Waist slab = 3.35 x 4.06 x3 x 2 =
81.6
Step = 3.40 x 0.150 x 24 x3 x2 =
73.44
Landing = 3.40 x 1.50 x3 x2= 30.6
Beam = 2 x 3.40 x 0.300 x3x2 =
12.24
MASONARY WORK
Providing brick soling in foundation
and under floor with stone/ best quality
picked jhama brick, sand packed and
laid to level and in panel after
3
preparing the sub grade as directed
including all labour and materials and
if necessary dewatering complete.
c) Delux range
Somany/ Orient/Nitco /Varmora/VITA/
Marbito/ Make
i) Of size 1000mmx1000mm and Sq.m
above 2811.35
→ 1020+995.02+796.33=2811
sqm
B) ON WALLS
TOTAL UNIT
Unit
QUANTIT Rate
AMOUN RATES
DESCRIPTION OF ITEMS UNIT T OFFERED
Y offere
( in INR IN TOTAL AMOUNT
d
)
WORDS OFFERED IN WORDS
Providing polished ceramic wall tiles of
approved quality, size, shape and
thickness not less than 8mm on walls and
skirtings over cement mortar bed 10 mm
thick in prop. 1:3 (1 cement : 3 coarse
sand ) including cutting where necessary
finished with flush pointing with Fix-A-Tile
(Choksey / Sika / Pedelite / Rouf) /white
cement slurry mixed with approved
24 pigment to match shade of tiles complete
at all levels as specified and directed.
(Cement plastering to be measured and
paid separately). (Coloured pigment
should be in conformity with colour of
tiles and as approved and directed by the
Department). (Walls means both interior
and exterior walls).
c) Delux range
Somany/ Orient/Nitco/Varmora Make
ii) Of size 300mmx450mm and above Sq.m 364.68
ground floor →(3*2.1*6)+(6.5*2.1*2)-
(1.2*.9*4)=60.78 x 2=121.56 sqm
1st floor →121.56 sqm
2nd floor → 121.56 sqm
ANTISKID TILES
Providing Antiskid Tiles of approved
quality size, shape not less than 8mm
on floor, skirting over a cement mortar
bed 15mm thick of 1:3 (1 cement: 3
coarse sand) approved make fix with
Fix-A-Tile
(Choksey/Sika/Pedelite/Rouf)/ white
cement complete at all level as
specified and directed.
VITRIFIED
i)Normal range (Sizes 300 mm x
300mm and above)
Somany made- Durastone
(Unpolished heavy duty Vitrified Tiles)
a). Premium Sq.m 108
TOTAL UNIT
Unit RATES
AMOUN
QUANTIT Rate
DESCRIPTION OF ITEMS UNIT T OFFERED
Y offere
( in INR IN TOTAL AMOUNT
d
) WORDS OFFERED IN WORDS
Ground floor →18 x2 = 36 sqm.
1st floor →18 x2 = 36 sqm.
2nd floor → 18 x2 = 36 sqm.
Providing polished SUNROCK-Hi
CTS/ MULTIWYN tiles of approved
quality, size, shape and thickness not
less than 18mm on floors and skirtings
over cement mortar bed 10 mm thick
in prop. 1:3 (1 cement : 3 coarse sand
) including cutting where necessary
finished with flush pointing with Fix-A-
Tile (Choksey / Sika / Pedelite / Rouf)
/white cement slurry mixed with
approved pigment to match shade of
tiles complete at all levels as specified
and directed. (Coloured pigment
should be in conformity with colour of
tiles and as approved and directed by
the Department).
K STEEL WORKS
ROOF TRUSS
Providing, fitting, hoisting and fixing of roof
trusses fabricated out of combination of any
two or all of the following sections (i) Square
section (ii) Rectangular Hollow section of
specification RSH/SHS and (iii) M.S. circular
hlollow section of Grade 210 including purlins,
bottom runners and providing M.S. cleat, M.S.
angle base plank, bolts and nuts with red
oxide primer including fitting bottom runner
and cleat etc. for fixing ceiling joist as per
design complete as directed as per
specifications.
