You are on page 1of 82

Self-Service

Systems
CERTO Floor-Standing Model

Installation Guide
Questions and suggestions

Do you have ...

... any questions or suggestions regarding ... any technical questions or problems?
this manual?

Please contact the following address giving Please contact the Wincor Nixdorf
the order number of this manual in your Customer Care Center:
message:
E-mail: WNCCC.contact@wincor-nixdorf.com
Address:
Wincor Nixdorf International GmbH
Handbuchredaktion BD P34
33094 Paderborn
Germany

Fax: +49 (0) 52 51 693-62 09

E-mail: manuals.hardware@wincor-nixdorf.com

CERTO Floor-Standing Model - Installation Guide 01750051417 C


CERTO Floor-Standing Model

Installation Guide

Edition January 2003


Copyright © Information and trademarks

© Wincor Nixdorf International GmbH 2003

All rights, including rights of translation and


rights of reproduction by reprinting, copying
or similar methods, even of parts, are
reserved.
Any violations give rise to a claim for
damages.

All rights, including rights created by patent


grants or registration of a utility model or
design, are reserved. Delivery subject to
availability; right of technical modifications
reserved.

All names of hardware and software


products mentioned in this manual are
trade names and/or trademarks of their
respective manufacturers.

This manual was


produced using paper
treated with chlorine-free
bleach.

CERTO Floor-Standing Model - Installation Guide 01750051417 C


Contents

Introduction ....................................................................................................................... 1
Symbols used in this guide.................................................................................................. 1
Important safety precautions ............................................................................................... 2
Installation notes ............................................................................................................ 2
General safety precautions ............................................................................................ 2
Abbreviations....................................................................................................................... 4

Planning the Installation................................................................................................... 5


Device dimensions .............................................................................................................. 5
Device with printer .......................................................................................................... 6
Device with base plate .............................................................................................. 6
Device without base plate ......................................................................................... 7
Device without printer ..................................................................................................... 9
Device with base plate .............................................................................................. 9
Device without base plate ....................................................................................... 10
Installation options for the device versions........................................................................ 12
Required operation and maintenance space..................................................................... 13
Device with base plate ................................................................................................. 13
Device without base plate ............................................................................................ 14
Installation site requirements............................................................................................. 15
Drilling diagram.................................................................................................................. 16
Power and data cables ...................................................................................................... 17
General information...................................................................................................... 17
Power supply................................................................................................................ 19
Transport path requirements ............................................................................................. 19

Installation ....................................................................................................................... 23
Removing the packaging................................................................................................... 23
Removing the shipping pallet ............................................................................................ 24
General information...................................................................................................... 24
Removing the shipping pallet ....................................................................................... 25
Device without printer.............................................................................................. 25
Device with printer................................................................................................... 26
Mounting sets .................................................................................................................... 27
Mounting set for floor mounting.................................................................................... 27
Base plate set............................................................................................................... 27
Overview of installation types ............................................................................................ 28
01750051417 C CERTO Floor-Standing Model - Installation Guide
Contents

Installing and connecting the device with base plate......................................................... 29


Preparing the base plate .............................................................................................. 29
Device without printer ................................................................................................... 30
Device with printer ........................................................................................................ 31
Installing and connecting the device without base plate.................................................... 33
Start-up.............................................................................................................................. 38

Appendix .......................................................................................................................... 39
Opening / closing the device ............................................................................................. 39
Device without printer ................................................................................................... 39
Removing / installing the monitor cover .................................................................. 39
Removing / installing the rear cover ........................................................................ 41
Device with printer ........................................................................................................ 42
Pulling out the equipment carriage.......................................................................... 42
Pushing in the equipment carriage.......................................................................... 43
Removing the front panel ........................................................................................ 44
Installing the front panel .......................................................................................... 44
Removing / installing the rear cover ........................................................................ 45
Check list for installation preparations for self-service systems ........................................ 46
General information...................................................................................................... 47
Preparations ................................................................................................................. 48
Construction work.................................................................................................... 48
Power and data cables............................................................................................ 48
Organizational preparations .................................................................................... 48
Delivery and installation........................................................................................... 49
Flooring materials on the path of transport ............................................................. 49
Notes concerning installation preparation .................................................................... 50
Technical data ................................................................................................................... 52
General installation conditions...................................................................................... 52
Electrical characteristics of the supply network....................................................... 52
Device conditions .................................................................................................... 52
Installation conditions .............................................................................................. 53
Environmental conditions ........................................................................................ 54
Compliance with standards and certifications .............................................................. 55
Standards met ......................................................................................................... 55
Conformity ............................................................................................................... 55
Notes concerning radio interference suppression and electrical safety .................. 55
FCC rules and Canadian Standard ICES - 003....................................................... 56
Certification for data transmission........................................................................... 56
Environmental protection................................................................................................... 57
Environmentally friendly product design and development .......................................... 57
Saving energy............................................................................................................... 57
Disposing of used consumables................................................................................... 57
Labels on plastic case parts ......................................................................................... 57
Returning, recycling and disposing of used units and consumables............................ 57
Further information ....................................................................................................... 57

