1 GENERAL ELECTRICAL NOTES 2 3 LEGEND:
E-1 E-1 E-1
1. THE ELECTRICAL INSTALLATION HEREIN SHALL BE DONE IN
ACCORDANCE WITH THE PROVISIONS OF THE LATEST EDITION
OF THE PHILIPPINE ELEC. CODE, THE EXISTING LOCAL ORDINANCE
AND REQUIREMENTS OF THE LOCAL POWER COMPANY. 1 a
2. THE CONTRACTOR SHALL VERIFY AND ORIENT ACTUAL LOCATION
OF SERVICE ENTRANCE FOR CONNECTION TO POWER SUPPLY. ab
3. STANDARD AND APPROVED TYPES OF ACCESSORIES, SLICING DEVICES,
TERMINATION AND OTHER APPURTENANCES SHALL BE USED FOR abc
FOR THE ENTIRE ELECTRICAL INSTALLATION.
ab
4. ALL LIGHTS, SWITCHES AND RECEPTACLES SHALL BE MOUNTED
AT 1.2M AND AT 0.30M FROM FINISHED FLOOR RESPECTIVELY. 3W
5. PANELBOARD AND THE ENTIRE ELECT. SYSTEM SHALL BE PROPERLY
GROUNDED IN ACCORDANCE WITH THE PHILIPPINE ELECT. CODE.
6. ALL CONDUIT AND WIREWAYS LOCATED AND / OR INDICATED ARE
DIAGRAMATIC EXACT LOCATIONS IN ROOMS WALL PENETRATIONS.
M
7. GROUNDING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH
PHILIPPINE ELECTRICAL CODE.
8. BURIED GROUND CONDUCTORS SHALL BE AT LEAST 0.45M ( 18" )
BELOW FINISHED GRADE.
9. ALL ELECTRICAL WORKS SHALL BE UNDER THE DIRECT SUPERVISION
1 LOCATION PLAN
N.T.S
OF A DULY REGISTERED ELECTRICAL ENGINEER OR PROFESSSIONAL E-101
ELECTRICAL ENGINEER
i i v p
p
u
d
m l h c' c
o k
e f
j b d
p
j g
f a
i
f
c d
t o
k
d l g
a
e e e t
j
c c k h h
b
s
m o
s
q q n n
r r
LIGHTING LAYOUT LIGHTING LAYOUT
ELEVATION 2 GROUND FLOOR RCP 3 SECOND FLOOR RCP
E-101
1:100M E-101
1:100M
5 CONCRETE PEDESTAL DETAIL
E-1