You are on page 1of 10

GAOTek Earth Resistance Tester with 2, 3

and 4-Pole Measurement Testing


GAO-ERT-101

GAOTek Earth Resistance Tester with 2, 3 and 4-


Pole Measurement Testing is specially designed
and manufactured for the measurement of earth
resistance, soil resistivity, earth voltage, and AC
voltage. Adopting the latest digital and micro-
processing technology, specifically, 4-pole, 3-pole
and simple 2-pole measurement method for earth
resistance measurement, importing FFT and AFC
technology.

The unique functions of anti-interference capability, ability to adapt to the environment and
consistency of repeat testing makes it capable of high precision, high stable and reliable for
prolonged measurement. It is widely used in electric power, telecommunications,
meteorology, oil field, construction, lightning protection, industrial electrical equipment and
other earth resistance, soil resistivity, earth voltage, AC voltage measurement.

APPLICATIONS

❑ Measurement of earth resistance.

❑ Measurement of soil resistivity.

❑ Measurement of AC voltage.

❑ Used in electric power, telecommunications, meteorology, oil field, construction,


lightning protection, industrial electrical equipment and other earth resistance, soil
resistivity, earth voltage, AC voltage measurement.

Rukan CROWN Blok H no.9, Jl. Boulevard Green Lake City - Tangerang 15147
Telp./Fax: +6221 2254 3224 │ sales@multiinovasiteknologi.com │ www.multiinovasiteknologi.com
GAOTek Earth Resistance Tester with 2, 3 and 4-Pole Measurement Testing
GAO-ERT-101

KEY FEATURES

❑ 4-digit large LCD display, blue screen backlight suitable to work in dim light places.

❑ Measurement of earth resistance, soil resistivity, earth voltage, and AC voltage.

❑ 2-pole, 3-pole, and 4-pole earth resistance measurement mode.

❑ 300 sets of data storage.

❑ LED flash indicator, LCD count down display, and progress bar indicator.

❑ Alarm setting; Data lock and storage function; Data reading and deletion function.

❑ Recognize interference signal automatically.

❑ RS232 interface for data monitoring through software; storage data can be uploaded
and saved to computer.

❑ Replaceable Zi-Mn dry battery, 300 hr continuous standby time.

Rukan CROWN Blok H no.9, Jl. Boulevard Green Lake City - Tangerang 15147
Telp./Fax: +6221 2254 3224 │ sales@multiinovasiteknologi.com │ www.multiinovasiteknologi.com
GAOTek Earth Resistance Tester with 2, 3 and 4-Pole Measurement Testing
GAO-ERT-101

PRODUCT DESCRIPTION

1. LCD 7. C(H) interface: Current electrode


2. Button area 8. E interface: Earth electrode
3. Rotary switch for selecting 9. ES interface: Auxiliary earth
function electrode
4. RS232 interface 10. Standard test wires
5. Interface of testing wires 11. Auxiliary earthing rods
6. P(S) interface: Voltage electrode 12. Simple test wires
GAOTek Earth Resistance Tester with 2, 3 and 4-Pole Measurement Testing
GAO-ERT-101

TECHNICAL SPECIFICATIONS

General Specification

Measurement of 2/3/4-pole earth resistance, soil resistivity,


Function
earth voltage, AC voltage

DC 9 V (Zi-Mn dry battery R14S 1.5 V 6 Pcs, continuous standby


Power Supply
for 300 hours)

Earth Resistance: 0.00 Ω-30.00 kΩ


Measurement Range
Soil Resistivity: 0.00 Ωm-9000 kΩm

4-pole measurement, 3-pole measurement, simple 2-pole


Measuring Mode
measurement

Earth Resistance: rated current change-pole method,


measurement current 20 mA Max
Measuring Method
Soil Resistivity: 4-pole measurement (Wenner method)
Earth Voltage: average rectification(between P(S)-ES

Test Frequency 128 Hz / 111 Hz / 105 Hz / 94 Hz (AFC)