A. → 3.9 X2 X 3X 8=187.2
B. → (39.4+ 27.8)X4=268.8
C. → (11.5+11.5+7.5)=268.8
GRILLS
TOTAL UNIT
Unit
QUANTIT Rate
AMOUN RATES
DESCRIPTION OF ITEMS UNIT T OFFERED
Y offere
( in INR IN TOTAL AMOUNT
d
)
WORDS OFFERED IN WORDS
Providing, fitting and fixing M.S. grill
of required pattern for windows/
clerestory windows/ openingwith
M.S. flats at required spacing in
frame all round, squre or round
M.S. bars with round headed bolts
and nuts or screws.
I . Plain grill
(c) Fixed to Brickwork/P.C.C/R.C.C. Kg 5656.45 2.16
→ Total area =550 sqm,10mm sqr bar
150c/c @ 10.29kg/m2= 5656.45 kg
ROOFING
Providing plain Polycarbonate
transparent sheet roofing at all levels
with self drilling, self tapping screws
complete (Roof trusses, purlins etc. to
be measured and paid separately.)
(iii) 3.00 mm thick Sqm 221.60
PLINTH PROTECTION WORKS
Providing plinth protection 50mm thick
to cement concrete 1 : 3 : 6 with
coarse agg.of 20mm nominal size
including finishing the surface with
10mm thick cement plaster in Sqm 103.50
proportion 1:3 with a floting coat of
neat cement finished.
L REINFORCEMENT STEEL
Unit
TOTAL UNIT
AMOUN RATES
QUANTIT Rate
DESCRIPTION OF ITEMS UNIT T OFFERED
Y offere
( in INR
d
) IN TOTAL AMOUNT
WORDS OFFERED IN WORDS
Supplying, fitting and fixing in position
reinforcement bars conforming to
relevant I.S. Code for R.C.C. work/
R.B. walling including straightening,
cleaning, cutting and bending to
proper shapes and length as per
details,ying and binding with 20G
31 annealed black wire and placing in
position with proper blocks, supports,
chairs, spacers etc. complete (upto 1st
floor level).
ISI approved super ductile TMT Bar
6.00 metre
length.
b) MP upto 6.00
2.1.2 metre length. point 650
2.2.1 Each 40
Medium point up to 6.00 metre. Length.
2.2.2 Each 60
Long point up to 10.00 metre. Length.
2.7.1
With 2x2.5 sqmm+ earth continuity
with1x2.5 sqmm PVC insulated
unsheathed single core copper conductor
cable in 19mm dia.rigid PVC conduit
pipes. mtr 8500
2.7.2 With 2x4sqmm+ earth continuity
with1x2.5 sqmm PVC insulated
unsheathed single core copper conductor
cable in 19mm dia.rigid PVC conduit
pipes. mtr 1000
2.7.3
With 2x6sqmm+ earth continuity with1x4
sqmm PVC insulated unsheathed single
core copper conductor cable in 19mm
dia.rigid PVC conduit pipes. mtr 900
6/2.8
Each 90
8/11.12 Supplying and fixing of polished Brass
Bracket of 18 S.W.G, 25 cm long cast
back plate and brass lamp holder
complete including connection as
approved by the Deptt.)as required
Without Lamp
Each 110
9/10 Supplying,installation,testing and
Commission of the following indoor
surface Mounted LED Luminaires
complete with all accessories such as
driver etc. and necessary connection with
1.5 sq.mm. P.V.C. insulated S.C.copper
conductor as required and as directed by
the department
2 Ton capacity
(Carrier make) estrella R410 Each 4
UNIT TOTAL
RATE AMOUNT
UNIT TOTAL OFFERED OFFERED
RATE AMOUNT IN IN
Sl. No. Description of works Unit Qty. OFFERED OFFERED WORDS WORDS
25/31.1 Supplying with fitting and fixing Voltage
stabilizer of the following specification
complete including making necessary
connection as approved, specified and
directed by the deptt. (SKYLAND / Vee-
Dee / V GUARD / VERTEX/ INDO/
VENUS make)
31.1.8 5.0 KVA Automatic Input 90-280 V Out
put 200-240 V Each 4
26/SB8.63 Supplying with fitting and fixing of Single
Phase Modular Motor Starter switch of
the following specification complete
including making necessary connection
as specified and directed by the deptt.