CERTO Floor-Standing Model - Installation Guide 01750051417 C


Contents

Scale drawings (scale 1:20) .............................................................................................. 58


Device overview ........................................................................................................... 58
CERTO Floor-Standing Model with base plate ....................................................... 58
CERTO Floor-Standing Model without base plate .................................................. 67
Space required for operation and maintenance ........................................................... 70
CERTO Floor-Standing Model with base plate ....................................................... 70
CERTO Floor-Standing Model without base plate .................................................. 71
Transport ...................................................................................................................... 72

01750051417 C CERTO Floor-Standing Model - Installation Guide


Contents

CERTO Floor-Standing Model - Installation Guide 01750051417 C


Introduction
This installation guide provides you with all the information you need to install the
information terminal CERTO Floor-Standing Model.

The information terminal CERTO Floor-Standing Model is available with the following
components:

− Base plate
− Swipe card reader
− Insertion reader
− Printer
− Keyboard
− Barcode scanner

Symbols used in this guide


− Text following this mark represents an item in a list.

" " Text in quotation marks contains references to other chapters or sections in this
document.

• Paragraphs following this symbol are actions to be performed in the specified order.

Text following this symbol have to be given special attention in order to avoid
damage or injury.

This symbol identifies paragraphs which contain general notes to facilitate use of
the device and help avoid operating errors.

01750051417 C CERTO Floor-Standing Model - Installation Guide 1


Important safety precautions Introduction

Important safety precautions


Please read the following notes carefully before doing any work on the device.

Installation notes
− When installing the device and/or doing any work on it, make sure that it is
disconnected from power.

− Remove those parts inside the unit which secure its components during transportation,
if necessary for the installation (see enclosed information sheet).

General safety precautions


This device complies with the relevant safety regulations for information processing
equipment.

− When moving the device from a cold to a warm environment, do not operate it for at
least two hours to prevent possible damage caused by condensation.

− Only use the original packaging material to transport the device.

− Note the warning and information labels on the device.

− The device is equipped with a safety-tested power cable, which must be connected
only to a grounded outlet.

− Always hold the plug when removing the power cable. Never pull the cable itself.

− Install cables in such a way that they will not be stepped on or tripped over or damaged
or crushed in any way.

− Have damaged power cables replaced immediately.

− Make sure that there is always free access to the sockets used or to the electrical
circuit-breakers of the house installation.

− In case of an emergency (e.g. damaged cabinets, controls or power cables, liquids or


foreign objects in the device) take the following steps:

2 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Introduction Important safety precautions

Deactivate the device immediately by:

Switching off the automatic circuit-breaker or removing the fuse inset from the fuse
holder in the distribution box of the building installation or by disconnecting the plug
connector of the power supply cable from the grounded socket in the building
installation or by switching off the ON/OFF switch on the power distributor

Inform the customer service responsible for you.

− During a thunderstorm, data transmission lines must not be connected or


disconnected.

− Only use accessories and extension components that have been approved by us.
Nonobservance can result in damage to the device or violations of regulations
concerning safety, radio interference and ergonomical requirements.

− Note that there are only safety extra-low voltage circuits (SELV circuits) if you want to
feed voltage from an external source into prepared cables to install additional
electronics (e.g. connection for an intruder alarm system).

− To clean the device only use cleaning agents approved by Wincor Nixdorf International
GmbH (see chapter "Appendix", section "Approved cleaning materials" in the operating
manual).

Repairs

Repair work may only be carried out by authorized personnel.

Unauthorized opening of the device or repair work carried out improperly could
result in considerable danger to the user.

In case of noncompliance, Wincor Nixdorf International GmbH excludes all


liability.

01750051417 C CERTO Floor-Standing Model - Installation Guide 3


Abbreviations Introduction

Lithium batteries

There is danger of fire or explosion if the batteries are handled improperly. It is


therefore important to note the following points:

− Avoid short circuits.


− Never recharge the battery.
− Avoid temperatures above 100 °C.
− Do not try to open the battery by force.
− Do not allow the battery to come into contact with water or fire.

Replace the battery only with the same or an equivalent type recommended by
Wincor Nixdorf International GmbH (see chapter "Appendix", section
"Consumables" in the operating manual). Dispose of used batteries in compliance
with national regulations (observe the manufacturer's specifications, if necessary).

