Single Aisle TECHNICAL TRAINING MANUAL

START FAILURES (US) (3)


IGNITION FAULT IN MANUAL MODE
If an ignition fault occurs, an aural warning sounds, the MASTER
CAUTion and the engine FAULT lights come on and an ECAM message
appears.
In manual start, the FADEC does not abort the start, you must perform
the following actions necessary to shut down the engine:
- first release the MANual START P/B,
- next set the MASTER control switch to off,
- and finally set the mode selector to the MODE NORMal position.
U7Z08431 - U2XT1T0 - UM74D2CFM000002

T1 (CFM 56) (Lvl 2&3) START FAILURES (US) (3) Oct 24, 2008
70 - POWER PLANT CFM 56 Page 190
Single Aisle TECHNICAL TRAINING MANUAL
U7Z08431 - U2XT1T0 - UM74D2CFM000002

IGNITION FAULT IN MANUAL MODE

T1 (CFM 56) (Lvl 2&3) START FAILURES (US) (3) Oct 24, 2008