16.1.2 C Series
(Schneider MG, legrand, Hager make)
16.1.2.1 6-32A Each 450
UNIT TOTAL
RATE AMOUNT
UNIT TOTAL OFFERED OFFERED
RATE AMOUNT IN IN
Sl. No. Description of works Unit Qty. OFFERED OFFERED WORDS WORDS
30/16.6 Supplying with fitting and fixing 4P 10 KA
240/415V 50Hz MCB of the following
capacity complete with making
necessary connection as approved,
specified and directed by the deptt.
16.6.2 C Series (ABB, Schneider MG, legrand,
Hager make)
16.6.2.3 63A Each 26
31/16.7 Supplying with fitting and fixing
30/100/300mA sensitivity 240/415V 50Hz
DP RCCB of the following capacity
complete with making necessary
connection as approved, specified and
directed by the deptt.
25 KA 415V 50 Hz 3P MCCB
(Havells, HPL, Indo Asian make)
i)63A Each 26
ii)125A Each 8
36/ECB5.1 Supplying including installation testing
and commissioning of 100kVAr, 440V
APFC Panel Non-Compartmentalized
Type, Free Standing, Floor Mounted
rated Output 100kVAr
rated Voltage 440V
rated Frequency 50Hz
Number of phases 3 Phase
Switching Option Auto-Manual
ENCLOSURE DETAILS
Material CRCA
Thickness of sheet steel Frame & Doors:
2.0mm, Partitions: 1.6mm, Gland plate:
3.0mm
Dimensions W x H x D (mm) 800 x 1800
x 600 (Approx) + (250 mm for plinth & fan
hook
Ingress Protection IP 42
Installation Type Indoor
Cable Entry Bottom
Colour RAL 7035 - Light Grey
BUSBAR DETAILS
Material Aluminium
Cross Section (mm) 40 x 10 x 1 Run
Bus bar Supports DMC Moulded
CAPACITORS
Heavy Duty @ 440V
No of Steps 5
Incomer MCCB, 200A, 36kA CVS Type
Switching Capacitor Duty Contactors
Step Protection MCB/MCCB
APFC RELAY
INCOMER MCCB, 200A, 36kA CVS
Type 1
UNIT TOTAL
RATE AMOUNT
UNIT TOTAL OFFERED OFFERED
RATE AMOUNT IN IN
Sl. No. Description of works Unit Qty. OFFERED OFFERED WORDS WORDS
Set 1
37/32.1
.
32.1.3 3&1/2core A2XFY
32.1.3.4 70.00 Sq. mm.3 & 1/2 Core armoured
U.G. cable Mtr 100
32.1.3.7 150.00 Sq. mm.3 & 1/2 Core armoured
U.G. cable Mtr 160
UNIT TOTAL
RATE AMOUNT
UNIT TOTAL OFFERED OFFERED
RATE AMOUNT IN IN
Sl. No. Description of works Unit Qty. OFFERED OFFERED WORDS WORDS
38/32.5
Supply and laying of following size Solid
Aluminium conductor up to 10 sq mm
balance stranded conductor, XLPE
Insulated, cores laid up, PVC tape inner
sheathed, Armour (Aluminium for single
core up to 70 sq mm balance Aluminium
strip, Galvanised for cables up to 2x10 sq
mm.3x10 sq mm,4x6 sq mm balance all
galvanised steel strip) , extruded PVC
Type ST2 sheathed, 650/1100V grade as
per IS 7908(Part 1) 1988, LT armoured
3&1/2core A2XWY,A2XFY
32.5.3
32.5.3.4 70.00 Sq.mm 3&1/2 Core U.G. cable in
50mm dia medium duty hot dip
galvanised pipe (AKG or equivalent as
approved by the Deptt.)
Mtr 300
32.5.3.7 150.00 Sq.mm 3&1/2 Core U.G. cable
in 65mm dia medium duty hot dip
galvanised pipe (AKG or equivalent as
approved by the Deptt.)
