You are on page 1of 55

Introduction to

Peakvue
Objectives
 To Understand:
– 1. What Peakvue Is!
– 2. How it Works!
– 3. Filter Options
• Types of filters available
• Calculating the correct filter setting

• Filter Guidelines

– 4. Peakvue Data
• Spectrums and Waveforms
• Diagnosing Faults
– 5. Peakvue Versus Demodulation Techniques
– 6. Acquiring Peakvue Data using the 2120A
What is Peakvue™
 What is Peakvue?
– Peakvue is a technology unique to CSI and means ‘Peak Value’
– Such as the Peak Value of an impact generated by a bearing defect in a
time waveform - (True Peak Value)
– If you have a 21XX analyzer you have the capability to acquire
‘Peakvue Data’

 The ‘True Peak Value’ is obtained by concentrating on ‘Stress Wave


Analysis’ rather than conventional vibration data.

 These stress waves travel further than conventional vibration signals


so a truer indication of fault severity is obtained.
What is Peakvue™
 What is a Stress Wave?
 Stress waves accompany metal-metal impacting. These stress waves
are short-term (fractional to a few milliseconds) transient events,
which introduce a ripple effect on the surface machinery as they
propagate away from the initial event.
– If you think of a stone being dropped into a pool of water. The stone is
the initial impact generated by the fault. The effect of the stone being
dropped into the water cause a ripple on the surface of the water which,
spreads over a wide area.

Initial Impact
What is Peakvue
 If a bearing has a sub-surface defect (early bearing wear), when a
rolling element passes over the defect it bends the race slightly and
then as the rolling element passes it restores back to it’s natural state.

 This event causes a high frequency (1-50KHz) short duration stress


wave.
 This is what Peakvue detects
How Does It Work?
Digital
High Full
Peak
Vibration Pass Wave FFT
Signal Impact
Filter Rectify
Detection

 A comparison can be made of the sampling to show how data is


collected through both methods of data acquisition, normal and
Peakvue™.
How Does It Work?
 The diagram below shows sampling of data using normal data
collection.
Stress wave- this is missed
under normal conditions

Instantaneous Samples
How Does It Work?
 The diagram below shows sampling of data using Peakvue™ data
collection.

Stress wave- this is missed


under normal conditions

Peakvue Samples
How Does It Work?
 Peakvue measures the highest amplitude found in a stress waves
(Pk Value) and holds that data

 The waveform data is then passed through a high pass filter to


remove the unwanted, low frequencies
– Imbalance, Misalignment, Looseness, resonance etc.

 This just leaves us with the high frequency impacting data


(Peak) above the machine noise level

 The data is then brought back to fundamental frequency. (this


allows analysis of the data to be done quicker and easier)
Filters
Types of filter available
Filter Calculations
Filter Guidelines
Filters Options
 One of the key elements in acquiring meaningful peakvue data is the
selection of ‘filters’
 Selecting the wrong type of filter will result in poor quality data
– To much noise filtered through (the spectrum becomes very noisy)
– To much is filtered out (The stress wave is not allowed to pass through)

 There are two types of filter options in Peakvue, these are:


– 1. Band Pass Filter
– 2. High Pass Filter
 Each of the filters are designed to remove unwanted data out of the
signal at the appropriate levels
Filter Options - ‘High Pass Filter’
 High Pass Filters remove all frequencies from the data below the filter
setting but allow the high frequency stress wave to pass through.

All low frequencies Stress Wave data is allowed


are removed from to pass through the filter
the input signal

High Pass Filter


Filter Options - ‘Band Pass Filters’
 Looks for stress waves within a parameter defined by the filter setting.
Frequencies above and below this setting are removed from the data

Data passes
through filter

Data is Data is
filtered out filtered out
of the signal of the signal
Filter Selection
 To select the correct filter we need to consider the highest operational
defect frequency that we want to measure/detect. Then select the next
available filter above that frequency

