About Us

ABOUT US
Coolnet Power, the leading provider of
critical power supply and cooling system,
specialized in the manufacturing of
Precision Air Conditioner, Uninterrupted
Power Supply (UPS) and Data Center
Solution products in China.

Focus On Product Line


Coolnet has always been focusing on the IDC and Our products line range from Thermal management
telecommunication infrastructure solutions for solution(Computer room precision air conditioner, Base
decades, with rich research and manufacturing station precision air conditioner, In-row precision air
experience in data center equipment field, having conditioner, etc. ), Modular data center and power
world class labs, production inspection equipment management solutions (Uninterrupted power supply
and complete computer room key equipment line. system ). Mini Data Center and Container data center.

4
1
Part
Company Introduction
Events

Coolnet cooperated with the Saudi Arabia


Coolnet was founded in China focus on telecommunication and provide IDC Coolnet develop and Export
IDC solution products .........
data center climate solution . Products and DC power supply

2012 2014 2016 2018 2020 2022 2023

Coolnet Establishing a joint


Coolnet Start UPS
venture in Dubai
production.

5
1
Part
Company Introduction
Techno Strength

Foundation:
The factory covers an area of 21,000 square meters with a floor height of 25
meters. It has a sheet metal workshop, assembly workshops, a painting
workshop, an assembly workshop, an inspection center, and a testing center.
.Output: The factory provides data center full life cycle product solutions,
infrastructure equipment manufacturing Current annual

Output: 15,000 units/year of precision air conditioners, 10,000 units/year of UPS,


6,000 units/year of telecom power products, 12,000 units/year of cabinets,
1,500 units of micro modules Sets/year and products.

Personnel: The factory has a top precision air-conditioning R&D team,


R&D Platform UPS R&D team, and micro-module product R&D team; all production
leaders have more than 10 years of experience in the industry

6
1
Part
Company Introduction
Factory

Automatic digital bending Automatic Digital Punch Automatic Laser Cutting


Automatic bending robot
金方圆自动数字折弯设备 equipment System System

Advanced R&D Testing Automatic vertical tube


Automatic spraying Laboratory expander Assembly line

7
1
Part
Company Introduction
Factory

Diversified Product
Sheet Mental
金方圆自动数字折弯设备 Printing Evaporator & Condenser PAC Assembly Assembly

Power Distribution Enthalpy Difference UPS、 Power


Workshop Laboratory Distribution Laboratory Quality Inspection Center Warehouse

8
1
Part
Company Introduction
Certificate

Certificate of Certificate for China Energy Saving ISO Occupational ISO Environment ISO Quality
Compliance Compulsory Product Certificate Health
Certification

9
1
Part
Company Introduction
Partners

10
02
Product Introduction
2
Part
Product Introduction
Product Introduction

PA C UPS Battery

Power Supply &


Distribution
MDC Intelligent Monitor

12
2
Part
Product Introduction
Cool-Smart Series Precision Air Conditioning

Introduction
Introduction>>

The Cool-smart Series Computer Room Air Conditioner Is Designed For Small And
Medium-sized Computer Rooms, Base Stations, Equipment Rooms, Etc., Micro-cool Has
The Characteristics Of High Air Volume And Small Enthalpy With High Reliablity , High
Efficiency, Long Working Life And Energy Saving Advantages.

Features Applications

l Various cooling forms u IT Equipment Room


l Various air supply forms u Small Data Center
l High Energy efficient u Industrial Clean Room
l Cooling Capacity :4-20KW u Laboratory
u Electric Power Equipment Room
u Railway Subway Machine Room
u Base Station and Small Telecom Switch Room
u Medium &Small Telecom Switch Room

13
2
Part
Product Introduction
Cyber Master Series Precision Air Conditioning

Introduction
Introduction>>
Cyber Master Series precision air conditioning is specially designed for data centers,
telecommunication equipment rooms equipment and other application scenarios that
require precise environment with constant temperature and humidity. continuously
operation 24 hours*265 days. Cabinet structure design, cooling capacity range 4-200kW,
air cooled or chilled water cooled, widely installed for small, medium and large data
centers.

