SPECIFICATIONS
Type Infrared Imaging Thermometer
Unit of Measurement Celsius and Fahrenheit
Temperature Range -20~350℃ (-4~662°F)
Accuracy (Tamb = 20 to 26°C ) ± 2% of reading or
2°C (4°F) whichever is greater.
Emissivity 0.95 default – adjustable 0.1 to 1
Resolution 32 x 31 pixels
Display 2.8 in. LCD (colour display) and a 33x33
degree field of vision.
Sensitivity 0.1°C
Frame Rate 9 Hz
Battery Details 4 pc AA batteries providing 6 hrs.
continuous use battery life
(Batteries included)
Feature(s) USB compatible, focus free view.
Dimensions 3-3/4 x 2-7/8 x 9-3/16 in.
Contents 16 GB Micro SD Card (Included)
INTRODUCTION
Instantly measure temperatures from a distance without
contact. Ideal tool for measuring temperatures in hard to reach
or dangerous to access places. The thermal imager camera can
measure from -20~350°C (-4~662°F) and displays the thermal
image and temperature. Furthermore, thermal images can be
saved to a micro SD card. Software is included to transfer
images for image report generation from the saved images.
SAFETY
WARNING! Read and understand all instructions before using
this tool. The operator must follow basic precautions to reduce
the risk of personal injury and/or damage to the equipment.
Keep this manual for safety warnings, precautions, operating or
inspection and maintenance instructions.
WORK AREA
1. Operate in a safe work environment. Keep your work area
clean, well lit and free of distractions.
2. Keep anyone not wearing the appropriate safety
equipment away from the work area.
3. Store tools properly in a safe and dry location. Keep tools
out of the reach of children.
PERSONAL SAFETY
WARNING! Wear personal protective equipment approved by
the Canadian Standards Association (CSA) or American
National Standards Institute (ANSI).
PERSONAL PROTECTIVE EQUIPMENT
1. Always wear impact safety goggles that provide front and
side protection for the eyes. Eye protection equipment
should comply with CSA Z94.3-07 or ANSI Z87.1 standards
based on the type of work performed.
2. Wear the appropriate type of full-face shield in addition to
safety googles, as the work can create glare or
infrared/ultraviolet light.
PERSONAL PRECAUTIONS
Control the tool, personal movement and the work
environment to avoid personal injury or damage to the tool.
1. Do not operate any tool when tired or under the influence
of drugs, alcohol or medications.
Visit www.princessauto.com for more information 3
8616484 THERMAL IMAGER V1.1
UNPACKING
WARNING! Do not operate the tool if any part is missing.
Replace the missing part before operating. Failure to do so
could result in a malfunction and personal injury.
Remove the parts and accessories from the packaging and inspect
for damage. Make sure that all items in the contents are included.
Contents:
• Thermal Imager • Batteries
• Memory Card • Software CD
• USB Cable • Metal Case
IDENTIFICATION KEY
Fig. 1
A LCD G Micro SD
B Up Key H Mini USB
C Colour Palette Key I Infrared Lens
D Down Key J Trigger
E Unit Key K Battery Cover
F Mode Key
FUNCTIONS
Press the mode key (F) to scroll through the display functions,
then press the up key (B) or the down key (D) to change the
functions, then press the trigger (J) to confirm the selection.
E The default emissivity is 0.95. You can select a different
default emissivity: Blackbody (1.0), Matt (0.95), Semi-
matt (0.8), Semi-glossy (0.6) and Glossy (0.3).
Select Set Value to adjust the emissivity rating in 0.01
increments up to 1.0.
HAL When the reading is outside the High Alarm (HAL) or
LAL Low Alarm (LAL) limit, the reading shown at the top
right corner of the screen will constantly flash (HAL is
red and LAL is blue) with two short beep sounds. Select
Set HA temp or Set LA temp to adjust the limits or
select ON/OFF to turn on/off the alert.