Short-circuit Test Current AC 20 mA max

Open-circuit Test Current AC 40 V max

Test Voltage Wave Sine wave

Electrode Distance
Can be set 1 m-100 m
Range

Rukan CROWN Blok H no.9, Jl. Boulevard Green Lake City - Tangerang 15147
Telp./Fax: +6221 2254 3224 │ sales@multiinovasiteknologi.com │ www.multiinovasiteknologi.com
GAOTek Earth Resistance Tester with 2, 3 and 4-Pole Measurement Testing
GAO-ERT-101

TECHNICAL SPECIFICATIONS

Earth Resistance: 0.00 Ω-30.00 kΩ, automatic shift


Shift
Soil Resistivity: 0.00 Ωm-9000 kΩm, automatic shift

Backlight Blue screen backlight, suitable for dim light places

Display Mode 4-digital large LCD display, blue screen backlight

LED flash indicator, LCD count down display, progress bar


Measuring Indicator
indicator

LCD Frame Dimension 5.03 in × 2.95 in (128 mm × 75 mm)

LCD Window 4.88 in × 2.63 in (124 mm × 67 mm)

Standard Test Wire 4 wires: red 20 m, black 20 m, yellow 10 m, and green 10 m

Simple Test Wire 2 wires: red 1.6 m and black 1.6 m

Auxiliary Earthing Rod 4 rods: Φ 0.39 in × 5.90 in (10 mm × 150 mm)

Earth voltage: about 3 times/second


Measuring Rate
Earth resistance, soil resistivity: about 5 seconds/time

Over 5000 times (Short-circuit test, interval time should be at


Measuring Times
least 30 seconds)

Line Voltage Below AC 600 V

Rukan CROWN Blok H no.9, Jl. Boulevard Green Lake City - Tangerang 15147
Telp./Fax: +6221 2254 3224 │ sales@multiinovasiteknologi.com │ www.multiinovasiteknologi.com
GAOTek Earth Resistance Tester with 2, 3 and 4-Pole Measurement Testing
GAO-ERT-101

TECHNICAL SPECIFICATIONS

Possess RS232 interface, software supervision, storage data can


RS232 Interface
be uploaded to computer, saved or printed.

Communication Wire RS232 communication wire, with length 1.5 m

300 sets, “MEM” icon storage indicator, flash display “FULL” icon
Data Storage
to indicate storage is full

Data Hold Data hold function: “HOLD” icon display

Data Access Data read function: “READ” icon display

Overflow Display Exceeding measuring range overflow function: “OL” icon display

Recognize interference signal automatically, “NOISE” icon display


Interference Test
when interference voltage exceed 5 V

Auxiliary Can measure auxiliary earth resistance, 0.00 KΩ-30 kΩ (100 R + rC


Earthing Test < 50 kΩ, 100 R + rP < 50 kΩ)

When measuring value exceeds alarm setting value, there is “Toot-


Alarm Function
toot-toot” alarm hint

Measuring earth resistance: between each interfaces of C(H)-E,


Overload Protection
P(S)-ES, AC 280V/3 seconds

Insulation Resistance Over 20MΩ (between circuit and enclosure it is 500V)

Withstanding Voltage AC 3700V/rms (Between circuit and enclosure)

Electromagnetic
IEC61326(EMC)
Features

Rukan CROWN Blok H no.9, Jl. Boulevard Green Lake City - Tangerang 15147
Telp./Fax: +6221 2254 3224 │ sales@multiinovasiteknologi.com │ www.multiinovasiteknologi.com
GAOTek Earth Resistance Tester with 2, 3 and 4-Pole Measurement Testing
GAO-ERT-101

TECHNICAL SPECIFICATIONS

IEC61010-1 (CAT Ⅲ 300V, CAT IV 150V, Pollution 2),


Protection Type IEC61010-031, IEC61557-1 (Earth resistance),
IEC61557-5 (Soil resistivity), JJG 366-2004

Standby: approx 20 mA (Backlight shut off)

Boot and with backlight: approx 45 mA (25 mA without


Power Consumption
backlight)

Measurement: approx 100 mA (Backlight shut off)

Working Temperature &


14 ℉ - 104 ℉ (-10 ℃-40 ℃), below 80% RH
Humidity

Storage temperature & humidity -4 ℉-140 ℉ (-20 ℃-60 ℃), below 70% RH

Dimension (L×W×H) 8.46 in × 7.48 in × 3.74 in (215 mm × 190 mm × 95 mm)