Mtr 50
39/SB15.1 Supplying installation, testing and
commissioning of Passenger
Elevator(KONE make for 3stop(544 K 8
persons) having contract speed of 0.65
Metre/Sec(approx.)mps serving different
floor in the existing lift shaft as per
detailed specification enclosed and as
under
Each 1
2/2
2.7
Each 6
3/2
2.1 Extra for using salt 5Kg and charcoal
2 64 Kg. for pipe earth electrode as
required. Each 6
4/2
2.1 Supplying and laying with 6 SWG GI
5 earth wire at 0.50 mtr. below ground
level or conductor earth electrode
including soldering, excavation work
and refitting etc.as required
complete.
Mtr 120
Unit
Rate Total Amt Unit Rate Total Amt
Sl. offered( offered(R offered in offered in
No. Description of works Unit Qty. Rs) s) words words
5/4
1.4
41.
4.2
1 TECHNICAL DATA CJ250D5P
GENERATOR SET
SPECIFICATIONS 250/200
3. No. of Phases. 3 phase.
4. POWER FACTOR 0.8 LAG
JACKSON ENGINE
SPECIFICATION.
1. make). Cummins
2. Model. 6CTA-8.3-G4
3. No. of Cylinders. 6
4. Aspiration. TURBO CHARGED
AIR TO AIR COOLED
5. Cooling. Water Cooled.
6. Governor. Electronic
7. Battery Capacity Rating. 2x12
Volt.
8. FUEL CONSUMPTION LTR/HR @
75% LOAD 40.8
ALTERNATOR SPECIFICATION.
1. make). CGT (STAMFOR
2. Voltage Regulation. +/- 1.0%
3. Insulation. Class - H.
4. Standard Enclosure. IP 23
5. No. of Phases. 3
Each 2
6/2
3.1
1
Supplying including installation,
connection as approved by the
Deptt.)with 2x2.5 sq mm copper FR
cable, testing and commissioning of
following BOLLARD LIGHT on
Cement concrete foundation
including lamp, driver, ballast as
required complete as directed and
specified by the deptt.
23.
11.
2 FGC 1 2X PLS /2P 9W, Philips
make) . or equivalent (Equivalent will
be selected by the deptt considering
the mother items rate) WIPRO/
JAQUAR make.
Each 35
Unit
Rate Total Amt Unit Rate Total Amt
Sl. offered( offered(R offered in offered in
No. Description of works Unit Qty. Rs) s) words words
7/2 Supply with fitting & fixing 60 mm dia
6.3 3660 mm height 2-in-one
combination double arm integrated
with acrylic diffusers, translucent top,
bottom clear , black powder painted
finish tubular pole .The pole is made
of GI tube with GI cylindrical control
box with service door and a circular
base plate . The pole is swaged at
the top to accommodate double arm
bracket assembly, secured on to the
top by means of 2 annular rings with
Allen grub screws .The luminaries is
designed for and integral with 2 nos
36 W CFL suitable for operation on
240 V 50 Hz single phase AC supply
. The pole is to be fitted on 1:3:6
PCC pole foundation of size 300
mmx300 mmx1200 mm with grouting
nuts & bolts as specified & directed
by the deptt .(Metal Coats
make).KALINGA-2 model or
equivalent. Each 30
8/3 Supply and laying of following size
2.1 PVC/XLPE insulated and PVC
sheathed 1.1 KV G Solid Aluminium
conductor up to 10 sq mm balance
stranded conductor, XLPE Insulated,
cores laid up, PVC tape inner
sheathed, Armour (Aluminium for
single core up to 70 sq mm balance
Aluminium strip, Galvanised for
cables up to 2x10 sq mm.3x10 sq
mm,4x6 sq mm balance all
galvanised steel strip) , extruded
PVC Type ST2 sheathed, 650/1100V
grade as per IS 7908(Part 1) 1988
armoured U.G. cable U.G. cable
laid in ground/partially in air (as
required for termination over ground
including excavation of cable trench
up to depth of 75cm, refilling,
protective brick covering, Sand
cushioning etc complete handling of
surplus spoil, debris et to proper
place as specified and directed by
the deptt. (Nicco/ Havells/
RPG/CCI/Polycab/Gloster/ Finolex
make) .
