You are on page 1of 1

Method of calculation

Reactor GPA-9413
Initial volume 4 M3
L/D 1.199689
Reactor diameter 1.619474 m 4000 Lts Operating 4000 Lts
Reactor Volume
Height of the liquid in the reactor 1.942865 m 4 M3 Volume 4 M3
Initial available heat transfer area 10.29781 m2 440 Lts
Dish Volume
Heat transfer coefficient 250 Kcal/m2 °C-hr 0.44 M3
Process fluid temperature 115 °C Reactor Diameter 1.619474 M
Hot water utility inlet temperature 125 °C Height 1.943368 M
Hot water utility outlet temp 120 °C Operating Height 1.942865 M
Delta T mean 7.5 °C Total Heat Transfer Area 10.29408 M2
Latent heat of the MDC 82 Kcal/Kg Condeser Area 15.44112 M2
Density of the MDC at STP 0.8 Kg/Lit Available Condeser area M2
Boil up rate 294.3352 Lit/Hr
388.5225 kg/hr

Heat load 19308.39 Kcal/hr Flow rate


Cp of water 1 Kcal/Kg°C flow 2 m/sec
Brine inlet temp -10 °C t1 line size 1.5 inch
Brine outlet temp -8 °C t2 line size 0.04 m
Brine Pressure Kg/cm2 A 0.001256 m2
Del T 2 °C Q 0.002512 m3/sec
Mass flowrate required 9654.196 Kg/hr Q 9.0432 m3/hr
Mass flowrate required 9654.196 lit/hr
Mass flowrate required 2681.721 ml/sec

10 T1
5 T2
LMTD 18
16.4544448432412 15
Q UALMTD
31858.8463884904
A 7.744739

You might also like