You are on page 1of 19

OFFICE OF THE BUILDING OFFICIAL

LOT BEARINGS
PERSPECTIVE
TCT No.: 137-2022000747
A-1 S 10D., 22'E., 516.05 M
THIS SITE
1-2 N 75D., 39'W., 21.99 M
2-3 N 14D., 23'E, 12.01 M
3-4 S 75D., 36'E., 21.99 M
4-5 S 14D., 23'W., 1.40 M
5-6 S 14D., 23'W., 10.0 M
6-1 S 14D., 23'W., 0.60 M

3 6'
°3
75

21.9
9

4
1
12.0

1.40
5
14°23'

14°23'
0
10.0

21.9
9
9'

SITE DEVELOPMENT PLAN 75


°3
6
LOCATION PLAN
0.60

SCALE: 1:80MTR 1
SCALE: NDTS
PRC NO. D R Y S E A L APPROVED BY: CAD BY: CMF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 2-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
A-1
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:
OWNER'S SIGNATURE
DATE FINISHED
REFERENCE:
4.
1 5
OFFICE OF THE BUILDING OFFICIAL

1 2 3 4 5 6 1 2 3 4 5 6
A

D2
4 3 2 1

W1 W1 W1

4
3
2
1

C D2
D2 D3
D2

D D3
D2
15
15

E
14
14
13
13
12 D2
D2 12
11
11
10
10
9
9

D3
8
8
7
7
6
D3 6
5
5
4
4
3
3
2
2
1

F W1 W1 W2
1

W1

GROUND FLOOR PLAN SECOND FLOOR PLAN


SCALE: 1:100MTR SCALE: 1:100MTR
PRC NO. D R Y S E A L APPROVED BY: CAD BY: CMF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 2-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
A-1
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:
OWNER'S SIGNATURE
DATE FINISHED
REFERENCE:
4.
2 5
1 2 3 4 5 6
OFFICE OF THE BUILDING OFFICIAL

USING 4mm THICK LONG SPAN


RIB-TYPE ROOFING ON
C-PURLINS W/ 10mm THICK
DOUBLE INSULATION FOAM

15
14
13

12
11
10
9
8
7
6
5
USING 4mm THICK END 4
WALL FLASHING 3
2
1

WOODEN PANEL DOOR WOODEN PANEL DOOR


(SWING TYPE) PVC DOOR WITH LOUVER
(SWING TYPE)
BEDROOMS T&B
MAIN ENTRY AND EXIT

ROOF PLAN 1.00


0.60 0.60 0.60
SCALE: 1:100MTR

2"X3" RECTANGULAR

1.05

1.20
STEEL HANDRAIL

15

0.30
14

0.30
2ND FLOOR LANDING
13
15
0.20

0.30
14
0.20

12

DN

1.20
13
0.20

0.30
11

12
0.20

0.30
11
0.20

10

10
0.20

0.30
9
9
0.20

0.30
8
0.20

7
0.20

6 0.30
7
0.20

1/2"SQ.DIA. STEEL 5
0.30
0.20

REINF BARS FIXED WINDOW W/


6

4 SLIDING WINDOW W/
0.20

0.30

BARS EMBEDDED 3
ALUMINUM FRAMING ALUMINUM FRAMING
0.20

0.30

2
IN CONCRETE
0.20

BALCONY BALCONY
4

1 GROUND FLOOR LINE


0.30
3

0.30
2

0.30

DOOR AND WINDOWS SCHEDULE


1

STAIR DETAILS
SCALE: 1:20MTR SCALE: 1:50MTR

PRC NO. D R Y S E A L APPROVED BY: CAD BY: CMF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 2-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
A-1
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:
OWNER'S SIGNATURE
DATE FINISHED
REFERENCE:
4.
3 5
USING 0.4MM THICK LONG SPAN USING 0.4MM THICK LONG SPAN
RIB-TYPE ROOFING ON 2X4X1.5mm RIB-TYPE ROOFING ON 2X4X1.5mm
THICK C-PURLINS W/ 10mm THICK THICK C-PURLINS W/ 10mm THICK
DOUBLE INSULATION FOAM DOUBLE INSULATION FOAM
OFFICE OF THE BUILDING OFFICIAL

MANUAL GALVANIZED 0.6mm


SHUTTER ROLL UP DOOR

FRONT ELEVATION
SCALE: 1:100MTR REAR ELEVATION
SCALE: 1:100MTR

USING 0.4MM THICK LONG SPAN


RIB-TYPE ROOFING ON 2X4X1.5mm
THICK C-PURLINS W/ 10mm THICK
DOUBLE INSULATION FOAM

MANUAL GALVANIZED 0.6mm MANUAL GALVANIZED 0.6mm


SHUTTER ROLL UP DOOR SHUTTER ROLL UP DOOR

LEFT ELEVATION
SCALE: 1:100MTR RIGHT ELEVATION
SCALE: 1:100MTR

PRC NO. D R Y S E A L APPROVED BY: CAD BY: CMF REVISIONS : SHEET CONTENTS :

PTR NO.
PROPOSED 2-STOREY RESIDENTIAL BUILDING
WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
A-1
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:
OWNER'S SIGNATURE
DATE FINISHED
REFERENCE:
4.
4 5
OFFICE OF THE BUILDING OFFICIAL

USE 3.5MM THK FIBERCEMENT


BOARD ON METAL FURRING
(PAINTED WHITE)

USE GI MINIRIB CEILING


PANEL WHITE COLOR ON
METAL FRAMES

1 2 3 4 5 6 1 2 3 4 5 6
A

D2
4 3 2 1

W1 W1 W1

B
USE 3.5MM THK FIBERCEMENT
4 BOARD ON METAL FURRING
3 (PAINTED WHITE)
2
1

D2 C D2
D2 D3
D2

D D3
D2
15
15

E
14
14
13
13
12 D2
D2 12
11
11
10
10
9
9

D3
8
8
7
7
6
D3 6
5
5
4
4
3
3
2
2
1

F W1 W1 W2
1

W1

USE GI MINIRIB CEILING


PANEL WHITE COLOR ON
METAL FRAMES

REFLECTED CEILING PLAN REFLECTED CEILING PLAN

PRC NO. D R Y S E A L APPROVED BY: CAD BY: CMF REVISIONS : SHEET CONTENTS :

PTR NO.
PROPOSED 2-STOREY RESIDENTIAL BUILDING
CHECKED BY:
DESIGNED BY:
1.
2.
A-1
WITH ROOF DECK AND RETAILER
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:
OWNER'S SIGNATURE
DATE FINISHED
REFERENCE:
4.
5 5
GENERAL CONSTRUCTION NOTES OFFICE OF THE BUILDING OFFICIAL

GENERAL NOTES NOTES ON CONCRETE MIXES & PLACING


1.0 STANDARDS AND REFERENCES 1. ALL CONCRETE SHALL DEVELOP A MIN. COMPRESSIVE STRENGTH AT THE END OF TWENTY EIGHT
THE FOLLOWING SHALL GOVERN THE DESIGN FABRICATION AND CONSTRUCTION OF THE PROJECT. (28) DAYS W/ CORRESPONDING MAXIMUM SIZE AGGREGATE & SLUMP AS FOLLOWS. JOINT HOOP SPACE @ "2Sh" WHEN

D JOINT REINF. D PER SCHEDULE D JOINT REINF. D


MAX. SIZE OF THERE ARE BEAMS HAVING WIDTH OF
1.1 NATIONAL STRUCTURAL CODE OF THE PHILIPPINES (N.S.C.P 2015) VOL. 1, SEVENTH EDITION.
LOCATION 28 DAYS STRENGTH AGGREGATE MAX SLUMP AT LEAST ONE-HALF THE COLUMN
2.0 DESIGN CRITERIA WIDTH & DEPTHS NOT LESS THAN
ALL OTHERS, INCLUDING 4000 PSI (27.6 MPa) 20 mm 100mm THREE QUARTERS OF THE DEEPEST

CONF. REINF.
2.1 LOADINGS SUSPENDED SLABS BEAM THAT FRAME INTO FOUR
A. DEAD LOAD 4000 PSI (27.6 MPa) 20 mm 100mm SIDES OF THE COLUMN. ALL OTHER
COLUMNS CONDITIONS USE HOOPS @ "Sh" CENTERS.
CONCRETE 23.56 kN/m3 BEAMS 4000 PSI (27.6 MPa) 20 mm 100mm

Sh
76.93 kN/m3 20 mm 100mm

COLUMN TIES AS
STEEL SLAB ON FILL 2500 PSI (17.5 MPa)
2. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS. FOR COL. BAR SPLICES SEE TABLE
100 mm THK. CHB WALL 2.11 kPa 20mm
SUSPENDED SLABS OF MIN. LAP SPLICE LENGTH OF
B. LIVE LOAD COLUMN REINFORCEMENT
SLAB ON GRADE 40mm

CONF. REINF. CONF. REINF.


