You are on page 1of 2

Single Aisle TECHNICAL TRAINING MANUAL

FUEL RETURN VALVE D/O (3)


OPERATION (continued)
HIGH RETURN FF OPERATION (1100 KG/H, 2200LB/H)
When the engine oil temperature has reached 95°C, the ECU sends
an electrical opening signal to the solenoid valves V1 and V2. Pressure
supply line maintains the shut-off valve open, and the pilot valve is
opened.
The flow control valve opens, completing the return fuel flow circuit.
The compensating valve will move to keep the return fuel flow
constant.
SHUT-OFF SYSTEM OPERATION
During engine shutdown the ECU de-energizes the V1 and V2
solenoids. The FRV shut-off valve is pushed in the closed position
by the pressure from the LP pump. The FRV shut-off valve switches
transmit the closed position to the ECU.
U7Z08431 - U2XT1T0 - UM73D2CFM000001

T1 (CFM 56) (Lvl 2&3) FUEL RETURN VALVE D/O (3) Oct 24, 2008
70 - POWER PLANT CFM 56 Page 106
Single Aisle TECHNICAL TRAINING MANUAL
U7Z08431 - U2XT1T0 - UM73D2CFM000001

OPERATION - HIGH RETURN FF OPERATION (1100 KG/H, 2200LB/H) & SHUT-OFF SYSTEM OPERATION

T1 (CFM 56) (Lvl 2&3) FUEL RETURN VALVE D/O (3) Oct 24, 2008
70 - POWER PLANT CFM 56 Page 107