Single Aisle TECHNICAL TRAINING MANUAL

START FAILURES (ME) (3)


IGNITION FAULT IN AUTOMATIC MODE
In this failure case the ECU will automatically do 2 start attempts:
- 1 normal start,
- 1 additional attempt.
FIRST ATTEMPT
Select MODE selector to IGNition/START and ENGine MASTER
control switch to ON.
The engine rotates, one ignitor is automatically turned ON at 16 % of
N2 and fuel is automatically supplied at 22 % of N2.
If engine light-up is not obtained within 15 seconds, the FADEC
automatically turns the ignition and the fuel OFF and dry cranks the
engine for 30 seconds before initiating automatically a new start. An
aural warning sounds, the MASTER CAUTion light comes on and
an ECAM message appears.