Abbreviations
CE Communauté Européenne
(European Community) Declaration of Conformity
DT Data transmission
EC European Community
EEC European Economic Community
EMC Electromagnetic compatibility
EN European standard
FCC Federal Communications Commission
ID Identification
IEC International Electrotechnical Commission
IP International protection
ISO International Organization for Standardization
L N PE Line Neutral Protective Earth
SELV Safety extra-low voltage
TN network Power supply network in acc. with EN 60950

4 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Planning the Installation
This chapter provides you with all the information you need to prepare the installation.

Device dimensions
All dimensions are specified in millimeters (inches). The views of the device are
not drawn to scale.

A front view, side view, top view, rear view and a view of the maintenance space
on a scale of 1:20 can be found in the appendix.

01750051417 C CERTO Floor-Standing Model - Installation Guide 5


Device dimensions Planning the Installation

Device with printer

Device with base plate

472 (18.58")

1542 (60.71")
1552 (61.1")
10 (0.39")

1 2

720 (28.35") 269


(10.59")
720 (28.35")
720 (28.35"')

720 (28.35")

1 Foot plate 2 Base plate

6 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Planning the Installation Device dimensions

Device without base plate

Device with swipe card reader

526 (20.71")
472 (18.58")

1537 (60.51")
1542 (60.71")
5 (0.2")

1 Foot plate

01750051417 C CERTO Floor-Standing Model - Installation Guide 7


Device dimensions Planning the Installation

Device with insertion reader

540 (21.26")
472 (18.58")

1537 (60.51")
1542 (60.71")
5 (0.2")

1 Foot plate

8 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Planning the Installation Device dimensions

Device without printer

Device with base plate

472 (18.58")

1542 (60.71")
1552 (61.1")
10 (0.39")

1 2

720 (28.35") 97 (3.82")


720 (28.35")
720 (28.35")

720 (28.35")

1 Foot plate 2 Base plate

01750051417 C CERTO Floor-Standing Model - Installation Guide 9


Device dimensions Planning the Installation

Device without base plate

Device with swipe card reader

526 (20.71")
472 (18.58")

1537 (60.51")
1542 (60.71")
5 (0.2")

97
1 (3.82")

1 Foot plate

10 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Planning the Installation Device dimensions

Device with insertion reader

540 (21.26")
472 (18.58")

1537 (60.51")
1542 (60.71")
5

97
1 (3.82")

1 Foot plate

01750051417 C CERTO Floor-Standing Model - Installation Guide 11


Installation options for the device versions Planning the Installation

Installation options for the device versions


The information terminal CERTO Floor-Standing Model is installed with or without a base
plate.

If the device is installed without a base plate, it must be secured to the floor with
its foot plate using screws.

Device with base plate Device without base plate

1542 (60.71")
1552 (61.1")

If the system is installed at a construction site, use the air cushion foil the system
is delivered in. You may use the bubble pack the system is wrapped in for this
purpose.

12 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Planning the Installation Required operation and maintenance space

Required operation and maintenance space

Device with base plate

1400 (55.12")
900 (35.43") 500 (19.69")

1400 (55.12") 1400 (55.12")

500 (19.69") 900 (35.43")


1400 (55.12")

Required maintenance space

Space required for maintenance may be reserved either to the left or to the right of the
device.

01750051417 C CERTO Floor-Standing Model - Installation Guide 13


Required operation and maintenance space Planning the Installation

Device without base plate

(9.45")
240
1400 (55.12")
900 (35.43") 500 (19.69")

1400 (55.12")

(9.45")
240

1400 (55.12")

500 (19.69") 900 (35.43")

1400 (55.12")

Required maintenance space

Space required for maintenance may be reserved either to the left or to the right of the
device.

14 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Planning the Installation Installation site requirements

Installation site requirements


The installation area must be flat and on one level with the surrounding floor. Any
differences in floor height in the installation area must be leveled out with rustproof shims,
for example. This is not part of the installation procedure, but must be done by a
contractor.

When choosing the installation site, make sure that

− bright ceiling light, light reflections and direct sunlight shining on the screen are
avoided,
− the requirements concerning ambient conditions can also be met in lobbies (see
chapter "Appendix", section "Technical data"),
− existing underfloor heating, energy and/or communication cables, etc., are not
damaged when drilling the mounting holes.

If necessary, appropriate arrangements must be made.

01750051417 C CERTO Floor-Standing Model - Installation Guide 15


Drilling diagram Planning the Installation

Drilling diagram

472 (18.58")

404.5 (15.93")
236 (9.29")

67.5 (2.66")
19.5 (7.78")

25 (0.98")
241 (9.49")

Drilling depth: 44 mm (1.73")


Drilling diameter: 12 mm (0.47")

16 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Planning the Installation Power and data cables

Power and data cables

General information
Cable routing through the floor is only possible for a device which is mounted
without a base plate.
Cable routing above the floor is possible for devices with or without a base plate.

