You are on page 1of 2

Ultra• Max Phasing Tool (900MHz) Quick Reference Card

Figure 1. Receiver module Figure 2. Transmitter module

Transmit enable
Battery indicator
(in back) (on = enabled)

Signal Power
strength Transmit on LED
indicator enable/
disable
Power
on/off ABC signal/
Channel Mode select:
Normal/Test/ 0 crossing
selector
External
Channel
Channel Selects one of eight selector
Coarse Fine
selector receiver channels
adjust adjust
Signal strength Indicates signal strength
indicator of selected channel

The basic steps to synchronize all systems are as


follows:
A. Set up a reference transmitter at the reference
system.
B. Synchronize all other systems within the range
of the reference transmitter.
C. Use the second transmitter to extend the range Power
of the reference transmitter. select
fuse
Repeat steps B and C until all systems in the store,
Power
shopping center, or mall are synchronized. Sync on
cord
0°° /180°°
A. Setting up a reference transmitter at the
reference system.
1. Using the receiver module, find the channel with Channel selector Selects one of eight
minimal interference. transmitter channels
While observing the signal strength indicator, rotate ABC Signal/ Transmit pulse for
through the channels and select the channel with the each phase of ac
lowest signal strength. power or
0 crossing Transmit 50 or 60Hz
2. Set up the transmitter module. square wave
a. Set the first transmitter module to the same Sync on 0°° / Sync on 0°° -crossing
channel as the receiver module. 180°° or 180°° -crossing of
b. Locate a power outlet at or near the reference ac power
system and plug in the first transmitter. Mode select for BNC:
CAUTION: Make sure the power select fuse is Normal/ ABC signal (output)/
set for the correct ac voltage. Test/ 0-crossing (output)/
c. Set the switches of the transmitter to Normal External External trigger
mode and ABC Signal. (input)
Coarse adjust/ Adjusts the phase of
3. Verify receiver operation. Fine adjust the transmit signal
a. Connect the sense coil to channel 1 of an Transmit Turns transmit signal
oscilloscope with the long BNC cable and the enable/disable on or off
output of the receiver module to channel 2 with Power select fuse Select correct
the short BNC cable. voltage
b. Verify that channel 2 shows the proper ABC (115,125,230,250)
phase signal from the transmitter (Figure 3).

8000-2574-26, Rev. A1 (2 pages) ULTRA• MAX PRODUCTS 1


Ultra• Max Phasing Tool (900MHz) Quick Reference Card
4. Align the reference transmitter 4. Verify receiver operation.

a. Beginning at the transmitter antenna of the a. Turn on the second transmitter’s signal.
reference system, place the sense coil against b. Switch the receiver channel to the channel used
or near the transmitter coil. Position the coil for by the second transmitter and verify that the
the strongest possible signal. receiver signal from the second transmitter is
b. Verify that channel 1 shows the proper aligned properly. You can verify that it is aligned
transmitter burst signal (Figure 3). properly by comparing it with systems phased
c. While watching the receiver signal and burst previously using the scope and sense coil.
signal on the oscilloscope, adjust the Phase Continue phasing systems as described in Step B. No
Adjustment pot on the first transmitter module timing adjustment are required because of the second
so that the burst signal starts at the Falling transmitter.
Edge of any one of the three pulses (Figure 4). Remove the first transmitter and use it as necessary to
You are ready to begin phasing other systems to the extend beyond the range of the last transmitter location
reference signal. and so on. Each time you setup a new transmitter, you
must realign the new signal with the current reference
B. Synchronize systems within the range of signal as done in step C.
the reference transmitter.
1. At the next system, place the sense coil at or Figure 3. Transmitter burst aligned to one of
near the transmitter antenna.
ABC phase signals (viewed at 4ms/Div)
2. Verify that you are still receiving a clear ABC
signal from the receiver (Figure 3). Phase C Phase A Phase B

3. Align the system to the reference transmitter.


While watching the receiver signal and the system
burst on the oscilloscope, adjust the phase of the
system so that the burst starts at the Falling Edge of
any one of the three pulses (Figure 4).
4. Attach a sticker to the power pack indicating the Transmitter
date that it was phased. bursts

5. Continue phasing all of the systems within range


of the first transmitter signal.

C. Extend the range of the reference


transmitter.
1. Locate a power outlet within the range of the
first transmitter’s signal.
2. Using the receiver module, find another channel Figure 4. Transmitter burst aligned to falling
with minimal interference. edge of phase signal (viewed at 1ms/Div)
3. Set up the second transmitter module.
a. Set the second transmitter to the same channel
as the receiver.
b. Switch the second transmitter’s signal off.
c. Set the switches of the second transmitter to
Normal mode and ABC Signal.
4. Using the oscilloscope, align the second Falling edge
transmitter.
a. Disconnect the sense coil from the BNC cable.
b. Attach the BNC cable to the second transmitter
and channel 1 of the oscilloscope. Burst
c. Switch the receiver module back to the same aligned to
channel as the first transmitter module. falling edge
d. While watching the first and second transmitters’
signals on the oscilloscope, adjust the Phase
Adjustment pot on the second transmitter
module so that the second transmitter’s signal
starts at the Falling Edge of the first transmitter
pulse.

8000-2574-26, Rev. A1 (2 pages) ULTRA• MAX PRODUCTS 2