 E.g.
– Consider a typical motor / pump arrangement. We have:
• 1 - 4 Pole A.C. Induction Motor
• 2 - 3 Jaw Coupling
• 3 - Centrifugal Pump
– Typically the highest defect frequency to emit from this machine would
be?
• 1 - BPFI - Bearing Defect
Filter Selection
 4 Pole Motor A.C Induction fitted with bearings SKF 6313
– Defect Frequencies (Orders)
• FTF - 0.384
• BSF - 2.037
• BPFO - 3.071
• BPFI - 4.929
 Typically we would want to see the 10th Harmonic of the BPFI
– Highest defect frequency:
• (BPFI x 10) x Turning Speed (Hz)
• (4.929 x 10) x 25
• 1232.3 Hz
– We would then select the next available filter setting above the frequency
Available filters
 High Pass Filters  Band Pass Filters
– 500hz – 20hz – 150hz
– 1000hz – 50hz – 300hz
– 2000hz – 100hz – 600hz
– 5000hz – 500hz – 1khz
– 10000hz
– 20000hz

From our previous calculation of 1232Hz, What filter setting would we select?

Note: the meter will only allow you to select the next
filter above the specified Fmax.
Filter uses (Band Pass) - Guidelines
 Band Pass Filters
– 20hz – 150hz Felt problems on paper machines
– 50hz – 300hz Certain structural resonance excitation,
modulation of gearmesh in low speed machinery
– 100hz – 600hz Gearmesh modulation in intermediate
speed machinery.
– 500hz – 1khz Gearmesh modulation

Tip: use bandpass filters when the event of interest is the


excitation of a structural resonance, or the modulation of
known frequencies – such as gearmesh.
Filter uses (Highpass) - guidelines
 High Pass filters
– 500hz Low speed machinery having <125hz. Bearing & gearing problems
– 1000hz Intermediate speed machinery (<2000 rpm) with gear mesh <300hz
– 2000hz Medium speed machinery (<4000rpm) with gear mesh ,600hz
– 5000hz Machinery up to 9000rpm and gear mesh to 1500hz, Requires attention be
paid to how the sensor is mounted as well as the sensors frequency response.
– 10000hz High speed machinery with gear mesh up to 3000hz sensor must be
permanently mounted with a frequency response of 3db in the 30kHz or higher
range.
– 20000hz High speed machinery with gearmesh up to 6000hz. Sensor must be high
frequency and permanently mounted.

Tip: Use highpass filters when the objective is to detect stress


waves which are emitted by metal on metal impacting.
Filter Selection - Question
 Consider:
– Motor running at a speed of 1000RPM
– Driving a fan unit via pulley belts
– Fan Speed is 1350RPM
• Motor Bearings = SKF 3095 - BPFI 4.855
• Fan Bearings = SKF 6210 - BPFI 5.907

 Calculate what Filter setting would be required for both the motor
and the fan bearings?
– Filters Available:
• 500 Hz, 1000Hz, 2000Hz, 5000Hz, 10000Hz, 20000Hz. (High Pass)
• 20-150Hz, 50-300Hz, 100-600Hz, 500-1KHz. (Band Pass)
Filter Selection - Answers
 Motor Speed = 1000CPM / 60 = 16.667Hz
 Fan Speed = 1350CPM / 60 = 22.5Hz
 Motor.
– BPFI = 4.855
– Defect Frequency = (BPFI x 10) x Turning Speed (Hz)
– Defect Frequency = (4.855 x 10) x 16.667
– Defect Frequency = 809.18 Hz

 Filters Available:
• 500 Hz, 1000Hz,
1000Hz 2000Hz, 5000Hz, 10000Hz, 20000Hz. (High
Pass)
• 20-150Hz, 50-300Hz, 100-600Hz, 500-1KHz. (Band Pass)
Filter Selection - Answers
 Motor Speed = 1000CPM / 60 = 16.667Hz
 Fan Speed = 1350CPM / 60 = 22.5Hz
 Fan
– BPFI = 5.907
– Defect Frequency = (BPFI x 10) x Turning Speed (Hz)
– Defect Frequency = (5.907 x 10) x 22.5
– Defect Frequency = 1329.07Hz

 Filters Available:
• 500 Hz, 1000Hz, 2000Hz,
2000Hz 5000Hz, 10000Hz, 20000Hz. (High
Pass)
• 20-150Hz, 50-300Hz, 100-600Hz, 500-1KHz. (Band Pass)
Peakvue Data
Spectrums and Waveforms
Diagnostics Techniques
Peakvue - Spectrum
 Here is a typical Peakvue spectra plot.

