You are on page 1of 2

Single Aisle TECHNICAL TRAINING MANUAL

START FAILURES (ME) (3)


IGNITION FAULT IN AUTOMATIC MODE (continued)
SECOND ATTEMPT
At the 25th second of the dry crank period, both ignitors are
re-energized.
Five seconds later, the fuel is supplied, (A B indications are displayed
on the ECAM page).
If engine light-up is not obtained within 15 seconds, the FADEC
automatically cuts ignition and fuel, dry cranks for 30 seconds, aborts
the autostart, turns the engine fault light on and displays an ECAM
message to select the ENGine MASTER to OFF.
U7Z08431 - U2XT1T0 - UM74D2CFM000001

T1 (CFM 56) (Lvl 2&3) START FAILURES (ME) (3) Oct 24, 2008
70 - POWER PLANT CFM 56 Page 162
Single Aisle TECHNICAL TRAINING MANUAL
U7Z08431 - U2XT1T0 - UM74D2CFM000001

IGNITION FAULT IN AUTOMATIC MODE - SECOND ATTEMPT

T1 (CFM 56) (Lvl 2&3) START FAILURES (ME) (3) Oct 24, 2008
70 - POWER PLANT CFM 56 Page 163