ROOF 1.00 kPa
PANTRY 1.90 kPa BEAM STIRRUPS AND COLUMN TIES 40mm

Sh
KITCHEN 1.90 kPa WHERE CONCRETE IS EXPOSED TO
BALCONY 2ND FLOOR 3.80 kPa
3. CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSISITON WITHOUT SEGREGATION. RE-HANDLING
NOTE:
ALL CONCRETE REINF. DETAIL SHOULD
OR PLACING SHALL BE DONE PREFERABLY WITH BUGGIES , BUCKETS OR WHEELBARROWS, BE DONE IN ACCORDANCE WITH ACI
C. WIND LOAD LOCATION: CAGAYAN DE ORO NO CHUTES WILL BE ALLOWED EXCEPT TO TRANSFER CONCRETE FROM HOPPERS TO BUIGGIES, DETAILING MANUAL (LATEST EDITION)
BUILDING CATEGORY = 1 (ESSENTIAL FACILITIES) WHEELBARROWS OR BUCKETS IN WHICH CASE THEY SHALL NOT EXCEED SIX (6) METERS
IN AGGREGATE LENGTH.
(URBAN OR SUBURBAN AREAS WITH
EXPOSURE CAT B NUMEROUS CLOSELY SPACED OBSTRUCTIONS) 4. NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF VIBRATORS UNLESS
WIND VELOCITY V=150 KPH AUTHORIZED IN WRITING DESIGNER AND ONLY FOR UNUSUAL CONDITIONS WHERE VIBRATIONS
ARE EXTREMELY DIFFICULT TO ACCOMPLISH. TYPICAL COLUMN ELEV. SHOWING
P = qh [(GCpf)-(GCpi)] (DESIGN WIND PRESSURE)
5. ALL ANCHOR BOLTS, DOWELS, AND OTHER INSERTS SHALL BE PROPERLY POSITIONED & SECURED DOWELS AND TIES SPACING
WHERE: qh = VELOCITY PRESSURE (kPa)
IN PLACE PRIOR TO PLACING OF CONCRETE.
GCpf = EXTERNAL PRESSURE COFFECIENT
GCpf = INTERNAL PRESSURE COFFECIENT 6. ALL CONCRETE SHALL BE KEPT MOST FOR A MINIMUM OF SEVEN CONSECUTIVE DAYS IMMEDIATELY
AFTER POURING BY THE USE O WET BURLAP, FOG SPRAYING, CURING COMPOUNDS OR OTHER
D. SEISMIC LOAD APPROVED METHODS. LAP SPLICE LENGTH:
AT ANY LEVEL NO MORE THAN
V =Cvl W (DESIGN BASE SHEAR) 7. STRIPPING OF FORMS AND SHORES:
24 HOURS ALTERNATE BARS SHOULD BE
RT FOUNDATION
SPLICED. MIN. DISTANCE BET.
2.50CaI SUSPENDED SLAB EXCEPT WHEN 8 DAYS

H (CLEAR HEIGHT OF COL.)


Vmax = W Vmin = 0.11 CalW TWO ADJACENT BARS SPLICES
RT ADDITIONAL LOADS ARE IMPOSED SHALL BE 600mm.
Vmin = 0.80 ZNvI W (ZONE 4) BEAMS 14 DAYS
R 21 DAYS L
COLUMNS

WITHIN CENTER
WHERE: W = TOTAL DEAD LOAD

HALF OF "H"
T = NATURAL PERIOD = Ct (h)
WHERE: C = NUMERICAL COEFFICIENT 8. THE CONTRACTOR SHALL SUBMIT THE SCHEDULE OF POURING AND THE LOCATION OF THE 0.25L
h = BUILDING HEIGHT CONSTRUCTION JOINTS TO THE STRUCTURAL ENGINEER AT LEAST (4) DAYS PRIOR TO THE TOP BARS @ SUPPORT (CONT.)
I = IMPORTANCE FACTOR = 1.00 POURING FOR APPROVAL.