32.
1.1.
1 4.00mm2 2core U.G.Cable. mtr 200
Unit
Rate Total Amt Unit Rate Total Amt
Sl. offered( offered(R offered in offered in
No. Description of works Unit Qty. Rs) s) words words
9/3
2.5
Supply and laying of following size
Solid Aluminium conductor up to 10
sq mm balance stranded conductor,
XLPE Insulated, cores laid up, PVC
tape inner sheathed, Armour
(Aluminium for single core up to 70
sq mm balance Aluminium strip,
Galvanised for cables up to 2x10 sq
mm.3x10 sq mm,4x6 sq mm balance
all galvanised steel strip) , extruded
PVC Type ST2 sheathed, 650/1100V
grade as per IS 7908(Part 1) 1988,
LT armoured U.G. cable laid in pucca
flooring, road crossing, drain crossing
as per site requirement and partially
in air to connection as approved by
the Depts. the control switch,
through medium duty G.I. pipe (Tata/
Nezone make or equivalent as
approved by the Deptt) bend and
socket including excavation and
refilling the trench and making good
damage done as specified and
directed by the deptt. (Nicco/ Havells/
RPG/CCI/Polycab/Gloster/ Finolex
make)
Each 2
12/
36. Construction of 3 phase 11 KV Line
40 on 8.5 m PSC Pole using AAA
Raccoon conductor 7/3.81mm with T
cross arm average span 70m.
Km 0.50
13/
EC Supplying including installation,
6.2 testing and commissioning of Solar
Street light as per following
specification and as directed by the
Department.
a) 50 mm dia (Medium)
i) Using Tata make 226.0
R.M. 0
b) 40 mm dia (Medium)
f) 15 mm dia (Medium)
i) Using Tata make R.M. 86.00
2 Supplying fitting and fixing C.P. bib
cock 15mm dia of approved brand
directed and specified. (G.I. & C.P
pipes will be measured separately)
Jaquare make
(a)Continental /Clarion
(i)Standard Each 76.00
3 STOP COCK
Supplying fitting and fixing chrome
plated (C.P.) stop-cock of approved
brand and size as mentioned below
as directed and specified.(G.I. & C.P
pipes will be measured and paid
separately)
Unit Rate Unit Rate Total Amt
SL. UNI QUAN
DESCRIPTION OF ITEMS offered(R Total Amt offered in offered in
NO. T TITY
s) offered(Rs) words words
Jaquar
(i)15mm dia Male / Female (long
thread) Each 58.00
PUSH BIB COCK
Supplying fitting and fixing push bib
cock 15mm dia complete as directed
and specified as follows. (pipes will
be measured and paid separately).
a) C.P.C.H.
(a) Light type Each 22.00
(b) Heavy type Each 10.00
PILLAR COCK
4 Supplying and fitting fixing C.P. pillar
cock of 15mm dia of approved
brand as specified and directed.
Jaguar make
(a) Continental Each 28.00
(b)Long neck with areator
Each 12.00
Agmeco (classic)
Elbow action pillar cock (Agmeco)
(b) MS-491/ Heavy Duty
Each 12.00
5 SINK COCK
Supplying fitting and fixing Chrome
Plated (C.P.) sink cock of approved
brand as directed and specified. (G.I.
& C.P pipes will be measured and
paid separately)
Jaquar brand
ii) Sink cock with raised 'J' shaped
swinging spout
Each 10.00
VALVE
7 Supplying and fitting gun metal
country pit valve (full way valve)
I.S.I. Make as specified and
directed.
a) 50mm dia Each 10.00
8 Supplying and placing plastic
cylindrical vertical claused top
(PCVC) tank of Sintex / Polycon /
Patton make over the stagging with
manhole cover with locking and
cleaning arrangement including
providing pads of size as required
for inlet and outlet pipes
2000 Lt capacity
Unit Rate Unit Rate Total Amt
SL. UNI QUAN
DESCRIPTION OF ITEMS offered(R Total Amt offered in offered in
NO. T TITY
s) offered(Rs) words words
(a) Sintex make Each 6
PVC PIPE
SUPREME /PRINCE / FUSION /SFMC
Brand
vii) 160mm diameter Rm 200
12 Supplying, fitting and fixing suction
pipes plain/bevel ended,
conforming to relevant IS codes of
practice including supplying and
fitting of accessories, lowering of
assembly pipes concentrically in the
casing pipes complete as directed.
