You are on page 1of 1

GENERAL NOTES: LEGEND & SYMBOLS: WEATHER HEAD CAP CONCRETE POLE

1. ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH


SERVICE ENTRANCE PP POWER PANEL BOARD THIRD FLOOR LINE
THESE PLANS AND SPECIFICATIONS, THE APPLICABLE PROVISIONS OF THE LATEST
EDITION OF THE P.E.C. THE RULES AND REGULATIONS OF THE LOCAL ENFORCING
MERALCO POWER SOURCE
AUTHORITY AND THE REQUIREMENTS OF THE LOCAL POWER COMPANIES,THE CIRCUIT BREAKER
230 Vac, 60Hz, 2P, 3wire
ELECTRICAL WORKS SHALL BE UNDER THE IMMEDIATE SUPERVISION OF A DULY LIGHTING CIRCUIT LINE
LICENSED REGISTERED ELECTRICAL ENGINEER.
CIRCUIT HOMERUN
2. THE ELECTRICAL SERVICE VOLTAGE SHALL BE 1-PHASE, 3-WIRE, 230 VOLTS, 60 HZ. POWER CIRCUIT LINE

3. THE ELECTRICAL WIRING INSTALLATION SHALL BE DONE IN PVC CONDUIT. FLEXIBLE


GROUND LINE
CONDUIT SHALL BE USED WHERE REQUIRED MINIMUM SIZE FOR ALL CONDUITS SHALL BE KILOWATT-HOUR METER 2 - 80.0 Sq.mm THHN
15 mm DIA. ELECTRICAL TRADE SIZE, CONDUITS SHALL BE RIGID STEEL CONDUITS ( RSC) 1 - 14.0 Sq. mm. THW
AND SHALL BE USED IN MAIN SERVICE ENTRANCE.
9 WATTS CIRCULAR TYPE PINLIGHT IN 40 mm Ø RSC
PL
4. ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE "THHN" OR "THW" ONE GANG SWITCH SECOND FLOOR LINE
UNLESS OTHERWISE INDICATED, THE MINIMUM SIZE FOR POWER AND LIGHTING SHALL BE
2.0 SQ.MM THE CONTROL WIRES SHALL BE AS INDICATED OR SPECIFIED ELSEWHERE ON 18 WATTS DROP LIGHT
DL TWO GANG SWITCH
PLANS.
KW-HR METER
5. THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF SERVICE ENTRANCE
FOR CONNECTION TO THE POWER SUPPLY. 32 WATTS RING LIGHT W/ DIFFUSER THREE GANG SWITCH
RL
MAIN CKT. BRKR.
6. ALL SERVICE ENTRANCE EQUIPMENT, SWITCHES, PANELBOARDS, LIGHTING FIXTURES AND
200 AMPS. MDP PPN PPA PPN PPA
ALL NON-CURRENT CARRYING METAL PARTS SHALL BE PROPERLY GROUNDED IN TELEPHONE WALL OUTLET 300 A 100 A 100 A 100 A 175 A
ACCORDANCE WITH THE PHILIPPINE ELECTRICAL CODE.
25 WATTS WALL LAMP 1Ø 1Ø 1Ø 1Ø 1Ø

1.40
7. ANY DISCREPANCY IN LOCATION AND RATINGS OF EQUIPMENT AND APPARATUS SHALL BE
VERIFIED WITH THE OWNER OR ANY OF HIS REPRESENTATIVES AND CHANGES SHALL BE MADE CONVENIENCE OUTLET
ACCORDINGLY. 25 WATTS LAMP POST
GROUND FLOOR LINE

8. ALL MATERIALS TO BE USED AND THE EQUIPMENT TO BE INSTALLED SHALL BE BRAND NEW A ELEC. WATER HEATER E 8.0 SQ. MM BCW
EWH
ND MUST BE OF THE APPROVED TYPE FOR THE PARTICULAR LOCATION AND PROPOSED
RANGE
RANGE OUTLET GROUND LINE
INTENDED.
SAND & GRAVEL BEDDING
ACU CONVENIENCE OUTLET
9. THE MOUNTING HEIGHTS OF WIRING DEVICES SHALL BE AS FOLLOWS: CT
COUNTER TOP CONV. OUTLET ACU

A.) LIGHT SWITCHES - 1.40m ABOVE FLOOR FINISH.


B) CONVENIENCE OUTLETS - 0.30m ABOVE FLOOR FINISH. WEATHER PROOF CONV. OUTLET
WP
C.) PANELBOARDS AND CABINETS - 1.40 m ABOVE FLOOR FINISH OR REQUIRED.
D
E
O
S
P
RP
G
D
L
BLO
M
C
M
'YE
O
R
TSW
O
T

THE SITE
4794 E MERCADO ST. CORNER CALDERON
FROM PLDT ST. POBLACION, MAKATI CITY

THIRD FLOOR LINE

TTC2 CABLE NETWORK


KITCHEN
L2 PROVIDER

SECOND FLOOR LINE RESTAURANT


CATV

SECOND FLOOR LINE


TEL.
TTC1
PB COUNTER
L1 RG6 CABLE IN
RSC 20mm Ø uPVC
ELBOW CATV CATV (TYP.)
GROUND FLOOR LINE
SB PB
COUNTER
8.0 SQ. MM BCW
CATV
GROUND LINE
GROUND FLOOR LINE

USE 1-3.5 sq.mm TW(G)


SAND & GRAVEL BEDDING E
COORDINATE WITH CATV PROVIDER
VICINITY MAP

REG. NO. PROJECT TITLE: SHEET CONTENTS: SHEET NO:


P. T. R :

ISSUED AT : PROPOSED TWO STOREY COMM'L BLDG. AS SHOWN E


DATE ISSUED :
DAE YONG KIM
OWNER 001
DRAWN BY : DATE : CHECKED BY:
T. I. N : LOCATION : 4794 E MERCADO ST. CORNER CALDERON ST. POBLACION, MAKATI CITY

You might also like