Power The default setting is ‘Auto off 1 min’. You can select
off other default values: 5, 10, 20 minutes or ‘No auto off’.
Manually powering off the device by pressing the mode
key (F) for three seconds.
Backlight Selectable three levels of brightness.
Set time Set the date and time in:
MM/DD/YYYY (month/day/year); and
HH/MM/SS (hour/minute/second) formats.
Time Turn on Time stamp to save thermal images with a real-
stamp time stamp.
Turn off Time stamp to hide the date and time on
stored thermal images.
Erase file Select All picture! To clear all stored thermal images.
Select All movie! To clear all stored videos.
Save Select Picture to save thermal images in image mode
mode (BMP and Excel formats).
Select Movie to save thermal images in video mode.
Noise Turn on Filter to reduce noise in an image.
filter Turn off Filter to display real image noise.
OPERATION
1. Turn the device on by pressing the trigger (J).
NOTICE! Do not point the imager at high temperature sources
when turning the device on.
2. After turning the power on, simply
aim the thermal imager camera at the
measure target with lens (I) and get
the thermal image and temperature
immediately. Make sure the target
area is within the field of view.
There are three cursors on the
screen. The main cursor shows the
temperature of the object located in
the middle of the screen. The other
two moving cursors indicates the
highest and lowest temperatures in
Fig. 2
the thermal image (Fig. 2).
6 For technical questions call 1-800-665-8685
V1.1 THERMAL IMAGER 8616484
3. Press the trigger (J) to save the thermal image to the micro
SD card. Press the up key (B) or down key (D) to show the
saved images. Press mode key (F) again to return to the
measurement screen.
The default save mode is ‘Picture’. You can select ‘Picture’
or ‘Movie’ mode before saving. See the Functions section
to learn how to setup the ‘Save mode.’
4. There are four selectable colour palettes to view the thermal
images. Press the colour palette key (C) to select the colour
palette. Figure 3 shows the gradation. The darker colours are
on the left and
move to lighter
colours on the right. Fig. 3
Fig. 4
SOFTWARE
1. Insert the software disc into your PC.
2. Open the document ‘USB VCOM Software for Windows’ to
install the USB driver.
3. Connect the USB cable to the thermal imager and then
connect to your PC.
4. Click on the file ‘ArraySW.EXE’.
5. The next step is to initialize the interface. Depending on
your system, you have to choose the pursuant COM Port by
following these steps:
a. Connect the USB jack. If you want to connect the
device directly to the computer, you have to use the
USB cable.
b. Power up the device by connecting the USB power
cable.
c. Select ‘COM*’ in the Communication Port Setting.
d. Click the ‘Start’ button. If TIM03C is present, the GUI
will show data in the dialogue box.
e. Press the ‘TURN OFF’ button to stop working with the
thermal imaging software.
PROGRAM FEATURES
This is a short overview of all functions of the program:
Fig. 5
As you can see from the screenshot, some elements are
information-giving while others are for control. First we will
discuss the information-giving elements:
ID ITEM FUNCTION
A Set Interface: Determine your COM port. Protocol
COM specifications: Transfer rate 460800 baud,
bata bits, no parity, 1 stop bit, NONE.
B/C Start/Turn Off Starts and stops capturing data.
D Module Type Thermopile sensor array is 32x31.
E FPS Shows frames per second.
F Pixel Screen The pixel screen shows a calculated RGB-
Value for the temperature each thermophile
sees.
ID ITEM FUNCTION
G Set Framestack allows for integrating over
Framestack multiple pictures for better quality because
of noise reduction by accepting a lower
frame rate. The framestack can bet a size
between 1 and 300.
H Temperature This field shows a histogram. It represents
Distribution of the distribution of temperatures.
all Pixels
I Pixel This field shows the temperature of all
Temperature thermophiles.
False Colour The false colour scale shows the range of the
Scale chosen colour scheme and the minimum and
maximum values in the pixel screen.
