You are on page 1of 5

I SO 4

I SO 1
.
01 00

40
1

5
. ID16/03504 ID05/66527 ID21/05663
Photovoltaic Solar Cables
in used as Photovoltaic cable between solar modules and inverters.

Low Voltage Power Cables


mainly design for electrical power transmission and distribution lines with rate voltage AC or DC 0.6/1
(1.2) kV up To 1.8/3 (3.6) kV, and are suitable for installation in tray, ground, duct and lating directly into
the ground

Building & Earting Cables


mainly design for connection between electric device. application for indoor, in ducts installation for laying
in the ground, where not sustain mechanical damage or internal wiring in dry location

Medium Voltage Power Cables


mainly design for electrical power transmission and distribution lines with rate voltage AC 3.6/6 (7.2) up
To 18/30 (36) kV, and are suitable for installation in tray, ground, duct and lating directly into the ground
Fixed installation

DIMENSIONAL DATA
Nominal Thickness Approximately Standard
Nominal cross-
Outer Overall Net delivery
sec�onal area Insula�on
sheath diameter Weight length
mm² mm mm mm Kg/Km m
1.5 0.7 0.8 5.0 34 100 or 1000
2.5 0.7 0.8 5.4 45 100 or 1000
4 0.7 0.8 5.8 62 100 or 1000
6 0.7 0.8 6.3 80 100 or 1000
10 0.7 0.8 7.4 123 100 or 1000
16 0.7 0.9 9.0 200 1000
25 0.9 1.0 11.1 308 1000
35 0.9 1.1 12.5 403 1000
50 1.0 1.2 15.0 575 1000
70 1.1 1.2 16.6 740 1000
95 1.1 1.3 19.5 962 1000
120 1.2 1.3 21.0 1206 500
150 1.4 1.4 23.0 1500 500
185 1.6 1.6 26.5 1846 500
240 1.7 1.7 29.0 2385 500
ELECTRICAL DATA
Current carrying capacity
Resistance at 20°C
Nominal cross- at 60°C
sec�onal area DC conductor Insula�on Single cable
max. min. free in air
mm² Ω/km M.Ω.km A
1.5 13.7 1050 30
2.5 8.21 862 41
4 5.09 709 55
6 3.39 610 70
10 1.95 489 98
16 1.24 393 132
25 0.795 395 176
35 0.565 335 218
50 0.393 314 276
70 0.277 291 347
95 0.210 258 416
120 0.164 249 488
150 0.132 260 566
185 0.108 268 644
240 0.0817 249 775
Note : This is only general information. For other specific requirement, please contact our marketing.
LOW VOLTAGE POWER CABLES
PVC/XLPE Insulated, Non armour, armour
Standar Ref. : IEC 60502-1, IEC 60332-1, IEC 60228
Mainly design for electrical power transmission and distribution lines with rate voltage AC or
DC 0.6/1 (1.2) kV up To 1.8/3 (3.6) kV, and are suitable for installation in tray, ground, duct and
lating directly into the ground

Conductor Aluminium or Copper


Insulation PVC/ XLPE
Bedding PVC/LSZH
Armour *) Aluminium wire armoured (AWA)
(for single core cables) or Steel wire
armoured (SWA)
(for multicore)
Sheath PVC/LSZH
*) Other construction avaliable upon request.

Type cable Rated voltage Special feature Dimensional Data


No. of core Core 1~5
Cu/PVC/PVC (NYY) Al/PVC/PVC (NAYY) 0.6/1 (1.2) kV
Size of cable mm² 1.5 ~ 1000
Cu/PVC/(SWA/DSTA)/PVC (NYRGbY / NYBY) 0.6/1 (1.2) kV Armour
Electrical data
Al/PVC/(SWA/DSTA)/PVC (NAYRGbY / NAYBY) 0.6/1 (1.2) kV Armour
Rated Voltage Test voltage
Cu/XLPE/PVC (N2XY) Al/XLPE/PVC (NA2XY) 0.6/1 (1.2) kV 0.6/1 (1.2) kV 3.5 kV/5 min
Cu/PVC/PVC (NYSY) Al/PVC/PVC (NYSY) 0.6/1 (1.2) kV Screen 1.8/3 (3.6) kV 6.5 kV/5 min
Cu/XLPE/(SWA/DSTA)/PVC (N2XRGbY / N2XBY) 0.6/1 (1.2) kV Armour
Al/XLPE/(SWA/DSTA)/PVC (NA2XRGbY / NA2XBY) 0.6/1 (1.2) kV Armour
Cu/PVC/PVC (NYSY) Cu/XLPE/PVC (N2XSY) 1.8/3 (3.6) kV Screen
Cu/PVC/(SWA/DSTA)/PVC (NYRGbY / NYBY) 1.8/3 (3.6) kV Armour
Al/PVC/(SWA/DSTA)/PVC (NAYRGbY / NAYBY) 1.8/3 (3.6) kV Armour

