You are on page 1of 2

R-200 series

Guaranteed Bio-Security: Less Energy Use


Engineered for Accountability & Control

Lamp Out of Water:


• Reduces sleeve fouling, minimizing CIP
• Shorter lamps reduce risk of breakage
• Quick & easy lamp replacement
• No shut-down required for lamp
replacement
• No possibility of broken glass and
mercury in water

Guaranteed Bio-Security:
2 Sensors per Lamp
• One sensor tracks lamp intensity
Medium Pressure UV Lamp Quartz chamber Air Block • One sensor tracks UVT (water clarity)

Recycles UV Photons, Lower


Energy Costs
Real-Time Control
• Quartz treatment chamber
engineered for longer UV light paths • Automatically adjusts UV dose to
and optimal hydraulics changes in real-time conditions
• Patented Hydro-Optic engineering uses • Displays real-time data status,
fiber-optic principles including the actual UV dose being
• All pathogens are exposed to a uniform delivered
UV dose – proven and validated! • Tracks dose and validation
parameters
• Continuous documentation
for QA and regulators
Medium Pressure UV: Better
Protection, Fewer Lamps
• Atlantium Medium Pressure high-
intensity UV lamps more effective and Customized Interface
cost-efficient
• User-friendly integration with plant
• More UV power per centimeter
controls
• Disables DNA proteins involved in cell
• Option for remote monitoring
repair
• User customizes alarm values
• Effective in cold & warm water too
• Touch-screen technology
Medium Pressure High Intensity UV RZ200-SL RZ200-DL

Number of lamps * 1 2

Max Power Consumption (lamp only) 4.2 kW 8.4 kW

Unit Dimensions (L x W x H) inches 93.7 x 35.9 x 59.5 “ (including stand) 99.5 x 35.9 x 59.5 “ (including stand)

Unit Weight (without stand) 408 lbs 637 lbs

Standard pipe connection options Flange DIN 2576 DN150 PN16 / Flange ANSI B 16.5 6” 150lb
Tri-Clamp / Ferrule DIN 11850 6” (A3 standard)
Operating water temperature 39 - 194°F

Maintenance water temperature 39 - 284°F

Maximum ambient temperature 32 - 122°F (cooling unit can be added for environments above 122°F)

Maximum Flow Rate Application dependent

Maximum working pressure 145 psi (10 bar)

Disinfection chamber material High grade fused silica (quartz)

Housing material Stainless Steel 316L

Controller Integrated, with flat touch screen user interface.


Remote monitoring & control optional
Electricity requirements 480VAC, 60HZ, 3 phase 480VAC, 60HZ, 3 phase
5.7kW with fans, 7.2kW with aircondition 9.9kW with fans, 11.4kW with aircondition.

User to provide a flow signal (flow switch/flow meter)

Regulatory Compliance
• EPA 4-log virus and 5-log microbial inactivation
• FDA pasteurized equivalent water/water disinfection
• European Low Voltage Directive (LVD): 73/23/EEC (electrical safety)
• EC/99/93 (quality of water for human consumption)
• ISO 9001:2008 Quality Management
• US Federal Performance Standards 40 CFR 141.720
• GOST Standards Institute, Russian Federation
• National Institute of Public Health, Poland
o
• Resloucion exenta N 2.327 del 31 de diciembre de 2010, en el marco de la
Ley General de Pesca y Acuicultura
• CE compliant
• Biocompatible materials are used in any body part that is in contact with
water for avoidance of irritation, sensitization and toxicity

For more information, please contact your Atlantium representative.


sales@atlantium.com / info@atlantium.com www.atlantium.com

Atlantium Technologies Ltd.


PBG008500 V12/12

POB 11071, Israel 99100


Tel: +972 2 992 5001. Fax: +972 2 992 5005 ©Atlantium Technologies Ltd.