Features Applications

l Various cooling forms u Computer Room and Data Center (IDC)


u Switch room and mobile room
l Various air supply forms
u High-tech environment and laboratory
l High Energy efficient
u Industrial Control Room
l Cooling Capacity :20-120KW u 5G communication base station
u Machining Equipment
u Standard testing room
u UPS and battery room
u Biochemical culture room
u Hospitals and Testing Rooms

14
2
Part
Product Introduction
Lab High Precision Series Precision Air Conditioning

Introduction
Introduction>>
Coolnet Cyber Master HP Series high-precision Lab air conditioner is developed to meet
the high-precision temperature and humidity requirements in special environments. The
temperature control accuracy reaches ±0.2°C, and the humidity control accuracy reaches
±2%. It can be widely used in precision instrument laboratories, textile workshops, paper
workshops, tobacco companies, archives, etc.

Features Applications

l Ambient temperature control accuracy u precision laboratory


reaches ± 0-2°C, and the humidity control u Textile workshop
accuracy reaches ± 2%. u Tobacco workshop
l EC Fan and Inverter Compressor u paper workshop
l 7-inch TFT true color touch screen, friendly
man-machine interface, convenient
operation.
l High Energy efficient

15
2
Part
Product Introduction
In-row Precision Air Conditioning

PA C Introduction
Introduction>>
Cool Row Series Precision Air Conditioning is a row-level cooling solution for data centers
requires higher density and higher efficiency, The air conditioning unit and the server are
arranged in parallel and arranged between the servers. Since it is closer to the heat load,
the energy consumption of air supply will be greatly reduced, Effectively reduce the PUE of
data center, In-row structure design, cooling capacity range 12-60kW, air cooled or chilled
water cooled, dedicated design for micro data centers.

Features Applications
Power Supply &
Distribution
l Close to the Heat Resource u Data center (IDC)
l Electronically Commutated Compressor u High heat density computer room
l EC Fan u Modular Data Center
l Electronic Expansion Valve u container data center
l Cooling Capacity :13-60KW

16
2
Part
Product Introduction
Rack Mounted Precision Air Conditioning

PA C Introduction U>>
IntroductionPS
Cool Rack series rack-mounted air conditioner is a cabinet-level temperature control
product specially designed for integrated cabinets data center, modules data center or
high heat density data centers. It can be placed in the cabinet close to the heat source
and can accurately handle the output of the equipment in the cabinet. The high sensible
heat can effectively prevent the generation of local hot spots, reduce the return air
distance, increase the return air temperature, and improve the energy efficiency ratio.

Power Supply &


Distribution Features Applications

l High-efficiency inverter compressor u Integrated cabinet


l EC centrifugal fan u Single row cabinet
l R410A environmentally friendly u Micro Rack Data Center
refrigerant design u Medium and high heat density computer room
l standard electronic expansion valve u Modular Data Center
u IT Rack for Blade Servers

17
2
Part
Product Introduction
Rack Data Center & MDC

Rack Data Center


Micro Min DC MDC
(All-in-one Cabinet)

18
2
Part
Product Introduction
Micro Data Center

Introduction U>>
IntroductionPS
The Micro Data Center is also called the intelligent cabinet or the integrated All-in-one
cabinet. It is a highly integrated intelligent, including the power supply system,
intelligent The environment maintains constant temperature and humidity. It is
configured with access control and cabinet door status monitoring systems, as well as
remote centralized control and other functions.

Advantages

• Construction: it can realize plug-and-play in the true sense and rapid deployment.
• Cooling efficiency: rack-mounted air conditioners are used to isolate the impact of
external space
• Appearance: Air conditioner, UPS, power distribution, etc. are integrated inside,
the cabinet door is made of transparent glass, and the built-in ambient light is
convenient for observing the status of the equipment.

19
2
Part
Product Introduction
Micro Data Center Product Categories

Multiple racks

Single Rack

20
2
Part
Product Introduction
Design Features for Single Rack

42U Standard IT Rack

Power Distribution Module Power


Distribution
IT Server
Controller+Display

P IT Server P
Rack-
42URack D IT Server D
mounted U U
PDU IT Server
IT Server Servers,
1U Blank Panel Network
UPS
1U Blank Panel
Battery
Power
S Distribution
e Module
n 3/6kW UPS
Rack-mounted PAC o UPS
Microenviron Sr 2U Battery Pack Battery
ment se
n Rack-mounted
monitoring ss PAC
PAC
o
r