Single Pixel Single pixel information shows several pieces
Information of information of a pixel selected at the pixel
screen by mouse or keyboard (use arrows).
J Set Colour There are eight different colour schemes
Scheme available.
K Interpolate Interpolation simulates a higher resolution,
from 32x31 to 128x127 pixels for example.
L Options Set temperatures in °C, °F, K.
Set mirror frame: X-Axis / Y-Axis / Both.
M Save Data The data stream can be saved in the file
Stream to File formats .bds / .txt / .avi. For analysis the text
(.bds / .txt / files are easier to handle.
.avi) First click ‘Save to…’ and enter name, file type
and destination where you want it to save to.
To begin data capturing, click ‘Rec’ in the Save
to File-Box. The button is highlighted red, as
long as data capturing proceeds. You can stop
recording by pressing ‘Stop’ in the Save to
File-Box. The red highlighting of the Rec-
Button disappears.
If you want to play the stored stream with
your program, press ‘Play’. A new window
appears. Press ‘Open stream…’ and open the
desired file. Now enter the Frame rate, press
enter and confirm with play.
ID ITEM FUNCTION
M Save Data It is also possible to reduce the size of the
Stream to File file by setting the figure in the ‘Every Frame’
(.bds / .txt / field to a different amount. When ‘Every
.avi) Frame’ is set to 6, for example, then only
each sixth frame is recorded. This value is
also used when a recorded data stream is
played.
Play SD card First save the SD card files to your computer,
files (.bin) press ‘Open stream…’ and open the desired
binary file (.bin) as described above.
N Set Command ‘K’: Continuously display temperature data of
thermal images on PC.
‘x’: Stop transferring thermal images.
‘T’: Transfer to the thermal imager camera
and display temperature data.
0 Save Picture Temperatures and Pixel:
and Temp. Saves Temperature values table to Excel
Data to File (TIM_TempV_*****.xls) Saves Pixels to BMP
(TIM_Temp_*****.bmp)
CLEANING
The sensor lens is the most delicate part of the thermal imager.
The lens should be kept clean at all times, care should be taken
when cleaning the lens using only a soft cloth or cotton swab
with water or medical alcohol. Allow the lens to fully dry before
using the thermal imager.
Do not submerge any part of the thermal imager.
STORAGE
The thermal imager should be stored at room temperature.
DISPOSAL
Recycle a tool damaged beyond repair at the appropriate
facility.
Im
IMAGEUR THERMIQUE
MANUEL D'UTILISATEUR
IMAGEUR THERMIQUE
SPÉCIFICATIONS
Type Thermomètre d'imagerie infrarouge
Unité de mesure Celsius et Fahrenheit
Plage de temperature -20~350 °C (-4~662 °F)
Précision (T amb. = 20 à 26 °C ± le plus élevé de
2 % de la lecture ou 2 °C (4 °F)
Émissivité 0,95 par défaut – réglable de 0,1 à 1
Résolution 32 x 31 pixels
Affichage 2,8 po ACL (affichage couleur) et un
champ de vision de 33 x 33
Sensibilité 0,1 ℃
Fréquence d’image 9 Hz
Détails des piles Piles AA d’une durée utile de 6 heures
d’usage continuelle (piles comprises),
4 pièces
Caractéristique(s) Compatible avec USB, aucune mise au
point nécessaire.
Dimensions 3 3/4 x 2 7/8 x 9 3/16 po
Contenu Carte Mémoire MicroSD 16 Go (comprise)
INTRODUCTION
Mesure instantanément les températures à distance sans
contact. L'outil idéal pour mesurer les températures dans les
endroits dont l'accès est difficile ou dangereux. La caméra de
l'imageur thermique peut mesurer de 20~350°C (-4~662°F) et
afficher l'image thermique et la température. De plus, les
images thermiques peuvent être sauvegardées sur une carte
SD micro. Le logiciel permettant de transférer les images afin
de produire des rapports des images à partir des images
sauvegardées est compris.