When the cables enter the device from below, make sure that the cables cannot
be sheared off when the system is moved.

To connect the device, power and data cables are required. The power cable that is
included in the delivery has a standard length of 2 m (6.56 ft). Other ready-to-use lengths
of power and data cables can be ordered if needed via the hardware configurator or must
be provided by the customer. For the position of the cable feed opening please refer to
the appropriate illustration in this guide. The cable exit points in the floor must be kept
clear to ensure that the cables are not bent or damaged.

Free-standing devices are best connected through the cable exit opening in the floor to a
floor connection unit of sufficient size which has to be provided by the customer. The
connection unit must have a screwable top and has to be built into the floor flush with the
screed (safety and prevention of accidents). Make sure it is built in outside the device's
footprint.

Plan a big enough cable duct from the cable feed opening to the floor connection unit, so
that ready-made cables can be installed. The exit point of the cable duct should be right
under the cable feed opening of the device.

01750051417 C CERTO Floor-Standing Model - Installation Guide 17


Power and data cables Planning the Installation

Cable routing through the floor Cable routing above the floor

18 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Planning the Installation Transport path requirements

Power supply
The device must only be connected to a TN system. In addition to the power supply for
the device grounding outlets must be provided by the customer for supplementary
equipment such as a modem.

L N PE

1 Fuse or automatic circuit-breaker 3 Modem connection


2 CERTO Floor-Standing Model 4 Connection of miscellaneous equipment

Transport path requirements


The device is equipped with a shipping pallet and can be transported with a pallet lift
truck. The forks of the truck must be pushed as far as possible underneath the device
from the front or the rear.

Observe the ambient condition requirements for transportation and storage (see chapter
"Appendix", section "Technical data").

Due to the shipping pallet some dimensions are different (see illustration below).

01750051417 C CERTO Floor-Standing Model - Installation Guide 19


Transport path requirements Planning the Installation
1652 (65.04")

1652 (65.04")
110 (4.33")
850 (33.46") 1 800 (31.5")

1 Shipping pallet

20 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Planning the Installation Transport path requirements

Check beforehand if there is enough space to move the device through doors
and hallways.

The following illustration (scale 1:20) should help you determine if the space is
sufficient. It shows the device on a standard lift truck.
With the help of the grid (100 mm x 100 mm (3.94" x 3.94")) you can draw the
actual dimensions of the door and the hallway to find out if there is enough space
for transportation. Refer to the next page for an example.

In the appendix there is a drawing of the device with a lift truck on a scale of 1:20
which may serve as a template.

520 (20.47")

1350 (53.15")

01750051417 C CERTO Floor-Standing Model - Installation Guide 21


Transport path requirements Planning the Installation

Example with minimum transport path measurements

810 (31.89")
1900 (74.8")

520 (20.47")
1350 (53.15")

22 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Installation
This chapter describes the individual steps to be taken to install the device.

All dimensions are specified in millimeters (inches). The diagrams are not drawn
to scale.

Contact the person in charge of planning the installation to verify that all
preparations have been performed completely and professionally and that none of
the required power and data cables are missing.

Removing the packaging


• Remove the packing material of the information terminal CERTO Floor-Standing
Model and the base plate set, if necessary.

• Dispose of the packaging which is no longer needed according to the regulations of


your country.

01750051417 C CERTO Floor-Standing Model - Installation Guide 23


Removing the shipping pallet Installation

Removing the shipping pallet

General information
For transportation the device is equipped with a shipping pallet which must be removed
prior to the installation.

To move the device only push against the device's body as shown in the
illustration below.

24 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Installation Removing the shipping pallet

Removing the shipping pallet


Depending on your device version, remove the shipping pallet as described below.

Device without printer

• Remove the rear cover (see chapter "Appendix", section "Opening / closing the
device").

Remove the three screws and lift the device


carefully off the shipping pallet.

Please return the shipping pallet which is no longer needed to Wincor Nixdorf
International GmbH. Please contact your vendor, if necessary.

01750051417 C CERTO Floor-Standing Model - Installation Guide 25


Removing the shipping pallet Installation

Device with printer

• Pull the equipment carriage out and remove the front panel (see chapter "Appendix",
section "Opening / closing the device").

• Remove the rear cover (see chapter "Appendix", section "Opening / closing the
device").

Remove the two screws in front.

Remove the two screws in the back.

• Push the equipment carriage in and lock it (see chapter "Appendix", section "Opening /
closing the device").

• Lift the device carefully off the shipping pallet.

Please return the shipping pallet which is no longer needed to Wincor Nixdorf
International GmbH. Please contact your vendor, if necessary.

26 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Installation Mounting sets

Mounting sets

Mounting set for floor mounting


The mounting set 01750053833 for securing the device to the floor is supplied
with the CERTO Floor-Standing Model. .