Total weight: 9.92 lbs (4.5 kg) (including package)

Tester: 3.181 lbs (1443 g) (including battery)


Weight
Testing wires: 3.43 lbs (1560 g)

Auxiliary earthing rods: 2.06 lbs (935 g) (4 pcs)

Rukan CROWN Blok H no.9, Jl. Boulevard Green Lake City - Tangerang 15147
Telp./Fax: +6221 2254 3224 │ sales@multiinovasiteknologi.com │ www.multiinovasiteknologi.com
GAOTek Earth Resistance Tester with 2, 3 and 4-Pole Measurement Testing
GAO-ERT-101

TECHNICAL SPECIFICATIONS

Base Conditions and Working Conditions

Working
Influence Quantity Base Condition Remark
Conditions

73.4 ℉±33.8 ℉ (23 14 ℉-104 ℉ (-10


Ambient Temp ----
℃ ± 1 ℃) ℃-40 ℃)

Ambient Humidity 40%-60% 40%-60% ----

Working Voltage 9 V±0.1 V 9 V±1.5 V rC, rP

Auxiliary Earth Resistance <100 Ω <30 kΩ ----

Interference Voltage No <20 V ----

Interference Current No <2 A ----

Electrode Distance when


a>5 d a>5 d ----
measuring R

Electrode Distance when


a>20 h a>20 h ----
measuring ρ

Rukan CROWN Blok H no.9, Jl. Boulevard Green Lake City - Tangerang 15147
Telp./Fax: +6221 2254 3224 │ sales@multiinovasiteknologi.com │ www.multiinovasiteknologi.com
GAOTek Earth Resistance Tester with 2, 3 and 4-Pole Measurement Testing
GAO-ERT-101

TECHNICAL SPECIFICATIONS

Intrinsic error and performance indicators under base conditions

Category Measurement Range Intrinsic Error Resolution

0.00 Ω - 30.00 Ω ±2% rdg ± 3 dgt 0.01 Ω

30.0 Ω - 300.0 Ω ±2% rdg ± 3 dgt 0.1 Ω


Earth Resistance
(R)
300 Ω - 3000 Ω ±2% rdg ± 3 dgt 1Ω

3.00 kΩ - 30.00 kΩ ±4% rdg ± 3 dgt 10 Ω

0.00 Ωm - 99.99 Ωm 0.01 Ωm

100.0 Ωm - 999.9 Ωm 0.1 Ωm

1000 Ωm – 9999 Ωm According to the 1 Ωm


Soil Resistivity
precision of R
(ρ)
(ρ=2πaR; a:1 m-100m,
10.00 kΩm - 99.99 kΩm π=3.14) 10 Ωm

100.0 kΩm - 999.9 kΩm 100 Ωm

1000 kΩm – 9000 kΩm 1 kΩm

Earth Voltage ±2% rdg ±3 dgt ±2% rdg ±3 dgt 0.1 V

Rukan CROWN Blok H no.9, Jl. Boulevard Green Lake City - Tangerang 15147
Telp./Fax: +6221 2254 3224 │ sales@multiinovasiteknologi.com │ www.multiinovasiteknologi.com
GAOTek Earth Resistance Tester with 2, 3 and 4-Pole Measurement Testing
GAO-ERT-101

PACKAGING LIST

Sr. No. Item Description Quantity

1 GAOTek Earth Resistance Test unit 1

2 Tester Bag 1

3 Auxiliary Earthing Rod 4

Standard testing wire (4 wires: Red 20 m, Black 20


4 4
m, Yellow 10 m, and Green 10 m)

Simple testing wire (2 wires: Red 1.6 m and Black


5 2
1.6 m)

6 Zinc-manganese Dry Battery (R14S 1.5 V) 6

7 Monitoring Software Disk 1

8 RS232 Communication Cable 1

9 Manual/Warranty Card/Qualification Certificate 1

Rukan CROWN Blok H no.9, Jl. Boulevard Green Lake City - Tangerang 15147
Telp./Fax: +6221 2254 3224 │ sales@multiinovasiteknologi.com │ www.multiinovasiteknologi.com

You might also like