CONF. REINF. TIES LAT. TIES


REQ'D. BOTT. BARS @ SUPPORT

JT. REINF.
R = NUMERICAL FACTOR = 8.50 9. THE CONTRACTOR SHALL FURNISH AND MAITAIN ADEQUATE FORMS AND SHORINGS UNTIL THE
SEISMIC COEFFICIENT Cv = 0.44 Nv CONCRETE MEMBERS HAVE ATTAINED THEIR WORKING CONDITION AND STRENGTH.
Ca = 0.64 Nv
NEAR SOURCE FACTOR (5 km) Nv = 1.2
Na = 1.2 NOTES ON FOOTINGS
BOTTOM BARS
Z = SEISMIC ZONE = 0.40 (ZONE 4) 1. FOOTINGS ARE DESIGNED FOR AN ALLOWANCE SOIL BEARING PRESSURE OF 96 KPa (2000psf). 0.165L SPLICE AT MID SPAN
S = SOIL TYPE = D CONTRACTOR SHALL REPORT TO THE ENGINEER, IN WRITING ,THE ACTUAL SOIL CONDITIONS 0.22L EXTRA TOP BARS
UNCOVERED AND CONFIRM ACTUAL BEARING CAPACITY OF SOIL BEFORE DEPOSITING CONCRETE. @ SUPPORT
2.2 DESIGN STRESSES 2. FOOTING SHALL REST AT LEAST 1000mm BELOW NATURAL GRADE LINE UNLESS OTHERWISE
A. CONCRETE COMPRESSIVE STRENGTH @ 28 DAYS: INDICATED IN PLANS. NO FOOTING SHALL REST ON FILL
a. FOOTINGS, COLUMNS, BEAMS AND SLABS f'c = 27.6 MPa (4,000 psi) 3. MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE 75mm CLEAR FOR CONCRETE
b. SLAB ON FILL f'c = 17.5 MPa (2,500 psi) DEPOSITED THE GROUND AND 50mm FOR CONCRETE DEPOSITED AGAINST A FORMWORK. TYP. DETAIL OF COL. LAP SPLICE
& EXT. GIRDER TO COL. CONNECT.
B. REINFORCING STEEL BARS NOTES ON REINFORCEMENT
FOR BARS LESS THAN 16mm 1. UNLESS OTHERWISE NOTED IN PLANS, THE YIELD STRENGTH OF REINFORCING BARS SHALL BE:
(STRUCTURAL GRADE DEFORMED BAR) fy = 275 MPa (40,000 psi) A. FOOTINGS fy = 275 MPa ( 40,000 psi )
C. STRUCTURAL STEEL ASTM-A36 B. COLUMNS fy = 275 MPa ( 40,000 psi )
FOR TRUSSES, BRACINGS , & STRUTS fy = 248 MPa (36,000 psi) C. BEAMS AND GIRDER fy = 275 MPa ( 40,000 psi ) NOTES ON BEAMS AND GIRDERS
D. PURLINS 2. ALL REINFORCING BARS SIZE 10mm OR LARGER SHALL BE DEFORMED IN ACCORDANCE WITH THE ASTM A-706
COLD FORMED LIGHT fy = 248 MPa (36,000 psi) 1. UNLESS, OTHERWISE NOTED IN PLANS , CAMBER ALL BEAMS AND GIRDER AT
E. MASONRY UNIT (CHB) 3. SPLICES SHALL BE SECURELY WIRED TOGETHER & SHALL LAP OR EXTEND IN ACCORDANCE w/ TABLE B
NON - LOADING BEARING CHB WALLS fm' = 3.45 MPa (500 psi) (TABLE OF LAP SPLICE & ANCHORAGE LENGTH) UNLESS OTHERWISE SHOWNON DRAWINGS , SPLICES SHALL BE
F. WELDS E - 60XX ELECTRODE STAGGERED WHENEVER POSSIBLE. BUT IN NO CASE LESS THAN 20 mm FOR EVERY 3.0 M OF FREE SPAN.
G. STRUCTURAL BOLTS ASTM- A307 a. Ft = 96.60 mPa (14, 000 psi)
b. Fv= 69.00 mPa (10, 000 psi) NOTES ON CONCRETE SLABS 2. TYPICAL BARS BENDING AND CUTTING DETAILS FOR BEAMS SHALL BE AS
SHOWN IN FIG. B-1
1. ALL SLAB REINFORCEMENTS SHALL BE 20mm CLEAR MINIMUM FROM BOTTOM AND FROM THE TOP OF SLAB.
3.0 IN THE INTERPRETATION OF THE DRAWING, INDICATED DIMENSIONS SHALL GOVERN. 2. IF SLABS ARE REINFORCED BOTHWAYS BARS ALONG THE SHORTER SPAN SHALL BE PLACED
DISTANCES AND SIZES SHALL NOT BE SCALED FOR CONSTRUCTIONS PURPOSES BELOW THOSE ALONE THE LONG SPAN AT THE CENTER AND OVER THE LONGER SPAN FOR
4.0 IN REFERENCES TO OTHER DRAWINGS, SEE ARCHITECTURAL DRAWINGS FOR DEPRESSIONS IN FLOOR REINFORCING BARS NEAR THE SUPPORTS. THE SPACING OF THE BARS AT THE COLUMN STRIPS L1 L2
SLABS , OPENINGS IN THE WALLS AND SLABS , INTERIOR PARTITIONS , LOCATIONS OF DRAINS ETC. SHALL NOT BE MORE THAN ONE AND A HALF ( 1 1 2 ) SLAB THICKNESS. 1 1 1 1
L1 3 L1 3 L2 3 L2 3
5.0 IN CASE OF DISCREPANCIES AS TO THE LAYOUT, DIMENSIONS AND ELEVATIONS BETWEEN THE
STRUCTURAL PLANS AND ARCHITECTURAL DRAWINGS, THE CONTRACTORS SHALL NOTIFY BOTH THE
STRUCTURAL ENGINEER AND ARCHITECTS.
6.0 ALL CONCRETE WORKS AND CONCRETE REINFORCEMENTS SHALL BE DONE IN ACCORDANCE WITH THE NOTES ON COLUMNS
ACI.318-14M BUILDING CODE REQUIREMENT AND ALL STRUCTURAL STEEL WORKS ACCORDING WITH THE 1. PROVIDE EXTRA SETS OF TIES AT 100 O.C. FOR TIED COLUMN REINFORCEMENT ABOVE 1 1 1 1
L1 5 L1 5 L2 5 L2 5
WITH THE AISC-05 IN SOFAR AS THEY DO NOT CONFLICT WITH THE LOCAL BUILDING CODE REQUIREMENT. AND BELOW BEAM-COLUMN CONNECTIONS FOR A DISTANCE FROM FACE OF CONNECTION TOP BARS
7.0 ACI REFERS TO AMERICAN CONCRETE INSTITUTE, AISC REFERS TO AMERICAN INSTITUTE OF STEEL EQUAL TO GREATER OF THE OVERALL THICKNESS OF COLUMN, 1/6 THE CLEAR HEIGHT OF WEB BARS
BOTTOM BARS
CONSTRUCTION AND ASTM REFERS TO AMERICAN SOCIETY FOR TESTING MATERIALS. COLUMN OR 450mm.
8.0 CONSTURCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR 2. COLUMN TIES SHALL BE PROTECTED EVERYWHERE BY A COVERING OF CONCRETE CAST FIGURE B-1
NOTED. MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS. MONOLITHICALLY WITH THE CORE WITH A MINIMUM THICKNESS OF 40mm AND NOT LESS
THAN 40 TIMES THE MAXIMUM SIZE OF COARSE AGGREGATE IN MILLIMETERS.
9.0 SHOP DRAWING WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEELS, MISCELLANEOUS
IRON, PRE-CAST CONCRETE, ETC. SHALL BE SUBMITTED FOR ENGINEERS APPROVAL BEFORE FABRICATION. 3. WHERE COLUMNS CHANGE IN SIZE ,VERTICAL REINFORCEMENT SHALL BE OFFSET AT A
SLOPE MONOLITHICALLY WITH THE CORE WITH MINIMUM THICKNESS OF 40mm AND
10. CONTRACTOR SHALL NOTE AND PROVIDE ALL MISCELLANEUOS CURBS, SILLS , STOOLS EQUIPMENT AND NOT LESS THAN 40 TIMES THE MAXIMUM SIZE COARSE AGGREGATE IN MILLIMETERS.
MECHANICAL BASES THAT ARE REQUIRED BY THE ARCHITECTURAL , ELECTRICAL AND MECHANICAL DRAWINGS.
4. UNLESS OTHERWISE INDICATED IN THE PLANS, LAP SPLICES FOR VERTICAL COLUMN
11. ALL RESULTS OF THE MATERIAL TESTING FOR CONCRETE, REINFORCING BARS & STRUCTURAL STEEL MUST REINFORCEMENT SHALL BE MADE WITHIN THE CENTER HALF OF COLUMN HEIGHT, AND
BE NOTED & APPROVED BY THE MATERIALS ENGINEER/STRUCTURAL DESIGNER. THE SPLICE LENGTH SHALL BE LESS THAN 40 BAR DIAMETERS. WELDING OR APPROVED
MECHANICAL DEVICES MAY BE USED PROVIDED THAT NOT MORE THAN ALTERNATE BARS
ARE WELDED OR MECHANICALLY SPLICED AT ANY LEVEL AND THE VERTICAL DISTANCES
BETWEEN THESE WELDS OR SPLICES OF ADJACENT BARS IS NOT LESS THAN 600mm.

CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 2-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
S
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
1 6
TABLE 'A' TABLE 'B'
TENSION BARS COMPRESSION BARS
TABLE OF LAP SPLICE & ANCHORAGE LENGTH (mm) TABLE OF LAP SPLICE & ANCHORAGE LENGTH (mm) 0.10 OFFICE OF THE BUILDING OFFICIAL
BAR SIZES fc`= 20.7MPa(3000psi) fc`= 27.6 MPa (4000psi) BAR SIZES fc`= 20.7MPa(3000psi) fc`= 27.6 MPa (4000psi)
(DEFORMED MM) (DEFORMED MM)
EMBEDMENT LAPPED EMBEDMENT LAPPED EMBEDMENT LAPPED EMBEDMENT LAPPED
10 300 300 300 300 10 225 300 200 300

16 300 300 300 300 16 275 300 250 300

NOTES:
NOTES: 1. TOP PLAIN BARS, MULTIPLY VALUE BY 2
1. TOP PLAIN BARS, MULTIPLY VALUE BY 2
2. NOT MORE THAN 33% OF THE BARS SHALL BE
2. NOT MORE THAN 33% OF THE BARS SHALL BE 2"
SPLICED WITHIN THE REQUIRED LAP LENGTH
SPLICED WITHIN THE REQUIRED LAP LENGTH
3. VALUES GIVEN ABOVE CAN ALSO BE USED FOR COLUMNS
0.10