21
2
Part
Product Introduction
Design Features of Multiple racks

Hot Aisle
Cold Aisle

Controller+Display
42URack

Power Distribution Module

UPS

Battery

Rack-mounted PAC /In-row PAC

22
2
Part
Product Introduction
Micro Data Center Components

Micro data center with accessories

NO Components Specification Remark

1 ATS Power Distribution Unit <125A,6-10U

2 Standard Power Distribution Unit Total input: 125A,10-way,3-12U


8-24 ports, standard configuration of each specification,
3 PDU
among which 8 ports are horizontal PDUs
4 UPS 3-6kva: 2U,10-30kva:3U

5 Battery pack Configure according to needs

6 PDU mounting plate Standard is fixed

7 Rail 60KG
8 Laminate 60-150KG

23
2
Part
Product Introduction
MDC Product

Introduction U>>
IntroductionPS
MDC is a commonly used overall solution for current data center construction. It is
highly integrated. A single MDC can include cabinets, closed passages, power supply
and distribution, cooling, DCIM, and wiring systems. One module can meet all the
basics for the stable operation of IT loads.

Advantages

• Construction: configure according to needs, save investment in the computer room,


and reduce costs.
• Cooling efficiency: use inter-column air-conditioning to completely isolate hot and
cold air, reduce air-conditioning power consumption, avoid local hot spots, reduce
cooling dissipation, and reduce PUE value
• Product delivery: factory prefabrication, fast splicing on site, plug and play, fast
deployment and payment
• Appearance: racks, air conditioners, UPS, power distribution, etc. adopt a unified
style and size, beautiful and tidy

24
2
Part
Product Introduction
MDC Product Categories

Dual-row
Single

25
2
Part
Product Introduction
MDC-Rack Production
The weld seam is neat and uniform, without defects such as cracks, undercuts, gaps, burn-
through, etc. The appearance of the weld seam has no defects such as slag inclusions, pores,
dry spots, pits, etc. After welding, it is polished, and the surface roughness meets the relevant
industry standards.

The surface of the coating layer of The standard color of the cabinet is
the cabinet is smooth and clean, black RAL9005, matte, and there is
with uniform color, no sag, and no no dizziness under the light of the
exposed bottom. Metal parts have cabinet. Other colors can be
no burrs and no rust. All parts have customized.
no sharp edges and corners, which
The surface of the cabinet is treated
can avoid harm to the human body.
with degreasing, pickling, anti-rust
The cabinet door and side panels phosphating, pure water cleaning,
are flat, without distortion, electrostatic spraying, etc., without
deformation, or obvious vibration;
the door panels have even
02 paint stripping, acid and alkali
resistance, solvent resistance,
openings. corrosion resistance, not affected by
hand sweat, adhesion 100%, anti-
The cabinet and its accessories, corrosion Shock, safety protection up
coatings, signs, decorations, etc. to IP20 standard.
are all made of flame retardant The surface spraying of the outer
and non-combustible materials. parts conforms to the European
ROSH standard and meets the
Surface treatment adopts professional high-hardness powder electrostatic national non-toxic and harmless
spraying to ensure anti-static and BS6497 international standards. The spraying standard.
surface spray thickness reaches 70-130µm. No blisters, no cracks, no
orange peel, no burrs and modifications on metal parts, anti-static.

26
2
Part
Product Introduction
MDC-Rack Structure

• H series server cabinet


• High-strength and high-quality cold-rolled steel plate
is used, and the whole cabinet adopts a welded structure
of bent column frame

① The cabinet frame adopts 2.0 thick plate, fully


welded structure
② Front door assembly
③ Mechanical lock
④ Right rear door
⑤ Left rear door
⑥ Top panel
⑦ Side panels
⑧ Bottom plate
⑨ Column
⑩ Vertical cable management board

27
2
Part
Product Introduction
Modular Data Center Rack Specification

Rack Series Dimension Configure Load-bearing

Standard 19-inch cabinet, the front


door is a single-opening glass door,
600×1200/1400×2000 the rear door is a single-opening Max Weight capacity
Sigle Rack
(42U) sheet metal door, and a single 2100KG
cabinet body. Includes support feet
and casters.

