0% found this document useful (0 votes)
522 views2 pages

EMCD Maintenance for CFM56 Engines

The document discusses checking the master chip detector on a CFM56 engine. It describes how to check if the detector is contaminated by looking for an extended red indicator and how to reset it. It provides steps to remove and check the detector probe for contamination and clean or replace parts as needed.

Uploaded by

Pédro GONZALEZ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
522 views2 pages

EMCD Maintenance for CFM56 Engines

The document discusses checking the master chip detector on a CFM56 engine. It describes how to check if the detector is contaminated by looking for an extended red indicator and how to reset it. It provides steps to remove and check the detector probe for contamination and clean or replace parts as needed.

Uploaded by

Pédro GONZALEZ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Single Aisle TECHNICAL TRAINING MANUAL

POWER PLANT LEVEL 2 (2)


MASTER CHIP DETECTOR CHECK
There is a red pop-out indicator visible from the oil-servicing door. If
extended, this indicates that the Electrical Master Chip Detector (EMCD)
is contaminated and the probe should be checked. To reset the red pop-out
indicator, remove the transparent cap and push in the clogging indicator
with the thumb.
The EMCD probe is located on the lubrication unit and is made up of
two magnets separated by a gap. The probe will collect any magnetic
particles in the oil system. If the particle contamination closes the gap
between the magnets an electrical signal is generated to extend the pop-out
indicator. To check for contamination, remove the probe as follows:
- Open the left fan cowl,
- At the same time, push and turn the EMCD plug ¼ turn
counterclockwise,
- Disengage the EMCD from its housing,
- Check the AMM for examples of NORMAL and ABNORMAL
contamination,
- Clean the EMCD,
- Replace o-ring if necessary and re-install - check that the RED marks
are aligned.
U7Z08431 - U2XT1T0 - UM70BA000000001

T1 (CFM 56) (Lvl 2&3) POWER PLANT LEVEL 2 (2) Oct 24, 2008
70 - POWER PLANT CFM 56 Page 10
Single Aisle TECHNICAL TRAINING MANUAL
U7Z08431 - U2XT1T0 - UM70BA000000001

MASTER CHIP DETECTOR CHECK

T1 (CFM 56) (Lvl 2&3) POWER PLANT LEVEL 2 (2) Oct 24, 2008
70 - POWER PLANT CFM 56 Page 11

You might also like