Item Quantity required


– Hammer-in anchor M10 3
– Flat-head screw EN ISO 7046-1 M10 x 30 3

Base plate set


The base plate set's order number is 01750056891.

Item Quantity required


– Base plate 720 x 720 mm (28.35" x 28.35") 1
– Hexagon screw M10 x 20 2
– Hexagon screw M10 x 16 1
– Buffer pad PUR / SW SJ-5780 20; 5 4

01750051417 C CERTO Floor-Standing Model - Installation Guide 27


Overview of installation types Installation

Overview of installation types


Installation options
Device with base plate (see p. 29)
Device without base plate (see p. 33)

28 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Installation Installing and connecting the device with base plate

Installing and connecting the device with base plate


Observe the necessary maintenance space when deciding on a location (see
chapter "Planning the Installation", section "Space required for operation and
maintenance").

Preparing the base plate

• Apply the four self-adhesive buffer pads to the underside of the base plate in the four
corners (see section "Mounting sets").

Move the base plate to its final position and


2
align it.

1 - Customer panel side


2 - Device rear side

• Move the device to its final location and align it. Ensure that no cables are damaged in
the process.

01750051417 C CERTO Floor-Standing Model - Installation Guide 29


Installing and connecting the device with base plate Installation

Device without printer


Secure the foot plate to the base plate with two
screws M10x20 (1) and one screw M10x16 (2)
(for material see section "Mounting sets").
1

• Install the power and data cables (see also chapter "Planning the Installation", section
"Power and data cables").

The power and data cables are taken out of the


device through the openings (1) and (2) located
on the right and on the left in the rear cover.

2
1

• Secure the rear cover (see chapter "Appendix", section "Opening / closing the
device").

Make sure that the cables leave the device through the openings in the rear cover
and that they are not crushed.

30 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Installation Installing and connecting the device with base plate

Device with printer

• Pull out the equipment carriage (see chapter "Appendix", section "Opening / closing
the device").

Secure the foot plate to the base plate at the


device front using two M10x20 screws (for
material see section "Mounting sets").

Secure the foot plate to the base plate in the


rear using a M10x16 screw (for material see
section "Mounting sets").

• Install the power and data cables (see also chapter "Planning the Installation", section
"Power and data cables").

01750051417 C CERTO Floor-Standing Model - Installation Guide 31


Installing and connecting the device with base plate Installation

The power and data cables are taken out of the


device towards the back above the base plate
through the openings located on the right and
on the left in the rear cover.

• Secure the rear cover (see chapter "Appendix", section "Opening / closing the
device").

Make sure that the cables leave the device through the openings in the back
panel and that they are not crushed.
• Reinstall the front panel, push the equipment carriage in and lock it (see chapter
"Appendix", "Opening / closing the device").

32 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Installation Installing and connecting the device without base plate

Installing and connecting the device without base plate


The CERTO Floor-Standing Model without base plate must be secured to the floor. The
installation procedure for devices with printer and without printer is practically the same.
Differences are pointed out in the separate sections.

The power and data cables are taken out of the device either through the bottom or above
the foot plate towards the rear through the openings in the rear cover.

Observe the necessary maintenance space when deciding on a location (see


chapter "Planning the Installation", section "Space required for operation and
maintenance").

• Place the device in its correct position and mark the bore holes. Ensure that no cables
are damaged in the process.

• Remove the device and drill the required holes (see illustration below).

The drilling depth must be at least 44 mm (1.73") and the hole diameter
12 mm (0.47").

01750051417 C CERTO Floor-Standing Model - Installation Guide 33


Installing and connecting the device without base plate Installation

Mounting structure

44 (1.73")
2 2 3 2
4

1 CERTO Floor-Standing Model 3 Foot plate


2 Mounting set for floor mounting 4 Top surface of finished floor

• Clean the drill holes as specified in the instructions delivered with the mounting set.

• Secure the hammer-in anchors (see section "Mounting sets") in the floor.

Push the hammer-in anchors in the prepared holes. Before spreading the
anchor make sure that the anchors are pushed in to touch the bottom of the
holes.
Note the required drilling depth.
To fix the anchor, hammer in the expanding cone in the anchor using a punch
or a screwdriver.

• Align the device. Ensure that no cables are damaged in the process.

• Only for device with printer: Pull the equipment carriage out (see chapter
"Appendix", section "Opening / closing the device").

34 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Installation Installing and connecting the device without base plate

Device without printer

Secure the foot plate to the floor with three


screws (for material see section "Mounting
sets").

Device with printer

Secure the foot plate to the floor using two flat-


head screws at the front of the device ...

... and one flat-head screw at the rear (for


material see section "Mounting sets").