2 En cas de questions techniques, appelez le 1-800-665-8685
V1,1 IMAGEUR THERMIQUE 8616484
SÉCURITÉ
AVERTISSEMENT ! Veuillez lire et comprendre toutes les
instructions avant d'utiliser cet outil. L'utilisateur doit respecter
les précautions de base lorsqu'il utilise cet outil afin de réduire
le risque de blessure ou de dommage à l'équipement.
Conservez ce manuel qui contient les avertissements de
sécurité, les précautions, les instructions de fonctionnement ou
d'inspection et d'entretien.
AIRE DE TRAVAIL
1. Travaillez dans un environnement de travail sécuritaire.
Gardez votre aire de travail propre, bien éclairée et
exempte de toute distraction.
2. Assurez-vous que les personnes qui ne portent pas
l'équipement de sécurité approprié ne se trouvent pas à
proximité de l'aire de travail.
3. Rangez les outils correctement dans un lieu sécurisé et sec.
Gardez les outils hors de la portée des enfants.
SÉCURITÉ PERSONNELLE
AVERTISSEMENT ! Portez de l'équipement de protection
personnelle homologué par l'Association canadienne de
normalisation (CSA) ou l'American National Standards
Institute (ANSI).
ÉQUIPEMENT DE PROTECTION PERSONNELLE
1. Portez toujours des lunettes antiprojections qui offrent une
protection frontale et latérale pour les yeux. L'équipement de
protection des yeux devrait être conforme à la norme CSA
Z94.3-07 ou ANSI Z87.1 fonction du type de travail effectué.
2. Portez un écran facial panoramique de type approprié avec
les lunettes de sécurité, puisque cette tâche peut
provoquer un éblouissement ou une lumière infrarouge/
ultraviolette.
Visitez www.princessauto.com pour plus d'informations 3
8616484 IMAGEUR THERMIQUE V1,1
PRÉCAUTIONS PERSONNELLES
Gardez le contrôle de l'outil, de vos mouvements et de
l'environnement de travail pour éviter les blessures ou le
bris de l'outil.
1. N'utilisez pas l'outil si vous êtes fatigué ou sous l'effet de
drogues, d'alcool ou de médicaments.
2. N'utilisez pas l'outil si vous devez étirer les bras pour vous
en servir. Une stabilité et un équilibre appropriés sont
nécessaires afin d'avoir un meilleur contrôle en cas de
situations inattendues.
DÉBALLAGE
AVERTISSEMENT ! Ne faites pas fonctionner l'outil si des
pièces sont manquantes. Remplacez les pièces manquantes
avant l'utilisation. Le non-respect de cet avertissement peut
entraîner une défectuosité et des blessures graves.
TOUCHE D'IDENTIFICATION
Fig. 1
UTILISATION
1. Activez l'appareil en appuyant sur le poussoir de
déclenchement (J).
AVIS ! Ne pointez pas l'imageur vers des sources à
température élevée au moment d'activer l'appareil.
2. Après avoir activé l'appareil, pointez
simplement la caméra de l'imageur
thermique vers la cible de mesure avec
la lentille (I) et captez immédiatement
l'image thermique et la température.
Assurez-vous que la cible se trouve
dans le champ de vision.
L'écran comporte trois curseurs. Le
curseur principal indique la température
de l’objet situé au milieu de l’écran. Les Fig. 2
deux autres curseurs mobiles indiquent
la température la plus élevée et la plus basse dans l'image
thermique (fig. 2).
3. Appuyez sur le poussoir de déclenchement (J) pour
sauvegarder l'image thermique sur la carte SD micro.
Appuyez sur la touche Haut (B) ou sur la touche Bas (D)
pour afficher les images sauvegardées. Appuyez de
nouveau sur la touche de mode (F) pour revenir à l'écran
de mesure.
