You are on page 1of 1

Bridge No.

A B

Typ. connection Exp. jt. connection


**12'-0" Max. (typ.)

A= 1'-2•" thru 1'-5•"


TS 1"x 1"x „" ƒ" x 1‚" slotted holes in 5Œ"
Snap lock flat caps
B= 5'-0•" thru 5'-3•" 6Œ"

3"
@ top of each Continuous through angles for †" dia. A325 bolts 1‚"
TS 4"x 4"x ‚" 1'-0"
vertical bar. holes in channel. 3" ƒ" x 2†" slotted holes in
(typ.) TS 1"x 1"x „" 1"
Top of Cap is held in place
C C angles for †" dia. A325 bolts

9"
channel with two self tapping
L 5"x 3"x •"
screws (180° apart).
C4x 5.4 (2•" long)
03-2016

road)
C4x 5.4 1Ž "1ˆ" 2†" Typ.

6" Œ" Typ.

l

n.for Rai
es
L 3"x 2" x •"

Vari
ƒ" dia. hole in channels for †" dia. A307 bolt.

n.
(2•" long)

-0" mi
det3243

Bolts are to be secured using double hex nuts and

B
washers, allowing screening horizontal movement.

-0" mi
TYPICAL EXPANSION JOINT CONNECTION DETAILS

8'
Extg. 4"

10'
1‚"
Top of rail 3" ƒ" x 1‚" slotted holes in

(
channel TS 1"x 1"x „" •"
angles for †" dia. A325 bolts (typ.)
C4x 5.4

Top of conc.

A
parapet wall
Note:
C4x 5.4 Typ.
‚" x 3" plate Anchorage configuration varies „
depending on structure details. L 3"x 2" x •" Typ.
See Detail "B" ‚
Shim as needed See detail drawings. (2•" long) typ.
3" x 3" x ‚"
Welded wire mesh to make level and plumb TYPICAL CONNECTION DETAILS

SECTION "C-C"

-0"
No Scale

1'
-0"
SECTION

1'
ELEVATION - TYPICAL SCREENING PANEL
Scale : ƒ"= 1'-0"

Note: Scale : ƒ"= 1'-0"


Wire Mesh Attachment Notes:

-0"
Slope of screening panels may vary. Provide ‰" long flare bevel groove welds @ 2'-0" each

1'
See plan sheets for additional details at specific structures. way to 1" square tubes.
Screening panels shall match the slope of the bridge (|1% slope) Provide a minimum of 2 welds in mesh below bottom C4 x 5.4.
while maintaining vertical alignment of wire mesh and 1" square tubing. Wire mesh to be parallel with vertical bars.
Fabricate parallelogram panels in 0, 2, 4, 6, 8% step increments. Place and weld wire mesh on the outside face of the
See Detail "A"
See DET3244 for Fence Support Details. protective screening.
Maximum ‚" gap between wire mesh and edge members.

C3 x 5 Outside Diameter= C
(C= B-(1'-10•") or C= (B+1•")-2'
3" x 3" x ‚"
Welded wire mesh

B B
1•"
3" x 3" x ‚" BTC-P10-GF
A A Welded wire mesh 5@2'-0" *
3"

4'-0" *6'-0" **12'-0" Max. (typ.)


C3 x 5
TS 1"x 1"x „"

Seal (typ. each end, each side)
„ BTC-P10
Drill ƒ" Note:
SECTION "A-A" ‚" x 3" plate
or
drain hole BTC-P10-GF * When conflict occurs here, place end post spacing
No Scale SCREENING PANEL STEP DETAIL
•" at 5'-0", and 5'-0" (for second choice)
No Scale
or 6'-0", and 6'-0" (for third choice).

‚ TS 1"x 1"x „"
2" ** When conflict occurs here, place post spacing
‚ 1" \ at 10'-0" then resume 12'-0" max. spacings.
DET3243

C3 x 5 DETAIL "A" OREGON DEPARTMENT OF TRANSPORTATION


The selection and use of this detail,
TECHNICAL SERVICES
Scale : ƒ"= 1'-0" DETAIL "B" while designed in accordance with DETAILS
WIRE MESH ATTACHMENT
TS 4"x 4"x ‚" generally accepted engineering
Scale : 1•"= 1'-0"
principles and practices, is the sole DETAIL NO.
SECTION "B-B" ORNAMENTAL
responsibility of the user and should
No Scale not be used without consulting a
PROTECTIVE SCREENING
DET3243
Registered Professional Engineer. MISC. FENCE DETAILS

1:16 - det3243