3. IF THE BEAM REINFORCING BARS END IN A WALL, THE CLEAR DISTANCE FROM THE BAR TO THE FARTHER FACE OF THE NOTES ON STRUCTURAL STEEL
WALL IS NOT LESS THAN 25mm. EMBEDMENT LENGTH SHALL BE SHOWN IN A TABLE 'A' FOR TENSION BARS AND TABLE 'B' 1. STRUCTURAL STEEL TO BE USED FOR FABRICATION AND ERECTION OF THIS
FOR COMPRESSION BARS UNLESS UNLESS SPECIFIED IN PLAN. TOP BARS AND SHALL NOT BE SPLICED WITHIN THE STRUCTURE SHALL COMPLY WITH ALL THE PERTINENT PROVISION OF AISC
COLUMN OR TWO STIRRUPS SHALL BE PROVED AT ALL SPLICES. SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL
4. WHEN A BEAM CROSSES A GIRDER , REST BEAM ON TOP OF GIRDER BARS, BEAM REINFORCING BARS SHALL BE STEEL FOR BUILDING LATEST EDITION.
0.40
SYMMETRICAL ABOUT THE CENTER LINE WHENEVER POSSIBLE. 2. ALL STRUCTURAL STEEL SHAPES SHALL CONFORM TO ASTM A36 STRUCTURAL VARIES
5. GENERALLY, NO SPLICES SHALL BE PERMITTED AT POINTS WHERE CRITICAL BENDING STRESSES OCCUR, SPLICES STEEL UNLESS OTHERWISE INDICATED.
WHERE SO PERMITTED SHALL BE INDICATED IN TABLE 'A' AND 'B'. WELDED SPLICES SHALL DEVELOP IN TENSION AT 3. ALL WELDED CONNECTIONS SHALL DEVELOP THE FULL STRENGTH OF THE
LEAST 125% OF THE SPLICED YIELD STRENGTH OF THE BAR NOT MORE THAN 50% OF THE BARS AT ANY ONE SECTION MEMBERS CONNECTED.
IS ALLOWED TO BE SPLICED THEREIN. 4. UNLESS OTHERWISE SPECIFIED ALL WELDING RODS SHALL CONFORM WITH
E60 ELECTRODES.
5. ALL BOLTS USED UNLESS OTHERWISE SPECIFIED SHALL BE ASTM A 307 BOLTS.
NOTES ON CONCRETE HOLLOW BLOCKS WALLS 0.10m THK. GRAVEL/BOULDERS
BASE COURSE 0.20
NOTES ON CONSTRUCTION JOINTS IN CONCRETE COMPACTED TO 98%
1. UNLESS OTHERWISE SHOWN IN PLANS ALL CONCRETE HOLLOW BLOCKS AND CERAMIC BLOCKS SHALL BE REINFORCED
AS SHOWN IN THE SCHEDULE OF CONCRETE HOLLOW BLOCKS AND CERAMIC BLOCK REINFORCEMENT. 1. WHERE A CONSTRUCTION JOINT IS TO BE MADE, THE SURFACE OF CONCRETE MDD BASE ON ASTM
SHALL BE CLEANED AND ALL LAITANCE AND STANDING WATER REMOVED SHEAR 3-10MM Ø LONGITUDINAL BARS
2. PROVIDE 150mm x 300mm STIFFENER COLUMN REINFORCED WITH 4-10mm WITH 10mm TIES @ 150mm ON CENTER D-698
KEY SHALL BE PROVIDE AT THE JOINT. W/ 10MMØ TRANSVERSE BARS
WHERE CONCRETE HOLLOW BLOCK TERMINATES AND AT EVERY 3.0M LENGTH OF CONCRETE HOLLOW BLOCK
WALLS UNLESS NOTED IN STRUCTURAL PLANS. MAIN REINFORCEMENTS TO BE
SPACED @ 0.30M O.C. BOTH WAYS
CONTINUOUS (TOP & BOTT. BARS)
0.40
MAIN REINFORCEMENTS WHERE JOINTS IS AT POINT OF
TO BE CONTINUOUS STRESS, PROVIDE SHEAR RODS
WITH ENGINEERS APPROVAL
NOTES ON CONCRETE HOLLOW BLOCKS WALLS REINFORCEMENTS
BLOCK THICKNESS REINFORCEMENT NOTES 50
(MIN.) (MIN.)
HORIZONTAL LAPPED A. MINIMUM LAPS AT SPLICE= 0.25 M 40

D/3
B. PROVIDE RIGHT ANGLED REINFORCEMENT

D/3
t/3 t/3
AT CORNERS 0.92 m LONG

D
100 mm 10mm EVERY 3RD LAYER 10mm @ 60cm O.C.

t/3

t
C.WHERE CHB OR CER. BLK. WALL DOWELS

D/3
WITH THE SAME SIZE AS VER. OR HOR.
150mm 10mm EVERY 3RD LAYER 10mm @ 60cm O.C. REINFORCEMENT SHALL BE PROVIDED
SLAB

WALL FOOTING DETAILS


BEAM

TYPICAL SLAB & BEAM SCALE: 1:100MTR


TYPICAL CONNECTION DETAIL OF MASONRY WALL CONSTRUCTION JOINT DET.
12 THK. EXPANSION JOINT
WITH MASTIC FILLER
(DOWEL)
400

CHB WALL
FOR SIZE AND SPACING
OF HOR. & VERT. BARS
SEE CONSTRUCTION NOTES.
NOTES ON STIRUPS
FOR SIZE AND SPACING 1. ALL REINFORCEMENT SHALL BE BENT COLD UNLESS
OF HOR. & VERT. BARS
SEE CONSTRUCTION NOTES. OTHERWISE PERMITTED BY THE STRUCTURAL ENGINEER.
CHB WALL 2. AS SHOWN IN THE DESIGN DRAWINGS OR 2" ELEVATE STEEL DECKING
PERMITTED BY THE STRUCTURAL ENGINEER. (INTERIOR FLOOR ONLY)
APPLY WATER PROOFING BEFORE 10mm DRB space @
CORNER WALL OPENING OR END WALL 3. TIES & CLOSE STIRRUPS MUST BE AT 135.
0.20m BW CUT @ L / 4
POURING 2" OF CONCRETE

CHB WALL R.C. COLUMN OR WALL


DOWEL BARS TO MATCH
CHB HOR. BARS
12 THK. EXPANSION JOINT 12 THK. EXPANSION JOINT
WITH MASTIC FILLER WITH MASTIC FILLER
180 DEG. HOOKS
Dbar
(DOWEL)

D+12db
400

FOR SIZE AND SPACING


OF HOR. & VERT. BARS
SEE CONSTRUCTION NOTES. 400
(DOWEL)
4db OR 65mm
INTERSECTION WALL INTERSECTING R.C. COLUMN OR WALL

90 DEG. HOOKS
Dbar 2" DROP STEEL DECKING
NOTES ON WELDS SPACE 2 PCS . AS PER PLAN
1. USE E60xx ELECTRODES FOR ALL MEMBERS WELDED. (EXTERIOR FLOOR ONLY)
L
12db

2. WELDS SHALL DEVELOP THE FULL STRENGTH OF MEMBERS JOINED UNLESS


OTHERWISE SHOWN OR DETAILED IN THE DRAWINGS.
2" DROP STEEL DECKING SPACE 2 PCS . AS PER PLAN
D
STEEL BEAM OR RC BEAM
NOTES ON EMBBED PIPES
1. ALL EMBEDED PIPES FOR UTILITIES ETC. THAT PASS THRU BEAMS SHALL NOT
EXCEED 100mm IN DIAMETER OR 1/3 BEAM DETPH WHICHEVER IS LESS, UNLESS
OTHERWISE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER.
2. NO PIPES SHALL BE ALLOWED TO PASS THRU BEAMS VERTICALLY.
3. NO PIPES SHALL BE EMBEDDED IN COLUMNS. STEEL DECK DETAILS
SCALE: NDTS

CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 2-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
S
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
2 6
1 2 3 4 5 6 1 2 3 4 5 6 OFFICE OF THE BUILDING OFFICIAL
TIE BEAM TIE BEAM
A
0.10M THICK CONC. C1F2 C2F2 C2F2
SLAB. FROM UPPER
GROUND LINE W/
10mmØ TEMP BARS, TIE BEAM TIE BEAM
SPACED @ 0.60M O.C.
TIE BEAM
BOTH WAYS
B3 B3 B3 B3
W1 W1 W1
TIE BEAM
B B1 B1
C1F2 C1F1 C1F1 C1F1 B1

