Sr.

No.
Parameter Unit ML Tank Remarks
1 Required working volume m 15
2 Diameter, D m 2.1
3 TL-TL, L m 4.5
4 Orientation Horizontal 2.14
5 dish end type Torispherical dished
6 Dished depth m 0.41
7 Normal Liquid Level m 1.47
8 Max Liquid Level m 1.79
9 Full Liquid Level 2.10
10 Volume up to Normal Liquid Level (Working or Hold Up Volume) m 12.83
11 Volume up to Max Liquid Level m 15.53 Note-2, 3
12 Net Volume Volume m 17.08
13 Check OK
14 margin over Working Volume % 17.38
Basis
1 Margin over Working Volume (Sr No 15) = 100 - 100*(Volume up to Normal Liquid Level ( Sr No 10)/Volume up to max liquid level (Sr No 11)
2 Working Volume is considered up to Max Level as this equipment is not meant to L-V separator.
3 Max Level will not be used for Alarm set value, HL set point can be taken Max Level + 100 mm