You are on page 1of 8

Ta 0 °C

Pa 0.98 bar
Xa 9260 %
Ha 2435 kJ/kg
𝑚 ̇ 17.34611 kg/s

Evaporator

Tb 0.00000 °C T5
Pb 0.98 bar P5
Xb 0 % X5
Hb 0 kJ/kg H5

Working Fluid :
isopentane

Pre-Heater

Tc 0 °C
Pc 0.98 bar
Xc 0 %
Hc 0 kJ/kg T4 98 °C
P4 6.3378205 bar
X4 0
H4 200 kJ/kg
𝑚 ̇ 45 kg/s
Fluid isopentane water
Unit SI with C

A B C 1 2s 2
T(°C) 81 87 92
P (bar) 0.98 0.98 0.98 6.337821 1.3967623 1.396762
P (Mpa) 0.098 0.098 0.098 0.633782 0.1396762 0.139676
X 92.6 1 1 1
H (kJ/kg) 2435 200 200 200
S (kJ/kg.K) 2.5056 2.3232 22209
𝑚 ̇ (kg/s) 17.3461111 17.346111 17.34611 45 45 45

Evaporator Turbine
Qab 0 kJ/s Wt 0
ηthermal #DIV/0! Hi 200
Pre Heater Hos 200
Qbc 0 kJ/s η 90%

maxQ #NAME? Pump


ηeva 1 Wp 0
ηph 1 η 80%
T1 81 °C
P1 6.337821 bar
X1 100 %
H1 200 kJ/kg Wt 0 MW

Turbine Generator

T2 87 °C
P2 1.396762 bar Tcwi 27.45
X2 1 Pcwi 0
H2 200 kJ/kg Xcwi 0
Hcwi 0
𝑚 ̇ 0

102 °C
6.337821 bar
0 %
200 kJ/kg
Condenser

Working Fluid :
isopentane

T3 95 °C
P3 1.396762 bar
X3 0 %
H3 200 kJ/kg

Wp 0 MW
Tambient 27.45 C
Pambient 0.0939888 Mpa <-- 705.01 mmHG

3 4s 4 5 air in air out


95 98 100 102 27.45 90 62.55
1.396762 6.337821 6.337821 6.33782052
0.139676 0.633782 0.633782 0.63378205
0 0 0 0
200 200 200 200
21506 21506 20977 20555
45 45 45 45 0 0

Pinch Point Condenser


Tpp ### Q 0 kJ/s

Generator
η 97%
Wgen 0

Air Cooled Fan


m 0
Wfan 0
°C
bar Cooling
%
Tower
kJ/kg
kg/s

Tcwo 90 °C
Pcwo 0 bar
Xcwo 0 %
Hcwo 0 kJ/kg

You might also like