Standard 19-inch cabinet, the front


door is a single-opening glass door,
800×1200/1400×2000 the rear door is a single-opening Max Weight capacity
Single Rack
(42U) sheet metal door, and a single 2100KG
cabinet body. Including support feet,
casters

28
2
Part
Product Introduction
MDC-Rack Dimension & Configuration

Dimension W: 600mm/800mm D: 1000mm/1100mm/1200mm H: 2000mm/2200mm

Top Bottom Parallel Side Cable management


Panel Panel cabinets panel board

29
2
Part
Product Introduction
Rack Other parts

Blank panel Laminate panel

Brush cable management Rails

30
2
Part
Product Introduction
MDC Components

Movable H-type Line Cabinet


skylight trunking Ladder base

(1) The built-in lighting system of the flip sunroof has an LED lighting strip on each side
(2) The H-type trunking integrates three slots of strong, weak current and optical fiber, and the number of slots can be modified
according to requirements, and the width of the slot can be adjusted.
(3) The jumping ladder between columns adopts a splicing structure and is used for cable jumping of double-row channels.
(4) The assembled base bracket is convenient for transportation and free of welding, which can help rapid construction and equipment
placement on site.

31
2
Part
Product Introduction
MDC Components

Skylight Decorative MDC controller


support plate hoarding

(1) The skylight support plate has a built-in ambient light, which can be replaced with the decorative panel at the rear of the cabinet.
(2) The MDC controller integrates end doors, lighting power supply, skylight, ambient light control, and fire protection linkage functions, and
can open the sunroof with one key.

32
2
Part
Product Introduction
MDC Components

Aisle end door

(1) Ambient lights are embedded in the passage end door, and the door head is equip a
laser-cut color-changing LOGO lintel.

33
2
Part
Product Introduction
MDC Design Features

Row ladder Aisle skylight

Skylight support
H-type trunking
panel

Decorative
hoarding LOGO

IT Racks Controller
Display

Frameless
In-row AC glass

Rack base Aisle end door

34
2
Part
Product Introduction
MDC Components

NO Components Specification Remark

1 Cabinet and cabinet parts Standard cabinet accessories for easy installation

2 L-shaped rail Carrying equipment without rails, divided into left and right pairs

It is used to isolate the hot and cold airflow inside the cabinet to prevent the airflow disorder in the cabinet, 1U
3 1U blank plate
tool-free installation
It is suitable for 1200mm depth racks, the load-bearing capacity is not more than 100KG, and the color is
4 Fixed shelf
consistent with the cabinets.

5 Cable management Installed directly on the mounting hole of the U column, used to manage horizontal cables, used with switches

Vertical cable management, installed vertically at the rear of the cabinet, the current cabinet is equipped with 2
6 Vertical cable management board
by default, mainly for installing PDUs

7 Cable slot on the top of the cabinet H-shaped channel, can be divided into strong current, weak current, optical fiber

10 In-row cable ladder Across the channel, for in-row routing

11 Rack base Standard 300 high

Flip all-glass skylight with 95% light transmittance and built-in lighting module. This type of skylight does not
12 Movable skylight
need to be equipped with lamps. It is equipped with a 600-wide cabinet

13 Side doors Block the glass door and install a large screen to increase the aesthetics

14 Modular UPS Host 90-300KVA Modular UPS with standard 30KVA module

15 PDU 10+4 16+4 20+4

35
03
Projects Introduction
3
Part
Projects Introduction
Coolnet Case

Telkom Indonesia
Project Background: Telkom Indonesia is Indonesia’ s largest
state-owned telecom company and the global communication
service provider. Since 2010, Coolnet has started the
cooperation with Telkom Indonesia and appoint Coolnet as the
only provide of the precision cooling system for 10 years,
Annual purchase quantity is 50 sets.
Project Configurations: 12.6KW Precision Cooling System
15.6KW Precision Cooling System 31.5KW Precision Cooling
System

Project Summary: Coolnet precision air conditioning was


widely used in Indonesia’ s communication computer room all
ov er t he count r y, Hi g h e ff i c i e n c y a n d e n e r g y s a v i n g
configuration can meet the energy conservation and emission
reduction policy for communication operators. According to
local climate characteristics, combined with Coolnet’ s many
years of lightening protection product research and
development strength, successfully resolved the earthquake,
the thunder and lightning protection technology problem.