TIE BEAM
B2 B2 B2 B2
TIE BEAM

C
TIE BEAM
C1F1 C1F1 C1F1 C1F1 C1F1 D B1 B1 B1 B1

15

TIE BEAM E 14
13

C2F2 C1F1 C1F1 B1 B1 12


11

TIE BEAM TIE BEAM 10


9
B2 B2 B2 8
B2 7
TIE BEAM 6
5
4
3
C2F2 2
C1F1
C2F2 TIE BEAM
F B1 B1 W1 B1 W1 B1 W2
1

B2 B3
C1F1
B2 B2

C1F2 B1 B1
TIE BEAM

FOUNDATION PLAN
SCALE: 1:100MTR
SECOND FLOOR FRAMING PLAN
SCALE: 1:100MTR

CONCRETE STRENGTH = 3000 PSI @ 28 DAYS


REBARS = GRADE 40 / 276 MPA FOR 12 MM DIA.
AND 16 MM DIA. DRB
= GRADE 33 / 228 MPA FOR 10 MM DIA. DRB
LENGTH (L1) LENGTH (L2) LENGTH (L3)
AT SUPPORT AT MIDSPAN L1 / 3 L1 / 3 L2 / 3 L2 / 3 L2 / 3 L2 / 3 AT SUPPORT AT MIDSPAN
b b b b

min. 1" min. 1"

h h h
4 cm min. 1"

4 cm 4 cm

min. 1"
4 cm
L1 / 5 L1 / 5 L2 / 5 L2 / 5 L3 / 5 L3 / 5
10MM DIA.-STIRRUPS 10MM DIA.-STIRRUPS 10MM DIA.-STIRRUPS
SECTION A SECTION B 5@ 50mm,3 @ 100mm, 5@ 50mm,3 @ 100mm, 5@ 50mm,3 @ 100mm, SECTION C SECTION D
REST @ 200 mm O.C.
REST @ 200 mm O.C. REST @ 200 mm O.C.

TYPICAL BEAM DETAIL


SCALE NDTS

CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 2-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
S
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
3 6
0.20 0.20

3-16mmØ DFB 3-16mmØ DFB OFFICE OF THE BUILDING OFFICIAL

RB RB RB MAIN BARS: 6-16mmØ DFB, 2-20mmØ


STIRRUPS: 1-10mmØ DFB SPACED 1-@0.05,

0.30

0.30
4@0.10m, 4@0.15m, REST @ 0.20M.

RB RB RB
3-16mmØ DFB 3-16mmØ DFB TIE BEAM
SCALE 1:10 MTRS
RB

0.25 0.25

RB RB RB FIN. FLOOR LINE FIN. FLOOR LINE


4-16mmØ DFB 2-16mmØ DFB
MAIN BARS: 6-16mmØ DFB
STIRRUPS: 1-10mmØ DFB SPACED 1-@0.05,

0.40

0.40
4@0.10m, 4@0.15m, REST @ 0.20M.
RB RB RB
RB
2-16mmØ DFB 4-16mmØ DFB BEAM-RB
SCALE 1:10 MTRS

RB RB
RB
0.25 0.25

FIN. FLOOR LINE FIN. FLOOR LINE


4-16mmØ DFB 2-16mmØ DFB
ROOF BEAM PLAN
SCALE: 1:100MTR
MAIN BARS: 6-16mmØ DFB
STIRRUPS: 1-10mmØ DFB SPACED 1-@0.05,

0.40

0.40
4@0.10m, 4@0.15m, REST @ 0.20M.

TO BUILDING
2-16mmØ DFB 4-16mmØ DFB BEAM-B1
SCALE 1:10 MTRS
SKIM COAT FINISHED ON
SEMI SMOOTH PLASTER FINISHED
16mmØ VERTICAL BARS
SEE COLUMN DETAIL
10mmØ LATERAL TIES SPACED
2@0.05, 3@0.10, REST @0.175 0.25 0.25
60X60 TILE FLOOR FINISHED
SEMI SMOOTH PLASTER W/
TEXTURED FINISHED FIN. FLOOR LINE FIN. FLOOR LINE
0.450.10

CONC. FLOORING W/ 10mmØ TEMP. BARS


6-16mmØ DFB 2-16mmØ DFB
0.55

MAIN BARS: 8-16mmØ DFB


STIRRUPS: 1-10mmØ DFB SPACED 1-@0.05,

0.40

0.40
4@0.10m, 4@0.15m, REST @ 0.20M.

2-16mmØ DFB 6-16mmØ DFB BEAM-B2


1.10

SCALE 1:10 MTRS


1.40

0.20 0.20
0.30

SEE FOOTING DETAIL


FIN. FLOOR LINE FIN. FLOOR LINE
4-16mmØ DFB 2-16mmØ DFB
MAIN BARS: 6-16mmØ DFB
STIRRUPS: 1-10mmØ DFB SPACED 1-@0.05,
0.25

0.25
4@0.10m, 4@0.15m, REST @ 0.20M.

2-16mmØ DFB 4-16mmØ DFB BEAM-B3


COLUMN-FOOTING DETAIL
SCALE: 1:100MTR
SCALE 1:10 MTRS

CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 2-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
S
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
4 6
W SCHEDULE OF FOOTING
FOOTING L W T BEDBARS OFFICE OF THE BUILDING OFFICIAL

FOR INSIDE COLUMN


F1
F2

VARIES (REINFORCEMENT)
SEE COLUMN
FIREWALL ONLY
SCHEDULE OF COLUMN
L COLUMN L W
C1
MATTING, SEE TABLE C2

VARIES (REINFORCEMENT)

FOOTING - 1&2
SCALE: 1:30MTR

RAFTER TRUSS

TO BUILDING
USING 2"x4"x1.5mm THK.
SKIM COAT FINISHED ON LONGITUDINAL C-PURLINS
SEMI SMOOTH PLASTER FINISHED SPACED @ 800mm O.C.B.W.
PRE-PAINTED
SEE COLUMN DETAIL

10mmØ LATERAL TIES SPACED


2@0.05, 3@0.10, REST @0.175
60X60 TILE FLOOR FINISHED
ROUGH PLASTER W/
PAINTED, WATER PROOFING
0.450.10

CONC. FLOORING W/ 10mmØ TEMP. BARS


0.55

NGL LINE USING 4mm THICK END


WALL FLASHING
1.10

1.40
0.30

SEE FOOTING DETAIL

RAFTER TRUSS

COLUMN FOOTING
DETAIL FIREWALL AREA ROOF FRAMING PLAN
SCALE: 1:100MTR
SCALE 1:40 MTRS

CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 2-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
S
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
5 6
SCHEDULE OF SLAB:
800mm
50x100x1.5 C-PURLIN @
800mm OC
OFFICE OF THE BUILDING OFFICIAL
50x50x2.5 ANGLE
MID SPAN CONTINUOUS EDGE DISCONTINUOUS EDGE
(BOTTOM LAYER) (TOP LAYER) (TOP LAYER)
10mm Ø @ 0.35 MTRS 10mm Ø @ 0.20 MTRS 10mm Ø @ 0.25 MTRS
1ST FLR
RAFTER )
m cpurlin-rafter MID SPAN CONTINUOUS EDGE DISCONTINUOUS EDGE
L
(50x150x1.5m
(BOTTOM LAYER) (TOP LAYER) (TOP LAYER)
12mm Ø @ 0.30 MTRS 10mm Ø @ 0.25 MTRS 10mm Ø @ 0.20 MTRS

NOTE:
1. PROVIDE 16mmØ SAG RODS @ EVERY 2.0m SPAN MID SPAN CONTINUOUS EDGE DISCONTINUOUS EDGE
with TURN BUCKLE @ TRUSSES
2. SEE SCHEDULE OF PURLIN
(BOTTOM LAYER) (TOP LAYER) (TOP LAYER)
12mm Ø @ 0.16 MTRS 10mm Ø @ 0.15 MTRS 10mm Ø @ 0.19 MTRS
2ND FLR
PURLIN-RAFTER DETAILS MID SPAN CONTINUOUS EDGE DISCONTINUOUS EDGE
SCALE: 1:100MTR
(BOTTOM LAYER) (TOP LAYER) (TOP LAYER)
12mm Ø @ 0.17 MTRS 12mm Ø @ 0.21 MTRS 12mm Ø @ 0.20 MTRS

L/5

10mmØ CHAIR
BARS SPACED @
L/4
0.20M O.C. W/
10MMØ
HORIZONTAL BARS
USING 16mmØ SHORT
DIRECTION BARS
SPACED @ 0.20M O.C.

