Acceptance / Rejection Criteria

Liquid Penetrant Testing Method


According to ASME Sec.VIII., Div.1, App.8 (2004)

Discontinuity

Linear
Round
(Crack,LOP,LOF)

Unacceptable regardless Four or more round indications in a line


of length Round indications > 5mm separated by 1.5 mm or less
(edge to edge)

* Relevant Indications: Indications with major dimensions greater than 1.5mm.


* Linear Indication: Is one having a length greater than three times the width.
*Round Indication: Is one of circular or elliptical shape with the length equal to or less than three times the width.

H.Z.Tavakoli