Operational problems during Killing

WELL DEPTH : 7205 ft SIDPP : 550 psi


DRILL PIPE STROKES : 1390 SICP : 640 psi
ANNULUS STROKES : 3887 PIT GAIN : 7.03 bbl
MUD WEIGHT : 10.50 ppg KRP @ 30 SPM: 250 psi
New Pressure
ICP = KRP + SIDPP = Stk Pressure after problem 1
SIDPP 0
KMW = OMW + = ……………………….. 100
0.052 X TVD
200
300
FCP = KMW X KRP = …………….. 400
OMW 500
K = ICP – FCP =………………..
600
700
K X 100 800
Pressure drop per 100 stks = = ………………… 900
STB strokes 1000
1100
1200
1300
1390

Driller’s Method ( 1st Circulation )-Fill all the blanks


1) D/P Pressure-1000psi Csg Pressure 650 (no. of strokes pumped 350 )
The problem is…………………………….
a) Keeping Csg. Pr. constant stop pump & close choke
b) Identify the problem, bring the SIDP at original value (………….. psi)
c) Keeping Csg. Pr. constant bring pump to kill speed
d) Maintain new Drill Pipe Pressure Constant (New d/p press. after pumped reached to Kill rate)

2) D/P Pr.-1100 psi Csg. Pr.- 940 ( no. of strokes pumped 500 )
The problem is…………………………….
a) Stop pump immediately and close the valve upstream of the choke
Line up alternate choke and open HCR
b) Identify the problem, bring the SIDP at original value (………….. psi)
c) Keeping Csg. Pr. Constant bring pump to kill speed
d) Maintain Drill Pipe pressure constant (…………. psi)

3) D/P Pr.- 500psi, Csg. Pr.-340 psi (no. of strokes pumped 800)
The problem is…………………………….
a) Stop pump immediately and close the valve upstream of the choke
Line up alternate choke and open HCR
b) Identify the problem, bring the SIDP at original value (………….. psi)
c) Keeping Csg. Pr. constant bring pump to kill speed
d) Maintain Drill Pipe pressure constant (…………. psi)
4) D/P Pr.- 550 Csg. Pr.- 350 (No sound of pump in Simulator )
(no. of strokes pumped 1200 )
The problem is…………………………….
a) Close choke and bring pump throttle to zero
b) Identify the problem , Line up alternate pump, bring the SIDP at original value (………….. psi)
c) If KRP of second pump is same maintain original Drill Pipe pressure constant (………….. psi)
d) If KRP of second pump is different say (350 psi) maintain new Drill Pipe pressure constant
(………….. psi)

Operational problems in W&W Method


1) After 300 strokes of killing, D/P Pressure- 900psi Csg Pressure 650

The problem is…………………………….


a) Keeping Csg. Pr. constant stop pump & close choke
b) Identify the problem, calculate Remaining SIDP & set it at calculated value (…………psi)
c) Keeping Csg. Pr. constant bring pump to kill speed
d) Draw new Pressure schedule chart (new pressure after problem 1)

2) After 500 strokes of killing, D/P Pr.- 900 psi Csg. Pr.- 940

The problem is…………………………….


a) Stop pump immediately and close the valve upstream of the choke
b) Line up alternate choke and open HCR
c) Identify the problem, calculate Remaining SIDP & set it at calculated value (………….psi)
d) Keeping Csg. Pr. constant bring pump to kill speed
e) Follow original Pressure schedule

3) After 800 strokes of killing, D/P Pr.- 300psi Csg. Pr.-340 psi

The problem is…………………………….


a) Stop pump immediately and close the valve upstream of the choke
b) Line up alternate choke and open HCR
c) Identify the problem, calculate Remaining SIDP & set it at calculated value (…………psi)
d) Keeping Csg. Pr. constant bring pump to kill speed
e) Follow original Pressure schedule

4) After 1000 strokes of killing, D/P Pr.- 230 Csg. Pr.- 430
(No sound of pump in Simulator / spm=0)

The problem is…………………………….


a) Close choke and bring pump throttle to zero
b) Line up alternate pump
b) Identify the problem, calculate Remaining SIDP & set it at calculated value (……… psi)
d) If KRP of second pump is different draw new pressure schedule otherwise follow original pressure
schedule

Remaining SIDPP = (1 - Number of strokes pumped ) x Orig. SIDPP


Surface to bit strokes