A) G.I. pipe
a) TATA / SAIL (Medium)socket
should be welded to the pipes.
iv) 50mm diameter Rm 200.0
Unit Rate Unit Rate Total Amt
SL. UNI QUAN
DESCRIPTION OF ITEMS offered(R Total Amt offered in offered in
NO. T TITY
s) offered(Rs) words words
13 Supplying fitting and fixing brass
Tez filter 2.00 metre long.
Each 8.00
14 Supplying fitting and fixing check
valve (non return valve) including
thread to pipes.
A. HYDRANT SYSTEM
1 Providing,Fixing, testing 18 each
&Commissioning of Single Headed Gun
Metal ISI Marked oblique pattern
Hydrant Landing Valve with 80 mm dia,
flanged inlet & 63 mm dia
instantaneous type female outlet
complete with cap and chain, twist
release lug and all accessories as per
IS:5290-19833 (Type-'A') and
specifications complete as reequired .
(MAKE:ESSEL/WINCO/NEWAGE)
8 1 each
13 Providing,Fixing,Testing &
Commissioning of Mild Steel Black
Pipe(IS:1239part-I) Heavy class including
cutting, screwing, welding etc.complete
with all fittings (butt welded) viz
flanges, bends, tees, elbows, reducers
etc including excavation (upto 1.5 m
Deep), back filling and removal of
surplus soil & providing anti corrosive
treatment(coating and wrapping) as per
IS:10221 with 4 mm thick tape complete
as reqd.
(MAKE:TATA/JINDAL/NEZONE)
27 10 each
Each
SL.No. Description Quantity Unit Unit Total
Rate Amt
Unit Rate Total Amt
offered offered
offered(Rs) offered(Rs)
in in
words words
EARTHING
34 Supply, installation & testing of Copper 2 Each
Plate earth station with 600 mmx600
mmx3 mm copper earth plate with
necessary 40 mm dia. G.I. medium duty
watering pipe with G.I. Fittings such as
Socket, Tee, elbow, nipple and 50
mmx40 mm G.I. reducing socket for
funnel including locking arrangement
with 300 mmx300 mmx6 mm C.I.
hinged cover plate complete with
digging of earth pit, construction of
brick chamber and plastering of both
inner & outer surface of wall as
specified and directed by the deptt .
35 2 Each
36
38 Supplying, installation of GI
PERFORATED cable tray on wall or from
ceiling including necessary channel, nuts
and bolts, washer etc. as required as
directed and specified by the
department. (LEGRAND/ AKG
/STRUTFAST make).
1 Earthwork
1.01
1.02
577.15
SL. DESCRIPTION OF ITEMS UNIT
No UNIT RATE TOTAL
TOTAL
RATE OFFE AMT
QUANTIT AMT
OFFER RED OFFERED
Y OFFERED(
ED(Rs in in
Rs)
UN ) WOR WORDS
IT DS
SHADE TREE
(D) Bottle Brush / Nil Gulmohar / each 250
Debadaru / Weeping Willow
SHRUB PLANTING
Supplying and planting of ornamental
shrub ( below 1'-0" height ) including
pit making ( 60 cm x 60 cm x 60 cm ),
filling the pit with appropriate soil
media, manure and fertilizers as per
specification and necessary
maintenance for a period of one year
from the date of planting complete as
specified and directed .
(A) Radhachura / Krishnachura / Rat ki each
rani / Ixora / Jetuka 125
MAIN GATE
Unit Total
Rate Amt
SL. DESCRIPTION OF Unit Rate Total Amt
UNIT QUANTITY offered offered
NO. ITEMS offered(Rs) offered(Rs)
in in
words words
1
Structural steel work
in sigle sections
including cutting,
hoisting, fixing in
position and applying
a priming coat of red
lead paint (up to
4.6m height) from
plinth level including
drilling holes,
supplying, fitting and
fixing with bolts and
nuts or welding, if
necessary as directed.
c) In M.S. angles,
channels, Tees etc.