2. Units should be ‘acceleration’


(Very high frequency analysis)

1. Broad band energy


- Filtered Noise

3. Amplitude values are low.


Severity of fault is not
determined in the spectra

 This is typically a GOOD spectrum


Peakvue - Spectrum
 This is a Peakvue spectrum where high frequency stress waves are
being detected
Notice the Impacts 2. Units still in ‘acceleration’
passing through the (Very high frequency analysis)
filtered noise

1. Broad band energy


- Filtered Noise

3. Amplitude values are low.


Remember severity of fault is
not determined in the spectra
 This is indication of a fault developing
Peakvue - Waveforms
 Waveforms can be confused with spectrums, as the waveform is only
plotting the peak value and does not show a full wave.
A1 - E x am ple 1
EX 1 -D3P Tail Roll Non D/S P e a kv ue
0 .6
Ana lyz e W av e form
2. Peak Value Impacts 16 -Ma r-01 12 : 03 : 1 4
(P kV ue- HP 50 0 Hz)
0 .5

PK = .05 5 6
LOAD = 1 00 .0
0 .4
RP M = 80 .
RP S = 1 .3 3
Acceleration in G-s

0 .3 PK(+) = .5 5 99
PK(-) = .03 97
CRE S TF= 1 4.2 5

0 .2

1. Filtered Noise Level


0 .1

4. Acceleration
0
as default units
-0.1

0 3 6 9 12
Rev olution Num be r

3. No Peak Negative Value


Label: E as y
Peakvue - Diagnostics
 Diagnosing a Peakvue spectrum and waveform is not to dissimilar to
that of conventional data.
 However there are a few differences which can be a bit confusing at first,
these are:
– 1. Do not try to locate 1xTurning Speed, as this is low frequency data and
will be filtered out.
• Turning speed should be entered using the conventional spectral data.
– 2. Multiple harmonics are often present within a spectrum due to the way
peakvue samples the data.
• These do not indicate ‘Looseness’
– 3. Spectral amplitudes are always low in amplitude but should not be used
to judge severity. Use the spectrum to diagnose the fault.
– 4. Waveforms indicate the severity of the problem.
Peakvue - Diagnostics
 Continued…..
– 5. Ensure the same filter setting is used in both the spectrum and
waveform.
• Potential faults can be missed or overlooked if different filters are used.
– 6. Cage Defects show up well in peakvue data and is normally an
indication the bearing is under stress.
– 7. All low frequency faults are removed from the data and will not be seen
in a Peakvue spectrum and waveform
• Imbalance, Misalignment, Looseness, Resonance - All Gone.
Peakvue - Diagnostics

1.Spectral data indicating a


defect at 5.463 Orders

3. Very Slow
RPM

2. Impacting also being


detected at 0.6G-s
Peakvue - Diagnostics
4.Fault Frequencies Indicate
a BPFI Defect
Peakvue™ Amplitudes -
Rolling Element Bearings
 For machines running between speeds of 900 - 3600RPM
recommended guidelines for setting initial warning levels in the
Peakvue™ time - waveform are as follows:

Alert Value Fault Value


Inner Race 3.0g's 6.0g's
Outer Race 6.0g's 12.0g's
Rolling elements fault 4.5g's 9.0g's

Cage frequencies If evident then the bearing is usually under


stress.
Peakvue™ Amplitudes -
Rolling Element Bearings
 For machines running at speeds <900RPM recommended guidelines
for setting initial warning levels in the Peakvue™ time- waveform are as
follows:
7
Levels for concern for machines running below 900 RPM

