You are on page 1of 2

Single Aisle TECHNICAL TRAINING MANUAL

POWER PLANT LEVEL 2 (2)


MEL/DEACTIVATION (continued)
T/R DEACTIVATION AND LOCKOUT
Per the MEL, one or both Thrust Reversers may be deactivated in the
STOWED position for dispatch. The deactivation procedure has two
parts. First, the Hydraulic Control Unit (HCU) is deactivated. Moving
the deactivation lever to the inhibit position prevents the pressurizing
valve from supplying hydraulic pressure to the reverser actuators. In
the second part of the deactivation procedure each pivoting door is
secured (bolted) to the reverser structure preventing any movement.
U7Z08431 - U2XT1T0 - UM70BA000000001

T1 (CFM 56) (Lvl 2&3) POWER PLANT LEVEL 2 (2) Oct 24, 2008
70 - POWER PLANT CFM 56 Page 14
Single Aisle TECHNICAL TRAINING MANUAL
U7Z08431 - U2XT1T0 - UM70BA000000001

MEL/DEACTIVATION - T/R DEACTIVATION AND LOCKOUT

T1 (CFM 56) (Lvl 2&3) POWER PLANT LEVEL 2 (2) Oct 24, 2008
70 - POWER PLANT CFM 56 Page 15