(for Gates in Hospital
and others areas)
SHS 35X35X4.0
25 x 1.8 x 2 x 3.57
Qtl 3.57
RHS 60X40X3.0
8 x 3 x 4.25
Qtl 1.20
SQ BAR 20MM
30 x 1.8 x 2 x 3.14
Qtl 3.77
Unit Total
Rate Amt
SL. DESCRIPTION OF Unit Rate Total Amt
UNIT QUANTITY offered offered
NO. ITEMS offered(Rs) offered(Rs)
in in
words words
1 EARTHWORK
1.01
Earthwork in excavation
for foundation trenches
of walls, retaining walls,
footing of column, steps,
septic tank etc.
including refilling (return
filling) the quantity as
necessary after
completion of work,
breaking clods in return
filling, dressing,
watering and ramming
etc. and removal of
surplus earth with all
lead and lifts as directed
and specified in the
following classification of
soils including bailing
out water where
necessary as directed
and specified.
(A) Up to a depth of
2.00m below the
Cum 3.69
existing ground level
(a) In ordinary soil
2
PLAIN CEMENT
CONCRETE WORKS
Unit Rate Total Amt
Unit Rate Total Amt
SL. DESCRIPTION OF ITEMS UNIT QUANTITY offered in offered in
offered(Rs) offered(Rs)
NO. words words
2.01
3 REINFORCED CEMENT
CONCRETE WORKS
Unit Rate Total Amt
Unit Rate Total Amt
SL. DESCRIPTION OF ITEMS UNIT QUANTITY offered in offered in
offered(Rs) offered(Rs)
NO. words words
3.01
Providing and laying
plain/reinforced cement
concrete works in prop
1:1.5:3 (1 cement :1.5
coarse sand :3 graded
stone chips, 20mm
down) including
dewatering if necessary,
and curing complete but
excluding cost of form
work and reinforcement
for reinforced cement
concrete work (form
work and reinforcement
will be measured and
paid separately)
(i)In substructure up
to plinth level
Foundation, footing,
column with base, tie
and plinth beam, grade
beam, pile cap, base
slab, retaining walls, Cum 0.68
walls of septic tank,
inspection pit and the
like and other works not
less than 100mm thick.
3.02
4 FORM WORK
4.01
Providing form work of
ordinary timber planking
so as to give a round
finish including
centering, shuttering,
strutting and propping
etc. height of propping
and centering below
supporting floor to
ceiling not exceeding
4.0M and removal of the
same for in-situ
reinforced concrete and
plain concrete work in:
Unit Rate Total Amt
Unit Rate Total Amt
SL. DESCRIPTION OF ITEMS UNIT QUANTITY offered in offered in
offered(Rs) offered(Rs)
NO. words words
5 REINFORCEMENT
Unit Rate Total Amt
Unit Rate Total Amt
SL. DESCRIPTION OF ITEMS UNIT QUANTITY offered in offered in
offered(Rs) offered(Rs)
NO. words words
5.01
6 BRICKWORK
Unit Rate Total Amt
Unit Rate Total Amt
SL. DESCRIPTION OF ITEMS UNIT QUANTITY offered in offered in
offered(Rs) offered(Rs)
NO. words words
PLASTERING
Unit Rate Total Amt
Unit Rate Total Amt
SL. DESCRIPTION OF ITEMS UNIT QUANTITY offered in offered in
offered(Rs) offered(Rs)
NO. words words
B) On fair side
7 PAINTING
Unit Rate Total Amt
Unit Rate Total Amt
SL. DESCRIPTION OF ITEMS UNIT QUANTITY offered in offered in
offered(Rs) offered(Rs)
NO. words words
8.01
Supplying fitting and
fixing M.S.angles, M.S.
flat, M.S. bolts and nuts
including painting with
red lead paint one coat
complete as directed.
b) M. S. Flats……. Qtl
1.08