01750051417 C CERTO Floor-Standing Model - Installation Guide 35


Installing and connecting the device without base plate Installation

• Install the power and data cables (see also chapter "Planning the Installation", section
"Power and data cables").

Device without printer

The power and data cables are taken out of the


device either above the foot plate through the
openings (1) and (2) located on the right and on
the left in the rear cover ...

2
1

... or through the bottom.

36 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Installation Installing and connecting the device without base plate

Device with printer

The power and data cables are taken out of the


device either above the foot plate through the
openings (1) and (2) located on the right and on
the left in the rear cover ...

... or through the opening in the foot plate below


the power supply unit.

If necessary undo the fastening screws of


the power supply unit and lift it a little to
feed the cables through the hole.

01750051417 C CERTO Floor-Standing Model - Installation Guide 37


Start-up Installation

• Secure the rear cover (see chapter "Appendix", section "Opening / closing the
device").

Make sure that the cables leave the device through the openings in the back
panel and that they are not crushed.

• Only for device with printer: Reinstall the front panel, push the equipment carriage
back in and lock it (see chapter "Appendix", section "Opening / closing the device").

Start-up
The service technician will connect the power and data cables.

38 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix

Opening / closing the device


To open and close the device doors (monitor
cover, rear cover, equipment carriage) use the
supplied set of keys.

Device without printer

Removing / installing the monitor cover

Removing the monitor cover

Insert the supplied key into the lock and turn it in


the direction indicated by the arrow.

01750051417 C CERTO Floor-Standing Model - Installation Guide 39


Opening / closing the device Appendix

Remove the monitor cover.

Installing the monitor cover

Set the monitor cover on the crossbar and lock


it.

40 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Opening / closing the device

Removing / installing the rear cover

Removing the rear cover

Insert the supplied key into the lock and turn it in


the direction indicated by the arrow (1).

Swing the rear cover in the direction of the arrow


(2) and remove it.

Installing the rear cover

Hook the rear cover in the mounting holes (see


arrows) and lock the cover.

Make sure that the cables leave the device


through the openings in the rear cover and
that they are not crushed.

01750051417 C CERTO Floor-Standing Model - Installation Guide 41


Opening / closing the device Appendix

Device with printer

Pulling out the equipment carriage


Insert the supplied key into the lock and turn it in
the direction indicated by the arrow (1).

Grasp the equipment carriage (2) on the sides


and pull it out of the device as far as possible.

42 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Opening / closing the device

Pushing in the equipment carriage


Push the equipment carriage in the device until
it stops (1).

Turn the key in the direction indicated by the


arrow (2) and remove it from the lock.

01750051417 C CERTO Floor-Standing Model - Installation Guide 43


Opening / closing the device Appendix

Removing the front panel

• Pull out the equipment carriage (see section "Pulling out the equipment carriage").

Grasping it on both sides, pull the front panel


upwards to disengage the hooks (1).

Pull the front panel a little forwards (2) and set it


down carefully in front of the device.

Installing the front panel


Place the hooks of the front panel (1) on the
securing bolts at the sides (see arrows).

• Push the equipment carriage in and lock it (see section "Pushing in the equipment
carriage").

44 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Opening / closing the device

Removing / installing the rear cover

• Pull out the equipment carriage (see section "Pulling out the equipment carriage").

• Remove the front panel (see section "Removing the front panel").

Remove the four screws (1).

Remove the cover (2) at the rear.

Secure the rear cover by following the same steps in reverse order.

Make sure that the cables leave the device through the openings in the rear cover
and that they are not crushed.

01750051417 C CERTO Floor-Standing Model - Installation Guide 45


Check list for installation preparations for self-service systems Appendix

Check list for installation preparations for self-service


systems
KS number * Order number
Device type
Customer address Delivery address/location
Name
Street
City
Telephone
Contact

* Customer number or system's serial number

This check list has been created for all self-service systems. Most questions can be
answered yes or no. Some empty space is provided in the section "Notes concerning
installation preparation" for your convenience if you want to note any questions or drafts.

After checking off all items, copy this list, send it to your head of operations and
make arrangements for an installation date.

Name:

Telephone number:

Fax number:

46 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Check list for installation preparations for self-service systems

General information

Installation

in front of a wall through-the-wall free-standing encased

Yes No OK
Is the load carrying capacity of the floor sufficient according to
the installation documentation?
Is there floor heating in the installation area?
Are there cavities in the installation area (cable channel, raised
floor)?
Is the operation and maintenance space sufficient?
Is the equipment screened from external light (sunlight)?
Is a camera surveillance system to be installed?
Is a door opener system to be installed?

01750051417 C CERTO Floor-Standing Model - Installation Guide 47


Check list for installation preparations for self-service systems Appendix

Preparations

Construction work
Yes No OK
Is the securing of cash-dispensers in the raw concrete
ensured (CEN standard)?
Is the frame aligned and fastened in accordance with the
installation instructions?
Has a wall opening that may be required been completed?
Are the ambient conditions met?