USING 16mmØ LONG


DIRECTION BARS
SPACED @ 0.20M O.C.
L/5

L/4

Rebar
STAIR REINFORCMENT DETAILS
T (thickness)

SCALE: 1:100MTR
1-1/2 T

2"thk Gravel fill

1-1/2 T
ISOMETRIC VIEW SLAB ON GRADE
Compacted soil

SLAB ON GRADE END DETAIL


SCALE: 1:20MTR

CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 2-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
S
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
6 6
SPECIFICATIONS: OFFICE OF THE BUILDING OFFICIAL

1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE


PROVIDING OF THE BUILDING CODE AND THE RULES AND REGULATIONS. 1/2"Ø COLD WATER
PIPE LINE RISER
1 2 3 4 5 6
2. COORDINATE THE DRAWINGS WITH THE OTHER RELATED DRAWINGS 7 SPECIFICATIONS.
THE ARCHITECT/ ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY.
3. PIPES SHALL BE INSTALLED AS SHOWN ON PLAN, ANY RELOCATION REQUIRED FOR
PROPER EXECUTION OF OTHER TRADES SHALL BE WITH PRIOR APPROVAL OF THE
ARCHITECT OR ENGINEER.
4. PROPOSED SANITARY UTILITIES SHALL CONFORM THE ACTUAL LOCATION DEPTH &
INVERT ELEVATIONS OF THE PIPES & STRUCTURE.
5. ALL SLOPES FOR SEWER HORIZONTAL BRANCHES SHALL MAINTAIN 2% UNLESS
OTHERWISE NOTED.
W1 W1 W1
6. ALL FIXTURES & TRAPS MUST BE PROVIDED WITH INDIVIDUAL/ CIRCUIT VENTS UNLESS
OTHERWISE INDICATED THERE SHALL BE REQUIRED VENTILATION & LIGHTING SYSTEM FOR 1/2"Ø COLD WATER PIPE LINE
TOILET & BATHROOMS.
7. ALL SLEEVES SHALL BE PROVIDED IN ALL WALLS, COLUMNS, OE SLABS GREATER THAN
THE ACTUAL LINES PASSING THROUGH WALLS & UNDER SLABS TO PROTECT PIPES FROM
BREAKAGE.
8. ALL SEWER LINES 7 WASTE PIPES) & VENT PIPING SYSTEMS SHALL BE UNPLASTICISED
POLYVINYL CHLORIDE PIPES (PVC) CONFORMING TO ASST. 2728 OR ISO.
9. ALL WATER DISTRIBUTION LINES (COLD WATER LINES) SHOULD BE UNPLASTICISED POLYVINYL
CHLORIDE PIPES MANUFACTURED ACCORDING TO ISO-R-161. D2
D2 D3
10. STORM DRAINAGE PIPE SHALL BE CONCRETE FOR SIZES cc% ABOVE CONFORMING TO ASTM
76 CLASS II RESPECTIVELY. D3 3"Ø WASTE PIPE LINE
11. ALL PVC PIPES SIZES FOR WATER & SEWER LINES ARE IN NOMINAL OUTSIDE DIAMETER 4"Ø SOIL PIPE RISER D2
(ISO STANDARD). 15
12. ALL EXPOSES AND MAIN WATER SUPPLY LINE SHALL BE G.I. PIPES SCHEDULE 40. 3"Ø WASTE PIPE LINE 14

13. ALL PLUMBING WORKS SHALL BE DONE BY AN EXPERIENCED PLUMBER UNDER THE DIRECT D2
13

SUPERVISION OF A COMPETENT SANITARY ENGINEER. D2 12


11
10
93"Ø WASTE PIPE RISER

D3
8
4"Ø SOIL PIPE RISER 7
D3 6
5
4
3
2
1
W1 W1 W2

SYMBOLS: W1

CO -CLEAN OUT CB -CATCH BASIN


DS -DOWN SPOUT
3"Ø WASTE PIPE RISER
WC -WATER CLOSET
LAV. -LAVATORY
-CHECK VALVE
FD -FLOOR DRAIN
-FOOT BATH COLD WATER PIPE LINE
FB
SOIL PIPE LINE
F -FAUSET

S
VTR
-SHOWER
-VENT TRHU ROOF

-SEPTIC VAULT
WASTE PIPE LINE
DRAINAGE PIPE LINE
SECOND FLOOR
PLUMBING LAYOUT
SV -GATE VALVE
SCALE: 1:80 MTR

CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 3-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
P
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
1 4
SPECIFICATIONS:
* ALL INSTALLATION HEREIN SHALL CONFORM WITH THE RULES & REGULATION
1 2 3 4 5 6
OFFICE OF THE BUILDING OFFICIAL
CATCHMENT TANK
OF THE NATIONAL PLUMBING CODE AND LOCAL ORDINANCES.
* PVC PIPES & FITTING FOR SANITARY PIPE LINES EXCEPT FOR WASTE 7
CORRESPONDING VENT SHERE GALVANIZED MAY BE USED. A
* GALVANIZED IRON PIPES 7 FITTINGS FOR ALL WATER SUPPLY & DISTRUBUTION 3"Ø WASTE PIPE LINE
PIPE SYSTEM THREADED UNITS. D1
* NO PIPES SMALLER THAN S40 GA SHALL BE USED. B
* ALL INSTALLATION HERIN SHALL BE UNDER THE DIRECT SUPERVISION OF A
DULY LICENSED SANITARY ENGINEER OR MASTER PLUMBER.
1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE
PROVIDING OF THE BUILDING CODE AND THE RULES AND REGULATIONS.
2. COORDINATE THE DRAWINGS WITH THE OTHER RELATED DRAWINGS 7 SPECIFICATIONS.
THE ARCHITECT/ ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY.
3. PIPES SHALL BE INSTALLED AS SHOWN ON PLAN, ANY RELOCATION REQUIRED FOR
PROPER EXECUTION OF OTHER TRADES SHALL BE WITH PRIOR APPROVAL OF THE
ARCHITECT OR ENGINEER.

LINE
4. PROPOSED SANITARY UTILITIES SHALL CONFORM THE ACTUAL LOCATION DEPTH &
INVERT ELEVATIONS OF THE PIPES & STRUCTURE. C

WASTE PIPE
5. ALL SLOPES FOR SEWER HORIZONTAL BRANCHES SHALL MAINTAIN 2% UNLESS
OTHERWISE NOTED.
6. ALL FIXTURES & TRAPS MUST BE PROVIDED WITH INDIVIDUAL/ CIRCUIT VENTS UNLESS
OTHERWISE INDICATED THERE SHALL BE REQUIRED VENTILATION & LIGHTING SYSTEM FOR D

3"Ø
TOILET & BATHROOMS.
7. ALL SLEEVES SHALL BE PROVIDED IN ALL WALLS, COLUMNS, OE SLABS GREATER THAN
THE ACTUAL LINES PASSING THROUGH WALLS & UNDER SLABS TO PROTECT PIPES FROM
BREAKAGE.
8. ALL SEWER LINES 7 WASTE PIPES) & VENT PIPING SYSTEMS SHALL BE UNPLASTICISED

PIPE LINE
POLYVINYL CHLORIDE PIPES (PVC) CONFORMING TO ASST. 2728 OR ISO.
9. ALL WATER DISTRIBUTION LINES (COLD WATER LINES) SHOULD BE UNPLASTICISED POLYVINYL
CHLORIDE PIPES MANUFACTURED ACCORDING TO ISO-R-161.
10. STORM DRAINAGE PIPE SHALL BE CONCRETE FOR SIZES cc% ABOVE CONFORMING TO ASTM
76 CLASS II RESPECTIVELY.

PIPE LINE
E

SOIL
11. ALL PVC PIPES SIZES FOR WATER & SEWER LINES ARE IN NOMINAL OUTSIDE DIAMETER

LINE
(ISO STANDARD).

4"Ø
12. ALL EXPOSES AND MAIN WATER SUPPLY LINE SHALL BE G.I. PIPES SCHEDULE 40.

WASTE PIPE
13. ALL PLUMBING WORKS SHALL BE DONE BY AN EXPERIENCED PLUMBER UNDER THE DIRECT
SUPERVISION OF A COMPETENT SANITARY ENGINEER.