37
3
Part
Projects Introduction
Coolnet Case

Oman Oil company


Project Background: Oman Oil company (OOC) was
established in 1992 by Oman government, wholly owned by
Oman Government, Looking for energy investment opportunities
on behalf of the Oman government in Oman domestic and
overseas. Oman Oil Company not only do the investment of
Oman domestic oil and gas resources project, but also has a
wide range of investment on petroleum and natural gas, mining,
processing and transportation in the whole Middle East, Europe
and Central Asia.
Project Configuration: 12.6KW Precision cooling system
15.6KW Precision cooling system

Project Summary: This cooperation reflect Coolnet strong


strength of long - term service for energy industry, boost Coolnet
good service and innovation development in international
petroleum and petrochemical industry. At
the same time, Research and development team breakthrough
technical problems to make the equipment adapt the High
temperature desert climate in order to meet the needs of
customers.

38
3
Part
Projects Introduction
Coolnet Case

Metropolitan Medical Center

Project background : The Metropolitan Medical Center (MMC)


is a major private hospital located in the Chinatown area of the
city. The hospital is licensed by the Government of the Philippines.
The MMC is bases in a 27-storey medical tower, and is fully
equipped with diagnostic equipment and a fully automated
diagnostic laboratory.

Project summary : According to the development of MMC,


Coolnet provides 4 sets of 70KW Precision air conditioning to
ensure the constant temperature and hum idit y wor k ing
environment, Guarantee the stable working of Medical
equipment.

39
3
Part
Projects Introduction
Coolnet Case

Fluor USA

Project background : Fluor company was founded in 1912 in


the United States, its a leading engineering construction
company, provides engineering, procurement, construction
(EPC), maintenance project
management services worldwide.

Project Configurations: 2* 20ft Container data center with 4


standard rack, adopt 25kw Precision In Row cooling for cooling
and Modular UPS power supply .

Project Summary : Containerized data center can be


considered a standardized, factory-built and pre-tested large-
scale modular data center product and solution. have the
advantage of lower space, power and cooling costs, and can be
deployed in any area where power is available. Complete data
center capacity expansion for enterprises in a short period of
time

40
3
Part
Projects Introduction
Coolnet Case

National Autonomous University of Mexico

Project Background:
National Autonomous University of Mexico, founded in 1551,
is Mexico and Latin America’ s oldest and largest
comprehensive university, one of the largest university in the
world, located in Mexico City, also one of the largest public
universities.

Project summary : According to the demand of National


autonomous university of Mexico, Coolnet provides
computer room total solution, includes several sets
Precision air conditioning and UPS, not only ensure the
standard working environment of the campus computer
room, Also ensure a good and steadily operation of the live
show.

41
3
Part
Projects Introduction
Coolnet Case

Sinus-Dochi LLC Data Centre Project in Mongolia

Project Background:
Sinus-Dochi LLC is a leading HVAC service company in
Mongolia, boasting a team of technical engineers who
specialize in the field of refrigeration. We COOLNET
collaborated with the client on their existing data center
project to develop a comprehensive cooling system
design solution for their facility.

Project Configuration: COOLNET provides high-quality


In-Row precision air conditioning solutions for existing
data centers, ensuring optimal performance and
efficiency.
Project Summary :The project is currently in the
preparatory stage, with later stages of progress soon to
follow. We Coolnet team has received high praise from
our Mongolian client for delivering exceptional product
quality and providing excellent communication services
throughout the project's development.

42
3
Part
Projects Introduction
Coolnet Case

100KW Precision Air Conditioning Project In Malaysia

Project Background:
Open DC Malaysia is a prominent cloud service network
technology company , specializing in server storage
services for its customers.
Project Configuration: 2 sets of 100KW air-cooled air
conditioners
Project Summary :The client was retrofitting an existing
data center and required two room-level air-cooled air
conditioners. However, due to the small and outdated
size of the data center, conventional precision air
conditioners could not be carried in properly.
Fortunately, COOLNET's precision air conditioners for
large server rooms are designed with modular
components, allowing for easy installation on-site and
tailored to the customer's requirements. This flexibility
and versatility are among the many strengths of
COOLNET's air conditioning solutions, enabling us to
meet the diverse needs of our customers.

43
3
Part
Projects Introduction
Coolnet Case

Georgian Government Precision Air Conditioning Project


Project Background:
GREE's agent in Georgia, operating in the HVAC industry, which
has played a significant role in the c o u n t r y ' s e c o n o mi c
development.

Project Configuration: 22pcs of 6.4kw precision cooling


system, 1pcs of 7.5kw precision cooling system, 4pcs of 12.5kw
precision cooling system, 1pcs of 17.5kw precision cooling system.

