2 - OPERATION
See fig. 5.
When the hydraulic power unit is switched on, the solenoid valve
EV1 (NO) closes and the motor M starts simultaneously. This
motor drives the gear pump P1 which gives the oil pressure al-
lowing the hydraulic calipers to open.
The opening of the pressure switch CP1, included in the working
circuit, stops the motor M when working pressure reaches the
maximum set level. Then, the installation stays under pressure
with the motor M stopped. If pressure lowers down to the minimum
level, the switch closes and starts the pump motor M again.
1-2 General characteristics
b) Closing of the calipers and braking
The CE8L hydraulic power unit is fitted with a gear pump and a
motor of 2,2 kW at 1500 rpm for a nominal flow rate of 8,4 l/mn
Switching off the motor M and the solenoid valve EV1 brings
(on network 50 Hz).
the oil back to the power unit reservoir and the pressure back to
The maximal utilization pressure is 225 bar. zero. Calipers close and braking torque is applied.
Frequency of operations = 100 operations / hour maximum
c) Manual opening of the calipers
The caliper can be installed horizontally (CE8L-H) or vertically
(CE8L-V) (reservoir at the bottom). With the flow limiter LD1 closed, the hand pump P2 provides
See flow diagram fig.5 and description fig.6. the necessary pressure to open the calipers, in case of mains
failure or manual operations on the calipers.
Calipers are closed by means of a single solenoid valve EV1
(NO). For installations requiring a high level of safety, we advise
the option OP1 (2 EV).
In additional, we recommend a device of permanent diagnosis
of the solenoid valves operation (CS2EV) which allows the
detection of a possible fault .
2-3 Options
OP1 Enhanced security return circuit by 2 solenoid valves. Noncumulable options with option Y5.
Monitoring device of the 2 solenoid valves EV1 and EV2, For CE8L-OP1, CE8L-OP1-OP2, and
CS2EV
consult us. CE8L-OP1-OP3.
The hydraulic unit is fitted with a proportional pressure limit valve This option requires a specific electrical
for a regulated braking or the lowering of the load. unit according to the control system
Y5
(lowering of the load, constant deceleration,
The function of braking on/off is kept. etc..), consult us (APS).
3 - CHARACTERISTICS
3-1 Designation
Unit type
Position
H : horizontal
V : vertical
Options
Example:
b) Calipers (table 2)
SH15 - X
Caliper type
Example: SH15-3
Table 2
Limit switch
Power Calipers types Main limit Hand pump
CP1
unit valve limit valve
type LP LP1
SH25 SH18 SH18B SH15 SH9 SH6 SH5 TH9 SHM10 mini/maxi
CE8L - 20 SH25-2 SH18-2 SH18B -- SH9-3 -- SH5-6 -- -- 225 180 / 200 250
CE8L - 18 -- -- -- SH15-3 SH9-2 SH6-3 -- -- -- 205 150 / 180 230
CE8L - 16 SH25-1 -- -- SH15-2 -- -- SH5-5 TH9-3 -- 205 140 / 160 230
CE8L - 14 -- SH18-1 -- SH15-1 SH9-1 SH6-2 SH5-4 -- -- 165 110 / 140 180
CE8L - 11 -- SH18-0 -- -- -- SH6-1 SH5-3 TH9-2 -- 140 85 / 115 160
CE8L - 07 -- -- -- -- -- -- -- -- SHM10 90 55 / 75 100
The maximum number of calipers associated with the CE8L hydraulic unit is in the leaflet "Connection of a hydraulic unit" quoted
below.
Example: calipers SH15-3 are related to the supply unit CE8L-18.
All the values LP, LP1 and CP1 are pressures given in bar.
Non contractual photographs.
Instructions of this manual must be adhered to, to obtain the performance and the safety of operation of the equipment.
Installation and maintenance Leaflet No. M08555-01 Oils Leaflet No. G08615-02 17/10/11 5/10
Options No. A08555-01 Connection of a hydraulic unit No. G08555-01
Spare parts No. S09580-01 T05570-01-C
SIME Brakes safety in motion
a) Motor M
Table 3
3 phase: 230/400 VAC 50 Hz
2.2 kW, 4 poles Mains 3 phases Motor ∆/Y
Protection IP 55 class F Frequency 50 Hz
Aluminium body, metallic terminal box, brass cable gland
230/400VAC 50Hz ∆ STD
Other 3 phase voltage on option MS : 220-230-240VAC ±10% 50Hz
230/400VAC 50Hz ∆ + PTC MS
290/500VAC 50Hz
230/400VAC 50Hz with PTC sensor 230/400VAC 50Hz Y STD
380-400-415VAC ±10% 50Hz
To specify according to table 3. 230/400VAC 50Hz Y + PTC MS
440VAC ±10% 50Hz 255/440VAC 50Hz Y APS
Fig. 2 Fig. 3
3 phase Single phase 3 phase
mains + T supply mains + T
1 2 3 7 8 1 2 3
Q1 Q1
F1 F2
F1 Q1 T1
0V 230V
13 13
Braking /
KF Braking / release control 0V
KF
Q1 Q1 release control
14 Q1
14
I> I> I>
I> I> I>
9 11
9 EV1 11
KM1
P KM1
B1 x1
EV1 P
B1 x1
H1 H1
10 12 10 12
KM1 KM1
4 5 6
4 5 6
Motor M Motor M
Fig.4 - Dimensions
830
478
40
4 holes Ø9
332
Caliper Caliper
1G
1Q
Power unit
CP1
PP LD1
CA4
CA1
EV1
LP1
CA3 CA5
BR1
M P1
CR
R
BV
Components:
Fig. 6 - Components of the hydraulic unit CE8L standard (shown in horizontal version)
Manometer 1G
Isolation cock 1Q
High level
sight glass
Low level
sight glass Filling port BR1 (breather
replaced by a tight plug for
option OP6)
Reservoir R Motor M
Filter F
LP
Pressure port PP