You are on page 1of 2

Falling film Evaporators systems

Wetting rate range 500 to 600 kg/hr/m The optimum value varies from 500 to 600 Kg/hr/m

Tube diameter 1.5 inch


Tube diameter 0.0381 m

Wetting rate considered 500 kg/m/hr

Flow rate through tube 19.05 Kg/hr

Tube length 2000 mm 2m

Process Temp 100 C


Steam temp 115 C

delT 15 C
Area for heat transfer 0.238506 m2

Overall U 800 W/m2C (based on correlations)

Heat duty 2862.072 W

latent heat 2259360 J/kg (540*4184)

Water evaporated from one tube 0.001267 Kg/s


4.560344 Kg/hr

Desired evaporation rate 200 Kg/hr

No. of tubes 43.85634 44

Total liquid circulation rate 838.2 Kg/hr


varies from 500 to 600 Kg/hr/m of circumference of tubes , to a maximum of 1200 to 1500 Kg/hr/m