SOIL
F
1/2"Ø COLD WATER PIPE LINE

3"Ø
4"Ø
4"Ø SOIL PIPE LINE

SYMBOLS: 3"Ø WASTE PIPE LINE 3"Ø WASTE PIPE LINE

CO -CLEAN OUT CB -CATCH BASIN


DS -DOWN SPOUT

WC -WATER CLOSET
LAV. -LAVATORY TO MAIN WATER
-CHECK VALVE
FD -FLOOR DRAIN SOURCE
-FOOT BATH COLD WATER PIPE LINE
FB
SOIL PIPE LINE
F -FAUSET
WASTE PIPE LINE
S -SHOWER
VTR -VENT TRHU ROOF DRAINAGE PIPE LINE

SV -SEPTIC VAULT -GATE VALVE


GROUND FLOOR
PLUMBING LAYOUT
SCALE: 1:80 MTR

CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 3-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
P
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
2 4
0.10 0.30 0.10

SYMBOLS:

0.10
OFFICE OF THE BUILDING OFFICIAL

CO -CLEAN OUT
-DOWN SPOUT

0.50
0.30
DS
WC -WATER CLOSET
LAV. -LAVATORY

0.10
FD -FLOOR DRAIN

FB -FOOT BATH

F -FAUSET
PVC DRAIN PIPE
S -SHOWER

0.10
VTR -VENT TRHU ROOF

SV -SEPTIC VAULT
2% SLOPE
FLOOR DRAIN
0.50
0.30
CB -CATCH BASIN

2"Ø PVC PIPE DETAIL


SCALE NDTS
0.10

-CHECK VALVE GRAVEL


3.70
COLD WATER PIPE LINE
SOIL PIPE LINE
0.10 1.90 0.10 0.70 0.10 0.70 0.10

CATCH BASIN DETAIL


IN LET
WASTE PIPE LINE

0.10
DRAINAGE PIPE LINE SCALE 1:10 MTRS
0.60mX 0.60m MANHOLE
C.O.
-GATE VALVE

THIS SITE

1.30
1.10
0.60mX 0.60m 0.60mX 0.60m
MANHOLE MANHOLE

C.O. C.O. OUTLET

0.10
@ 0.20m OC BOTH WAYS @ 0.10m OC BOTH WAYS

C.O. C.O.
0.60mX 0.60m MANHOLE 0.60mX 0.60m MANHOLE 0.60mX 0.60m MANHOLE C.O.

0.300.10
IN LET 0.30m AIR SPACE

C:\Users\Carlo Flores\Desktop\map2.jpg OUTLET


GRAVEL
1.50

GRAVEL SANITARY WYE


1.00

SAND
CHARCOAL VIRT. BARS SP @ 0.40m OC
HOR. BARS SP @ EVERY 3
GRAVEL
GRAVEL LAYERS OF CHB.
DIGESTIVE CHAMBER LEACHING
0.10

LOCATION MAP SEPTIC VAULT DETAIL


CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 3-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
P
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
3 4
6
SPECIFICATIONS: 5
* ALL INSTALLATION HEREIN SHALL CONFORM WITH THE RULES & REGULATION
OF THE NATIONAL PLUMBING CODE AND LOCAL ORDINANCES.
4 OFFICE OF THE BUILDING OFFICIAL

* PVC PIPES & FITTING FOR SANITARY PIPE LINES EXCEPT FOR WASTE 7
CORRESPONDING VENT SHERE GALVANIZED MAY BE USED.
* GALVANIZED IRON PIPES 7 FITTINGS FOR ALL WATER SUPPLY & DISTRUBUTION R
SE
PIPE SYSTEM THREADED UNITS.
* NO PIPES SMALLER THAN S40 GA SHALL BE USED.
3 W1
IP
E
RI
D2 15
14 T EP
NE 13
AS
* ALL INSTALLATION HERIN SHALL BE UNDER THE DIRECT SUPERVISION OF A E
LI 12
11 ØW
W1 IP 10
9 3"
DULY LICENSED SANITARY ENGINEER OR MASTER PLUMBER.
1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE
2 E 3"
Ø WA
ST
EP

EPI
PE
LI
NE 8
7
6
5
IN ST 4
3
WA
PROVIDING OF THE BUILDING CODE AND THE RULES AND REGULATIONS. EL 2

1
Ø
PIP 3" 1
R D3
2. COORDINATE THE DRAWINGS WITH THE OTHER RELATED DRAWINGS 7 SPECIFICATIONS. W1 AT
E
D2
W D2 W2
THE ARCHITECT/ ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY. LD
R CO D2
3. PIPES SHALL BE INSTALLED AS SHOWN ON PLAN, ANY RELOCATION REQUIRED FOR TE "Ø
WA ER 1/2
LD RIS D3
PROPER EXECUTION OF OTHER TRADES SHALL BE WITH PRIOR APPROVAL OF THE COINE W1
" Ø L
ARCHITECT OR ENGINEER. 1/2PIPE
4. PROPOSED SANITARY UTILITIES SHALL CONFORM THE ACTUAL LOCATION DEPTH & D3 D2
W1
INVERT ELEVATIONS OF THE PIPES & STRUCTURE.
5. ALL SLOPES FOR SEWER HORIZONTAL BRANCHES SHALL MAINTAIN 2% UNLESS
OTHERWISE NOTED. D3

6. ALL FIXTURES & TRAPS MUST BE PROVIDED WITH INDIVIDUAL/ CIRCUIT VENTS UNLESS E R
OTHERWISE INDICATED THERE SHALL BE REQUIRED VENTILATION & LIGHTING SYSTEM FOR R IS
W1
TOILET & BATHROOMS. PE
IL
PI
7. ALL SLEEVES SHALL BE PROVIDED IN ALL WALLS, COLUMNS, OE SLABS GREATER THAN SO
R
Ø SE
THE ACTUAL LINES PASSING THROUGH WALLS & UNDER SLABS TO PROTECT PIPES FROM 4" RI
E
BREAKAGE. IP
I LP
8. ALL SEWER LINES 7 WASTE PIPES) & VENT PIPING SYSTEMS SHALL BE UNPLASTICISED SO
4"
Ø
POLYVINYL CHLORIDE PIPES (PVC) CONFORMING TO ASST. 2728 OR ISO. K S ER
9. ALL WATER DISTRIBUTION LINES (COLD WATER LINES) SHOULD BE UNPLASTICISED POLYVINYL AN RI
TT E
CHLORIDE PIPES MANUFACTURED ACCORDING TO ISO-R-161.
HM TE P
EN IP A
10. STORM DRAINAGE PIPE SHALL BE CONCRETE FOR SIZES cc% ABOVE CONFORMING TO ASTM 6 TC AS
CAØ W
B
76 CLASS II RESPECTIVELY. 3"
11. ALL PVC PIPES SIZES FOR WATER & SEWER LINES ARE IN NOMINAL OUTSIDE DIAMETER
(ISO STANDARD).
5
12. ALL EXPOSES AND MAIN WATER SUPPLY LINE SHALL BE G.I. PIPES SCHEDULE 40. D1 C
13. ALL PLUMBING WORKS SHALL BE DONE BY AN EXPERIENCED PLUMBER UNDER THE DIRECT 4 NE
LI D
SUPERVISION OF A COMPETENT SANITARY ENGINEER. LI
NE PE
EPI
E ST

3 WA
ST
EPI
P WA
3"
Ø

2 3"
Ø
E
1
NE
LI
E
F
IP EP
ST
WA

SYMBOLS:
Ø
3"

E N
LI
CO -CLEAN OUT CB -CATCH BASIN PE
IL
PI
DS -DOWN SPOUT O
ØS
4"
-WATER CLOSET NE
WC NE PE
LI
LI EPI
LAV. -LAVATORY
-CHECK VALVE
PE
PI Ø WA
ST

L NE 3"
FD -FLOOR DRAIN OI S LI
PE NE
Ø
4" LI
COLD WATER PIPE LINE PI E
FB -FOOT BATH E
OI
L IP
LIN TEP
IPE ØS WA
S
SOIL PIPE LINE 4" Ø R
TE
P
F -FAUSET ER 3"
WA
AT
WASTE PIPE LINE
W
LD IN

ISOMETRIC VIEW
S -SHOWER CO
MA CE
TOSOUR
Ø "
VTR -VENT TRHU ROOF DRAINAGE PIPE LINE 1/2

SV -SEPTIC VAULT -GATE VALVE


PLUMBING LAYOUT
SCALE: 1:100 MTR

CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 3-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
P
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
4 4
ELECTRICAL NOTES
A OFFICE OF THE BUILDING OFFICIAL
C1
B
C4