Power and data cables


Yes No OK
Are the AC power outlets available in accordance with the
installation instructions?
Are the data cables available?
Is the alarm connection prepared?
Have the camera connection and the door opener been
provided?

Organizational preparations
Yes No OK
Is the generation prepared on the host?
Has the MM module or CIM86 been ordered and is it
available?
Have the encryption/decryption or EPP keys been prepared?
Is the paper and money ready for start-up?

48 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Check list for installation preparations for self-service systems

Delivery and installation


Yes No OK
Can a truck drive up to the installation location?
Are there steps or obstacles in front of the building?
If so, how many?

Are there steps or obstacles inside the building?


If so, how many?

Are there mats or grates at the entrance?

Flooring materials on the path of transport


(please check off)

Screed/concrete Wall-to-wall carpet Raised floor


Marble floor Tiles Others

Please enter the width of the most narrow door

Please enter the width of the most narrow hallway

Checked by customer: Checked by installation technician:

01750051417 C CERTO Floor-Standing Model - Installation Guide 49


Check list for installation preparations for self-service systems Appendix

Notes concerning installation preparation

50 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Check list for installation preparations for self-service systems

01750051417 C CERTO Floor-Standing Model - Installation Guide 51


Technical data Appendix

Technical data

General installation conditions

Electrical characteristics of the supply network


Line voltage range: 110 - 120 V 220 - 240 V
Rated frequency: 50/60 Hz 50/60 Hz
Network type: TN (network with PE TN (network with PE
conductor) conductor)
Permissible tolerance for
rated voltage: ± 10 % ± 10 %
Admissible tolerance for
rated frequency: ±1% ±1%

Device conditions
110 - 120 V 220 - 240 V
Idle mode Operation Idle mode Operation
(maximum) (maximum)
Rated current consumption: 0.79 A 1.34 A 0.46 A 0.74 A
Apparent power 94 VA 162 VA 105 VA 170 VA
consumption:
Active power: 62 W 147 W 62 W 146 W
Power factor: 0.66 0.91 0.59 0.85
Protection class: Ι Ι
Leakage current: 1.15 mA 1.15 mA
Type of system connection
(wall outlet): Country-specific safety plug Country-specific safety plug
Fuse protection: 10 A slow-blow fuse or 16 A 10 A slow-blow fuse or 16 A
circuit-breaker circuit-breaker
Degree of protection in
accordance with EN 60529: IP 20 IP 20

52 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Technical data

Installation conditions
CERTO Floor-Standing Model
Dimensions:
Height: 1542 mm (60.71")
Width: 472 mm (18.58")
Depth:
CERTO without printer: 245 mm (9.65")
CERTO with printer: 269 mm (10.59")
CERTO with printer and keyboard: 435 mm (17.13")

Height incl. base plate: 1552 mm (61.1")


Width incl. base plate: 720 mm (28.35")
Depth incl. base plate: 720 mm (28.35")

Operation and maintenance space: 1.96 m² (21.09 ft²)

Device weight: max. 78 kg (171.99 lb)

Detailed information concerning the dimensions is provided in the chapter


"Planning the Installation", section "Device dimensions".

01750051417 C CERTO Floor-Standing Model - Installation Guide 53


Technical data Appendix

Environmental conditions

Climatic environmental conditions in accordance with EN 60721

Class Ambient temperature Relative humidity


°C % r.h.
Operation (indoors): 3K2 + 15 to + 35* 10 to 75
Limit range of
operation: ** 3K3 + 5 to + 40 5 to 85
Transport: 2K2 - 25 to + 60 15 to 98
Storage: 1K2 + 5 to + 40 5 to 85

* The temperature value of + 35 °C deviates from the value of the standard (+ 32 °C).
** In the limit range the device may only be operated for a short period of time.

Mechanical environmental conditions in accordance with EN 60721

Class Remarks
Operation 3M2 Building with minimal external vibration
Transport 2M2 All types of commercial vehicles and trailers as well
(in original packing) as rail and air transport
Storage 1M3 Noticeable vibration and bumps caused for
(in original packing) example by machines or passing vehicles

Noise emission in accordance with EN 27779

Noise rating according to ISO 9296 Idle mode Operation ***


Sound power level LWAd Not applicable < 6.6 B
Workplace-related sound pressure level LpAm Not applicable < 49 dB
(at adjacent workplace)

*** typical operating cycle

54 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Technical data

Compliance with standards and certifications

Standards met

Safety standards:
IEC 950
EN 60950
C22.2 - 950

EMC standards:
EN 55022 class B
EN 55024
FCC CFR 47, part 15, subpart B, class A

Conformity
The CE mark of conformity attached to the product or its package indicates that the
product complies with the requirements of the following EC directives:

EMC Directive 89/336/EEC including amending directive 93/68/EEC


Low Voltage Directive 73/23/EEC including amending directive 93/68/EEC

The corresponding statement of compliance has been issued by

Wincor Nixdorf International GmbH


Heinz-Nixdorf-Ring 1
33106 Paderborn
Germany

Notes concerning radio interference suppression and electrical safety


All other device connected to this product must comply with the EMC Directive
89/336/EEC including the amending directive 93/68/EEC and the Low Voltage Directive
73/23/EEC including the amending directive 93/68/EEC.

