Single Aisle TECHNICAL TRAINING MANUAL

START FAILURES (ME) (3)


HIGH PRESSURE FUEL VALVE NOT OPEN IN MANUAL
MODE
If the HP fuel valve does not open, an aural warning sounds, the MASTER
CAUTion and the engine FAULT lights come on and an ECAM message
appears.
The FADEC has detected an HP fuel valve failure and the operator has
to manually abort the sequence following the next steps:
- first release the MANual START P/B and then set the MASTER control
switch to off,
- and finally set the mode selector to the MODE NORMal position.
U7Z08431 - U2XT1T0 - UM74D2CFM000001

T1 (CFM 56) (Lvl 2&3) START FAILURES (ME) (3) Oct 24, 2008
70 - POWER PLANT CFM 56 Page 150
Single Aisle TECHNICAL TRAINING MANUAL
U7Z08431 - U2XT1T0 - UM74D2CFM000001

HIGH PRESSURE FUEL VALVE NOT OPEN IN MANUAL MODE

T1 (CFM 56) (Lvl 2&3) START FAILURES (ME) (3) Oct 24, 2008
70 - POWER PLANT CFM 56 Page 151