D2

C2 PB1
C

D2
D
C3

D3
E
GROUND FLOOR
ELECTRICAL PLAN (PANEL BOARD-1)
SCALE: 1:100MTR

C1 A
D1

PB2
B

D
SYMBOLS: AIR CONDITION UNIT
RANGE

CIRCUIT LINE 4" LIGHTING OUTLET

CONVENIENCE LINE 3" LIGHTING OUTLET


CONVENIENCE OUTLET
WALL LAMP E
METER
SPIRAL/ CENTER LIGHT
PANEL BOARD
SECOND FLOOR
ELECTRICAL PLAN (PANEL BOARD-2) F
SCALE: 1:100MTR

CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 3-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
E
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
1 2
LOADS & COMPUTATION PANEL BOARD-1 2# 22 THHN 25mmØ EMT PIPE

# POLE OFFICE OF THE BUILDING OFFICIAL


C1 14 6.363 2 2# mm² THHN,20mmØ UPVC PIPE
6.818 2# 14 THHN 2 mmØ EMT PIPE
C2 15 2 2# mm² THHN,20mmØ UPVC PIPE
AT-2P,220V 2# mm² THHN,20mmØ UPVC PIPE
C3
C4
C5 SPARE
7
8
1/2HP
5.727
6.545
5.00
2
2
2
AT-2P,220V2# .5mm² THHN,20mmØ UPVC PIPE
0AT-2P,220V 2# .5mm² THHN,20mmØ UPVC PIPE
PB1 2#
PIPE
THHN 25mmØ EMT
PB2 2#
PIPE
THHN 2 mmØ EMT

C6 SPARE 1/2HP 5.00 2 30AT-2P,220V 2# .5mm² THHN,20mmØ UPVC PIPE


C7 SPARE 1/2HP 5.00 2 0AT-2P,220V 2#5.5mm² THHN,20mmØ UPVC PIPE
C8 SPARE 1/2HP 5.00 0AT-2P,220V 2# .5mm² THHN,20mmØ UPVC PIPE
0A-2P 0A-2P
2
C9 SPARE 1/2HP 5.00 2 0AT-2P,220V 2# .5mm² THHN,20mmØ UPVC PIPE
C10 SPARE 1/2HP 5.00 2 0AT-2P,220V 2# .5mm² THHN,20mmØ UPVC PIPE
TOTAL 29 15 6 55.453 100AT-2P

SIZE OF MAIN CONDUCTOR

I L = 55.453 + 15.00 x 0.25 = 59.203 AMPS. USE 2#14mm² THHN, 20mØ EMT PIPE
FOR MAIN DISCONNECT
I S = 55.453 + 15.00 x 2.25 = 89.203 AMPS. USE 100AT-2P,220V CIRCUIT BREAKER MAIN G.E. BOLT-ON

LOADS & COMPUTATION PANEL BOARD-2

# POLE

SINGLE LINE
C1 9 4.090 2 2# mm² THHN,20mmØ UPVC PIPE
SPARE
SPARE
5.00
5.00
2
2
20AT-2P,220V 2# .5mm² THHN,20mmØ UPVC PIPE
0AT-2P,220V 2# .5mm² THHN,20mmØ UPVC PIPE SINGLE LINE
SPARE

TOTAL 9
5.00

19.090
2 0AT-2P,220V 2# .5mm² THHN,20mmØ UPVC PIPE
60AT-2P DIAGRAM
SCALE NDTS
DIAGRAM
SIZE OF MAIN CONDUCTOR SCALE NDTS
I L = 19.090 + 12.00 x 0.25 = 21.636 AMPS. USE 2#14mm² THHN, 20mØ EMT PIPE
FOR MAIN DISCONNECT
I S = 19.090 + 12.00 x 2.25 = 45.636 AMPS. USE 70AT-2P,220V CIRCUIT BREAKER MAIN G.E. BOLT-ON

GRAND TOTAL LOADS


# POLE
· ODOR - REMOVING FUNCTION
PB1 29 15 6 220V 55.453 2 AT-2P,220V
PB2 8 220V 18.636 2 0AT-2P,220V · SOFT DRY OPERATION MODE
TOTAL 37 15 6 125 AT-2P
· 24 HR ON/OFF REAL SETTING TIMER
ROOF
· BLUE FINS (BLUE COATED CONDENSER)
· INVERTER 8.0
PBOARD-1 · RANDOM AUTO RESTART
D
AR
BO
2ND FLOOR S EL
AM
P AN
30 TOP
SERVICE ENTRANCE PBOARD-2

GUTTER
GROUND FLOOR

AIR CONDITION
RISER DIAGRAM
SCALE NDTS
ISOMETRIC VIEW
CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 3-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
E
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
2 2
NOTES:
1. CONDUIT SHALL BE PERMANENTLY AND EFFECTIVELY GROUNDED OFFICE OF THE BUILDING OFFICIAL
2. THIS ARRANGEMENT LIMITED TO DROP WIRE ATTACHMENT
OF UP TO 5-LINES SPAN TO FIXTURE SHALL NOT EXCEED 45.7M
3. SERVICE MAST SHALL BE SUFFICIENTLY HIGH TO PROVIDE
LEGEND CABLE TV
TELEPHONE
PROPER DROP WIRE CLEARANCE OVER SIDEWALK, TC TERMINAL CABINET TELEPHONE OUTLET DATA/ INTERNET
STREETS, OR ROADWAYS IN COMPLIANCE WITH CODES & REGULATIONS. TELEPHONE
DATA
TELEPHONE LINE
PC PROTECTOR CABINET TAPS SPLITTER

GENERAL TELEPHONE
NUMBER OF CABLES TELEPHONE PORT
TEL

CABLE TELEPHONE 3-WAY SPLITTER

CEILING LINE

1 0.15 0.70 1.0


GENERAL NOTES SERVICE PROVIDER
TEL-2

2ND FLOOR

1. ALL ELECTRONICS INSTALLATION SHALL BE IN


TEL
ACCORDANCE WITH THE LATEST PROVISION OF THE TEL HUB
TEL-1

GROUND FLOOR
PHILIPPINE ELECTRONIC'S CODE
2. DO NOT COMBINED ALL ELECTRONICS OUTLET TO
ELECTRICAL OUTLET. PROTECTOR
3. ALL ELECTRONICS INSTALLATION SHALL BE UNDER THE
CABINET
DIRECT SUPERVISION OF A DULY LICENSED PROFESSIONAL
ELECTRONIC ENGINEER.

THIS SITE 4. ALL ELECTRONICS PLAN SHALL BE SIGN AND SEALED BY


PROFESSIONAL ELECTRONICS ENGINEER UNDER R.A. 9292.
TEL. SINGLE
LINE DIAGRAM

CEILING LINE

CEILING LINE
DATA-2

SERVICE PROVIDER 2ND FLOOR

2ND FLOOR

TAPS MODEM
SERVICE PROVIDER
DATA-1
SPLITTER HUB GROUND FLOOR CAM1 CAM2 CAM3 CAM4
DVR
DATA

GROUND FLOOR
PROTECTOR
CABINET
PROTECTOR

DATA/ENTERNET SINGLE CABINET

LINE DIAGRAM CCTV RISER


LOCATION MAP
CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 3-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
ECE
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
1 2
OFFICE OF THE BUILDING OFFICIAL

A
D1
W1 W1 W1
B

DATA DATA DATA


D3

D3
D2
D2 D2
D3 C

D2
D
D3

DATA DATA
D3

D2

DATA

W1 W1 W2
E
W1

SECOND FLOOR GROUND FLOOR


ELECTRONICS LAYOUT PLAN
ELECTRONICS LAYOUT PLAN
SCALE: 1:80 MTR SCALE: 1:80 MTR

CERTIFIED BY: PRC NO. D R Y S E A L APPROVED BY: CAD BY: CF REVISIONS : SHEET CONTENTS :

PTR NO. PROPOSED 3-STOREY RESIDENTIAL BUILDING


WITH ROOF DECK AND RETAILER
CHECKED BY:
DESIGNED BY:
1.
2.
ECE
DATE ISSUED. DATE START 3.

TIN. NO.
LOCATION OF CONSTRUCTION:

OWNER'S SIGNATURE
OWNER
DATE FINISHED
REFERENCE:
4.
2 2