You are on page 1of 2

TECHNICAL SPECIFICATIONS FOR HEAVY DUTY COMPRESSOR

SL NO. Description Parameters/Specifications


1. Inlet Conditions
a. Maximum Working Pressure 7.5 kg/cm2g
b. Design Temperature 46 deg C or Higher
2. Compressor Performance Data
a. Capacity(Free Air Delivery) 1040 cfm or more
b. Normal Working Pressure 7 kg/cm2g
c. Operating Conditions + 5 to +50 deg C & 1000 m
d. No. Of Stages Single
e. Cooling System Air Cooled
f. Type of Drive Direct Coupled
g. Starter Type Star-Delta
h. Capacity Control System Modulation Control For 100% to
60% for Power Saving

3. Electrical Data
a. Main Motor 160 KW or Less
b. Main Motor Efficiency Class IE2 or Better
c. Enclosure TEFC , Sq. Cage Induction Motor
d. Power Supply 3 Phase, 415 V +/- 10%, 50 Hz +/-
5%
e. Speed 1487 RPM
f. Insulation Insulation Class- F/Temperature
Rise-F
g. Motor Pole 4 Pole
h. Main Motor Frame Size & Mounting Type Motor : 315 Frame,IMB35 Flange
cum Foot Mounted

j. Accepted Motor Make ABB/SIEMENS/BBL/LHP


4. Performance Measurement Standards
a. Performance Test As Per ISO 1217Ed 3 Annexure-
C,1996/IS:5456-2006 & IS:10431

b. Duty Indoor
c. Capacity and Power Acceptance Test In Vendor Factory
5. Refrigerated Air Dryer
a. Capacity 1250 CFM or More
b. Dew Point 3 to 5 deg C PDP
c. Type of Cooling Air Cooled
d. Refrigerant R407C/Environment friendly CFC
Free
e. Accepted Make Same as Compressor Make