BUILDING EARTING & CONTROL CABLES


Manfuacturing Spec. IEC 60228, IEC 60502-1, BS EN 50288-7,
Rate voltage 300/500 V up To 0.6/1 (1.2) kV
This cable is suitable for trasmiting signal and control system.
Type cable Rated voltage
Cu/PE/PVC (MSEV) 300/500 V
Cu/PE/PE/CWB/PE (MEV-SB) 300/500 V
Cu/XLPE/PE (N2X2Y) 0.6/1 (1.2) kV
Cu/XLPE/PE/DSTA/PE (N2X2YB2Y) 0.6/1 (1.2) kV

Conductor Round Copper wire (class 1 or class 2)


Insulation Polyetylene or Cross linked Polyetylene
Shielded Aluminium Foil/ Braided
Inner sheath Polyetylene / LSZH/PVC
Armourin Double steel tape
Outer Sheath Polyetylene / LSZH/PVC

Dimensional Data
Rated voltage Special feature No. of core Core 2 ~ 50
Cu/PVC/PVC (NYM) 300/500 V Size of cable mm² 0.5 ~ 10

Cu/PVC (NYA) 450/750 V Electrical data


Cu/PVC (NYAF) 450/750 V Flexible Max. Conductor
Size of core Test voltage
Cu/PVC/PVC (NYYHY) 450/750 V Flexible res. at 20 °C

Cu/PVC/TCCAB/PVC (YSLCY) 450/750 V Flexible, Braided Screen mm ohm/km kV/min


0.5 36
Cu/PVC/PVC (NYY) 0.6/1 (1.2) kV
0.75 24.5
Cu/PVC/(SWA/DSTA)/PVC (NYRGbY / NYBY) 0.6/1 (1.2) kV Armour 1 18.1 300/500 V =
2 kV/min
Cu/PVC/CTS/PVC (NYSY) 0.6/1 (1.2) kV Copper tape 1.5 12.1 0.6/1 (1.2) kV =
Cu/PVC/CWS/PVC (NYCY) 0.6/1 (1.2) kV Copper wire + copper tape 4 64 3.5 kV/5 min
6 30
1.2 16
MEDIUM VOLTAGE POWER CABLES
XLPE Insulated, armour and without armour.
Standar Ref. : IEC 60502-2, IEC 60332-1, IEC 60228

Mainly design for electrical power transmission and distribution lines with rate voltage
AC 3.6/6 (7.2) up To 18/30 (36) kV, and are suitable for installation in tray, ground, duct
and lating directly into the ground

Conductor Aluminium or Copper


Conductor Screen Semi-conductive Compound
Insulation Cross linked polyetylene (XLPE)
Insulation Screen Semi-conductive Compound
Metallic screen Copper tape or Copper wire
Bedding PVC/LSZH
Armour *) Aluminium tape/wire armoured
(AWA/DATA) (for single core cables)
or Double Steel Tape Armoured (DSTA)
Sheath PVC/LSZH
*) Other construction avaliable upon request.

Type cable Special feature


Cu/XLPE/PVC (N2XSY)
Al/XLPE/PVC (NA2XSY)
Cu/XLPE/CTS/(AWA/DATA)/PVC (N2XSRY / N2XSBY) Armour
CuXLPE/CTS//DSTA/PVC (N2XSEBY) Armour
AlXLPE/CTS/DSTA/PVC (NA2XSEBY) Armour

Dimensional data :
No. of core Core 1~5
Size of cable mm² 1.5 ~ 1000
Electrical data :
Rated Voltage Test voltage
3.6/6 (7.2) 12.6 kV/5 min
6/10 (12) 21 kV/5 min
8.7/15 (17.5) 30 kV/5 min
12/20 (24) 42 kV/5 min
18/30 (36) 63 kV/5 min

Note : this for general information for more detail specification


and other construction please contact our marketing

2023