01750051417 C CERTO Floor-Standing Model - Installation Guide 55


Technical data Appendix

FCC rules and Canadian Standard ICES - 003


NOTE: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC rules and Canadian Standard ICES - 003.
These limits are designed to provide reasonable protection against harmful interference
when the equipment is operating in a commercial environment. The equipment generates,
uses and can radiate high frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.

Certification for data transmission


The certification number or CE mark of the data transmission module (if available) is
attached to the DT card or to the housing of the system unit.

56 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Environmental protection

Environmental protection

Environmentally friendly product design and development


This product has been designed according to our corporate standard 'Environmentally
friendly product design and development'.

This means that crucial criteria such as long life, choice of material and its labeling,
emissions, packaging, ease of disassembly and recyclability have been taken into
account. This saves resources and relieves the strain on the environment.

Saving energy
Please switch on devices that need not be constantly running only when they are actually
needed. They should also be turned off when they are not needed for longer periods of
time.

Disposing of used consumables


Please dispose of printer consumables, batteries and cleaning and maintenance materials
according to national regulations (where relevant complying with vendor specifications).

Labels on plastic case parts


Please do not stick any labels on plastic case parts since that would make recycling more
difficult.

Returning, recycling and disposing of used units and consumables


Details regarding the return and recycling of used units and consumables can be obtained
from your local branch office or from our Recycling Center in Paderborn:

Tel.: +49 (0) 52 51 8-1 80 10 Fax.: +49 (0) 52 51 8-1 80 15

Further information
can be obtained from our Environmental Protection section (Referat Umweltschutz):

Tel.: +49 (0) 52 51 693-67 07 Fax.: +49 (0) 52 51 693-67 09


Email: referat.umweltschutz@wincor-nixdorf.com

01750051417 C CERTO Floor-Standing Model - Installation Guide 57


Scale drawings (scale 1:20) Appendix

Scale drawings (scale 1:20)

Device overview

CERTO Floor-Standing Model with base plate

Device without printer and without swipe card reader or insertion reader

58 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Scale drawings (scale 1:20)

Device with swipe card reader

01750051417 C CERTO Floor-Standing Model - Installation Guide 59


Scale drawings (scale 1:20) Appendix

Device with insertion reader

60 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Scale drawings (scale 1:20)

Device with keyboard and swipe card reader

01750051417 C CERTO Floor-Standing Model - Installation Guide 61


Scale drawings (scale 1:20) Appendix

Device with swipe card reader, barcode scanner and keyboard

62 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Scale drawings (scale 1:20)

Device with printer

01750051417 C CERTO Floor-Standing Model - Installation Guide 63


Scale drawings (scale 1:20) Appendix

Device with printer and swipe card reader

64 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Scale drawings (scale 1:20)

Device with printer and insertion reader

01750051417 C CERTO Floor-Standing Model - Installation Guide 65


Scale drawings (scale 1:20) Appendix

Device with printer, swipe card reader, barcode scanner and keyboard

66 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Scale drawings (scale 1:20)

CERTO Floor-Standing Model without base plate

Device with swipe card reader and barcode scanner

01750051417 C CERTO Floor-Standing Model - Installation Guide 67


Scale drawings (scale 1:20) Appendix

Device with keyboard

68 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Scale drawings (scale 1:20)

Device with swipe card reader, barcode scanner and keyboard

01750051417 C CERTO Floor-Standing Model - Installation Guide 69


Scale drawings (scale 1:20) Appendix

Space required for operation and maintenance

CERTO Floor-Standing Model with base plate

Required maintenance space

70 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Appendix Scale drawings (scale 1:20)

CERTO Floor-Standing Model without base plate

Required maintenance space

01750051417 C CERTO Floor-Standing Model - Installation Guide 71


Scale drawings (scale 1:20) Appendix

Transport

72 CERTO Floor-Standing Model - Installation Guide 01750051417 C


Notes

01750051417 C CERTO Floor-Standing Model - Installation Guide


Published by
Wincor Nixdorf International GmbH
33094 Paderborn
Germany

Printed in Germany
Order No.: 01750051417 C 1 GB

You might also like