Project Summary :
The precision air conditioner requirement in this tender, issued by
the local government, is for a large-scale project and specifically
aimed at meeting the cooling needs of a data center.
During the tender process, the client conducted a comprehensive
evaluation of the supplier, including qualification, comprehensive
product performance, delivery time and after-sales service
capabilities. COOLNET established a professional team to
conduct extensive market research, comprehensive product
analysis, and online technical communication, resulting in their
selection as the supplier of precision air conditioners for the
project. Their commitment to delivering high-quality products and
exceptional customer service proved instrumental in securing this
partnership, showcasing COOLNET's expertise in the industry.

44
3
Part
Projects Introduction
Coolnet Case

MDC-Shanghai Yunman IDC

Project Background:
SUNGROW is a listed PV inverter company, with inverter
equipment selling well in more than 150 countries around the world
and is a leading enterprise in Anhui Province.

Project Summary :
• Approximately 2,000 sets of specially customized white server
cabinets
• 800 sets of in-row precision air conditioners,
• large modular UPS
• Integrated DCIM system.
• Each cold aisle module is equipped with a double pull-out
Precision Power Distribution Cabinet.

45
3
Part
Projects Introduction
Coolnet Case

China Unicom IDC in Changsha

Project Background:
Our company has successfully established a partnership as a UPS
supplier for Saudi Aramco. Our first shipment of 100 UPS units has
been exported, and we are proud to see that our innovative
strength has once again been recognized. Moving forward, we
remain committed to providing reliable UPS power solutions to
support Saudi Aramco's projects.

Project Summary :Core server room: one 26-cabinet double-row


micro-module system is configured, the size specification of the
cabinets used is 600mm x 1200mm x 2000mm (W x D x H), the
number of IT server cabinets is 20, four 25kw inter-column air
conditioners, one 175KVA modular UPS system, one precision
power distribution cabinet and one set of dynamic loop system.
In addition to the core server room, this project plant also supplies
10 too of 8KW and 12.5KW small precision air conditioners, two
60KVA industrial frequency UPS and two 30KVA industrial
frequency UPS, as well as supporting batteries.

46
3
Part
Projects Introduction
Coolnet Case

MDC-SUNGROW

Project Background:
This project is a 18-rack Cold Aisle Containment for Northwest
University of Political and Law.

Project Summary :
• Configuration: 1 set Dual-row MDC(18 racks)
• Rack: Size:600*1200*2000mm, 14 units IT racks
• Cooling: 2 sets 40KW In-row precision air conditioning
• Power: Row Modular UPS, 1 set
• Power Distribution Cabinet 1 set, DCIM 1 set

47
3
Part Coolnet Case

MDC-Northwest University of Political Science and Law

Project Background:
This is a IDC project for China Unicom-Changsha Branch

Project Summary :
• Configuration: 5 sets of 32-racks Double-row MDC
• Rack: Size: 600*1200*2000mm, IT racks: 110 units
• Cooling: 40 sets of 50KW in-row precision air conditioning
• Power; 2 sets of Modular UPS System
• Power Distribution Cabinets: 10 sets
• DCIM 1set

48
3
Part
Projects Introduction
Coolnet Case

CDC-University of Traditional Chinese Medicine

Project Background:
This is a Container Data Center for University of Traditional
Chinese Medicine。

Project Summary :
• Configuration: 2 sets 20 ft CDC(11 racks)
• Rack: Size:600*1200*2000mm
• Cooling: 2 sets of 40KW In-row PAC for each Container

49
3
Part
Projects Introduction
Coolnet Case

Micro Min DC- Jianyang Court

Project Background:
The Jianyang court information construction project is located on
the 3rd floor of the newly built office building. Total power
consumption exceeds 100KW of high thermal density cold aisles.
The purpose of the IDC is to promote the innovation of court
administrative management, improve the court decision-making
system, promote the reform of industry management methods, and
then improve the level and efficiency of business management.

Project Summary :
• Configuration: 2 sets 11-rack Cold Aisle Containment
• Rack: Size:600*1200*2000mm
• Cooling: 3 sets 40KW In-row precision air conditioning
• Power: 175 KVA Modular UPS, 1 set
• Power Distribution Cabinet 1 set, DCIM 1 set

50
Thanks!