6
Inner race -
5.5
Amplitude (g's)
Outer race - 5.0 5
Amplitude (g's)
4.4 4.5
Rolling elements -

Acceleration g's
Amplitude (g's) 4.1
4
3.9
3.7

3.3 3.3
2.9 3
2.7
2.6
2.4 2.5
2.2
1.9 2.0 1.9 2
1.6
1.5
1.3
1.2
0.9 1.0 1
0.9
0.7
0.5 0.5 0.6
0.4
0.2
0.2 0.3
0.1 0
10 35 75 100 200 300 400 500 600 700 800 900
RPM
Peakvue Vs
Demodulation
Peakvue Vs Demodulation
 What is Demodulation?
– This is a technique which concentrates on stress wave analysis, but is
not as effective.
 How Does it Work?
– Demodulation looks for the ringdown that follows an impact, and tries to
measure how quickly it fades. In order to do this the ‘Time Waveform’
has to be manipulated in such away that the waveform data becomes
useless
Less than 1ms Initial Impact

Ringdown
Peakvue Vs Demodulation
 What are the Differences?
– Peakvue samples the data much quicker enabling it to catch the very
short duration high frequency stress wave. It then holds that ‘Peak
Value’ throughout its parameter.
– Due to the Analogue filtering system used by Demodulation, results in a
‘delay in response’ and the stress wave impact is missed

Demodulation registers Peak Impact Detection registers


Peakvue Vs Demodulation
The Process! Standard Demodulation

High Low Full Remove


A/D
Pass Pass Wave DC FFT
Converter
Filter Filter Rectify Bias

Enveloping Stage

Peak Impact Detection


Digital
High Full
Peak
Pass Wave FFT
Impact
Filter Rectify
Detection
Peakvue Vs Demodulation
 Case Study.
– Equipment
• A conveyor system consisting of six rolls is driven by a motor/gearbox unit (GMU).
• The motor speed is 1500RPM reduced through the gearbox giving the roller
speed to be 98.5RPM
Peakvue Vs Demodulation
 Data was collected on each bearing of the conveyor system
• Due to the slow speeds Peakvue and Demodulation Filters were both set to
500Hz High Pass using 1600 Lines of Resolution
P v D - E xa mple 1
P v D - E xa mple 1
E x1 -R1 P Rolle r Be a ring Driv e End (18 -De c -0 1)
E x1 -R1 P Rolle r Be a ring Driv e End 0 .0 5
0 0.0.016
7
Max Amp Ana lyz ee S
Spe
pectrum
ctrum
.04 90 c-011 14
18 -De c-0 14::120:
2:2360
(Dem
(P od-0HP
kV ue- .0 450
HP 5000 Hz)
Hz )
0 .0 6
Direct Comparison
Demodulation Spectra PK = .12
.02
0 .039
385
0 .0 12
0 .0 5 Between the Two LOAD == 1100
LOAD 00.0.0
PK Acceleration in G-s

RP M == 9997..
G-s
in G-s

Peakvue Spectra RP S == 11.6


.642
0 .0 2
Acceleration in
PK Acceleration

0 .0 4

0 .0 08 0 .0 1

0 .0 3 Peakvue
0
PK

1 8-Dec -01
0 .0 2 1 4: 1 0: 26
0 .0 04

0 .0 1
Demodulation
1 8-Dec -01
1 4: 1 0: 26
0
0 50 1 00 1 50 2 00
0 50 Freque1nc00y in Hz 1 50 2 00
Freque nc y in Hz
Label: P ea kv
Dem ue 5 00
odulate d Hz
5 00High P as sP as s
Hz High
Peakvue Vs Demodulation
P v D - E xa mple 1
E x1 -R1 P Rolle r Be a ring Driv e End

P lot
S pa n
1 .0 Demodulation
1 8-Dec -01 1 4: 22
Waveform
Acceleration in G-s

Peakvue Waveform

-0.2
1 8-Dec -01 1 4: 10

0 1 2 3 4 5 6 7
Rev olution Num be r
Acquiring Peakvue
Data
Setting up the 2120A
Creating a Peakvue AP Set
Setting up the 2120A
 Peakvue can be accessed from the ‘Analysis Expert’ options found
among the command keys of the 2120A
 There are two ways of acquiring peakvue data within the 2120A
– Bearing/Gear Analysis - Peakvue
• Preset to acquire Peakvue data based upon the AP set assigned to the
machine
– User Setup Option
• Allows user interface to define their own parameters
Setting up the 2120A
 User Set-up Option
– Define the Fmax you wish to go to. Remember the Fmax is going to
define your filter setting.
• 0 - 30 KCPM = 500Hz High Pass
• 30 - 60 KCPM = 1000Hz High Pass
• 60 - 120 KCPM = 2000Hz High Pass
• 120v - 300 KCPM = 5000Hz High Pass

