Modified Parameter Settings Report (Program) 10/8/2022 10:10:04 AM

Program (Drive Selected / Connected):

Drive Type / Model: A1000 CIMR-A*4*0088***


Software: 1024

Project:
User:

Information

Default
Parameter Value Information Setting
A1 Initialization
A1-02 Control method 3 Flux vector 2
b1 Operation Mode Selection
b1-03 Stopping method 1 Coast to stop 0
C1 Acceleration and Deceleration Times
C1-01 Acceleration time 1 0.5 sec 10.0 sec
C1-02 Deceleration time 1 1.1 sec 10.0 sec
C1-03 Acceleration time 2 0.0 sec 10.0 sec
C1-04 Deceleration time 2 0.0 sec 10.0 sec
C1-05 Acceleration time 3 for motor2 0.0 sec 10.0 sec
C1-06 Deceleration time 3 for motor2 0.0 sec 10.0 sec
C1-07 Acceleration time 4 for motor2 0.0 sec 10.0 sec
C1-08 Deceleration time 4 for motor2 0.0 sec 10.0 sec
C1-09 Emergency stop time 0.0 sec 10.0 sec
C2 S-Curve Characteristics
C2-02 S-curve acceleration at end 0.00 sec 0.20 sec
C2-03 S-curve deceleration at start 0.00 sec 0.20 sec
C5 Speed Control (ASR)
C5-01 ASR proportional (P) gain 1 39.00 20.00
C5-02 ASR integral (I) time 1 1.300 sec 0.500 sec
C5-03 ASR proportional (P) gain 2 10.00 20.00
C5-04 ASR integral (I) time 2 1.900 sec 0.500 sec
C5-18 Load Inertia ratio 10.0 1.0
C6 Carrier Frequency
C6-02 Carrier frequency selection 02 Fc = 5.0kHz 01
d1 Frequency Reference
d1-01 Frequency reference 1 40.00 Hz 0.00 Hz
d5 Torque Control
d5-01 Torque Control Selection 1 Torque Control 0
E1 Motor 1 V/f Pattern Characteristics
E1-13 Base voltage 400.0 VAC 0.0 VAC
E2 Motor 1 Setup
E2-02 Motor rated slip 0.50 Hz 1.33 Hz
E2-04 Number of motor poles 2 4

DriveWizard Industrial for Windows (C) by Yaskawa America, Inc. 1/2