Fig. 4
Lorsque l'icône de pile faible apparaît, la pile devrait être
remplacée immédiatement par une pile AA de 1,5 V.
IMPORTANT ! Il est important de fermer l'instrument avant de
remplacer la pile. Autrement, l'appareil pourrait être
défectueux.
LOGICIEL
1. Insérez le disque du logiciel dans votre PC.
2. Ouvrez le document intitulé « USB VCOM Software for
Windows » pour installer le pilote USB.
3. Branchez le câble USB à l'imageur thermique et ensuite à
votre PC.
4. Cliquez sur le fichier « ArraySW.EXE ».
5. L'étape suivante consiste à initialiser l'interface. Tout
dépendant de votre système, vous devez choisir le port
COM correspondant en effectuant ces étapes:
a. Branchez la prise USB. Si vous désirez brancher l'appareil
directement à l'ordinateur, vous devez utiliser le câble USB.
b. Activez l'appareil en branchant le câble d'alimentation USB.
c. Sélectionnez « COM* » dans Communication Port Setting
(réglage du port de communication).
d. Cliquez sur le bouton « Start » (activer). Si TIM03C
apparaît, l'IUG affichera les données dans la boîte
de dialogue.
e. Appuyez sur le bouton « TURN OFF » (désactiver) pour
cesser d'utiliser le logiciel d'imagerie thermique.
CARACTÉRISTIQUES DU PROGRAMME
Voici un bref survol de toutes les fonctions du programme :
Fig. 5
Comme vous pouvez le constater sur la capture d'écran,
certains éléments ont pour but de vous informer, alors que
d'autres sont des commandes. En premier lieu, nous
aborderons les éléments qui ont pour but de vous informer :
ID ARTICLE FONCTIONNEMENT
A Réglage Déterminez votre port COM. Spécifications
d'interface : COM du protocole : Débit de transfert de 460
800 bauds, bits de données, aucune parité,
1 bit d'arrêt, AUCUN.
B/C Démarrer/arrêter Démarre et arrête la saisie des données.
D Type de module Le réseau de capteurs thermophile est de
32 x 31.
E Images/seconde Présente le nombre d'images par seconde.
F Écran à pixels L'écran à pixels présente la valeur RVB
calculée en fonction de la température que
voit chaque thermophile.
SOIN ET ENTRETIEN
1. Entretenez l'outil avec soin. Un outil en bon état sera
efficace, plus facile à contrôler et préviendra les problèmes
de fonctionnement.
2. Inspectez les composants de l'outil régulièrement. Réparez
ou remplacez les composants endommagés ou usés.
Employez seulement des pièce autorisées.
3. Utilisez seulement des accessoires conçus pour être utilisés
avec cet outil.
4. Gardez les poignées de l'outil propres, sèches et exemptes
d'huile ou de graisse en tout temps.
5. Veillez à ce que l'étiquette et la plaque signalétique
demeurent intactes sur l'outil. Elles comportent des
renseignements importants. Si elles sont illisibles ou
manquantes, communiquez avec Princess Auto Ltd. pour
les remplacer.
AVERTISSEMENT ! Seul un personnel d'entretien qualifié doit
effectuer la réparation de l'outil/l'appareil. Un outil/appareil
mal réparé peut présenter un risque pour l'utilisateur et/ou
pour les autres.
NETTOYAGE
La lentille du capteur est la pièce la plus fragile de l'imageur
thermique. La lentille doit être propre en tout temps. Procédez
avec soin au moment de nettoyer la lentille au moyen d'un
chiffon doux ou d'un coton-tige avec de l'eau ou de l'alcool de
qualité médicale. Laissez la lentille sécher complètement avant
d'utiliser l'imageur thermique.
Ne plongez aucune partie de l'imageur thermique dans un liquide.
ENTREPOSAGE
The thermal imager should be stored at room temperature.
MISE AU REBUT
Recyclez votre outil endommagé dans une installation prévue à
cet effet s'il est impossible de le réparer.