 Lines of Resolution
– These have to be good enough to capture the FTF of a bearing, which
would equate to around 15 Revolutions of waveform data.
• Number of Revs = Number of lines / Fmax(Orders)
– E.g. 800 Lines over an Fmax of 60 Orders = 13.3 Revolutions (Inadequate)
– 1600 Lines over an Fmax of 60 Orders = 26.6 Revolutions (OK)
Setting up the 2120A
 Averages
– This has to be set to 1 Average to gain the ‘true peak’ value.
• If you start averaging the data then a stress wave detected in the first average
that is not there in the second will lose it’s true amplitude when averaged
together.
 Units
– The default unit for peakvue is ‘Acceleration’. Remember we are trying to
detect very high frequency events, well above conventional vibration data.
Acceleration accentuates high frequencies.
• Sensor units can be used if using an accelerometer, however CSI recommend
a minimum mounting of a ‘Rare Earth Magnet’ for data collection
 By using the ‘Page Down’ Button we can toggle through the pages until
we find our Peakvue Options (Page 4 of 4)
– We turn Peakvue to ‘Yes’
– The Pre-filter can now be changed to our required HP Setting
Setting up the 2120
 Data collection can now commence.
 Check the data once collection has finished
– Look for:
• Impacts in both spectrum and waveform
• Amplitude levels of the Waveform
• quality of the data
– If a problem is detected you may want to acquire more data with a
different filter setting.
– Remember to store the data once the reading has been taken

 At least one Peakvue point should be applied to each critical machine to


detect early bearing wear, gearwear or adverse metal to metal contact.
– This will need building in the database and adding to the route
Peakvue™
Analysis Parameter Setup
Mastertrend and RBMware
Peakvue™ AP Set up I

1. Open Database Management


2. Select Analysis Parameter
Peakvue™ AP Set up II
1. Complete the spectrum setup, specifying
Fmax, LOR and averages (1).
2. Specify the number of parameters - 2
Peakvue™ AP Set up III

1. Check, ‘Use Analog pre-processor


2. Select Peakvue, under the ‘Envelope
Demodulator’
3. Select the filter setting.
Peakvue™ AP Set up IV

1. Uncheck, ‘obtain special time


waveform?’ - As Default units will be
acceleration
2. Discard all settings when this is
unchecked
Peakvue™ AP Set up V

1. Complete Analysis Parameter


specifications, the most important parameter
is the ‘peak to peak’ waveform parameter.
2. Ensure ‘unit type’ is acceleration
Gearbox case study
Diagram

M1 G3 G5 G7
M2

G9 G11

G1

G10 G12

G8

G4 G6
Introduction
 The above gearbox had been overhauled in the workshop and
was on its final test run. A vibration signature was taken to
confirm a small knock believed to be coming from the coupling,
and prove the gearbox was OK.

 The readings were taken using Peakvue and standard


Vibration Technology on the corresponding points indicated in
the diagram above. The following spectrum where obtained.
Standard Data
The standard spectrum below was taken from G5. Is there a Problem?

M1
M2
G1

G3
G4

G5
G6

G7
G8
G10

G9
G12

G11
PeakVue™ Data
The Peakvue reading shows distinct energy at 6.941 Hz and
multiple harmonics of this which is the running speed of the
third shaft. The bottom waveform shows clearly a substantial
impacting of up to 12 G’s occurring each revolution.
The fault
 The diagram below indicates the location of the suspected gear fault
and was diagnosed as possibly a damaged tooth

Faulty Gear

M1 G3 G5 G7
M2
G9 G11
G1

G10 G12
G8
G4 G6

• When the gearbox was re-stripped and examined a cracked


tooth on the gear identified was found.

You might also like