You are on page 1of 4

Battery Management System Protection Mode

1. Electrical Characteristics

1.1 Electrical Characteristics (Note: Specifications with 25°C, unless otherwise stated.)

No. Item Parameter Remark


Cell Over-charge Voltage
3700mV
Alarm
Cell Over-charge Voltage
Cell Over-charge 3850mV
Protection
Cell Over-charge
1.0S
1 Protection Delay Time
Cell Over-charge Release 3400mV

Cell Over-charge Capacity Release SOC<96%

Protection Release
Discharge Current >
Release Once Discharge
1.0A
Cell Over-discharge
2700mV
Voltage Alarm
Cell Cell Over-discharge
2500mV After 30S, the
Over-discharge Voltage Protection
state get
Cell Over-discharge
2 1.0S changed to
Protection Delay Time
low-power
Cell Over-discharge
Cell 2900mV mode
Release
Over-discharge
Charger Connection is
Protection Release Release Once Charge
detected
Pack Over-charge Voltage
55.0V
Alarm
Pack Over-charge Voltage
Pack Over-charge 56.0V
Protection
Pack Over-charge
1.0S
3 Protection Delay Time
Pack Over-charge
50.2V
Release
Pack Over-charge
Capacity Release SOC<96%
Protection Release
Discharge Current >
Release Once Discharge
1.0A

Page 1 of 4
Pack Over-discharge
43V
Voltage Alarm
Pack Pack Over-discharge
39V After 30S, the
Over-discharge Voltage Protection
state get
Pack Over-discharge
4 1.0S changed to
Protection Delay Time
low-power
Pack Over-discharge
Pack 43.5V mode
Release
Over-discharge
Charger Connection is
Protection Release Release Once Charge
detected
Over-current Charge
45A
Alarm
Over-current
Over-current Charge
Charge 51A
Protection
Protection-1
5 Over-current Protection
2.0S
Delay Time
Over-current Auto Release After 1min
Protection-1 Discharge Current >
Release Once Discharge
Release 1.0A
Over-current Charge
Over-current ≥80A
Protection-2
Charge
Over-current Protection-2
Protection-2 200mS
6 Delay Time
Over-current Auto Release After 1min
Protection-2 Discharge Current >
Release Once Discharge
Release 1.0A
Over-current Discharge
52A
Alarm
Over-current
Over-current Discharge
Discharge 560A
Protection
Protection-1
7 Over-current Protection
1.0S
Delay Time
Over-current Auto Release After 1min
Protection-1 Charge Current >
Release Once Charge
Release 1.0A
Over-current Discharge
Over-current ≥80A
Protection-2
Discharge
Over-current Protection
Protection-2 300mS
8 Delay Time
Over-current Auto Release After 1min
Protection-2 Charge Current >
Release Once Charge
Release 1.0A

Page 2 of 4
Short Circuit Threshold ≥350A

Short Circuit Current


Short Circuit ≤500μS
9 Protection Delay Time
Current Protection
Charge Current >
Short Circuit Current
1.0A
Protection Release
Remove The Load
MOS Over Temperature
90℃
Alarm
MOS
MOS Over Temperature
10 Over-Temperature 110℃
Protection
Protection
MOS Over Temperature
85℃
Protection Release
Under Temperature
5℃
Charge Alarm
Under Temperature
0℃
Charge Protection
Under Temperature
Charge Protection 5℃
Release
Over Temperature Charge
50℃
Alarm
Over Temperature Charge
55℃
Protection
Over Temperature Charge
50℃
Protection Release
Cell Temperature
11 Under Temperature
Protection -10℃
Discharge Alarm
Under Temperature
-20℃
Discharge Protection
Under Temperature
Discharge Protection -10℃
Release
Over Temperature
50℃
Discharge Alarm
Over Temperature
65℃
Discharge Protection
Over Temperature
Discharge Protection 60℃
Release
ENV Under Temperature
ENV Temperature 0℃
12 Alarm
Alarm
ENV Under Temperature -25℃

Page 3 of 4
Protection
ENV Under Temperature
-20℃
Protection Release
ENV Over Temperature
50℃
Alarm
ENV Over Temperature
70℃
Protection
ENV Over Temperature
65℃
Protection Release

30mA(with LCD)
Operation Mode
13 Consumption
20mA(without LCD)

Low Power Mode 100μA


Balance Threshold 3500mV Charging or
14 Cell Balance
ΔVcell 20mV Fully
No alarm when
Low Capacity Alarm SOC<5%
15 Capacity charging
Full Capacity 50AH
Sleep voltage 3300mV
16 Sleep
Delay time 5min
Pack fullcharge voltage 52.5V
17 Full charge
Pack fullcharge current 1A

Page 4 of 4